Loading...
HomeMy WebLinkAbout15 Wedgewood LaneBuildingdng SPFCTI APPLICATION FOR BUILDING PERMIT Plumbing HVAC Date: 0 7 2 5 1 Sprinkler 15 WEDGEWOOD LANE Electric Estimated Cost $ if 19 550 Zoning Permit Fee $ 1 1 24.0 0! Affidavit NO. 17936 Occupancy Fee $ 2-on Eng. Dept. 1/ERB4L Roo avvi /3 COMPLETE RED BOXED AREAS. 1 123 . 00 Health Dept. Fire Dept. TYPE OR PRINT ONLY Total Fee $ Approved for CO: - SIGN ON REVERSE SIDE. Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location 15 WEDGEWOOD LANE SO.WINDSOR Lot No. 16 Side of Street R Zone AA-30 Applicant MILLER REALTY Tel. It 644-81 37 Address 658 ELLINGTON RD SO.WINDSOR CT Zip 06074 Lic.# 500356 STREET CITY STATE Owner J .M.J . CONST . CO Address SAME Architect DAVE GOSSELIN Address SAME Size New Area: Ft. Front Overall 1181 fit. Deep Overall 114 2 . 4 It Total Area "21 1 1 " #Garages 2 No. of Families 2 No. of Stories 2 Construction 2 X 4 LavatoriesBathrooms Rooms 1st 7 2nd 0 3rd 0 Size of Lot 4 0 , 61 3 S. F Dist. from Street Line 115 5 11 Dist. from Side Street Line 116011 Purpose of this Permit CONSTRUCTION OF A SINGLE FAMILY DWELLING City Water ® Well El Septic 13 Sewer 10 Approved by Date BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor. and to notify the Building Insp ctor of any alt ration in the plans or sp cifications of th Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allow d. I(, Signed I hereby apply for a Certificate of Occupancy for the work described in this application for permit. y, Signed 3.---'A-4- 't'o j_' DO NOT WRITE BELOW THIS L14E— INSPECTION RECORD Footing- 2 'Framing " /2--A Foundation 7 Fireplace/Chimney Insulation 'ir_ u Ci Plumbing Permit# 7j Inspections: 9. 'l` U HVAC Permit# Inspections: Electrical Permit# P 0 43 Inspections: Sprinkler Permit# Inspections: BUILDING INSPECTION DEPARTMENT SOUTH WINDSOR, CONNECTICUT FEE PAID: $3.00 CERTIFICATE OF OCCUPANCY ZONE: DATED October 30 198 9 This is to certify that 15 Wedgewooc. Vane Lrected under permit No. 17936 conforms substantially to the requirements of the building ordinances and the zoning regulations of the Town of South Windsor and is hereby approved for occupancy as indicated below. Approved for Occupancy— :aingle family dwelling -- Lot #lb Building Official Notice:If this certificate is lost or destroyed, a duplicate should be obtained immediately from the Building Department. Any change or extension of the use herein approved requires a new certificate of occupancy. CERTIFICATE OF OCCUPANCY CHEC -zSTDlew IJ' 1e:' *y 6, Applicant Miller Realty Certificate of Occupancy 7?93 Address Lit 16 Bldg. Permit No. 7cj Lot No. s s >Date Submitted 10- Project Cambridge Est tes Reviewed By Date As required in the Zoning Regulations, no certificate-of,-occupancy shall be issued until grading-.plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan. 2. Finish grading per approved building permit plan. 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location a. sanitary sewer b. foundation drain c. electrical & telephone d. water e. other 5 . Appropriateroriate certification 6. Bonding Sewer Permit No. Pavement Excay. No. COMMENTS: s aj Applicant r4ay C3 Building Permit No . Address ( Ll(.r J S- w#,vaSD2 Date Submitted Lot No. 116 WcArEcardticf Fie Reviewed by G Project 6Z dr S1`41' Date Z7 In accordance with the Subdivision Re*ulations, prior to the building of any structure on a lot, a Topographic 'plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A r/ 1 . Name, address & phone number of o wner/ applicant. 2. Name , address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, fl oodway, etc. 4 . Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties , etc. b. Easements of record. c. Lot description, bearings , distances , building lines , area, etc. 1Z d. Contours, existing & proposed, 1 or 2 ft interval where appropriate. e. Building location with dimensions . Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems , sanitary & foundation drain at the house and the street. g. Tentative utility location gas , electric water, etc. h.v Title block with name and address of preparer, date appropriate certification live seal and signature. S . Sedimentation and erosion control . 4 6 . Special Planning & Zoning, Inland/Wetlands considerations . (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS JUL 2 T J 19g9 CON=NTS : y,. PERMIT D DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT 1 U 7 t Application is hereby: TOWN OF SOUTH WINDSOR APPROVED BUILDING INSPECTION DEPT. 644 -2511 Ext. 230 Date Building Inspect10"Applications must be printed or typed. 1. LOCATION OF JOB 0 V.-Cm -4 ue w FEE SCHEDULE No. Sereet Floor Apt. No. S 0 - $19000 - 10.00 Over $1,000 - 10.00 2. OWNERV Cc ,s rper1,000 or 3. ADDRESS Mfractionthereof 4. - APPLICANT 5. ADDRESS t I ACTUAL COST $ FEE $ 6. ESTIMATED COST $ ESTIMATED COST $ FEE $ 7. IS THIS A CONTRACT COST? YES Q NO FILE COIF. BY BALANCE $ 8. FEE ENCLOSED 9. r300"F BUILDINGLl)II C RF.SIDENTTAI, Q COi^iERCIAL 1.0. TYPE JOB: RIGINAT, ALTERATION 1!VSTALLATToN C3 ADDITION REPAIR APPLICATION FOR ELECTRICAL PIEPA T(Continued troTu tceverse Side) 11. LOCATION Of Jos NO. STREET3 FLOOR APT. NO. 12. TYPE OF INSTALLATION 13. SIZE OF MAIN FEEDER 14. NO. OF LIGHT LOOPS 15. NO. OF HEAT LOOPS_ 16. NO. OF POWER LOOPS 17. NO. OF LIGHT OUTLETS DO 18. NO. OF HEAT CIRCUITS 19. NO. OF YOWIER Viif1.L•'':'S__ M 20. N0. OF CONVENIENCE OUTLET061. NO. OF HEAT CIRCUITS 22. NO. OF POWER CIRCUITS_ 23, NO. OF LIGHT CIRCUITS 49 24. SIZE OF HEAT CIRCUITS 25. NO. OF 30:ORS 26. NO. OF PANELS 27. TOTAL WATTAGE 28, NO. OP POWER PANELS _ 29. NO. OF SWITCHES L 30. A/C LOAD 31. SIZE OF PCFdER FEEDERS 32: NO. OF FIXTURES 33. TOTAL HORSEPOWER 34. NAMES OF SUBCONTRACTORS AND THEIR TRADES i 35. REMARKS AND FURTHER DETAILS: JoLl LICENSE)NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: t Lot NO. Building Permit Temporary Seryice Permanent Service Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. Owner1p.I: Electrician Street J 19 Buil ing Inspec PERMIT NO. 760 DEPARTMENT DECISION A P P L I C A T I O N F O R APP CATION IS HEREBY: PLUMBING PERMIT APPROVED DISAPP ED TOWM OF SOUTH WINDSOR BUILDING INSPECTION DEPT. 644-2511 Ext. 230 DA E P N INSPECTOR Application must be printed or typed. 1. LOCATION OF JOB: 4 19' e car" Ct:c 2. OWNER: M. 3. ADDRESS: FEE SCHEDULE 0 - $13,000 - $10.00 4. APPLICANT: Over $1,000 - $10.00 5. ADDRESS: r,2- Al f per $1,000 or Fraction Thereof 6. EST. COST: 7. IS THIS A CONTRACT COST? YES NO 8. FEE ENCLOSED: $ 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: O ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB:C J r' A" 1 t i Z4)iJe Ze GENERAL PLUMBING 12. KIND OF INSTALLATION:l,gJi'lCCw' 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 1 16. NO. OF BATHTUBS oZ 16A. NO. OF SHOWERS ___1 17. NO. OF LAVATORIES 18. NO. OF SINKS_19. DISPOSAL_ 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS_ SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS - 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES "~ KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW?of , 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? G!/( i T-/'`" v 29. SIZE OF DUCTS j'" 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN / `' 31A. SIZES OF WATER PIPING & RISERS r 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE ec.f,,"r 34. MANUFACTURERS TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE f,"t LBS. 40. MANUFACTURER I 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE G 38. TYPE It 42. MANUFACTURER LICENSE NO. DATE N U 0' APPLICANT PHONE NO.Jp, b 7 / FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: / '0 ,7 NO. ? R TOWN OF SOUTH WINDSOR EST.COST:.70Da. v- BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-25_11 - Ext. 230 0 - $19000 - $10.00 W&E 5C L_ W Z> f`p '& $1000 or fraction LOCATION OF BUILDING I19T co 1'r7 3/l/ thereof - $10.00 vAl rv,-,-j 12:v OWNER ADDRESS TOWN PHONE NO. HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL - A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR %-- UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT_C ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE^/Q °F INSIDE 7v°F DIFFERENCE $® OF TOTAL HEAT LOSS (BTUH)Z e0--0 HEAT LOSS SHEET MU S ACCOMPAt Y APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.) : Vl-O/C TI VZD?>A&oA1 ULNA(w GROSS HEATING CAPACITY (INPUT-BTUH) 480-D NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE 9_°F INSIDE_Z F DIFFERENCE Z OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.) : V0111jr D AJ TONNAGE --:5 fez COOLING CAPACITY (BTUH) L6 O IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: ('!'L 1 STATE LICENSE - NAME & TYPE #DATE SIGNATURE OF APPLICANT s PROVED DATE 8D 4A 11/88 I = B = R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM Q O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.11 BTUH pu F t If 3 LENGTH EXPOSED WALLS,FT. Q Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN.FT.OF Table 9, Line 3 x H)TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used for Line 5) 7 CEILING CONSTRUCTION C Table 9. L x W) 8 FLOOR CONSTRUCTIONt — D Table 9, L x W or Lin Ft) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H) 10 c 1 Wall(With Openings) 0 e; H c s 2 Walls(With Openings) X 3 Walls(With Openings) or Ent Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL A COL.B -_COL.H -- COL. I—— COL J --_ - COL. K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION1ROOMATSELECTED O H L W H I L W H L W H L W H L W DESIGN TEMP.°42ROOMDIMENSIONS, FT DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT Q 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, Line 3 x H)TOTAL 20% 6 TYPE OF GLASS --- Bottom of table used for Line 5) tFOR CONCRETE FLOOR ON7CEILINGCONSTRUCTION Table 9, L x WI GROUND OR FILL AT GRADE LEVEL,USE LINEAR g FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9,L x W or Lin Ft 1 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 c 1 Wall(With Openings) C 0 03 e 2 Walls(With Openings) 2 XeJ 3 Wells(With Openings) or Ent Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form is available from The Hydr nics institute,36 Russo Piece,Berkeley Heights,N J 07922 FORM 1503 ENVIRO-TECH, INC. VERNON, CONNECTICUT. 06066 871-7802 Page 1 JOB NAME: JMJ CONSTRUCTION 658 ELLINGTON ROAD DESIGN CONDITIONS TOTAL BLDG. HEAT LOSS/GAIN PHONE SOUTH WINDSOR CONNECTICUT BLDG :LOT #16 CAMBRIGE ESTATES Heating: 80 deg f.t/d BLDG Heat Loss BTU 55,454 Estimator: NOTES:Cooling: 20 deg f.t/d BLDG A/C Gain BTU 31,447 Roos 1 Room 2 Room 3 Room 4 Room 5 Room 6 Room 7 Room 8 Room 9 Room 10 Roos 11 Room 12 AREA NAME! BEDROOM BEDROOM BEDROOM BEDROOM BATH FOYER LIVING DINING KITCHEN BATH WASH Outside Wall Length: 33.0 12.0 26.0 9.5 0.0 8.0 43.0 17.0 18.0 8.0 35.0 0.0 Outside Wall Height! 8.0 8.0 8.0 8.0 9.0 8.0 8.0 8.0 B.0 8.0 8.0 8.0 Sq/Ft S or W Glass 1 0.0 0.0 18.0 12.0 0.0 10.0 48.0 0.0 0.0 0.0 6.0 0.0 Sq/Ft N or E Glass 12.0 6.0 0.0 0.0 0.0 0.0 0.0 12.0 24.0 6.0 0.0 0.0 No of Doors 0.0 0.0 0.0 0.0 0.0 1.0 0.0 1.0 0.0 0.0 0.0 0.0 Floor Width 13.0 12.0 13.5 9.5 10.0 6.5 13.5 13.5 18.5 8.0 7.0 0.0 Floor Length 14.0 10.5 10.0 10.0 5.0 10.0 30.0 12.0 10.0 3.5 7.5 0.0 Roof Width 13.0 12.0 13.5 9.5 10.0 6.5 13.5 13.5 18.5 9.0 7.0 0.0 Roof Length 14.0 10.5 10.0 10.0 5.0 10.0 30.0 12.0 10.0 3.5 7.5 0.0 Area Cubic Feet 11456 11008 11080 760 400 520 31240 11296 1,480 224 420 0 Gross Wall sq/ft 264 96 208 76 0 64 344 136 144 64 280 0 Net Wall sq/ft 252 90 190 64 0 33 296 103 120 58 274 0 Wall Heating BTU 11411 504 11064 358 0 185 11658 577 672 325 11534 0 Wall Cooling BTU 504 180 380 128 0 66 592 206 240 116 548 0 S/W Glass sq/ft 0 0 18 12 0 10 48 0 0 0 6 0 S/W Glass Heating BTU 0 0 893 595 0 496 21381 0 0 0 298 0 S/W Glass Cooling BTU 0 0 223 149 0 124 595 0 0 0 74 0 S/W Glass Solar BTU 0 0 11440 960 0 800 3,840 0 0 0 480 0 N/E Glass sq/ft 12 6 0 0 0 0 0 12 24 6 0 0 N/E Glass Heating BTU 595 298 0 0 0 0 0 595 11190 298 0 0 N/E Glass Cooling BTU 149 74 0 0 0 0 0 149 298 74 0 0 N/E Glass Solar BTU 480 240 0 0 0 0 0 480 960 240 0 0 Doors sq/ft 0 0 0 0 0 21 0 21 0 0 0 0 Door Heating BTU 0 0 0 0 0 538 0 538 0 0 0 0 Door Cooling BTU 0 0 0 0 0 168 0 168 0 0 0 0 Floor sq/ft 182 126 135 95 50 65 405 162 185 28 53 0 Floor Heating BTU 21912 21016 21160 11520 800 1,040 61480 21592 21960 448 840 0 Floor Cooling BTU 0 0 0 0 0 0 1 0 0 0 0 0 Roof sq/ft 182 126 135 95 50 65 405 162 185 28 53 0 Roof Heating BTU 437 302 324 228 120 156 972 389 444 67 126 0 Roof Cooling BTU 182 126 135 95 50 65 405 162 105 28 53 0 Lights Cooling BTU 155 108 115 81 43 55 346 138 158 24 45 0 Appliance Cooling BTU 191 132 142 100 53 68 425 170 194 29 55 0 People Cooling BTU 110 76 82 58 30 39 245 98 112 17 32 0 Latent Cooling BTU 588 407 436 307 162 210 11309 523 598 90 170 0 Ventilation Heat BTU 964 562 799 486 166 435 2,068 844 948 205 504 0 Ventilation Cool BTU 425 242 532 338 61 287 11396 377 494 111 262 0 Duct Heat Loss BTU 379 221 314 191 65 171 814 332 373 81 198 0 Duct Cool Loss BTU 167 95 209 133 24 113 549 148 194 44 103 0 Area Heating BTU 61698 3,902 51555 3,379 11151 31020 14,372 5,B67 61587 1,423 31500 0 Area Cooling BTU 2,952 11681 31694 2,348 422 11997 91703 21620 3,433 774 1,822 0 Area Air Heating CFM 88 51 73 44 15 40 189 77 87 19 46 0 Area Air Cooling CFM 98 56 123 78 14 67 323 87 114 26 61 0 TTL Building. Square feet-> 11486 Heating Air Changes/Hour -> 3.68 TTL Building. Cubic feet-> 11j884 Cooling Air Changes/Hour -> 5.29 TTL Building Heating CFM -> 730 Heating CFM per SO/FT ->0.49 TTL Building Cooling CFM -> 1,04B Cooling CFM per SO/FT ->0.71 013/01 /89 HEATING/COOLING BTU ESTIMATE :