HomeMy WebLinkAbout140 Overlook RoadNy.4Y"r&T h*"Y..a
42-30 70
Application No. Permit No. .
TO THE BUILDING INSPECTOR
of the
TOWN OF SOUTH WINDSOR, CONN.
hereby make application for a permit to (erect (Mlw Appolims) a building according
to the following detailed statement of the specifications and plans herewith submitted. (Draw a line through
word "erect" or words "make alteration to" as the case may require.)
All provisions of the Building By-Laws (Sections 2 to 32 inclusive) shall be complied with in the execu-
tion of this work whether specified herein or not.
South Windsor, ConN.Av e....... .............
Sign hen ..:
Address 14.4 ...............
Location? . ... . ............ side of?
Nearest cross street? ........ 4........... ....,..................Street No. ... ........... .............................. Lot No. .......
Owner of land is?+E?.J.1' ... 11.. . i.t Address /.. .....Q..... .C2W.e.7.'..... .A.1 '......
Owner of build' ' ? .. ''`Address ... ....... %`.......
M`
y . .-AddressArchitectis? ..T........
Bn;;''-r is. /'P Address /.... o. .00 .1a .., w.......1 ........
ensions of building?4...k3.2.....Feet front? .............. ... ........... Feet rear? ................ deep'........... poet . .........................
17 Extreme height to highest point of roof? ........?
0.0
No. of stories in height?...................... ............
Purpose of building b it,.,?f.. j._.No. of stores? .......................... .......................................................I...................
Howmany families? ........................... No. of ro .s? .... ...............................................................................................
Distance from street line is? . from building line is? ....................... .......................................................
ADDITIONS AND ALTERATIONS
Give Brief Description)
7 Q ..............................................................
w .....................
AA . ....
Map No. .... ......,
If of steel frame, what is exterior construction?
What kind of columns used? . Size of columns used?
What length of columns used? . How protected?
What kind of beams or girders? Size of beams or girders?
Longest span of beams or girders? These rest on?
Roof construction is? .. ..Roof covering is?
The floors are of ... . construction and are calculated to carry a safe load of
lbs. per square foot.
See Section 14, Building By-Laws.)
BRICK CONSTRUCTION.
Of what material will walls be constructed?
Composition of mortar? . .... ..
Height and Thickness of Walls
He*ht Stories Front Walls Side Walls Rear Walls Partition Walls
Basement,
1st Story
2nd "
3rd "
I........ ......... ...
4th "
5th 14
6th "
7th "
8th
9th "
10th "
Material.of Front? If stone, what kind?
Thickness of Ashlar? Thickness of Backing?
Backed up with what? Arches or lintels over openings?
t '`rid yw ,_ "
Y;'^
p> ex" .-eZ:'" ` 'i "'',G a i„ a„';`'"^."r Fc; 'i<t',;T#:a ^••,tr,_,, .,s, ,w`- s"...
y ;
r?- nz'ZeM.
F.„ r ..p' i,, ^..F, `
s xs ; raw ,, n,.,r+••, Fu3 }.
i 4^;,9:,3?qy,- t_',,4 G,F`hx,'v •„i;u.'` t'`.,,.,_ ,. ^""r.r c ,3' t
x
Y Y&,, _ 1¢"t-.tsdttpf= 4,yh rY j' 'rvS„ a ''l -a`v\' i ,,
j
T4,d .tf _ 4•u,'
a f''4 i 9
g.:.'„ ,C#` ry - ..c ^
L
C - .. -_ _ , ,,. * SI'
Y `
t R4' '_
2 'k,',' $:. N.'
b
i
m
F y
a
J f•
F."(.fie?4b.sy„i,y°'°'." .'"'x'
v,'
a^.'k"Mtt,(p
r
n•. , 'Nye`--.v=-:'i 4't- ';'a`. __ ^,t`t„
g11Yw..TT SL
1
116"A BPM
ut
r•"" .r....N.w •....rrw wrwwar.wwaar.waw...aa ..N.wr.Nr •.amw............ —
wa.... q ................ .w•waN.....NNN.r.N.ww... q.M.w.NNa. w...•u...w.w..q .. w. q...Nq..N.N aHw.w.w..gNw a
ww..........wwa....a.a..w qqw a...w.w.wa..r.q.. N r.q..N..W.q.
Size of outside studs? ......................................... Distance an centres? ............_.................................. S6 oriA? .......... ..w....w..N.r ....N.
ry :...
Size of rafters? .......................................... Dim= an centres?................................................... Size of plate? ......................................................
Sizeof ledgers or gins? ................................................................................Size of deck rafttrs? ............................._................w.............w..N .............N
Distance on centres? .............. .....................................................................Size of studs in bearing partitions? .................................._............N
MISCELLANEOUS
Style of roof, flat,.pitch, Mansard, or hipped? ............................ ................................. Fireplaces? ........................................................
Materialof roof-covering? .................................................I...................Material Of Cormce? .....................................................................................w
Howis building hated? ............................................................................Lining of flues? .. ............................................................................... ..............
Thickness of shell of flues? ..Any elevators or lifts? .......................................................... ......................
Whatkind? ................ ........ .... ........... How many? .... . . ... ...... .............. Any hoistways? ....... .... .. ........... ............... .
00
Howprotected? ..... . ............................... ....... .... .................Total Value of Building ... .. Q4......................................
n t i
When will work be commenced? ..
The applicant warrants that the lot for residential purposes, shown on a plot plan accompanying this
application, conforms to the zoning regulations of the Town of South Windsor.
Town of South Windsor since 1949.
g L R,
Applicant
3970
BUILDING APPLICATION
Application No. .. l;2 0
on the ... ................. . aide of
Overlook , .
Street.
Street No, 10
Owner J o'la n R. B u t t
Applicant S are e
CLASSIFICATION
Buster (J"rabbe
161X321
Permit issued on above Application.
Date, j.une 4 5 .. . 1962
5.. ,..i G.'+". - P:i•..,c-.u TijSF F-'4
i.T _ 1
TOWN OF SOUTH W
B=ING PERMIT
Date June 4 19 t
Fee Paid $4..OQ*-, Eat. Value $
71
Permit N9 - - 9 7 Q w 1015
on th orth sine 4
Overlook Rd.
140 r=
Street No.
John R. Butt
Owner
Same
Applicant
CERTIFICATE OF OCCUPANCY ISSUE:
Date
No. i
Fee Paid r. :
jI,, .
i CLASSIFICATION y..x•.f,,:-.': .-
1 8_- Fes•- .
Buster Crabbe Swimming Pool
Y
BUILDING PERMIT
N® 3970
OFFICE OF
THE BUILDING INSPECTOR
of the
Town of South Windsor, Conn.
South Windsor, Conn. June 4 V 1962,
T4'to to to Terftf1j, That John R. Butt
is hereby granted permission to RusterCrabbe '.wimminE i'ool 161x321
at estimated value of $3,8roeo_
on the
N
side of
North
side Overlook Ed. Street on land
owned by
John ri. Putt
Said Work to be as described in Application
No. 4230 and to conform to specifications and plans filed with said Application, and Building By-
Laws of THE TOWN OF SOUTH WINDSOR.
Issue' JgPelk a 19 d2
Building Inspector.
Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers
during the day and by both barriers and colored lights by night.
SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place
or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a
license therefor from the city or borough in which such highway may be situated, he shall pay said city,
town or borough all costs and damages which it shall sustain, or be compelled to reason therefor."
Iqel
TO THE BUILDING INSPECTOR
Of 11116 $ /9.a- APPLICATION FOR
PLAN EXAMINATION ANDTO" OF SOUTH W COI iN• BUILDING PERMIT
z
IMPORTANT — Applicant to complete all items in sections: 1, 11, Ill, IV, and IX.O
ZONING
I• AT (LOCATION) f yEk u Ili d DISTRICT
LOCATION NO.) STREET)
OF BETWEEN AND
BUILDING CROSS STREET) CROSS STREET)
LOT
SUBDIVISION LOT BLOCK SIZE
N
II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D o
A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use M
1 New building Residential Nonresidential
2 Addition(If residential, enter number 12 One family 18 Amusement, recreational
of new housing units added, if any,
in Part D, 13)13 Two or more family — Enter 19 Church, other religious
number of units— — — — •--)P. 20 Industrial
3 Alteration (See 2 above) 14
4 air, replacement
Transient hotel motel 21 Parking garageReppordormitory — Enter number
5 Wrecking (IJ multifamily residential,of units ——————— — •••ir 22 Service station, repair garage
enter number of units in building in 15 Garage 23 Hospital, institutional
Part D, 13) 16 Carport 24 Office, bank, professional
6 Moving (relocation)17 Other — Specify 25 Public utility
7 Foundatien only 26 School, library, other educational
B. OWNERSHIP w.-9I27 Stores, mercantile
8 dPrivate (individual, corporation,
28 Tanks, towers
nonprofit institution, etc.) 29 Other — Specify
9 Public (Federal, State, or
local government)
C. COST Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g., food
processing plant, machine shop, laundry building at hospital, elementary
10. Cost of improvement................ school, secondary school, college, parochial school, parking garage for,
department store, rental office building, office building at industrial plant.
To be installed but not included If use of existing building is being changed, enter proposed use.
in the above cost
a. Electrical.......................
b. Plumbing ......................
c. Heating, air conditioning.........
d. Other (elevator, etc.)............
11. TOTAL COST OF IMPROVEMENT S 3poo.
III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L;
for wrecking, complete only Part J, for all others skip to IV.
E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS
30 Masonry (wall bearing) 40 Public or private company
48• Number of stories................
31 Wood frame 41 Private (septic tank, etc.) 49• Total square feet of floor area,
all floors, based on exterior
32 Structural steel dimensions ....................
33 Reinforced concrete H. TYPE OF WATER SUPPLY
34 Other — Specify 42 Public or private company
Total land area, sq. ft. ...........
43 Private(well, cistern) K. NUMBER OF OFF-STREET
PARKING SPACES
51. Enclosed ......................
F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL
35 Gas Will there be central air 52. Outdoors.......................
96 Oil conditioning? L. RESIDENTIAL BUILDINGS ONLY
37 Electricity 44 Yes 45 No 53. Number of b drooms..............
38 C al
39 Other— Specify Will there be an elevator?
54. Number of
Full..........
46 Yes 47 No bathrooms
Partial.......
NOTES and Data — (For department use)
P
IV. IDENTIFICATION — To be completed by all applicants
Name Mailing addr ss — Number, street, city, and State ZIP code Tel. No.
Owner or A KA-J ate Q7516 S4a3r
Lessee j w
2. LAZ&
e MQ4:,z
Contractor
3.
Architect or
Engineer
The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction.
Signature of applicant Address Application date
v, 0-) 3e4 11 IS--71
00 NOT WRITE BELOW THIS LINE
V. PLAN REVIEW RECORD — For office use
Plan Review Date Plans Date PlansPlansRviewRquiredCheckFeeStartedBYApproved By Notes
BUILDING
PLUMBING
MECHANICAL
ELECTRICAL
OTHER T-t
VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS
Permit or Approval I Check Date Number B Permit or ApprovalI Check Date Number BppObtafinedYppObtained Y
BOILER PLUMBING
CURB OR SIDEWALK CUT ROOFING
ELEVATOR SEWER
ELECTRICAL SIGN OR BILLBOARD
FURNACE STREET GRADES
GRADING USE OF PUBLIC AREAS
OIL BURNER WRECKING
OTHER OTHER
VII. VALIDATION
Building
P rmit numb r 10602
Bui Iding
Permit issued Nov. 20 1978
Bui Iding
Permit Fee $ 18.00
Approved by:
i
TITLE
VIII. ZONING PLAN EXAMINERS NOTES
DISTRICT
USE
FRONT YARD
SIDE YARD SIDE YARD
REAR YARD
NOTES
IX. SITE OR PLOT PLAN — For Applicant Use
41
r ' -._!
N
a-u< O wg.Y•e-.m-ate-.B,br a-^.^B< -4Qe'$>.<„p`,m,,,n,w
b _
a-,r pw,_^a ,<4 i i"-.:r m m F` Y N `r F> _ t < _, F'R`.«„
a_ R
P1 f °'Y a 4 L k P £
i
I
T
T
TOWN OF SOUTH WINDSOR
BUILDING PERMIT
Date Nov. 20 19 78
Fee Paid $. J 8 00 Est Value . 3,000.00 y
Permit N° 10602 V
on the side of
Overlook Road Stcea
Street No.140
Owner Horace Minnef iel d
Applicant Francis H. Te t raul _ M
CERTIFICATE OF OCCUPANCY ISSUED:
Date
NO.
Fee Paid $
CLASSIFICATION
Vinyl Siding
BUILDING PERMIT
N9 10602
OFFICE OF
THE BUILDING INSPECTOR
of the
Town of South Windsor, Conn.
South Windsor, Conn.Nov• 20 19 78
94is is ftt (9rrfifV, That Horace TPt-ru,111- & In.
is hereby granted permission to Vinyl SiOl itZ
at estimated value of O
on the side of-- 1-4 Overlook Ro d Street on land
owned by Horace Minnef ield
Said F.Yo rk to be as described in Application
No. 1 0 40 2 and to conform to specifications and plans filed with said Application, and Building By-
Laws of THE TOWN OF SOUTH WINDSOR.
IssueA A 19 7 8.
auilding Inspector.
Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers
during the day and by both barriers and colored lights by night.
SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place
or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a
license therefor from the city or borough in which such highway may be situated, he shall pay said city,
town or borough all costs and damages which it shall sustain, or be compelled to reason therefor."
IlAdIV INSPECTION REPORT
Permit # d6a Job f
1 Footingo''
2 Foundation
3 Framing r
4 Wiring
5 Plumbing
6 Heating
7 Lathing
8 C.O.
TO THE BUHDING INSPECTOR
of the APPLICATION FOR
I,VYN OF SOOUM WINDSOR,COS.
PLAN EXAMINATION AND
BUILDING PERMIT
IMPORTANT — Applicant to complete all items in sections: 1, 11, 111, IV, and IX.O
I• ZONING
AT (LOCATION)/ r DISTRICT
LOCATION NO.) STREET)
OF BETWEEN AND
BUI LDING CROSS STREET) CROSS STREET)
LOT
SUBDIVISION LOT BLOCK SIZE
N
II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D o
A. TYPE OF IMPROVEMENT D. PROPOSED USE - For"Wrecking" most recent use
1 New building
4
g Residential Nonresidential
2 Addition(1/residential, enter number 12 One family 18 Amusement, recreational
of new housing units added, if any,13 Two or more family - Enter 19 Church, other religiousinPartD, 13)
number of units- - - - -I,.
3 Alteration (See 2 above)
20 Industrial
14 Transient hotel, motel, 21 Parking garage4 Repair, replacement or dormitory - Enter number
5 Wrecking (If multifamily residential, of units ------- - -! 22 Service station, repair garage
enter number of units in building in 15 Garage 23 Hospital, institutional
Part D, 13)
16 Carport 24 Office, bank, professional
6 Moving (relocation)17 Other - Specify 25 Public utility
7 Foundati n only 26 School, library, other educational
B. OWNERSHIP 27 Stores, merconfile
8 Private (individual, corporation,
28 Tanks, towers
nonpr fit institution, etc.) 29 Other - Specify
9 Public(Federal, State, or
local government)
C. COST Omit cents) Nonresidential - Describe in detail proposed use of buildings,e.g., food
processing plant, machine shop, laundry building at hospital, elementary
10. Cost of improvement•,•............. S school, secondary school, college, parochial school, parking garage for,
department store, rental office building, office building at industrial plant.
To be installed but not included If use of existing building is being changed, enter proposed use.
in the above cost
a. Electrical...................... O•-
b. Plumbing ......................
i
c.Heating, air conditioning.........
d. Other(elevator, etc.)...........
11. TOTAL COST OF IMPROVEMENT E
III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L;
for wrecking, complete only Part J, for all others skip to IV.
E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS
30 Masonry(wall bearing) 40 Public or private company
48• Number of stories................
31 W ad frame 41 Private(septic tank, etc.)
49. Total square feet of floor area,
all floors, based on exterior
32 Structural stool dimensions ....................
33 R inforced concrete H. TYPE OF WATER SUPPLY
34 Other - Specify 42 Public or private company
50. Total land area, sq.ft. ...........
43 Private(well, cistern) K. NUMBER OF OFF-STREET
PARKING SPACES
F. PRINCIPAL TYPE OF HEATING FUEL 1. TYPE OF MECHANICAL
51. Enclosed .......................
35 Gas Will there be central air 52. Outdoors.......................
36 Oil c nditi ning? L. RESIDENTIAL BUILDINGS ONLY
37 Electricity 44 Yes 45 No 53. Number f bedro ms..............
38 C al
39 Oth r- Specify Will there b an elevator?
54. Number f
Full..........
46 Yes 47 0 No bathr ms
Partial.......
IV. IDENTIFICATION — To b compl t d by all applicants
Name ,,
A a
Mailing address/— Number, street, city, and State ZIP code Tel. No.
1. 6Owneror7' /'lr/L /Q Q aSk_ /100/'\ di9
Lessee
2.
Contractor
3.
Architect or
Engineer
The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction.
Signature of applicant` Address Application date
r too,
00 NOT WRITE BELOW THIS LINE
V. PLAN REVIEW RECORD — For office use
Plans Review Required Check Plan Review Date Plans By Date Plans By NotesFeeStartedApproved
BUILDING
PLUMBING
MECHANICAL
ELECTRICAL
OTHER
VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS
Permit or Approva I Check ObDta
t
ed Number By Permit or Approval Check ObtDateafined Number By
BOILER PLUMBING
CURB OR SIDEWALK CUT ROOFING
ELEVATOR SEWER
ELECTRICAL SIGN OR BILLBOARD
FURNACE STREET GRADES
GRADING USE OF PUBLIC AREAS
OIL BURNER WRECKING
OTHER OTHER
VII. VALIDATION
Building 13364Permitnumber
Building Julyissuedu1y Sa 20 19 $3
Building 5.00PermitFee
Approved by-
TITLE
Iq
TOWN OF SOUTH WINDSOR
BUILDING PERMIT
Date July 20 19 8 3
Fee Paid $.5..00 Est. Value $. . .NIA
Permit N° 13364
on the aide of
Overlook Road Street
Street No.140
Owner Horace Minne f ie ld
Applicant Horace Minnef ip ld
CERTIFICATE OF OCCUPANCY ISSUED:
Date
No.
Fee Paid $
CLASSIFICATION
Remove in ground pool
i
BUILDING PERMIT
OFFICE OF
N° 13364
THE BUILDING INSPECTOR
of the
Town of South Windsor, Conn.
South Windsor, Conn. July 2 0 ig 83
i
Horace Minnefield94ioisto (ferttfj, That
is hereby granted permission to Remove in ground pool
at estimated value of $ N1 A
on the side of 140 Overlood Road Street on land
owned by Horace Minnef ie ld
Said Work to be as described in Application
No. 13664 and to conform to specifications and plans filed with said Application, and Building By-
Laws of THE TOWN OF SOUTH WINDSOR.
Issued July 20 ig 83
F
I
Building Inspector.
Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers
during the day and by both barriers and colored lights by night.
SECTION 1343, GENERAL STATUTES OF CONNECTICUT: `When any person shall place
or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a
license therefor from the city or borough in which such highway may be situated, he shall pay said city,
town or borough all costa and damages which it shall sustain, or be compelled to reason therefor."
it
i
i
FOfr OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: j
NO,7P4 5 ) TOWN OF SOUTH WIND36R 'EST.COS :
BLDG. PERMIT NO. AM 1540 SULLIVAN AVENUE FEE 3p.p
SOUTH WINDSOR, CT 06074 FEES:
644-2511 - Ext. 230
0 - $19000 - $10.00
1000 or fraction
LOCATION OF BUILDING u,t le-j Qv e- led thereof - $10.00
G e .,.c 1 1 D 6 v,.t it J-4 d l c Lv b
OWSER ADDRESS TOWN PHONE NO.
HVAC CONTRACTOR ADDRESS TOWN PHONE NO.
TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL_
A/C COMMERCIAL
VENTILATION BUSINESS
INDUSTRIAL
IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC v,,i— WARM AIR
UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE)
TYPE OF FUEL: OIL-GPM GAS IN-PUT /1/6 ELECTRIC KW
WOOD COAL
OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY
LPG TANK - CAPACITY
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.) :
5z q- 4 6'C6
GROSS HEATING CAPACITY (INPUT-BTUH) /yp,60j NET RATING (OUTPUT-BTUH) !°dd duo
IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN (BTUH)
HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.) :
TONNAGE COOLING CAPACITY (BTUH)
IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) :
TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM)
PLAN MUST ACCOMPANY APPLICATION)
The undersigned hereby applies for a permit to perform the following work and is to comply
with all local ordinances and State of Conn. Building Codes in the performance of such work.
FURTHER DESCRIPTION OF WORK:
15L f5 a D- I- F
STATE LICENSE - NAME & TYPE #DATE SIGNA OF APPLICANT
i
A PROVED DATE
BD 4A 11/88
I - B - R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL.A COL.B 1 COL.C COL.D COL.E COL.F COL.G
11 ROOM cr
p H L W H L W H L W H L W H L W Design Water Temp.
2 ROOM DIMENSIONS, FT U BTUH perFo t of
3 LENGTH EXPOSED WALLS, FT. Q Radiation Selected
4 WINDOW AND OUTSIDE DOOR AREA LL
BTUH BTUH BTUH BTUH BTUH
5 WALL CONSTRUCTION ROOM LIN.FT.OF
Table 9, Line 3 x H) TOTALS RADIATION
6 TYPE OF GLASS FROM LINE 12 SELECTED
Bottom of table used for Line 5)
7 CEILING CONSTRUCTION C
Table 9, L x W)
g FLOOR CONSTIli'Ll Nt
Table 9, L x W or Lin Ft) E
9 COLD PARTITION CONSTRUCTION F
Table 9, L x H)G
10 c 1 all(With Openings)
re42Wells(With Openings) D X
3 Walls(With Openings) or Ent Hall f.
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
TOTAL BTUH AT DESIGN TEMP DIFFERENCE
KT2
COL A~COL.B COL.H COL. 1 COL J COL. K COL.L TOTAL BTUH TOTAL
OF BUILDING RADIATION
1 ROOM AT SELECTED
O H L W H L W N L W H L W H L W DESIGN TEMP.'
2 ROOM DIMENSIONS, FT
DIFFERENCE
U
3 LENGTH EXPOSED WALLS, FT Q
4 WINDOW AND OUTSIDE DOOR AREA U.
BTUH BTUH BTUH BTUH BTUH
5 WALL CONSTRUCTION INCREASE BATHROOM
Table 9, Line 3 x H)TOTAL 20%
6 TYPE OF GLASS -
Bottom of table used for Line 5)
7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON
GROUND OR FILL AT
Table 9, L x W) GRADE LEVEL,USE LINEAR
g FLOOR CONSTRUCTIONt — FEET OF EXPOSED EDGE
Table 9, L x W r Lin Ft)
9 COLD PARTITION CONSTRUCTION
Table 9, L x H)
10 1 Wall(With Openings)
0 03
c o 2 Walls(With Openings) G xeJ
3 Walls(With Openings) or Ent Hall l-
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE
This form is available from The Hydr nice Institute,35 Russ Place,Berkeley Heights,N J 07922 FORM 1503
09-12-89
3. 1
SUMMARY REPORT
Prepared For: Prepared By:
HORAC M%NNEF%ELD H J C
140 OVERLOOK RD' KA$DEN FUEL CO
SOUTH W%NDSOR , CT 06074 Job Name: MINNEFIELD
DESIGN CONDITIONS for SOUTH W%NDSOR
OUTDOOR INDOOR
SUMMER WINTER SUMMER WINTER
Dry Bulb 200 10 72 70
Wet Bulb 75 60
Daily Range 20 Daily Swing 3. 0
Latitude 40 Elevation 465
Safety Factor (%) 30
Latent Factor (%) 24
Sensible
Room Heating Heating Cooling Cooling
Name BTUH CFM BTUH CFM
1ST FLOOR 10v()69 141 7,400 374
2ND FLOOR 9, 148 128 59537 280
3ND FLOOR 14,589 204 91274 468
33,806 473 22,211 19122
HEATING DELTA T 65. 0 COOLING DELTA T 18. 0
NOTE: Calculated Airflow is based upon load requirements.
Verify that airflow calculated is compatible with
selected equipment requirements. **
Electric# CS92. APPLICATION FOR BUILDING PERMIT
Plumbing# 140 OVERLOOK ROAD
b, z`HVAC # ro No 26642 Date:
Sprinkler#
FINAL P R Estimated Cost $ J'2 o
Buildin r-r COMPLETE RED BOXED AREAS Permit Fee I O
Enginee in TYPE OR PRINT ONLY Occupancy Fee $ 5
Affidavit SIGN ON REVERSE SIDE
Appr.for CO. M1 Total Fee 2- o0
TO BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT Additional Cost) $
The undersigned hereby applies to do work according to the following specifications:
Job Location y Q o ll e""1 o'er`R Re/ Lot No. Side of Street Zone
Applicant Dona el NOL,Tel.# g 6 0-7,"-Z',3/1i(o
Address / "/(e Antr on' W co rh try CT' Zip BCX 3 P Lic. # S/ 7 -u 7
Owner/Yo,-4c r /y.in +7 Address /f(O ev rr C,.e`C RW
Architect Address
Sq. Ft. New Area: 1st FI. "B D 2nd FI. 3rd FI. Total New Area
Rooms f Lavatories V Bathrooms / Garages
rPurposeofthispermit: 4'1 2 D A oi• ' Un t ro L 01= t'c Cn. i7 a s-e
Lis S a-C/ 'rS 5.. C ,. o. . y t OA01
City Water C Well Septic System Sewer 2
UseGroulf. Construction Type 51t2 00eArea Base nt I Garage
Approved by Date It a
R*vr.d 6/95
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Budding Inspector of any alteration In the plans or specifications of the Building for which this
permit is asked, and agree that this building is to be located the proper distance from all street lines,side yard lines and required
distances from all other zones and is located in a zone in which this budding and its use is allowed.
Signed l,l 7
I hereby apply for a Certificate of Occupancy for the work described In this application for the permit
Signed K"/ x-
DO NOT WRITE BELOW THIS LINE --
INSPECTION COMMENTS
Inspection / Approval Date By Appl
tCodeDescriptionDueWhomCodeComment
99-26642-B 32,000
B01 FOOTING 12/03/99 DCJ A CONTR. TO RESECURE METER BOX (REMOVED FROM
WALL)
E01 SERVICE 12/22/99 JFF A NOTIFIED NU
B03 FRAMING (ROUGH) 01/04/00 DCJ A
E03 ROUGH 01/04/00 DCJ A REPLACE PLASTIC DUCT FROM BATH FAN WITH METAL
P03 ROUGH 01/04/00 DCJ A WATER LINES LIVE AND AIR TEST ON DRAINAGE
B04 INSULATION 01/05/00 DCJ A
B10 FINAL 02/02/00 JFF D WITH OWNER BEDROOM SMOKES INSULATE PIPES IN
CRAWL SPACE VERIFY FOUNDWATERPROOF CALLED CON
B10 FINAL 02/10/00 DCJ D SMOKE DETECTORS IN AND PIPES WRAPPED IN CRAWL
SPACE,PROOF OF FOUNDATION COATING NEEDED
B02 FOUNDATION 03/22/00 JFF A TEST HOLES DUG
B10 FINAL 03/22/00 JFF A WITH OWNER
B10 FINAL 03/21/00 JRC A CLOSED OUT.
99-16592-E 1,200
10527-P 4,000
Total Est Value 37,200
Date
RTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT#
plication is hereby:TOWN OF SOUTH WINDSOR
BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230 WL(,1f
Building Inspector
Application must be printed or typed
Location of Job:
EE SCHEDULE 01"z",4 '00For1,000=$13.00 Street No. Street Lot No.
Over$1,000=
13.00 per$1,000
nyy fraction thereof Tenant Designation Apt.No.
APPLICANT IU L Lt%C ZR-cL 10,4L
APPLICANT ADDRESS Ag t/ S
APPLICANT PHONE#
000 S OWNER Ad MCC=c%/L%L
4 OWNER ADDRESS
OWNER PHONE tle j--Q
ESTIMATED COST$ I,;2-zqO dam_
IS THIS A CONTRACT COST? R YeS G No
ICJ FEE ENCLOSED$
TYPE OF JOB:
s R CO 0 New Installation
OAlteration/Addition/Repair Revised 8i99
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? YES NO
RESIDENTIAL
BUSINESS CURRENT USE AND OCCUPANCY
ASSEMBLY
MERCANTILE FUTURE USE AND OCCUPANCY
EDUCATIONAL
INSTITUTIONAL ENGINEER'S NAME PHONE
FACTORY
STORAGE ADDRESS
GARAGE
MIXED USE CITY STATE ZIP
Other please specify)
TYPE OF INSTALLATION/WIRING METHOD C GrZ
SIZE OF SERVICE Ida /q SIZE OF MAIN CONDUCTORS_JL
NUMBER OF METERS_ NUMBER OF DISCONNECTS AND RATINGS l lav,lq
NUMBER OF PANELS_ REMOTE DISCONNECT REQUIRED? *YES NO
NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES 1 NUMBER OF OUTLETS
NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS ----
NUMBER OF A/C CIRCUITS
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
W -rl7l,s/ [- L/Yl iSG•c•'Z
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
AD:41121T
CONTRACTORS LICENSE NO. STATE
SIGNATURE OF APPLICANT Gc/ ZE DATE d
l f?,I s J. fiZ-Y942,1-1,-
INSPECTOR ADATE 2Z TIME )gyvL
LOCATION
INSPECTION: CODE: RESULT(D/A) :
BUILDING:
ELECTRICAL:
I -k
PLUMBING:
HVAC:
OTHER:
F
E
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT#
Application is hereby:TOWN OF SOUTH WINDSOR
BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
1 3
644-2511 ext. 2306 Z
DAte nspector
Application must be printed or typed
Location of Job:
FEE SCHEDULE
O 0
0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
r
1
APPLICANT I'Y1 J I
APPLICANT ADDRESS
C7 0
APPLICANT PHONE# 7 O _ 4
OWNER j
C 0* N S-
4 OWNER ADDRESS O C7 R
n" CIE
rk - OWNER PHONE 3 12 " 5
C ESTIMATED COST$0 o,
IS THIS A CONTRACT COST? A;Yes 13 No
FEE ENCLOSED$ 06
TYPE OF JOB:
SO co RNew Installation
0 Alteration/Addition/Repair Revised 8/99
APPLICATION FOR PLUMBING PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? YES NO
INCtESIDENTIAL
BUSINESS CURRENT USE AND OCCUPANCY 14 o mom,
ASSEMBLY
MERCANTILE FUTURE USE AND OCCUPANCY A. VriS1-
EDUCATIONAL
INSTITUTIONAL ENGINEER'S NAME.7.n Z a w° PHONE
FACTORY
STORAGE ADDRESS
GARAGE
MIXED USE CITY STATE ZIP
Other please specify)
TYPE OF INSTALLATION SIZE OF MAIN DRAIN
t 1
NO.OF TOILETS ' STYLE NO.URINALS STYLE
RlDD 0
NO.OF B THTUBS NO.OF SHOWERS NO.OF LAVATORIES j
NO.OF CONDUCTORS SIZE NO.OF STACKS I SIZE Z,-
AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS
NO.OF OTHER FIXTURES KIND
ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW -V YES NO
SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR
SIZE OF DUCTS SEWER OR SEPTIC TANK
SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER YZ-
WATER HEATER: TYPE l S & MANUFACTURER
DESCRIPTION OF WORK
Um 19= cial
c) K k V-, IN-C,21-4 le e X 1 4; 1 1"n al yo U m
l v\ L C.-.
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
J 3 to Gl) n Y)
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE 3
DARMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT#
ation is hereby:TOWN OF SOUTH WINDSOR D .'yBUILDINGDEPARTMENT
PPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230 C2(e y
Building Inspector
Application must be printed or typed
Location of Job:
FEE SCHEDULE C)
L Q o KP TA- ,
0-$1,000=$13.00 Street o. Street Lot No.
Over$1,000
13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT Y) Qin
APPLICANT ADDRESS 3L A-(\.Lo AX
10 060
APPLICANT PHONE# g b 0 - s 7 a - ^0
N OWNER t
OWNER ADDRESS
h s r C d
too, OWNER PHONE 3 d, O a s-<-
0
ESTIMATED COST$
IS THIS A CONTRACT COST? Fl Yes 0 No
FEE ENCLOSED$ 3-
a + TYPE OF JOB:
afletion
Alteration/Addition/Repair Revised 8/99
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF SYSTEM: TYPE OF BUILDING:
HEATING 0 RESIDENTIAL
A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
g rc, 2 0 w
W 0--
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
OIL—GPM OIL TANK LOCATION :INSIDE OUTSIDE CAPACITY
GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DES RIPTION OF WORK 1 ri o Q_o
t1Y\ V\l 0 Y)
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PER RM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
3o 9 ) 0
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE -2-o O
VA
I=B=R CALCULATION SH EET A 502 1C Vt l • Q, D,,
OWNER ' ADDRESS_ O 40V r O O k Ir DATE
TYPE OF BUILDING CONSTRUCTle*4 ?)1 i 3
DESIGN TEMPERATURE DIFFERENCEF. 190
COL. A C L B '
V
CSaL. C COL. D COL. E COL. F
1 Roots
H L H H L W H L I W H I L W
2 ROOM DIMENSIONS. FT. f 0 v 7 L Zc
3 LENGTH EXPOSED WALLS. FT. ROOMBTU" BTUH BTUH BTUH BTUH TOTALS41GROssWALLAREA. So. FT. REQUIRED REQUIRED REQUIRED REQUIRED REQUIRED FROM LINE I I
51 GLASS AREA. SO. FT. Z
61 NET WALL AREA.s . FT. C) ip B71CEILINGAREA. 9Q. FT.•w O I
81 FLOog AREA. s . F'T.1
A ROOM VOLUME FOR 1•
jNFILTRATION
D
CU. FT. OZ - 7
30 TOTAL 13TUM AT 70F TEMP. DIFFERENCE'EI (TOTAL BTUH AT DESIGN TEMP. DIFFERENCE
2 HEAT DISTRIBUTING UNITS
F
G
COL. A COL- G COL. H COL. 1 COL. J COL. K
1 Roots
H
H L W H L W H L W H L W H L W
2 ROOM DIMENSIONS. FT.
3 LENGTH EXPOSED WALLS. FT. BTUH BTUH BTUH BTUH BTUH
41 GROSS WALL AREA. s . FT. REQUIRED REQUIRED REQUIRED REQUIRED REQUIRED J
51 GLASS AREA. SO. FT. I
61 NET WALL AREA. SO. FT. K
71 CEILIN AREA. SO. FT. p81FLOORAREA. SO. PT. 1 L.
9 ROOM VOLUME FOR
fff
TOTAL BTUH
INFILTRATION OF BUILDING AT
DESIGN TEMP.
CU. FT. DIFFERENCE
TOTAL STUN AT 70F TEMP. DIFFERENCE'
I TOTAL STUN AT DESIGN TEMP. DIFFERENCE
2 HEAT DISTRIBUTING UNITS
NCREASE BATHROOM TOTAL 20% tFop CONCRETE FLOOR ON GROUND OR FILL AT GRADE LEVEL. USE LINEAR FEET OF EXPOSED EDGE
i
I
RADIATOR • 260 NORTH ELM ST. • WESTFIELD MASS. 01085 I Fool"I502