Loading...
HomeMy WebLinkAboutBuilding 15 Arthur Drive (5)PERMIT # Application For 6 619 6229 Cd Cd W DEPARTMENT DECISION Heating Permit 3 APPLICATION Is HEREBY:DEPARTMENT OF LICENSES AND INSPECTIONS o a APPROVED El DISAPPROVED TOWN OF SOUTH WINDSOR GJ A E CN EF APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O to E ^v 1. LOCATION OF JOB O a, O Cd r. NO. STREET 4j O t Ir, r oy r W LOT NO. FLOOR APT. NO. O {~ON o T R Re lry2. OWNER cc S. ADDRESS 6 8 E111ayhn if P*J1~cd o a o 0 3 ai a 504 1 wi Il r 'fD O 4.hHONE p. V] ' S. APPLICANT 6--e-mt/j k4I-rt-M 4 wf o ADDRESS Y" "47 AW If4dB. y sa4? 4i wjlrr ct- 06071/7.PHONE f A B. LICENSE NO. Soar) a: .g E w s. EXPIRATION DATE OF LICENSE 01,Pt O 10. ESTIMATED COST S o m 11. IS THIS A CONTRACT COSTY 4RIYES MO b0 m G 12. FEE ENCLOSED S Pprmit 14 4 S S d dU y ai 1 S. TYPE 0 BUILDING: h b0 MESIDENTIAL COMMERCIAL O Ce d 14. TYPE OF JOB: INDUSTRIAL INSTALLATION ADDITIONON REPAIR APPLICATION FOR HEATING PERMIT (Continued tr m eever" Side) 11. LOCATION OF JOB AICJI 1 r'A-r7Atr Arty-( Sf, ZIj NO. STREET S FLOOR AFT. NO. T12. YPE F INSTALLATION:: ElOIL B OURNERkLECTRIC VENTILATION SPRINKLER LJ GAS BURNER P STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED - YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORK f!! A f L 15. TO BE DONE: r/d B/ 1 !T I 4LT I f q/.r/1f 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ROOM SIZE AND DOORS AREA - SQUARE FEET VOLUME B.T.U. s.T.U. g i I- DISTRIBUTION INSTALLED TOTAL TOTAL YI LL ROOM NO.GROSS GLASS NET WALL CEIL-ING FLOOR CU.FT. AT A•F CORRECTED t:IRAD REGISTER L WF DIFF. AND TEMP. TO F TYPE AND SIZE OR LEADER SIZE j WALL 'to INFILT.) f F f IS a 90. IT. FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING, OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND 18. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN.44f Zo 144rr DATE SIGNATURVDF APPLICANT ARTFORD C0NNErTICU.T LAT = 42 ALT = 15 ONST- 70W/40R/ 70B ID= 75 70 ALL COLOR: MEDIUM ROOF COLOR : MEDIUM SER# 60215 31 . 6 D.B.TEMP TOTAL TONS RSH TONS CFM JUN AT 9 A.M. 75. 6 56 1 . 27 692 2. JUL AT 9 A.M. 78 . 6 1 . 71 1 . 36 742 3. SEP AT 10 A.M. 75.4 1 . 76 1 .49 811 OCT AT 2 P.M. 74 .0 90 1 .67 908 SEP AT 3 P.M. 85 .4 40 2 . 02 1 , 102 JUL AT 4 P.M. 90 .0 56 1 , 142 7. JUN AT 4 P.M. 87 .0 42 2 .01 1 , 096 E HEATING--> - 24 , 295 W/INF L- 30, 663 CFM 558 INPUTS RIENTATION OF BUILDING N S E W RF ANSMISSION FACTORS 0. ( 8 0. 08 0.08 0. 00 0 .08 L F- .55 IS LI-FLO Y SHADE FACT=0. 63 NO . FLOORS 2 GTH - 24 WIDTH - 36 HEIGHT - 16 VA .= 7 OUTPUTEE U'MBER OF PEOPLE - 4 SENSIBLE PEOPLE LOAD = 980 TAL LIGHTS 2 , 1.60 LIGHTING LOAD 9 , 215 THER ELECTRICAL - 432 0 HER ELECTRICAL 1 , 474 1EA OF N . GLASS - 65 NORTH GLASS SOLAR 648 AREA OF S . GLASS - 65 SOUTH GLASS SOLAR 1 , 305 AREA OF E . GLASS - 0 EAST GLASS SOLAR 0 AREA OF W. GLASS - 60 WEST GLASS SOLAR 5 , 198 TOTAL GLASS AREA - 190 TOTAL GLASS SOLAR 7 , 152 TOTAL GLASS AREA - 190 TOTAL GLASS TRANS . =1 , 567 rl AREA OF N. WALL - 319 N WALL LOAD 217 AREA OF S . WALL - 319 S WALL LOAD 548 J1REA OF E . WALL - 576 E WALL LOAD 571 tEA OF W. WALL - 516 W WALL LOAD 0 OTAL WALL AREA - 1 , 730 T TAL WALL TRANS . 1 , 336 RIA OF ROOF 864 ROOF LOAD 2 , 205 AFETY FACTOR 5% SAFETY B .T.U .S 1 , 197 4UPPLY FAN H.P. -0. 33 FAN HEAT GAIN - DT =1 ,003 8ITILATION CFM - 86 0 A . SENSIBLE LOAD =1 ,426 UMBER OF PEOPLE - 4 P OPLE LATENT LOAD = 820 ENTILATION CFM - 86 0 A. LATENT LOAD 2 , 379 QTAL CFM-STD AIR- 1 , 1.42 TOTAL LATENT LOAD 3 , 199 M SENSIBLE 25, 127 ROOM LATENT 820 FLATS GRAND TOTAL LOAD -30, 754 TU' S OR LOAD RUN FOR # 6 JUL AT 4 P. S EA (SQ FT) 1 , 728 S FT/TON 674 AL CFM-STD AIR- 1 , 1.42 C M/SQ FT 0. 66 HEATING L AD RNTILATION LOAD - 6, 368 R OF HEATING LOAD 4 , 631 ASS HEAT LOAD - 7 ,001 W LL HEATING LOAD 6 , 508 11FILTRATION LOAD- 6, 368 W RM UP LOAD 748 AB HEATING LOAD= 51407 H AT LOAD WITH V 30, 663 COIL SELECTION PA AM E TEMP ENT/LVG -, 76. 1 / 54 . 2 TOT SENSIBLE LOAD 27 , 555 TEMP ENT/LVG - 62 . 8 / 53.6 TOTAL COIL LOAD 30, 754 IFIED ROOM RH- 55% R SULTING ROOM RH 47% MINAL AIR TEMP- 55.00 / 120 DEGREES ROTATED 0 LY FAN STATIC- 1 .00 NON-CEILING RETURN U' FACTOR-0. 10 CARRIER DEFAULTS