Loading...
HomeMy WebLinkAbout1449 John Fitch BoulevardTOWN OF SOUTH WINDSOR PLANNING AND ZONING COMMISSION PLANNING AND ZONI OMMISSION ACTION THIS APPLICATION SHALL BE ACCEPTED BY 1 APPLICATION # 8*P THE PLANNING AND ZONING COMMISSION AT RECEI;7ED DATE:. l r THE REGULARLY SCHEDULED MEETING ON THE APPROVAL DATE: FOURTH TUESDAY OF THE MONTH. IT SHALL REJECTED DATE: 01 BE SUBMITTED TO THE PLANNING AND RECEIPT # 27 ZONING COMMISSION OFFICE ONE (1) WEEK PRIOR TO THE FOURTH TUESDAY. APPLICANT:Gelco Space ADDRESS : Two Bala Plaza, Bala Cynwyd, PA 19004 TELEPHONE # (215) 668-7735 OWNER OF RECORD ON S.W. LAND RECORDS Third Generation Realty III ADDRESS : 1449 John Fitch Boulevard South Windsor, CT 06074 COMPLETE DESCRIPTION OF LOCATION OF PROPERTY 14V# 42, Lot# 9 on the east side of Route 5 appro dm. tely 200' south of Kimberly Drive. ZONE I NAME, ADDRESS & TELEPHONE # OF PERSON TO WHOM CORRESPONDENCE AND INQUIRIES SHOULD BE DIRECTED: Joe Ulinawski, Two Bala Plaza, P.O. Box 7100 Bala Cynwyd, PA 19004 735 THIS APPLICATION S FO R:OR. (CHECK ONE OF THE FOLLOWING) 1. Zone Change to Zone (public hearing) SEP 405 2. Filing for Subdivision WindsorSouth 3. Filing for Open Space Subdivision (public hearing) Planning & Zur,i g CnmmiSSlOn 4. Filing for Resubdivision (public hearing) 5. Special Exception to Article of the Zoning Regulations (public hearing) X 6. Site Development Plan 7. Removal of Sand, Gravel, Clay or Quarry Stone & Ore (public hearing) 8. Other (explain in detail) THIS APPLICAT 0 MUST BE S GNED BY THE APPLICANT AND THE OWNER OF THE PROPERTY AND SUB TTED ALON I THREE ETS OF PLANS BEFORE WILL BE ACC D THE PLANNING AND ZON G COMMISS ell PLICA OWNS over) PROCEDURES TO BE FOLLOWED WHEN SUBMITTING THE APPLICATION: 1. Applications must be filed in triplicate. The applications shall be typed or neatly printed. 2. Maps and plans, as defined in the applicable regulations, shall be submitted in triplicate with the application forms . 3. An application fee of $25. is required for filing items #1, #5 and V. 4. A subdivision processing fee of $25. per lot ($50. minimum) is required for filing items #2, #3 and #4. 5. A $20. deposit must be submitted with any item requiring a public hearing. This deposit is for a sign to be placed on the property by the applicant advertising the public hearing. The check will be returned to you when the sign is returned to the Town. 6. Application for Zone Change (item #1) shall comply with Section 11.2.3 of the Zoning Regulations. 7. Application for subdivision and resubdivision (items #2 and #4) shall comply with the requirements set forth in the Town of South Windsor Subdivision Regulations. 8. Application for an open space subdivision (item #3) shall comply with Section 5.3 of the Zoning Regulations. 9. Application for a site plan of development (item #5) shall comply with Section 4.11 of the Zoning Regulations. 10. Application for sand and gravel removal shall comply with Section 9.3 of the Zoning Regulations. IN ACCORDANCE WITH STATE STATUTES, THIS APPLICATION WILL BE ACTED UPON BY THE PLANNING AND ZONING COMMISSION, OR A PU.3LIC HEARING DATE WILL BE SET WITHIN 65-DAYS OF THE DATE OF ACCEPTANCE OF THE APPLICATION. CHECKLIST REQUIRED INFORMATION SITE PLANS This checklist must be signed by plan preparer (P . E. /L.S . ) declaring that all required information is provided . Items 1-7 are required for all applications ; items 8-11 required where, appropriate. Check- mark for each item supplies. 1 1 . On each sheet for plans or maps , title block with the following information : I a . Name , address and telephone of applicant . b . Name , address and telephone number of VW'4_ or Professional En ineer n lk8V c . Name of Development . sEP N d . Date when drawings were made . South W ind;or 1/ 2 . Key Map : An overall map drawn to a scale gllnnin &c ilEOmmission equals 200 feet , which can be used as an *overlay o-n Metropolitan District Maps . This map will show the overall design of the Development and surrounding property within 500 feet . a . Data block which gives needed zoning information such as percentage of lot coverage, acreage of tract , number of apartment units, parking requirements , etc . b . Layout of buildings V C . Layout of streets and parking . d . Lines indicating proposed drainage system w i-th direction arrows . v e. Lines indicatingsanitary sewer system withYY directio-n arrows . t f . Names of surrounding property owners. g . Proposed open spaces and recreation areas. h. Driveway cuts on surrounding properties. 3 . Architectural Elevations : Plans of the proposed buildings drawn to a scale of 1/8" = 1 ' - 0" showing the elevations of all sides of the proposed buildings in sufficient detail to show architectural styling. Architect ' s seal on elevations for buildings in excess Page 2 (Site Plans) VA . Plot Plan : A layout map of the proposed site drawn to a scale of 1 inch equals 40 feet on either of the following size sheets: ( 1) 24" X 36" with a 3/4" ruled margin ; (2) 18" X 24" with a 1/2" ruled margin , containing the following data: a n f andDistanceandbearingsoallboundarylines acreage of site. Iron pins required at all property angle points and shown on map, V b . Proposed streets and street lines with center line stations , curve data , and parking spaces . V C . Building lines in accordance with honing regulations . d . Proposed buildings and other structures , including signs , outside lighting, and dumpsters (on concrete pad and screened) e . Easements , noting grantors , grantees , and purpose. f . Names of abutting property owners. g . Monuments will be indicated at corners and angles of all streets and at all points of curvature and tangency . In areas accessible to Metropolitan District Commission. points-, or other coordinated points, the monumented- points within proposed site shall be coordinated . These coordinates shall appear in tabular form on the plot plan . The accessibility of these MDC points shall -be determined by the Town Engineer. h. All open space or other common or public land uses shall be indicated. i . A-2 certification ; P . E. /L. S . Seal. T drawn to a scale of 1 inch toTopographicMap : A map ra 40 feet on sheets not exceeding 24 inches by 36 inches , including ruled margins shall in addition to the requirements of the plot plans show the following: a. All existing and proposed buildings . V b . Curb lines and pavement width, sidewalks. C . Existing and proposed sanitary sewers . 2 d . Existing and proposed water and gas main systems . e . Present wooded area indicated by foliage lines . Any individual trees to be saved should be shown. 4 i Page 3 (Site71ans ) f , Existing and proposed contours shall be shown in not less than two-foot intervals , burin cases of relatively level land , the contours be one-foot intervals and spot elevations . g , Regulated wetlands and 100-year floodplain or note that none are present. h. Proposed storm drainage system, showing all catch basins , endwalls , manholes , lengths and sizes of pipes . (MA)(imum distance between catch basins shall be 300 feet and minimum size of storm gain lines shall be 15 inches . ) Connections of all springs into proposed sto m drainage system as needed . j . Location and indications of existing brook channels , and 100-year flood limits . k. A-2 Certification ; P . E. /L. S , Seal . 6 . Landscaping plan . 7 . Drainage calculations - Zero Runoff Increase per t T attached guidelines . . ,01'/'e..c7 S v/j Di v Sio•^ 8 . Traffic report . 9 . Plans and Profiles : A plan and profile of the proposed paper of scales 1 inch to streets drawn on plan/profile 40 feet horizontally , and 1 inch to 4 feet vertically on sheets not exceeding .-24 inches by 36 inches , including ruled margins and containing the following : a. Layout of streets in sections coordinated by stations with the profile . b . Street plan showing roadways and drainage.' C . Sight line at driveway & street intersections . d . Profile of roadway showing existing and finilshed nt grades . Roadway profile will show all tange grade and all vertical curve information. e.Profile will -show all catch basins and all drainage d top lines between catch basins with all iwilltb nshown i of frame elevations . Drainage lines and described as to material . f , Where any storm drainage line discharges into an existing brook sufficient profile of this brook will be shown to determine conditions . 3 District Commission datum shall be g , Metropolitan i used on all sites accessible to these controls . i The Town Engineer shall , based on standard engineering practices , determine the access 1 Page 4 (Site Plans) h. Profiles shall show all sanitary sewer liners and manholes , including elevations , sizes, lengths , and slopes of pipes . Top of foundation elevations for building shall be shown . i I i Iy/r' 10. Open Space Site Improvement Plans: , For sites which require or include a provision for open spaces,i a plan which contains data for site improvement may bej required . This map shall be drawn to a -scale o'f 1 inch equals 40 feet . 11 . Sanitary Report: Where individual sanitary se age disposal systems are proposed , the final plans shall include a Sanitary Report certified by a Profe sional Engineer . The report shall demonsatra6e the fe sibili'ty of the proposed. individual systems ; the report should deal with the are-a as a whole , discussing the ollowing points : a . General nature and development of surround 'ng area . b . Topography and natural drainage pattern. C . Subsurface conditions - as shown by subsurfa e investigation , including soil absorption characteristics , ground water level condit ons , ledge rock , and general nature of- soil . d . General description of type of development contemplated . e . Detailed description of proposed sanitary ewage disposal facilities , indicating sizes for arious ground conditions , materials to be used , a d the general layout pattern to be used , etc . f . Special precautions that may be necessary o provide proper functioning - of the proposed disposal systems. g . Map of general area with locations of all ests shown on proposed layout . h. Flood heights of any nearby streams, brook or rivers . s i. Test results and engineering evaluation pe- Section 4. 13 . 5 . 3 All information required above is included in this application at the time of submission . D 4 40 51 AN PARER . E. L.S . DATE November , 1987 GELCO SPACE SITE PLAN 1 .Application_ for a -1,372 sq ft off-ice-build-i-ng"t i be constructed on an existing site located on the westerly side of John Fitch Blvd. , just south of Kimberly Drive, I zone. Th-a--smote building coverage is 2%; 50% allowed, total impervious coverage including the gravelled area is 3 .3%; 65% allowed. It appears that all other zoning requirements have been met. 2 . The parking required based on the office use is 11; 12 spaces have been provided. The remainder of the back part of the site will be for the parking of 18 wheeler vehicles. The site currently has some trucks parked on the site and is overgrown with weeds . This plan will help to clean up the situation out there. 3 . There are regulated wetlands on the site. The received IWA/CC approval on November 13 with the following conditions: areas with loose debris to be removed and stabilized recommend a bond of $6,000 to ensure compliance with E & S measures 4 . The site will be serviced by public water and sewer. WPCA approval is not required. The Collector of Revenue should be notified as to incremental increase in developed acreage for purposes of calculation of sewer connection charge. 5 . There is a dumpster proposed on a concrete pad nd screened. No new landscaping is proposed for the sit . We would like to see something added to the south side of the ite to provide some additional screening -either a fence OfO ome trees that will provide some buffer. The north side of the site is buffered by an area of thick vegetation. A slatted Chain link fence is proposed at the beginning of the drive. The., back of the site is not visible from John Fitch Blvd. 6 . The architecture for the building depicts that it will be a modular sided office with a mansard roof. If this application is approved, the planning department requests no further modifications. r STANDARD APPROVAL MODIFICATZONS .FOR SITE PLAN (rev. 2/7/89) PROJECT APPL. NO 7 ENGINEER/ARCHITECT PROJ. NO DWG. NO.-DATE ' -'REV. DATE !0 - 9 SUBMIT MYLARS OF SHEETS . . . 1 . Prior to commencement of any site work, a meeting must be held with Town Staff . 2 . No building permits will be issued until the final mylars have been filed in the Town Clerk's Office. 3 . This application is subject to the conditions of approval of the Inland Wetlands Agency/Conservation Commission, including a bond in the amount of $ /„ l 4 . An as-built plan is required prior to issuance 3f a Certificate of Occupancy per Section 4 . 13 . 10 of the Zoning Regulations . 5 . Footing drains are required if the building has a basement: J6 :) A landscape^ bond in the amount of $ is required dnd must be submitted prior to filing of mylars . V/ 7 . All plans used in the field by the developer must bear the stamp and authorized signature of the Town of South Windsor. Black and white transparent mylars of Sheets # with the above modifications, together with three blueprint copies of the entire set of plans must be submitted to this Commission within 30 days to be st mped and signed. The letters of approval of this Commission, as well as the I land Wetlands Agency/Conservation Commission, must be reproduced on the my ars . After the mylars have been signed by the Commission, they will be returned to you for filing in the office of the Town Clerk within 90 days . After filing these plans, a copy of the receipt must be submitted to the Planning Department. loo o'O.4-1 Or 46- I t is ° PALMBERG & RUSSO LEETT[Q VF 15 Barber Pond Road BLOOMFIELD, CONNECTICUT 06002 DATE 7_25-—4w OD N04?90 6.SS 203) 242-2775 ATTENTION gl''r/i9- RE TO GJAI G..i,lcrt ' N Nc 0} 6elco WindsorSnilfti Q fZo&WE ARE SENDING YOU Attached ElpUnderse arate cover via F`a(1 wing Cvm nissifl o wing ems: Shop drawings X Prints Plans Samples IL Specifications Copy of letter Change order ar -10'& COPIES DATE NO.DESCRIPTION 3 2z,4.vs 3 8/7/8{i X96 6 IAAIA G r Zo•w„!G l c4l 70r THESE ARE TRANSMITTED as checked below: For approval Approved as submitted Resubmit-copies for approval For your use Approved as noted Submit copies for distribution As requested Returned for corrections Return-correctec prints For review and comment FOR BIDS DUE 19 PRINTS RETURNED AFTER LOAN TO US REMARKS A ir-e 0!t xjr CTC--- 00600 Armecl'polaleata' e.-'Oel COPY TO POI/ SIGNED: PROW240.2 a int,Groton,Mm 01471 If enclosures are not as noted, kindly notify us at nce. PLANNING DEPARTMENT IN-HOUSE REFERRAL FORD Jean Zurbrigen TO: Karl Reichle, Mike Gantick, Mel Stead, Fred Shaw, Richard J. Sartor, Gary Tyler, Fire Ma shall Lanning, Jim Snow FROM: Marcia A. Banach, Director of Planning The Planning & Engineering Departments have received plans for the following project:# 1 Zone -1- Acreage L ILI Subdivision Site Plan Residential No. of Lots/units Commercial Industrial Location: Project Description: 13 Future Town-owned property involved? Yes No a)new streets existing frontage also) b)new open space/recreation area active passive c)new detention area Planning Department comments P l a s e l t me know by if you will have comm nts n this app ication so that I can follow up with yourdepartmen wh I do Planning D partm nt report. PLANNING DEPARTMENT IN-HOUSE REFERRAL FORK Jean Zurbrigen TO: Karl Reichle, Mike Gantick, Mel Stead4 Fred Gary Tyler, Fire Ma shall Canning, Jim Snow FROM: Marcia A. Banach, Director of Planning The Planning & Engineering Departments have received plans for the following project:# AL.,L s Ltc— Zone Z Acreage Subdivision Site Plan Residential No. of Lots/units Commercial Industrial d 'Location: Project Description: y i `r c-U,, -' 13V r-- J Future Town-owned property involved? Yes No a)new streets existing frontage also) b)new open space/recreation area active passive c)new detention area Planning Department comments Please let me know by la q ?5 if you will ha e comments on this application so that I can follow up with your d partm nt when I do a Planning Department r port: owN Ce U 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN 06074 R-co AREA CODE 203/644-2511 Octobec 23, 1989 TO: Marcia A. Banach, Director of Planning FROM: Jerry C. Iazzetta, Town Engineer RE: Gelco Space Site Plan We have reviewed the plans dated 7-28-89 for Gelco Space and have the following comments: 1. Roof leader not defined, i.e. size and type of pipe, slope. 2. The drainage calculations utilize a coefficient of .8 for the gravel areas. The Town' policy is to use the same coefficient for ravel and pavement. Please submit revise runoff calculations. 3 . There is an additional 4 .2 cf s of runoff during a ten year storm. This is proposed to sheet flow off property into the surrounding wetland area without any detention. a. The impact upon the wetlands is not addressed. b. A way of filtering out gas and oil from pavement/gravel areas before the runoff reaches the wetlands is requested. (i.e. catchbasins w/hoods, grassed svrale etc. ) C. The drainage study indicates the closeness to the Connecticut'. River - however nothing is shown or stated as to actual distances. 4 . The two 6 .5' RCP pipes need to be addressed as they have shifted and will become a problem. 5. Additional contours and/or spot elev tions are required within the parking areas. There is insufficient information to determine what this area will look like. 6 . Stabilization of embankments is not addressed. A t o to K VyW Chief of Polic Police Services SOUTH WINDSOR POLICE DEPARTMENT CONSTRUCTION REQUIREMENTS Project Title: Gelco Site 89-78 P Date:30 October , 1989 jl 1. Developer is responsible for the purchase and installati n of all street and traffic signs. Any signs on or intersecting -With a State Highway must be cleared through the Department ofTrans- portation. All signs must be in place before a c.o. is issued. 2. Developer is responsible for the purchase of all street lightingthroughConnecticutLightandPower. CUP will install all lighting once they have received payment from the develop Br and the locations of the lights has been reviewed by the Poli e Department. All lighting must be in place before a c.o. Ls issued. Z, 0000, 3. Developer will submit three (3) 8-11 x 11 or 8-;1 by 14 maps of -the proposed project to the Police Department for the purpose of identifying and locating all signs. Completed maps will be distributed to the developer, Town Planner and the Police Department. Any changes in road design will require new imaps. 4. Temporarystreet signs must be in lace as soongPs as possible and maintained throughout the project. 5. Emergency phone numbers for the duration of the construct on must be provided to the Police Department on a company le ter- head. If the developer occupies or owns the building/s a ter construction emergency numbers must be provided to the Police Department. 6. All buildings located on property which abutts a public highway must be numbered. Such number/s (address) shall be visible from the street. All numbering shall comply with Town Ordinan e 6-800 thru 6-802. Barns, garages and outbuilding which are located on the same premises as a numbered structure are excluded. 7. Require that street lights be installed on SNETCO # pole numbers 1686 & 1958 with 100 watt H-P Sodium. 151 Sand Hill Rood • South Windsor, Connecticut 06074 • (203) 644-2551 2- CONSTRUCTION SUGGESTIONS 1 . Keep all shrubbery low around doors and windows so as to allow an unrestricted view. 2. Locate business name, if applicable, on the building. 3 . Backlight business name and address . l 4 . Provide lights over all doors . YS . Provide ample lighting of parking areas . 6 . Advise the new owner / purchaser to Provide the Police Department with emergency numbers - (Business , Commercial and Industrial property only) . SIGNATURE Sergeant Thomas C. Hart #103 Traffic Services Unit Approved by: hief Ga K. ler r. AowM af,< C 1540 SULLIVAN AVENUE SOUTH WINDSOR, CONN. 0 074 R.COt,AREA CODE 203 644-2511 i November 8, 1989 Mr. Joseph Russo Palmberg & Russo 15 Barber Pond Road Bloomfield, CT 06002 Re: Application #89-78, Site Plan of Development, Gelc Space Dear Mr, lsso: Attached is a copy of comments from the Planning and En ineeririg Departments regarding the above-referenced application. Please make the necessary revisions to the plans and submit 6 complete sets (including architectural elevations, landscaping plans, etc. ) to the Planning Department. If you have any questions regarding the comments or the procedure, please contact me. Very truly yours, Marcia A. Banach Director of Planning cc: Jerry Iazzetta, Town Engineer GELCO SPACE SITE Planning Department Comments 1 . dumpster on site should be shown on concrete pact and screened 2. outdoor storage must be screened in accordance vrith Sec. 3 .15. 1 JiN a ce e 1540 SULLIVAN AVENUE SOUTH WINDSOR. CONK 06074 AREA CODE 203 644-2511OgOR•COti November 14, 19 SOC nGlcoSpace y`y,, _.Comoss-o Two Bala Plaza 1o V, Bala Cynwyd, PA 19004 Dear Madam/Sir: Re: Application #89-78P - installation of a building on the east side of Route 5 At the November 13, 1989 meeting, the Inland Wetlands Ag ncy/Conservation Commission approved with modifications Application #89-78P - IWA/CC permit for the construction of an industrial building on property located on the westerly side of John Fitch Boulevard, I zone, as shown on plans prepared by Palmberg &Russo, dated July 28, 1989, revised October 19, 1989, project #89065. 1. Black and white transparent mylars of sheets # 2 of 5 with the above modifications, together with two blueprint copies of the entire set of plans, must be submitted to this Commission to be stamped and signed. This must be completed within 65 days of approval prior to any construction activity on the site. 2. Construction activities shall be subject to the approval of the Town Engineer. 3. The application shall indemnify and hold harmless the Town of South Windsor against any liability which might result from the proposed operation or use. 4 . We recommend a bond in the amount of $6000.00 to be submitted to Planning and Zoning Commission to ensure compliance with the Erosion and Sedimentation Control Measures. 5. The permit is valid for one year and shall expire on November 13, 1990. 6 . All approvals required must be obtained and submitted priortoanyactivityonthesite. Gelco Space Page Two Application #89-78P November 14, 1989 7 . A contact person shall be identified directly on the plans. 8. The areas where existing loose debris is to be removed shall be stabilized. This may be accomplished by establishment of permanent vegetation or permanent organic mulching. 9 . The existing 6 .5' reinforced concrete pipes do not need to be realigned. This has been reviewed by the Town Engineer. Very truly yours, James A. Lombardi, Chairman Inland Wetlands Agency/ Conservation Commission JAL/pmm cc: Jerry C. Iazzetta, Town Engineer Marcia A.Banach, Director of Planning John R. Collins, Chief Building Official Planning & Zoning Commission L----- Palmberg & Russo, Land Surveyors and Professional Engineers 15 Barber Pond Road, Bloomfield, CT 06002 pow N sE,, COD s 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 f~ SOR•co AREA CODE 203/644-2511 November 20, 1989 M E M O R A N D U M TO:Marcia A. Banach, Director of Plann-ing FROM: Jerry C. Iazzetta, Town Engineer RE:Gelco Space Site Plan We have reviewed the revised drawings dated 11/16/89 for the Gelc ace Site Plan and have the following comment. 1 . My comment" - tober 23, 1989 concerning the roof leader not being defined ff&"&,. ,b,qen answered by the engineer with a note on the drawing "row ader-splash pad" and an expinai.Q "roof leaders to ou splash pad and drain onto pa rk-.x c area . However, the dra a, . still shows the roof lea derground, outletting onto 5 "`-V riprap. Both of these the same roof leader and are in conflict. Please have ti clear up this conflict. JCl/jsv cc: Michael J. Gantick, Director of Public Works P y 7_0 Sau ?d&"4.OtO c V 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 f'OSpR,Cpt AREA CODE 203/644-2511 29 November 1989 Mr. Joe Unlinowski Two Bala Plaza P. O. Box 7100 Bala Cynwyd, PA 19004 Dear Sir: re: Appl. #89-78P, Gelco Space Site Plan Westerly side of Route 5 south of Kimberly Driv We are pleased to advise that the Planning and Zoning Commission voted on 28 November 1989 to approve the above-referenced application for a site plan ofdevelopmentinaccordancewithDrawings #1, 31 4, and 5 dated 7-28-89 revised 10-19-89) and Drawing #2 dated 7-28-89 (revised 11-16-89) preparedbyPalmbergandRusso, Project No. 89065, and with the following modifications: 1 . Prior to commencement of any site work, a meeting must be held with Town Staff. 2 . No building permits will be issued until the final mylars have been file in the Town Clerk's Office. 3 . This application is subject to the conditions of approval of the Inland Wetlands Agency/Conservation Commission, including a bond in the amount of $6,000. 4 . An as-built plan is required prior to issuance of a Certificate of Occupancy per Section 4.13. 10 of the Zoning Regulations . 5. Footing drains are required if the building has a basement. 6 . A landscape bond in the amount of $1,000 is required and must be submitted prior to filing of mylars. 7 . All plans used in the field by the developer must bear the stamp and authorized signature of the Town of South Windsor. 8 . Demonstrate that existing uses meet parking requirements . 9 . Interplant evergreen trees along southerly border for screening; show proposed plantings on site plan. Mr. Jo Ulinowski 2- 29 November 1989 Black and white transparent mylars of Sheet #2 with the dbove modifications, tog th r with thr a blueprint copies of th entir set of plans, must be submitt d to this Commission within 30 days to be stamped and signed. The lett rs of approval of this Commission, as well as the Inland Wetlands Agency/Conservation Commission, must be reproduced on the mylars . After the mylars have been signed by the Commission, they will be returned t you for filing in the Office of the Town Clerk within 90 days. After filing thes plans, a copy of the receipt must be submitted to the Planning Department. Very truly yours, PLANNING AND ZONING COMMISSION Loui a C. Evans Chairman cc: Inland Wetlands Agency/Conservation Commission M. Banach, Planning Director J. Collins, Chief Building Official J. Iazzetta, Town Engineer F. Shaw, Supt. of Pollution Control E. Belleville, Assessor W. Lanning, Fire Marshal Registrar of Voters Engineer Applicant PZC File AowN Be 0-1s e w 1540 SULLIVAN AVENUE . SOUTH WINDSOR. CONN. 06074 R-co AREA CODE 203/644-2511 TO BE PUBLISHED IN THE JOURNAL INQUIRER SATURDAY, DEC. 2, 1989 LEGAL NOTICE TOWN OF SOUTH WINDSOR PLANNING AND ZONING COMMISSION At its Nov. 28, 1989 meeting, the Planning an o ' ssion voted to take the following action: 1 . Approve, with modifications, pl. #89-78P. Ge o Space, for a site plan of developm for propert the westerly side of Route 5 (John Fitc Bo utherly of Kimberly Drive, I Zone. 2 . Approve, with modifications, Appl. #89-73P, Peter D'Engenis and Amin Sabbagh/Hartford Prospect Industries, for a site plan of development for Lot 3 on the southerly side of Kimberly Drive, westerly side of John Fitch Boulevard, IP Zone. 3 . Approve a motion to accept applicant's 65-day extension request for Appl. #89-72P, 641 Sullivan Avenue Associates subdivision, 641 Sullivan Avenue, RR Zone. Dated at South Windsor, Connecticut this 29th day of November, 1989 . PLANNING AND ZONING COMMISSION Louise C. Evans, Chairman Bernard Hart, Secretary Put your address in the"RETURN TO"Space on the reverse side. Failure to do this wol prevent thiscardfrom6, ing returned to you. For add t an a. poetmaster for fen and*hook box a'al for additional service(m)requasmed.1. O Show to whom delivered,,date,and addressee's address. 2. O Restrktad Deliveryt(Bxtm r1 vii)t t Exdis clyrse t SWAlkle Addressed to: 4. Article Number TO C v Ll NO w r-- C 4-C-0 llljlc Type of Service: Insured Certified, COD 4 Always obtain tip uture of addressee or spent and DAME DELIVERED. n S. Addressee's Address(Oft t V requested and fee p&4 xw=r.—Assent 7. Date of Delivery DE-C 11 9 ow mm sit.. i 4440*- A 4 r Tia aleS d&U&Ote 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 4soe•co AREA CODE 203/644-2511 RE: Preconstruction Meeting - January 12, 1990 Application #89-78P Gelco Space IN ATTENDANCE Name Company/Address Telephone # Michele R. Lipe Town of South Windsor 644-2511 John E. McCahill Town of South Windsor 644-2511 Jerry C. Iazzetta Town of South Windsor 644-2511 John Costas Gelco Space 215-687-4240 989 Old Eagle School Road Wayne, PA 19087 Bob Richards R.F. Richards GC 677-6997 7 Beacon Heath Road Farmington, CT 06032 Bob Guarente Gelco Space 763-0825 244 Shaker Road Enfield, CT 06082 The following is a brief summary of points discussed during the meeting. Erosion & Sedimentation Control 1. All erosion and sedimentation control measures are to be in lace prior to earth moving operations in each area and maintained cleaned out during construction. Call Zoning Wetlands Enforcement Officer for inspection when measures are in place, prior to commencement of site work 2. All topsoil stockpile areas to be protected (ringed with haybales or equal) . 3. During construction of the road/driveway routine sweeping of the parking lot will be required to minimize tracking of dirt/gravel onto John Fitch Boulevard. Calcium chloride or water is to be used for dust control as required. Public Works 1. Only approved plans are to be used on jobsit . 2 . The Public Works Department is to be notified forty-eight 48) hours prior to the start of major construction work with inspections and testing per Developers Checklist required for the following: a) after site is staked out b) all drainage work c) Preparation of subgrade, compaction tests as required by the Town. d) Preparation of subbase, six (6) inch lifts e) Placement of bituminous concrete, 2 inch layers. 3 . Certification of gravel used as subbase will be required by an approved testing company. 4 . No subgrade formation/base in frozen ground/snow. Same for pipe/structure installation. 5. As built plans are to include horizontal and vertical location of all underdrains, footing drains, and sanitary sewers located by a certified land surveyor. 6 . All pipe and structures to be backfilled with free draining material, compacted in maximum one foot lifts with approved compaction equipment. Any pipe or structure work requires inspection prior to backfilling. 7 . Any problems and/or questions regarding construction of this project will be directed to John Costas in the field. 8 . All filling to be done in accordance with Department of Transportation specifications. To be compacted in maximum lifts and tested as necessary. 9 . Job meetings will be held as needed, and can be called by the developer or Town. 10. Forty-eight (48) hours notice needed for Certificate of Occupancy inspection. Two week review period (10 working days) needed for all individual site (lot) plans prior to issuance of building permit (may be longer if application is incomplete) . See General Guidelines for Certificat of Occupancy and Building Permit. 11 . Any proposed changes are to be presented to the Engineering or Planning Department prior to implementation on change sheet in triplicate. Town will attempt to turn around within 24 hours . 12. DOT Permit needed for all work within state road. Copy to the Planning Department. 13. No paving after October 15 without written approval from Director of Public Works. 14. Normal hours of operation 7:00 A.M. - 5:00 P.M. , no work on Sunday. Planning Department: 1. Bonds are still needed. 2. Mylars to go on file in Town Clerk's office after bonds have been received. W.P.C.A. 1. Notify Collector of Revenue as to the incremental increas of the developed acreage for the purposes of calculation of sewer connection charge. SNET/NU 1. Contact utilities for coordination of utilities connection. IWA/CC 1 . The areas where existing loose debris is to be removed shall be stabilized. This may be accomplished by establishment of permanent vegetation or permanent organic mulching. 2. Need $6,000.00 bond to ensure compliance with the Erosion and Sedimentation Control Measures. Fire Marshal 1. Blasting (if required) to be coordinated with the Fire Marshal. Police Departm nt: 1 . Emergency phone numbers for the duration of the construction must be provided to the Police Department on a company letterhead. If the developer occupies or owns the building/s after construction emergency numbers must be provided to the Police Department. 2. Erect temporary sign on the site during construction identifying the project. 3. If an alarm is to be installed contact the Police Department. 4 . Required that street lights be installed on SNET Co # pole numbers 1686 + 1958 with 100 watt H-P Sodium. Building Department: 1 . Plan review with Building Official/Fire Marshall required prior to application for building permit. Coordinate with Chief Building Official. Very truly yours, Michele R. Lipe Assitance Planner/Analyst MRL/pmm cc: Jerry C. Iazzetta, Town Engineer Lester A. Braddock, Sr. Engr. Inspector Thomas Hart, SWPD Karl Reichle, Public Works Mel Stead, Public Works Minh V. Le, SNET Hal Clisby, CL&P John R. Collins, Chief Building Official Fred Shaw, Superintendent of Pollution Control John E. McCahill, Zoning Enforcement Officer John Costas Bob Richards Bob Guarente TOWN OF SOUTH WINDSOR STAFF SITE CHANGE j FOR SITE i SUBDIVISION GENERAL: o'e a 7CPJ CHANGE ORDER CONTACT PERSON Phone No. Sit Name_EAST jh:ag oaP f,T 6 P&Z No.-p q-78 A Own r T'N IAb i4e"Ra v e d ftq LT le Phone No, 2,7. 82 7Q. Contractor_ WIAW 5a6NMj&WTjvfjv Signature of Owner IA Date:_lZO1gp Signature of Design Engr, Date: 1 Ito 14 CHANGE: (Describe location nature of change. Include plan/profil of Change) . REws- ®Ic Nlo wit t3Vo IJpwj[, •. Mari c A p"x. 4!V'' Feavu~Ao Reason for Change: (Why is -change required) T00'-oll) 'Wrr#4 TNE; 1 9S'To LI.,Nn%4 OF 2C.k nge-e. . APPROVALS: (As Required) Dir. Of Planning 6Date: v Town Engineer Date:— Dir. of Public W rk Date: Oth rs Date: STAFF COMMENTS: cc: D puty Town Engineer Zoning Enforcement Officer Chief Building Official t 1 IJ FED 40 South Windsor INLAND WETLANDS AGENCY CONSERVATION COMMISSION TOWN OF SOUTH WINDSOR STAFF SITE CHANGE FOR SITE & SUBDIVISION GENERAL: CHANGE ORDER CONTACT PERSON John Costa Phone No. 215-687-4240 Site Name Gelco Space P&Z No. Owner Gelco Space Phone No. 215-687-4240 Contractor Winn ' s Construction Inc. Signature of Owner ! Date: March 5, 1990 Signature of Design Engr. Date: March 5 „ 1990 CHANGE: (Describe location az,4 nature of change. Include plan/profile of Change) . 1 ) Moved pumping station into grassed area out of paved area. 2 ) Changed entry in to manhole as requested by inspector. Reason for Change: (Why is . change required) 1 ) Pumpnca station had to be in grassed area. 2 ) Inspector request APPROVALS: (As Required) Dir. Of Planning 40::LDate: Town Engineer. Date: 3"• '! C Dir.. of Publi W ks Date: Other: Date: STAFF COMMENTS. cc: Deputy Town Engineer Zoning Enforcement Officer f r Chief Building Official pwr Of 40 K_ ; Rana A;, N i`SNP QF„/v1OVi:, r 2:EPrlArrt, M47z 4 70 Fjcr,T. O GRACE r----_-- PRivfICY Sc.AT.S 1pyA: c 00O r 11/111/111/ /11111 P C aIVK/ aN ) M 11l1/111 1111111 1111 r. •:;.ITN ,PCT•IV WvB re 0P4 Ay 774CL)Sr Ex I e h - 76 , PV r: 30U'8K'"ZV w G 70 i4 NFrCoC44Aft. S t5rlN61 MAPS i. F i i qu w/SRX.K-ACE o,Z N6135 7 8 4. 51"W FMV S C.JVVvi/V+ TOWN OF SOUTH WINDSOR STAFF SITE CHANGE FOR SITE i SUBDIVISION GENERAL t CHANGE ORDER CONTACT PERSON Phon No..( 14 Lj--ZS j Site Name emT &Je OTg P&Z No._ 9q_2g'P_ Own r 3 r eneraTo oei a6jrq Phone No. 527,-j?2,-)y Contractor VS TYZvC1 ) ,40 - Signature of Owner VaAll Dates 7 Signature of Design Engr. Date: :Z& CHANGE: (Describe location a nature of change. Include plan/profil of Change) . ocwre— '-De-c-L -cqi8, P-ao42 51-roM Or T•V R ason for Change: (Why is -change required) e eO r APPROVALS: (As Require ) Dir. Of Plannin Date: Town Engineer Date:y Dir. of Public W rk Date: Oth r: D6Ltes STAFF COMMENTS: cc: Deputy Town Engineer Zoning Enforcement Officer Chief Building Official 1 ! 4PIALL j0 a 1W ddP iwc Ali l c1f.H of Pw WAW 0'0M at+< y r 710 Ole d&,o c s 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 soR•co' AREA CODE 203/644-2511 March 12, 1990 Gelco Space 1451 John Fitch Blvd. South Windsor Conn. 06074 To Whom It May Concern Please be advised that beneficial occupancy is hereby granted for the Modular Office Building erected under Building Permit 18274, as provided by Connecticut General Statute 29-252-119 .5. The permanent Certificate of Occupancy will be issued upon submission and approval of an "as-built" site plan, and receipt of an affidavit of final cost. This occupancy is granted for a period of sixty days, and will expire May 15, 1990. Please be advised that any changes in the building which constitutes a violation of the conditions of the permit will result in revocation of this approval. Sincerely John R. Collins, Chief Building Official cc: Marcia Banach, Director of Planning Jerry Iazetta, Town Engineer s r 7-0 ap sioa W •u 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 Coe AREA CODE 203/644-2511 September 11, 1990 Planning & Zoning Commission 1540 Sullivan Avenue South Windsor, CT 06074 Dear Madam/Sir: R : Bonds At th S ptember 10, 1990 meeting of the Inland Wetlands Ag ncy/Conservation Commission, it was voted to release the following bonds: Application #381, Abbe Road Estates in the amount of 10,000 .00. Application #89-33P, Atlas Oil/Oakland Road in the amount of 5,000.00. Application #89-18P, Capitol Steel in the amount of $5,000.00. Application #87-487, Covensky Industrial Building in the amount of $3,000.00 Application #294, Evan's Crossing in the amount of $15,000.00. Application #89-30P, Franklin Distributors in the amount of 5,000.00. Application #89-27P, Gerber Scientific in the amount of 10,000.00. Application #88-45P, KF Brick in the amount of $5,000.00. Application #87-396, Reliable Refuse in the amount of 2,500. 00. Application #89-37P, Savings Bank of Manchester in the amount of $2,000.00. Application #373, Terlizzi, Lot 6 & Subdivision in the amount of $10,000 .00. Application #379, Tri-State Laundries in th amount of 5,000. 00. Application #88-107P, Vintage Homes (Foster. - 2 lots) in the amount of $2,000. 00. Application #88-31P, Waldo Brothers in the amount of 5,000 .00 . Application #89-78P, Gelco Space in the amount of $6,000.00. Application #405, Knoek Hardware in the amount of $2,000.00. Application #208, Quality Electric in the amount of 2,500 . 00. Press Services in the amount of $2,000.00. Application #89-74P, Boat Works Marine Storage in the amount of $5,000. 00. Va.y truly yours, J/ es A. Lombardi Chairman Inland Wetlands Agency/Conserva ion Commission JAL/pmm cc:Marcia A. Banach, Director of Planning Jerry Iazzetta, Town Engineer Michele Lipe, Ass't Planner/Analyst SE,` C r 710 o-P Saum Veu s 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 060744 4soe-co, AREA CODE 203/644-2511 14 September 1990 Mr. Joe Unlinowski Two Bala Plaza P.O. Box 7100 Bala Cynwyd, PA 19004 Dear Mr. Unlinowski: re: Gelco Space 6,000 IWA/CC Bond. This is to advise that the Planning and Zoning Commission voted on 11 September 1990 to release the IWA/CC Bond. Advance arrangements should be made to pick up the bond to ensure that the necessary contact person(s) will be available. If you have any further questions contact the Planning Department at 644-2511, Ext. 251 . Thank you. Very truly yours, PLANNING & ZONING COMMISSION Marshall Montana Chairman cc: J. Iazzetta, Town Engineer M. Banach, Director of Planning PZC File CHUBB GROUP OF INSURANCE COMPANIES CHIJBB 100 William Street, New York, New York 10038-4568 Bond No. 8126-15-08 Amount $1, 000. 00 KNOW ALL MEN BY THESE PRESENTS, That we, Gelco Space, A Division of Transport International Pool, Inc. , Two Bala Plaza, Bala Cynwyd, Pa. 19004 (hereinafter called the Principal) , as Principal, and the FEDERAL INSURANCE COMPANY, of 15 Mountain View Road, Warren, NJ, a corporation licensed to do business in the State of Connecticut, (hereinafter called the Surety) as Surety, are held and firmly bound unto Town of South Windsor, South Windsor, CT 06074 (hereinafter called the Obligee) , in the sum of ONE THOUSAND AND 00/100------Dollars ($1, 000. 00) , for the payment of which we, the said Principal and the said Surety, bind ourselves, our heirs, executors, administrators, successors and assigns, jointly and severally, firmly by these presents. Sealed with our seals and dated this 12th day of January A. D. nineteen hundred and ninety. Whereas, the said Principal is required, under application #89-78P Palmberg & Russo Project #89065 Drawings #1, 3 , 4 , and 5 Dated 7/28/89 (Revised 10/19/89) and Drawing # 2 Dated 7/28/89 (Revised 11/16/89) , to comply with Landscaping Requirements As Set Forth By the Planning and Zoning Commission, and Whereas, the said Principal is required to file this bond with said Obligee to guarantee satisfactory completion of said improvements. Now, Therefore, the condition of this obligation is such that if said Principal shall complete said improvements in conformity with the specifications of the said Obligee then this obligations shalli be null and void otherwise shall remain in full force and effect. GELCO SPACE, A DIVISION OF TRANSPORT INTERNATIONAL POOI, TNC. BY. 3P 0 t Y: AL I RANCE COMPANY chard G. HighsistantSecretary POWER OF ATTORNEY Know all Men by these Presents,That the FEDERAL INSURANCE COMPANY,IS M untain Vi w Road,Warr n,New Jersey,a N w Jersey Corporation, has constituted and appointed,and does hereby constitute and appoint Richard G.Hight,Assistant Secretary,Gloria Warrick,David B.Norris,Jr.,Anna Maria Lovecchio,Robert Ogle,Maria Scardigno,Earn stine Porter,H Ion S.Brown,Lydia R.Schorr,Richard A.Ciullo,Mark M.Bak r,Dekk r M.Buckl y,Michael Heningburg,Jr.,Greg Kuruvilla,Edward J.Reilly,John J.Barry,Christ pher E.Painter and Matth w R.Young of New York,New York each its true and lawful Attorney-in-Fact to xecute under such designation in its name and to affix its corporate seal to and deliver for and on its behalf as surety thereon or otherwise, bonds r obligations given or executed in the course of its business,and any instruements amending or altering the same, and consents to the modification or alteration of any instruments referred to in said bonds or obligations. In wNrises whereof,the said FEDERAL INSURANCE COMPANY has.pursuant to Its By-Laws,caused thew preesnis to be signed by Its Via President and Aaalatam Seastary and Its corporate seal to be hereto afford this 1st day of April.1989. Corporate Saw gItANr p' tW 0 yf ERSEYJ FEDERAL INSURANCE COMPANY By James D Dixon Richard D.O'Connor Assistant Vim President Assistant Secretary STATE OF NEW JERSEY SS.County of Somerset On this first day of April,1959,before me personalty came Richard D O'Conrwr to ere known and by me known to be Assistant Secretary of the FEDERAL INSURANCE COMPANY,the corporation described In and which executed the foregoing Power of Attorney,and the said Richard D.O'Connor being by me duly sworn,did depose and say that he ati Assistant Secretary of the FEDERAL INSURANCE COMPANY and knows the corporate seal thereof,that the seal affixed to the foregoing Power of Attorney a such corporate seal and was thereto affixed by authority of the By-Laws of said Company,and Chet he signed said Power of Attorney as Assistant Secretary of said Company by like authority:and that he a acquainted with James 0 Dixon and knows him to be the vice President of said Company,and that the aignitturs of sod James D.Dixon subscribed to said Power of Attorney a in the genuine handwriting of said James D.Dixon and was thereto subscribed by authority of saki By-Laws and in deponenI's presence Notanal Seal Ack ce ledge and Swom to before me L E an the data above written Q NOTARY PUBLIC Z- Notary Public J E A 5 ALICE LEONARD NOTARY PUBLIC OF NEW JERSEY My Commission Expires July 12, 1993 NOTARIAL ACKNOWLEDGEMENT CITY, COUNTY 8 STATE OF NEW YORK, ss On this 19rl, day of wary 1e 90 before me peaty u Richard G. Hight, Assistant Secretary to me known,who,being by me duly sworn,did depose and say that he is an A94fN&act of the FEDERAL INSURANCE COM- PANY,the Corporation downbed in and which executed the annexed instrument,that he knows the corporate seal:that it was so affixed by order and authority of the Board of Directors of said corporation,and that he signed his name thereto by like order and authority Swom to and Acknowledged before refs on the date written Z Notary's Signatu ,Descnption and Seal) HELEN S. BROWN NOTARY PUBLIC, Stat of New Yo& No. 31-4382129 Qualifi d in Idew York County DCommissionExpiresDcembr31, 1990Form21.1"344(Rio 449)METRO SPEC'e9 OVER CERTIFICATION STATE OF NEW JERSEY County of Somerset I,the undersigned.Assistant Secretary of the FEDERAL INSURANCE COMPANY,do hereby certfty that the following is a true excerpt from the By-Laws of the said Company as adopted by its Board of Directors on March 11.1953 and most recently amended March 5,1996 and that this By-Law is in full force and effect ARTICLE XVIII Section 2.AM bonds.undertakings,on bacb and other instruments other than as above for and on behalf of the Company which it is autfrorized by taw or its charter to execute,may and shall be executed in the name and an behalf of the Company either by the Chairman or the Vice Chairman or the President or a Vice President,jointly with the Secretary or an Assistant Secretary,under their respective desiprtatrons,except that any one or more officers or attorneys-4n-fact designated in any resolution of the Board of Directors or the Executive Committee,or in any power of attorney executed as provided for in Section 3 below,mad,execute any such bond,undertaking or other obligation as provided in such resolution or power of attorney. Section 3.All powers of attorney for and on behalf of the Company may and shall be executed in the name and on behalf of the Company,either by the Chairman or the Vice Chairman or the President or a•Vice President or an Assistant Vice President,jointly with the Secretary or an Assistant Secretary,under their respective designations.The signature of such officers maybe engraved,printed or lithographed The signature of each of the following officers:Chairman,Vice Chairman,President,any Vice President,any Assistant Vice President,any Secretary,any Assistant Secretary and the seal of the Company may be affixed by facsimile io any power of attorney or to any certificate notating thereto appointing Assistant Secretaries or Attorneys-in-Fact for purposes only of executing and attesting bonds and undertak- ings and other writings obligatory in the nature thereof,and any such power of attorney or certificate bearing such facsimile signature or facsimile seal shall be valid and binding upon the Company and any such power so executed and certified by such facsimile signature and facsimile seal shall be valid and binding upon the Company with respect to any bond or undertaking to which it is attached" I further oertiy,that said FEDERAL INSURANCE COMPANY is duty licensed to transact fidelity and surety business in each of the States of the United States of America,Dtstnct of Columbia,Puerto Rico,and each of the Provinces of Canaos with the exception of Prince Edward Island.and is also duly licensed to become sob surety on bonds,undertakings.etc.,permitted or required by law I,the undersigned Assistant Secretary of FEDERAL INSURANCE COMPANY,do hereby certify that the foregoing Power of Attomey is in full force and effect Given under my hand and the seal of said Company at warren,N.J,this 12th ay of January 19 90 Corporate Seal M4_ZT SVIt IVL Assistant secretary r Cb Is ey'••»...• y Financial Statement of Federal Insurance Company as of December 31, 1988fh'JElk IN THOUSANDS OF DOLLARS STATUTORY BASIS LIABILITIES AND ASSETS SURPLUS TO POLICYHOLDERS United States Treasury Bonds. . ... .. . . . $ 551,842 Outstanding Losses and Loss Expenses . $ 2,307,420 United States Government and Federal Uneamed Premiums....... . ....... . .. 810,636 Agency Guaranteed Bonds .... ...... 205,197 Accrued Expenses . ........ .. ... ... .. 68,750 State and Municipal Bonds . ... ........ 1,634,541 Non-Admitted Reinsurance ... . .... ... . 25,234 Other Bonds ...... ... . .... ... . . ... .. 312,407 Dividends to Policyholders. .. .. .. . .. . . . 21,543 Common Stocks .. . . ... .... . . . . . .. . . . 209,389 Loss Portfolio Transfer. .... . ... .. . ... .136,774) Preferred Stocks....... ..... . ... ... . . 1,010 Other Liabilities...... . . ..... . ... . .. . . 179,885 Other Invested Assets .. . . .. . . . ... .. . . 46,285 Short Term Investments. . . . . . . . .. . . .. . 38,973 TOTAL INVESTMENTS . ... .. ... . ... 2,999,644 TOTAL LIABILITIES . . . . . . . . . . . . ... . 3,276,694 Investments in Affiliates: Common Stock . . .... ... . . .. . ... .. . . . 13,987 Vigilant Insurance Company . . ... .. .. 123,470 Paid-in Surplus .. . ... . . .. . . .. . . . . . .. . 561,253 Great Northern Insurance Company ... 48,206 Pacific Indemnity Company .... . ... . . 244,254 Unassigned Funds . .. . .. .. . ... . . ... .. 498,772 Chubb Life Insurance Company .. . . .. 175,766 Unrealized Appreciation of Investments . . 269,136 Bellemead Development Corporation . . 290,252 Chubb Insurance Company of Canada . 49,876 Other . . . ... . . . .. .. . ... . ... ... .. . . 43,314 Cash 15,039 SURPLUS TO POLICYHOLDERS .. . . . 1,343,148 Net Premiums Receivable ... ... . . .. . . . 453,784 Reinsurance Recoverable on Paid Lsses .. . ... . . . . .. .. . . . . .. . . . .. .. 64,164 Other Assets .... .. . ... . . ... . .... . . . . 112,073 TOTAL LIABILITIES AND SURPLUS TOTAL ADMITTED ASSETS . . . . . . . . . $ 4,619,842 TO POLICYHOLDERS . . . . .. . . . . . . $ 4,619,842 Investments are valued in accordance with requirements of the National Association of Insurance Commissioners. Investments valued at$11,047 are deposited with government;authorities as required by law. AirrrEr