Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
15 Jean Lane (3)
1 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 1f -7 1 APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 4 03 Sw, 644-2511 ext. 230 021,3S2atBuildingInspector Application must be printed or typed Location of Job:FFEESCHEDULE FTenant0-$1,000=$13.00 Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof esignation Apt.No. APPLICANT APPLICANT ADDRESS r- a • os" C 4:7 © 7 APPLICANT PH7# B S c.C. C S ba, &/4--0*4MR ADDRESS 6'bi P 3 3 2oHONE C ESTIMATED COST$ l, 3 D - Cr CU thaw IS THIS A CONTRACT COST? „*es 0 No 3 C FEE ENCLOSED$ O Q, 1 TYPE OF JOB: OR-CO New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: HEATING 4RESIDENTIAL 11xC COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING q4-DESIGN TEMP.OUTSIDE /OF INSIDE 7Z- OF DIFFERENCE 2 OF TOTAL HEAT GAIN(BTUH) 3D (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL N V+-P l E-- p-r- © q? TONNAGE ` COOLING CAPACITY(BTUH) q v VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 6 3 (Q 5 /c 7 CONTRACTORS LICENSE NO. TYPE L STA E SIGNATURE OF APPLICANT DATE ` 1 O JEAN LANE HVAC LOAD ANALYSIS for Lt11130%vare RHVA RESIDENnALArID UGH'1' COMMERCIAL HVAC LOADS Prepared By: Steve Smith Advanced Heating&AC Inc. 701 Nutmeg Rd.North So.Windsor,Ct.06074 282-0205 04-11-2003 r,r. ..-{,y+'„i.L;ry;1;:".c ..astsJ.. 1`, t r,ri 4'`.y':2:.•i`+:,'`(r'i:4-F v RHVACrv. i, 11iM0f.y1"yy tOr tlti tno Project: Jean Lane Company: Advanced Heating &AC Inc. Client: Puida Builders Representative: Steve Smith r Address: Address: 701 Nutmeg Rd. North City: So. Windsor, Ct. 06074 City: So. Windsor, Ct. 06074 Phone: 644-3332 Phone:282-0205 Fax. Fax: 528-2949 Comment: I I t,.:r,:{ '''(rJ*d/!li,' i. ; r,p,,,r0'7: X,.'*, t r., of . a-R:.T:•.L. Fr De3{9•: T y.T w,[C,r. tp` ..(F a ro xom,:.`. :+^i•;•,•:`'4-:.r• ,r.,'.: y n„`_•.• r ',9•, z I Project Name- Jean Lane Comment: Edit the file AUTOLOAD.RHV so that it contains your company name, weather data, and any other information you would like to have in each new project that you start. Reference City: Hartford, Connecticut Daily Temperature Range: Medium Latitude: 41 Degrees Elevation: 19 Feet Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 7 N/A N/A 72 N/A Summer: 92 73 50% 72 33 I ;) r•'x r ¢:rtl+•iti+W'dr{'AY's r,A-A's...... y., - MINAMkr Y r Total Building Supply CFM: 1657 CFM per square foot:0.62 Square feet of room area: 2,674 Square feet per ton: 678.319 IFf1' if u v. Total heating required with outside air: 80,836 Btuh 80.836 MBH Total sensible gain: 36,425 Btuh 92 % Total latent gain:3,327 Btuh 8 % Total cooling required with outside air: 39,752 Btuh 3.313 Tons (based on sensible+ latent) 3.942 Tons (based on 77% sensible capacity) 1a4. •' .",.,*Y;rr 3+ysiu;F!•Nil pp Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday,April 10,2003 Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 514 24,225 0 18,634 18,634 11 E Door Metal Urethane Core 21 259 0 94 94 12C Wall R-11 + 1/2"Gypsum(R-0.5)2,051 12,000 0 4,356 4,356 16D C iling R-19 Insulation 1,404 4,836 0 3,274 3,274 16G Ceiling R-30 Insulation 440 944 0 639 639 19B Floor Over Sasement/Encl Crawl Hardwood+R-11 338 879 0 0 0 201 Floor Over Open Crawl Carpet+ R-19 156 487 0 112 112 Subtotals for structure: 4,924 43,630 0 27,109 27,109 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances:0 0 0 0 0 Lighting: 0 0 0 Ductwork: 0 13,473 0 6,070 6,070 Infiltration: Winter CFM: 332.2, Summer CFM: 147.6 535 23,733 3,327 3,246 6,573 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 36,425 T mperature Swing Multiplier:X1 00 Building Load Totals: 80,836 3,327 36,425 39,752 Total Building Supply CFM: 1657 CFM per square foot:0.62 Square feet of room area: 2,674 Square feet per ton: 678.319 Total heating required with outside air: 80,836 Btuh 80.836 MBH Totals nsibl gain: 36,425 Btuh 92 % Total latent gain: 3,327 Btuh 8 % Total cooling required with outside air: 39,752 Btuh 3.313 Tons(based on sensible+ latent) 3.942 Tons(based on 77%sensible capacity) Calcuiations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday,April 10,2003 fC'',t{c.{`/ ''S'i r5`•t r3{;•tvM,.` T n i'..1 f•Ry.h"•',..,y•,•v,'•-•- „a+r-4' I s, .,.vo'!+'.rr•y r(4r r taSi dryn^rl.ff°$' Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM Zone 1-- 1 Existing Upper 1248 23,866 310 5-6 459 9,906 734 451 1.17 526 451 Level 2 Existing Lower 390 4,153 54 1-4 685 1,315 149 60 1.15 69 60 Level 3 Florida Room 156 16,229 211 5-6 480 10,358 746 471 1.25 589 471 4 New Add Upper 440 20,774 270 4-6 483 8,334 952 379 1.00 379 379 5 New Add Lower 440 15,814 206 3-6 503 6,512 746 296 1.00 296 296 System 1 Totals 2674 80,836 1,051 36,425 3,327 1,657 1,859 1,657 Main Trunk Size: 18x16 in. u' h v t /f; A`• sr• SIB n1101 f i y'ic!fkW#•'i Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required:3.313 92%/8% 36,425 3,327 39,752 Recommended: 3.942 77%/23% 36,425 10,880 47,305 i I Thursday,April 10,2003