Loading...
HomeMy WebLinkAbout140 Nutmeg Road, SouthYv 3 TO THE BUILDING INSPEA C1 O6 5I6 of lw APPLICATION FOR PLAN EXAM INATION ANDOFWBUILDINGPERMIT IMPORTANT — Applicant to complete all ems in sections: 11, III, IV, and IX.O ZONING AT (LOCATION) DISTRICT LOCATION N0.) 1/ ( STREET) Ole BETWEEN AND BUILDING CRO S REET) CROSS STREET) LOT SUBDIVISION i LOT BLOCK SIZE H II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use rn 1 5C New building Residential Nonresidential 2 Addition(If residential, enter number 12 One family 18 Amusement, recreational of new housing units added, i/any,13 1 in Part D, 13)Two or more family — Enter 19 Churelt, other religion number o/units— — — — --jo- 20 Industrial V e 3 Alteration (See 2 above)14 Transient hotel, motel, 21 Parking garage4 Repair, replacement or dormitory — Enter number 22 5 Wrecking (I/multifamily residential,o/units ——————— ——!E:] Service station, repair garage enter number o/units in building in 15 Garage 23 Hospital, institutional Part D, 13) 16 Carport 24 Officq, bank, professional 6 Moving (relocation) 25 Public utility17 Other — Specify7 Foundation only 26 School, library, other educational B. OWNERSHIP 27 Stores, merconfile 28 Tanks, towers8U1Private (individual, corporation, nonprofit institution, etc.) 29 Other — SpeciJy 9 Public (Federal, State, or local government) C. COST Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g., food Processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement................ school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed,enter proposed use. in the above cost a. Electrical....................... b. Plumbing ...................... c.Heating, air conditioning......... d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT $.21 III. SELECTED CHARACTERISTICS OF BUIL ING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 Masonry(wall bearing) 40 Public or private company 48. Number of stories................ 31 Wood frame 41 Private (septic tank, etc.) Total feet n floor area, all fl000rsrs,, bbased on exterior 32 Structural steel dimensions .................... 33 Reinforc d concrete H. TYPE OF WATER SUPPLY 34 Other — Specify 42 Public or private company Total land area, sq.ft. ........... 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES 51. Enclosed ...................... F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 35 M Gas Will there be central air 52. Outdoors....................... 1150 36 IJ Oil conditionings o L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 Z Y 45 No 53. Number of bedrooms.............. 38 Coal 39 Other— Specify Will there be an levator? 54. Number of Full.......... 46 Yes 47 fV No bothr ms Partial....... NOTES and Data — (For department use) IV. IDENTIFICATION - To b compl t d by all applicants Name Mailing addr ss — Number, street, city, and State ZIP cod Tel. No. Owner a, Lessee r K) fAr— le 2. 0 le Contractor fn s. Architect or Engineer Th own r of this building and the undersigned agree to conform to all appli ble laws of is jurisdiction. Signature of appli nt Address Application date F DO NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans R vi w R quired Check Plan Review Date Plans By Date Plans By NotesFeeStartedApproved BUILDING Q. Q.. ` PLUMBING MECHANICAL ELECTRICAL OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS P rmit or A rova I Check Date Number B Permit or Approval I Check Date Number BPPObtainedyPPObtainedY BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building P rmit numb r 100 6 Building Permit issu d Or- 2_4 19 . 77 Bui Iding P rmit F e $ i Q 1 .650.00 Approved by: s TITLE EVIII. Z_jNING PLAN EXAMINERS NOTESZ' DISTRICT USE FRONT YAW SIDE (ARD SIDE YARD REAR YARD NOTES IX. SITE OR PLOT PLAN For Applicant Use 4a 71,t t tit TTTT I 0" Tot 1 4 401:Q7 J,4b.a--{jaytj_L-14' 44, H,,QVI: 04 4,1-it, _rt;4 T P-01 6+1 v Is AR. AT 4 nQIrill, gin too,TIT, 4440= to 4,till To1,11 4',;4 41 4 f J-Ivy 171It T" tow!rV 114T11 11,Wyn tot 011,Alit i 044 itlfi___I Lixn;:: z Iff-1, id jK UK 11 Th TT-4-ITY ;11110_1 "1111100. 1 01,102010" F"pt:It,!!: 1- 41 tth 00 wjj§I r;illo TWO: ntilt4T W+4 qf4 4HUI—, vol-I44TOOKt,T 14 T T I 'r'! 1,11,- -4Mtore — T j.1 ymn 4ti i !I-fKP14- in I K ff-w wn m! ,,.7 1,i W:ANT, H- A Q!QIrliful icy 1; 110111v 04 nW,woW1,-+0i- , - "g-, __-of 00;1;t Ml q! T;1 1 V;1p, —4-f 'WiT A 4 4,+4_f & vt 1:114rut 01hJigJ"t'14'T7 As Potj71:0 t I., IT1p1qI- t w.. Q!0, ft"T47" MA 4QQT4w 41 Atli ph:AT7,VQ th"30 Rif 11-11 r .1-1 r',JJ4'141*14tl 1 -b y--{e rp-t-w ' 44 1 At1-1 Of 1 0:111 T, wn val 1 1 11 W. Im1+14T_L q-1777 :T q or =11101, 11 i7;tiltij%py W-0 04Ap.W, , w 'i W: -titTV - 4,VAIM N4Q., 1 L 1 t&4111Vill T ill0.01= t;: : 1.1 71-f i:t;l44i7:ttilili IN, T1 411 171-t01T=11Zy 10 W E LILT! 1270 INA .to isW. A"k-4.040 m; J, h 0:W A=" W 14K 1;1:TH vvo,,-a 11 Q;, 40:01 ,74 j,Lae -4-4 A 4,11w 4"+1 A' Qt qj:: , 1''41 4q: I,: JQ 1 j'in ;:q I I 041 44 J- 01 On 11", ., _ Al-40 0101 tin, 414 on+ tl 41 T-,41, WIT 14114 1114; t 4- t 1 44 is 1ps tilt ti 4,11TTr 4El 41 Thy tTWE -f#4 Attittf-Wt- -#4#0 1 000:41 441404"Frod 7"T4 4 t ft ft++-ft f ifOWm-4 1 mum44+4 +444 44 11111MIM011 A4 INS IM10t 4 1441t4I , lift X I it#41+f 44+441,1+ ift 1f i1 ,tiltoVf t- # NA f4f 4T 141 Af fififf 44 r r s TOWN OF SOUTH WINDSOR BUILDING PERMIT x I Date Oct. 24 1977 . Fee Paid $.l,6 5 0.00 Est. Value $.2.7 5.,000'. ry Permit N°' 10016 t y on the sidg.of z Nutmeg Road yStreet Street No. T Owner Franklin Dist, Inc. Applicant -Anthony J. Rus-Sm 4 CERTIFICATE OF OCCUPANCY ISSUED: Date No. 5041 Fee Paid $3.00 CLASSIFICATION Warehouse & Offices i BU11DING PERMIT N2 1001 fi 0MCE of THE BUILDING INSPECTOR Of the Town of South Windsor, Conn. Oct. 24 77. South Windsor, Conn. 19 That Anthony Russo Co. idurtt, strial warehouse and offices is hereby granted permission to 0 at estimated value of $ Nutmeg Road ;; on the side of Street m hand Franklin Distributors Inc. owned by ride Said Wo r to be as described in Application 10316 No. and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR Oct. 24 77. Iss di Ins dor. Streets and sidewalks, obstructed by ezcavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefoe." INSPECTION REPORT Permit Jpb 1 Footing ' 07 2 Foundation QD3Framing70 4 Wiring ' 5 Plumb;lng %A— x4—vl-x, 6 Heating 7 Lathing 8 C.O. i Permit No. IF., 'f l TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. Permit -N n 5041 Certificate of Occupancy THIS I Tw OCERTIF at e ri p^. a • yllatNo, F . T in the Town/j outh Windsor, Connecticut, has been erected and Ampleted in accordance with the Building Code and Zoning Regulations of the Town of South Windsor, and is hereby approved for occupancy. J ing Inspector Owner, Builder Fee Paid "x Date 19 6431 ELECTRICAL APPLICATION Applicalion No. .... 67.38 .... x i on the side of Nutmeg Road. Street f Street No. 140 t Owner Franklin Distributors. Electrician Bloomfield Electric. Co. FILED IN OFFICE OF _ x The Building Inspector t, 4 >Mir. 10.: . 19 78 INSPECTION. 8&No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall bb started= until the plumbing and heating pipes, and the fire r= ; stops (if of wood) are installed, without a special permit from the office of the Building Inspector. P f I l V APPLICATION FOR PERMIT TO DO ELECTRICAI. WORD. UV1 No. 6738. Permit No. 6431 TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. hereby make application to perform Electr cal Work according to detailed description below. All provisions of the Rules for Electrical Installation, Section 48, Building By-Laws, shall be complied with whether specified herein or not. f' South Windsor, Conn., 19Av Sign here Address Locati on a '/ Side of .. Nature of Building r Alt 1 How many stories New or old Building G How many families Kind of Installation c ..How many Stores .. .. ... rs 2/,QUi7r SOwner .1.' ... .. . . Address . .... Architect 1``2/v. y AddressC 17 Builder Address 'C `!V'... G -^! r Electrician d61:2AC41-0..460- ( G 7 CAddress t f4VAE 7 Size of Main Wire ..:./.,s.......I°s oy No. of Light Loops . No. of Heat Loops . No. of Power Loops ................. ................. No. of Light Outlets No. of Heat Outlets . No. of Power Outlets . No. of Light Circuits No. of Heat Circuits No. of Power Circuits No. of Sockets .. No. of Heat Receptacles No. of Motors . No. of Panels Size of Heat Circuit No. of Power Receptacles No. of Switches Total Wattage Size of Power Circuit . Total Horsepower No. of Straight Electric Fixtures No. of Combination Fixtures No. of Receptacles .. .. No. of Cord Drops . Remarks: For other kind of Installation ....... . . Estimated Cost . . 5169 II i I PLUMBING APPLICATION Appliotim Na. 5956 on the......_...... side of y Nutmeg Road Sweet Street f4o. ..._140 Corner .... Franklin Distributors I plumber _ Frank L. Macca i Filed is Office of The Bwl&g April 14 19 78 n aemt,-=nar. No person shall 000savct, add to or ahm eery portion of the drainage system of way huil&og except to repair 66) until a Permit is Scanted by the Building Ingmctor. Application No. ............5.9 5.6.............. permit N2-1...6....9................... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. hereby make application to perform plumbing according to detailed description bel w. All provisions of the Rules for Sanitation, By-Laws, Sections 33 to 47 inclusive, shall be complied with whether specified herein or not. 7 e South Windsor:llot_ 19 .... ..... Sign herez__-_4........................... Address A e I 4. .T".gV ................ ... Location/e(.e...Ial side of ..................................................................................................... Street Nature of Building 11f.!q 7LK..........How many stories .. ......z........................................................................... n Address ...... ............................................................................................................Owner A).g Architect ................................................................................................................ Address ........................................................................................................................ Builder 7'a&/. ............ I............................................. Address ........ Plumber 4......A)..I...Address S)................Z- DRAINAGE CESSPOOLS, How many ... .... Where located ..................................................................................................... Are they water tight .......................................................................... Of what materials are they built ..................................................... Sizeof pipe from house to cesspool . .... .................. .................... Kind of pipe ................. ..................................................................................... MAINDRAIN IN CELLAR, Material ............................ .. Diameter ................................................................................................................. Aboveor below cellar bottom ................... ....................................... ... ........ ......................................................................................................................... SOILPIPES, Material Diameter ................................................................................................................ WASTEPIPES, Material ........ a Diameter.C . TRAPS,Type proposed to use is ... ................. . . .. .. . ........ ............................................................................................................................ RAINWATER LEADERS, where do they run to x/1- 1 ......... ... ..................................................................................................................... REFRIGERATOR WASTES, where do they run to 1.zi-i............................................................................... .........................I..... TANKOVERFLOWS, where do they run to - FIXTURES WATER CLOSETS, How many . ...............2............ ......... Where located . . . .. ................................................................................ Distance from trap to vertical soil pipe ....... ............................. Pattern WASH TRAYS, How many ......................./............................. Where located - - --'_ I.../ SINKS, How many .......................................................................................... Where located .. .. ....................................................................................... BUTLER'S SINKS, How many ........................................................ Where located,................................................................................................... REFRIGERATORSINKS, How many....................................... Where located ................................................................................................... LAVATORIES,How many .................................................................. Where located .................................................................................................... BATH TUBS,How many.............................61 Where located ..................................................................................................... URINALS, How many ..........................I........./...................I..................... Where located ..................................................................................................... Are water closets and urinals to be local vented - / If not, is there a window in outer wall ofroom where same are to be located ........ Estimated Cost PERMIT # Application For 4968 4767 DEPARTMENT DECISION Co W Heating Permit o 3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS X1 APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR o00 O DATE CHIE CTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O 1. LOCATION OF JOB 0 Nutmeg Road NO. STREET v rn LOT NO. FLOOR APT . N iO•i O Franklin Distributors A rt a. OWNER r~ Eastern Park RoadOS. ADDRESS 3 F.aGt Na.rtfnrd_ C^nn, 4.PHONE S. APPLICANT Hartford Automatic Sprinkler Op art a~d o go a. ADDRESS 254 Park Road 9 West Hartford, Conn. 7.PHONIF32-1800 w S. LICENSE No. 205575 a B. EXPIRATION DATE OF LICENSE— 10—1-79 c a 10, 200. 0010. ESTIMATED COST $ eo 11. IS THIS A CONTRACT COST?YES NO 1 s. FEE ENCLOSED = 66. 00 a)13. TYPE OF BUILDING: C R RESIDENTIAL COMMERCIAL cis 3 14. TYPE OF JOB:r aINDUSTRIAL ORIGINAL ALTERATION1INSTALLATIONADDITION REPAIR APPLICATION FOR HEATING PERMIT (C ntinued it m Reverse Side) 11. LOCATION OF JOB f d Nutmeg Road FLOOR APT.NO.NO. STREET 12. TYPE OF INSTALLATION: OIL BURNER ELECTRIC VENTILATION SPRINKLER GAS BURNER STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORK See plans enclosed.15. TO BE DONE: 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS). Roots slzE WINDOWS AREA - SQUARE FEET s.T.U. e.T.U.F DISTRIBUTION INSTALLED AND DOORS VOLUME TOTAL TOTAL NO. < GLASS NET WALL CEILING FLOOR CU.FT. AT 70•F CORRECTED J j RAO. REGISTER ROOM L W N AND W GROSS INFILT.) TEMP. TO . <j f prr TYPE AND SIZE $ O. FT. OR LEADER SIZE WALL F'GtG DIFF. F t O d FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING, OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND te. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OW ER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. 1-14-7R DATE SIGNATURE OF APPLICANT Application For 4970 DEPARTMENT DECISION g tln Permit z o 3 APPLICATION IS HEREBY: DEPARTME OF LICENSES AUND I R NT N APPROVED DISAPPROVED n TOWN OF SOLD ' ET_W w 1-4 Cd o a 2 7 /8 uA n OA 0) DATE CHI; S1. 4 r on APPLICATIONS MUST RE PRINTED OR TVPM 900 1010 MYMNIKM O 1. LOCATION OF JOB 9 O LOT NO. FLOOR API. JM& 0 N i ps o iF&AI l s. OWNER O S. ADDRESS S. APPUCANT A/ S !cr r, O. ADDRESS UCENlfE N0. 4 a4S Y o w s. EXPIRATION DATE OF LICENSE44oio. ESTIMATED CM s B CTXL IB TNO A CONTRACT COM 6/TESEbe Fm FSE s Perm-it 10016 4 v gj ai is. TEE OF BINLDW& an be a 3 14. TYPE F JOB: MISTALLA r x A Ow OIMALTM y Ayip'll APPLICATION FOR HEATING PERMIT (Continu d it Im Rev rw Sid 1 11. LOCATION OF JOB 2' N RE T FLOOR An.NO. 1Z. PE OF INSTALLATION: OIL BURNER ELECTRIC VENTILATION SPRINKLER GAS BURNER STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE A P NO. T BONNET FIRING RATE BOILER OR FURNACE MAKE AND N0. U. OR SQ. FT. NE 2 B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORK 15. TO BE DONE:ti S z 2 s /v/7 S 41- Cc e z to U Is. HEAT LOSS CHEDULE. (TO BE INCLUDED FOR ALL JOBS): RO M SIZE WINDOWS AREA - SQUARE FEET e.T.U. 0.T.U.DISTRIBUTION INSTALLEDANDDOORSVOLUMETOTALTOTAL ROOM NO. GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT F CORRECTED TYPE AND E12! OR LEADERFaRAO. REGISTER L W N AND elSIZEWALL f'GtC INFILT.) DIFF. O SQ. FT.F FREE AREA e TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING, OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND IS. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS P PERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. 3 2 DATE GN RE OF APPLICANT I PERMIT # Application For 49 7;n 4776 DEPARTMENT DECISION Cd M Heating Permit O 3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS aAPPROVED DISAPPROVED TOWN OF SOUTH WINDSOR 00 4ZDA Z7 l CHIEF R / - c n APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BEL W O C 1. LOCATION OF JOB aCd G NO. STREET vdrn LOT NO. FLOOR APT. NO. O ° 79 lV 2. OWNER cc bba 3 S. ADDRESS E 4.PHONE cc Cc Q jamco S. APPLICANT '/ t j lr "' 1 '/Ae e l o s. ADDRESS&I 0 ,4 ec4ll h S 7 ' Pa 6-o3 d7.PHONE J B. UCENSE NO. /a 4Sca o w 9. EXPIRATION DATE OF LICENSE r` 7 tP e O r 10. ESTIMATED COST 11. IS THIS A CONTRACT COSTf L'7 YEgDo P' 12. FEE ENCLOSED : Permit #10016 13. TYPE OF BUILDING N Za0 RESIDENTIAL Q_ - OMMERCIAL cis 3 14. TYPE F JOB:INDUSTRIAL r-+ -i RIGINAL ALTERATIONINSTALLATIONADDITION REPAIR APPLICATION FOR HEATING PERMIT (C ntinued tr m R verse Sid 11. LOCATION OF JOB /7 a r.47. v'''" NO. STREET FLOOR AFT.NO. 12. TYPE OF INSTALLATION: OIL BURNER ELECTRIC VENTILATION SPRINKLER GAS BURNER STACK INCINERATOR MISCELLANEOUS IDENTIFY LOCATION SIZE SIZE SIZE13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED - YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORK S 7`1 QO 15. TO BE DONE: rC7T4f4/ 1s. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): Roots slzE wINDOwS AREA - SQUARE FEET e.T.U. e.T.U.DISTRIBUTION INSTALLED ANO DOORS VOLUME TOTAL TOTAL r1 LL REGISTER ROOM NO. GROSS 6LA3! NET WALL CEILING FLOOR CU.FT. ATTEMP. F CORRECTED Fpt F 4Q TYPE AND SIZE RAO. OR LEADER L W N AND [ WALL Gt IINFILT.) DIFF. F .m w SQ. FT. FREE AREASIZEY' TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING.OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY; NAME ADDRESS SUBCONTRACTORS AND 1s. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. DATE SIGNATURE OF APPLICANT PER111T # Application For 4991 4790 CIS DEPARTMENT DECISION rA eating Permit G APPLICATION IS HEREBY:DEPARTMENT OF LICENSES AND INSPECTIONS4-1N APPROVED DISAPPROVED TOWN OF SOUTH WINDSOII Cd 0000 1DAE CNIE NSPECTO iAPPLICATIONS MUST BE PRINTED OR TYPED:' BE IN WITH MILER'OWE 9E1 C 1. LOCATION OF JOB o cd O. R CIS v 0 4) LOT NO. FLOOR AFT. NO. 0 2. OWNER W,4- ZXI GsS' Cd 0 0 0 a. ADDRESSaQ3 x S. APPLICANT a. ADDRESS ow.0-------wav* IV 7.MONZA"= ew G. LICENSE NO. 9. EXPIRATION DATE OF LICENSE_.r 10. ESTINOED COST w yGV 11. IS THIS A CONTRACT COSTI ES ,' bo Np as 12. FEE ENCLOSED s-- Permit 10016 x Ca 12. TYPE OF BWI.DING C b RESIDEMTIAL MMEROIAL c3 14. TYPE OF JOB: INDUSTRIAL a 161NAL ElALLATIOM ADDITION REPAIR APPLICATION FOR HEATING PERMIT (Condaued from Rev roe 8l&) 11. LOCATION OF JOB v J` S N TIlEtT FLOOR AFT.NO. 12. TYPE OF INSTALLATION: OIL BURNER ELECTRIC U-VENTILATION SPRINKLER GAS BURNER STACK INCINERATOR MISCELLANEOUS IDENTIFY LOCATION SIZE SIZE 13. OFTANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT.GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED - YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORKt lr a<40 m TO BE DONE; Vle 16. HEAT LOSS SCHEDULE. (TO BE INCLU D FOR ALL JOBS): wooM slzE wINDOwi AREA - SQUARE FEET a.T•U. a.T•U.DISTRIBUTION INSTALLED AND DOORi VOLUME TOTAL TOTAL R M L W N N. < GROSS GLASS NET WALL CEILING FLOOR CU. AT 70•F CORRECTED t TYPE AND SIZELEADER j RAG. REGISTER SIZE WALL 'ctW INFILT.) pig' TO F S Q SQ. FT. FREE AREA f d TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING.OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY; NAME ADDRESS SUBCONTRACTORS AND 1e. THEIR TRADES S . OVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE( 7z]: PERTY AND WILL TRICT ACCORDANCE WITH THE BUILDING CODE. E COMPLETELY FILLED IN. 2c DATE T 1 TO THE BURDING INSPECTOR Of the APPLICATION FOR - TOWN OF MUM WHOSM COW PLAN EXAMINATION AND BUILDING PERMIT IMPORTANT - Applicant to complete all i!n in sections: NI, III, IV, and IX.O I• AT (LOCATION) / e ZONING DISTRICT n LOCATION NO.) STREET) OF BETWEEN d AND BUILDING CROSS STREET) CROSS STREET) LOT SUBDIVISION LOT BLOCK SIZE N II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D v A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use T 1 New building Residential Nonresidential 2 Addition(I residential, enter numberf 12 One family 18 Amusement, recreational of new housing units added, if any,13 Two or more family — Enter 19 Church, other religiousinPartD, 13) number of units— — — — -p- 20 Industrial3 Alteration (See 2 above) 14 Transient hotel, mote ,T i h l l 21 Parking garage4 Repair, replacement or dormitory — Enter number 5 Wrecking (If multifamily residential, of units ——————— — —+1 22 Service station, repair garage enter number of units in building in 15 Garage 23 Hospital, institutional Part D, 13) 16 Carport 24 Office, bank, professional6 Moving (relocation) 17 Other — Specify 25 Public utility7 Foundation only 26 El School, library, other educational B. OWNERSHIP 270 Stores, mercantile 8 X Private (individual, corporation, 28 Tanks, towers nonprofit institution, etc.) 29 Other — Specify 9 Public (Federal, State, or local government) C. COST Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., food processing plant, machine shop, laundry building at hospital,elementary 10. Cost of improvement,,,,,,,,,,,,,,,, S school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed enter proposed use. in the above cost a. Electrical...................... r b. Plumbing ...................... Q O c. Heating, air conditioning.........n d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT $ r III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 Masonry(wall bearing) 40 Public or private company 48• Number of stories................ 31 Wood frame 41 Private (septic tank, etc.) 49. Total square feet of floor area, all floors, based on exterior 32 Structural steel dimensions ..................... 33 Reinforced concrete H. TYPE OF WATER SUPPLY 34 Other — Specify 42 Public or private company 50• Total land area, sq. ft. ........... 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 3S Gas Will there be central air 52. Outdoors....................... 36 Oil c nditi ning?L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 Yes 45 No 53. Number f bedro ms.............. 38 Coal 39 Oth r— Specify Will there b an elevator? 54. Number of Full.......... 46 Yes 47 No bathrooms Partial........ NOTES and Data — (For department use) IV. IDENTIFICATION — To b compl t d by all applicants Name Mailing address — Number, street, czty, and States ZIP code Tel. No. Owner r 0 Lessee 2. Contractor 3. Architect or Engineer The owner of this building and t-he undersigned agree to conform to all applicable laws of this jurisdiction. Sign ure of applicant Address Application date 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Re uired Check Plan Review Date Plans By y Date Plans B Notes9FeeStartedApproved BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval Check Date Obtained Number By Permit or Approval Check Ob at ed Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit numb r 10342 Building Permit issued June 16 19 78 Building Permit Fe $18.00 Approved by: TITLE NOTESVill. ZONING PLAN EXAMINERS FRONTDISTRICTUSE SIDE .DSIDE YARD REAR YARD NOTES IX. SITE OR •T PLAN For Applicant NOR ss a i a r I rn:n s:::. as rs .; s :a;:::=ass: =::sonHss • as • s ill. H IiiiiiaaI :i:s:a::;sss:a::==o.=s:=:. :; i l a list ai::=:" aa : ia a s== _:::_;_:::_::::::s a:::::::aa=::::_:i;;::a:sas: ;a= s • i•ira . a! s.. _.. . _. ...a..\ Oman•.• _... • .. .\r...a Willa: a is: . . ._ .. .. s. f•.\=..._ .• a.l i. . a :a e . .:..ai=i a:'!'a ': a'=": ::'s:a";r•.r. a'. \ •: ;_ j • . s a .'s.a . •. • \:13 s 1a (= sl ya i , . is:: =sa;= iiai=iai. aa:u:as.$ a as.•/r s.u• .ii =sai:= s=:iiisi=s i.\a iii i.a. =a s ss:'s:'aBase!::: s: a116:1.1 s sa : 's .::sash:::sss::= =a::;=.:'s::'sE::e's:'s'sa:=='o ';•:sra ss ss:a`sasaS asa: :.s.=sass=cs s's:ss.ss.s....... s.a......... .. ss. s . : !!!!a.ua:a. .r •.. •• ..f. .. Ors. ••/mamas\n• f ..•/..s•s••l...a •iiiss.ss •ii ism''= iiaa:sasarsai:.;.a : ::: \:.S. •: N a: s sf_ . r\ • N2_ rlofts s a n:s__R 1 :s:; a l m••:=:. aa•la till N:a f 5 : r ai . $: : RIna r. \ r/;. : ::/.;. Rmsraiffs 1 •. • ... N r• sawassawmanoHN aa a _ um _ HHemeN no s 0:1asa \ :a::\ : :: Massss :.s::a.:• s women: . . : f .. ss : •:==:= :aNs. .;. e: : a :::= s ::::: : : ii l TOWN OF SOUTH WINDSOR BUILDING: PERNIrT Date June 16 19 7 8 Fee Paid $. .1..8.00 Est, Value $.2,500.06 Permit N° 10342 n on the side of Nutmeg Road %Yr—fiStZeNt Street No. 140 Lr owner Franklin ni s tri htt tors Applicant _?amps S. W_T lby CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Two 4.000 ¢al,aas o l im a tanks BUILDING PERbffr NY 10342 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. .June 16 19 7 8 94is is That Bear Cat Const•rur-t on is hereby granted permission to Install two 4,000 gal. gasoline tanks approved by Fire Marshal at estimated value of $ 500 on the side of 140 Nu"--mp a F c)aci Street on land owned by Frnnklin Disi~r1hu ors Said Work to be as described in Application No. 10642 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issued June 16 1978. Ar Bdidding Ins Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all coats and damages which it shall sustain, or be compelled to reason therefor." I/W/W INSPEJCTION,REPORT Permit #IDL Job 1 Footing 2 Foundation 3 Framing 4 Wiring 5 Plumbing 6 Heating 7 Lathing 8 C.O. OwN 87-0-Wt-2, ap S-aum ?dzt- E` a 1540 SULLIVAN AVENUE - SOUTH WINDSOR. CONN. 06074 r osoe•co AREA CODE 203/644-2511 June 16, 1978 TO WHOM IT MAY CONCERN: This will serve as a Temporary Occupancy Permit, pursuant to Article 120. 5 of the State of Connecticut Basic Building Code, for the Franklin Distributors Building at 140 Nutmeg Road, South Windsor, Connecticut. Very truly yours, f Donald M aug Building Inspector DM/gdc MEMORANDUM June 16, 1978 To: Donald McLaughlin Building Inspector Re: Franklin Distributors The Town has received the $2, 500 Certified Check from Franklin Distributors, as agreed, to assure the repair work to Nutmeg Road. The Engineering is satisfactory at this site for the issuance of a Certificate of Occupancy. 000/ Lester A. Braddock Senior Engineering Inspector LAB:prb FIAAL INSPECTIONS: VA.-gppLICATION FOR BUILDINGBuildingf" Plumbing id PERMIT Oq HVAC f0 d l'I Date: - Sprinkler v d AC 140 NUTMEG ROAD, SOUT Electric 71f ,ru 14C 7e0 3/'st - 6o-XlAf Estimated Cost $ 3$D'c vU Zoning Permit Fee $ 35120 Affidavit 7 1315,46+6 NO. 17990 Occupancy Fee $ Eng. Dept. Fire Dept. COMPLETE RED BOXED AREAS. Total Fee $ 3SD3 Health Dep TYPE OR PRINT ONLY ApprovedforC . _ ''- d SIGN ON REVERSE SIDE. Additional Cost) $ 5-zy TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location O OAT Lot No. Side of Street ZonVe-1 Applicant 5 Tel. #?? Address R , CITY / ST TE -zip © e"/ ic.# Owner ddressJ Architect Address f' Size New Area: Ft. Front Overall-'3 Ft.Deep Overall --Total Area 0 Garages Lavatories No. of Families ZNo. of Stories Construction 5 Bathrooms Rooms 1st 2nd 3rd Size of Lot D'st. from Street Line Dist. from Side Street Line Purpose of this Permit I ' C City Water Well 0 Se tic 0 Sewer Approved by 4,j Date Bo1A 11i88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor" and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree_ that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described In this applicati n for permit. Signed DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# 'G1 Inspections: -Z HVAC Permit# r I L I Inspections: Electrical Permit# f ` ( Inspections: / Sprinkler Permit# 7 Inspections: a Location ofjob AFFIDAVIT Additional Fee . . . State of Connecticut County of Hartford ss. q•/J e Q Owner I .. J" of or building rested under c 4 v 0* a0/ ontractor Permit No. .. issued by the Dep't of Building of the Ibwn of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit was. . 7G S3 G a signed0;7"/ Subscribed and sworn to before me this . .. .. . . . . . . . ... . . . .. .. . .day of . . . . . . . A.D.19 . . . . .. cJ ocJ Estimate Cost:$ &6131 Difference: $ 521 y Nota Public BUILDING INSPECTION DEPARTMENT SOUTH WINDSOR, CONNECTICUT FEE PAID: $3.00 CERTIFICATE OF OCCUPANCY ZONE: DATED 8/17 1990 This is to certify that 140 Nutmea Ready Srnu4:h Alterp-d under permit No._1 7 a g n conforms substantially to the requirements of the building ordinances and the zoning regu,ations of the Town of South Windsor and is hereby approved for occupancy as indicated below. Approved for Occupancy— Addition to existing warehouse a s per plans and PZC Approval Use Group: S 2 Constr. Type: 2C Building Official Notice:If this certificate is lost or destroyed, a duplicate should be obtained immediately from the Building Department. Any change or extension of ail-le herein approved tequbes a new certificate of occupancy. o N ti r V/ V • o C Va 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 R-COS AREA CODE 203 644-2511 May 15, 1990 Anthony J. Russo 164 Winding Lane Avon, Conn. 06001 Dear Mr. Russo; Please be advised that beneficial occupancy is hereby granted for the Warehouse Addition at 140 Nutmeg Road South (Franklin Distributors) , erected under Building Permit #18274, as provided by Connecticut General Statute 29-252-119 .5. The permanent Certificate of Occupancy will be issued upon submission and approval of an "as-built" site plan, and receipt of an affidavit of final cost. This occupancy is granted for a period of sixty days, and will expire July 15, 1990. Please be advised that any changes in the building which constitutes a violation of the conditions of the permit will result in revocation of this approval. Sincerely, John R. Collins, Chief Building Official cc: Marcia Banach, Director of Planning Jerry Iazetta, Town Engineer r(JG = /T o AJV7( NE6- eCl Henry Souther Laboratories, Inc. 24 TOBEY ROAD, BLOOMFIELD, CONN. 06002 TEL. (203) 242-6291 FIELD INSPECTION CLIENT: Anthony J. Russo Company DATE: January 20, 1989 PROJECT: Extension of Franklin Bldg. - East Windsor HSL#:335393 INSPECTOR: Nancy Braul t COMPACTION REPORT Location/ Maximum In-Place Moisture Relative Elevation Dry Density Density Content Compaction FLOOR SUBGRADE 1 . 12' East of West existing wall 51 ' North of Southeast corner of existing wall Elevation: 2' below grade 103.4 103.6 8.9 100 + 2. 33' South of North edge of fill 60' East of West edge of fill Elevation: 8" below grade 103.4 106.7 6.9 100 + 3. 35' West of East edge of fill 45' South of North edge of fill Elevation: l ' below grade 103.4 99.2 7.1 96.0 The above test results are based on proctor test HSL 33356 with a maximum dry density of 103.4 lbs./ft. and an optimum moisture content of 13.2%. Very truly yours, HENRY SOUTHER LABORATORIES, INC. Hugh J. S ully, P.E. Division Manager Building Materials Laboratory & Engineering HJS:sb 2 - Client, 164 Winding Ln. , Avon, CT 06001 Form 33 honk J january 17, 1989 wifi . j I Re: Extension of Franklin Bldg; n Windsor HSL# 33. 356HenrySoutherLaboratoriesInc.. 2+ Tobey Road' cl dent : --- -- - I Bloomfield, CT 06001 ourcet. Herb Holden Pit. (sand xi.m Dons ty 10 A lbs /ft. , ION 276- est• th ASTM. D--Y557-- - - ti 4 /.t-1_h _'_. •t. : i I._.__ a-r}_ I i -T. i ( ': j__ _ rf ..L..(. .-T._ 1 V Y+) 1-.-4 torl_ -a. 7d j_I•.. , :LTi r-f-,-}t1 -t _ t 4-I-- r If riyFr-L -+•-}:_•-__•_.T ..___ _T i___ + +_ 1_T__ EF 44- Y in 1 -- --- •-Ll 1 I l 1 99 1-4 I I LI i I tau _ _.:'•=- -- '--- -:: _ - t t MOISTURE CONTENT (%) Lab #3407 CERTIFICATE Ur ULLUekIN I nr,n L1J1 Applicant Frankl in Dist . Certificate of Occupancy Q Crib /7 990 Address Bldg. Permit No. 7 ?l96 Lot No. Date Submitted 7-31-90 Project 140 Nutmeg Road Reviewed By Date CJ tl r As required in the Zoning Regulations, no certificate-of-occupanc 4 shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan. 2. Finish grading per approved building permit plan. 3. Site work; i.e. trees, shrubs, dumpsters , required parking 4. Utility location a. sanitary sewer b. foundation drain c. electrical & telephone d. water e. other 5 . Appropriate certification s`p K4 r''`l 6 . Bonding Sewer Permit No. Pavement Excay. No. COMMENTS: r11V 45 e*Oe4JIV-- 4 XP 6111 lq,-() CERTIFICATE Ur' Uc:UUrkUNk-;I t-nz%-A -u-Lal T)eAki s, G 6vVej Ap i ant Franklin ni st Certificate of Occupancy Add a Bldg. Permit No. Lot o Date Submitted 7-31-90 Pro c 140 Nutmeg Road Reviewed By Date Qb JR, As required in the Zoning Regulations, no certificate-of-occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan. 2. Finish grading per approved building permit plan. G 3. Site work; i.e. trees, shrubs, dumpsters required parking 4. Utility location a. sanitary sewer b. foundation drain c. electrical & telephone d. water e. other c 5. Appropriate certification 6. Bonding I Sewer Permit No. Pavement Excay.. No. COMMENTS: AAC16W447V11— 401 CICHe 6 z q,) i1 :{'W i$} °7f? j..-.R} .•f' PMI.., y _ S* IT.ir. ff :}. -:'.L _!.v.S4'_ 'l..+c 4 yy';fi". • t ^q. t t r z a +'fs Y' 'r d :"1 r. ''. ;_-' - _imP a U'+. +rC w`" 16 '^E •+i t. PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby:TOWN OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext . 230 Application must be printed or typed . D to Building Inspector 1 . LOCATION OF JOB o So N FEE SCHEDULE No . Street 0 — $19000 — 10. 00 Floor Apt . No. Over $1 , 000 — 10.00 per $1 ,000 or 2 . OWNER ,y{ 1.Tv a f fraction thereof 3 . ADDRESS IZ71d 0 1-,rcIr 4"E 4 . A P P L I C A N T S CO.' c Jc ,r- y r 5 . ADDRESS 29 6 . ESTIMATED COST $ 7 . IS THIS A CONTRACT COST Yes No 8 . FEE ENCLOSED $ I - -oijo,&A!7q4 9 . TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10 . TYPE OF JOB : Original Installation V/Alteration Addition Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11. LOCATION OF JOB NO. S RE APT. NO, 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER L7 fn u h JlIZ212 14 . NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16 . NO. OF POWER LOOPS 17 . NO . OF LIGHT OUTLETS 18 . NO. OF HEAT CIRCUITS 19 . NO . OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21 . NO . OF HEAT CIRCUITS 22 . NOo OF POWER CIRCUITS 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO. OF PANELS 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31 . SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES 33 . TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : f Y C'! //Gti _ li,lP I.-._JZ_P-- r--L-L- - ' .C G_2 LICENSE NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: PERMIT NO. 1791?lz DEPARTMENT DECISION APPLI CAT I ON FOR Application is hereby: PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPROVE DISAPPRO D BUILDING INSPECTION DEPT. 644-2511 Ext. 230 Date Bu ng Inspector Application must be printed or typed. 1. LOCATION OF JOB: 1zT.4 FEE SCHEDULE 2. OWNER: 9 S i , t.C7"r3' 0 - $19000 - 10.00 3. ADDRESS: f(40c-i7 Over $1 , 000 - 10.00 A&4cTN" W/A/aSQ/Z-- C( . per $1 ,000 or 4. APPLICANT: "C-fraction thereof 5. ADDRESS: ' kox ljoa S 2 J s 6. EST. COST: 7. IS THIS A CONTRACT COST? '*-/-YES NO 8. FEE ENCLOSED: $ St• y, 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: l9 /Q LkT- n f,&- SO . GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS_ 25. NO. OF OTHER FIXTURES KIND 14 l b l 2 FY iJ /Y 0(-) s6Z- C: 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS bqft_(,,ragl A( 4\ Lnuz(z 0 WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TE11PERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER 0),0( LICENSE NO. DATE SIGNATURE OF APPLICANT PHONE NO. 3 F 1 1 1° a , E list ONLY APPLICATION FOR RVAC PERMIT DATE: $' 9 0 TOWN OF SOUTH W WINDSOR EST.COST: / j . BLDG. PERMIT A10. 1540 SULLIVAN AVENUE FEE 2 S VISORS, CT 06074 FEES: 0 $19000 .. $10.00 4-2111 - Ext. 230 1000 or fraction m thereof - $10.00 LOCATION OF BUILD NC I Cb 'N(x rynite, : SO _Ab bi l-7 0/'l 4 OWNER ADDRE* TOWN ' PHONE N0. PW— HVAC ZONTRACTOR ADDRESS- ' TOWN PHONE N0. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION _ BUSINESS _ INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT_LBS. HIGH PRESSURE LIMIT _LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM_ GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) a HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 'V577 L CAS u.N( r' t r2s t P J p E4 /? t/ a 2 S c 2 9r 'Xt S iLNG— c L4bC (a AJ t ok k STATE LICENSE - NAME & TYPE #DATE SIGNATURE OF APPLICANT APPROVED DATE BD 4A 11/88 I - B a R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by Th Hydronks Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATECOL.A COL.S COL.C COL.D COL.E COL.F COL.G1ROOM O H L W H L W H L I W H L W H L W Design Water Temp.2 ROOM DIMENSIONS,FT. V3LENGTHEXPOSEDWALLS,FT. t STUN per F t of 4 WINDOW AND OUTSIDE DOOR AREA IL Radiation Selected S WALL CONSTRUCTION STUN STUN STUN STUN STUN Table 9, Line 3 x H) ROOM LIN.FT.OF 6 TYPE OF GLASS TOTALS RADIATI N lB atom of table used for Line 51 FROM LINE 12 SELECTED 7 CEILING CONSTRUCTION Table 9, L x W) C B FLOOR CONSTRUCTIONt D Table 9, L x W or Lin. F t) E9COLDPARTITIONCONSTRUCTION Table 9, L x H) F 10 _ C 1 Well(With Openings)O G 2 Wells(With Openings) K H J3Wells(With Openings) or Ent. Hall is t 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K L COL.A — _COLS COL.H COL.1 COL.J COL.K COL.L 1 ROOM TOTAL BTUH TOTAL It OF BUILDING RADIATION O H L W H L W H L W H L W H AT SELECTED L W DESIGNTEMP.2 ROOM DIMENSIONS, FT DIFFERENCEU 3 LENGTH EXPOSED WALLS, FT. 4 WINDOW AND OUTSIDE DOOR AREA LL 5 WALL CONSTRUCTION BTUH STUN BTUH STUN STUN Table 9,LIns 3 x H) INCREASE BATHROOM 5 TYPE OF GLASS TOTAL 20% B ttom f table used for Line 5) 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ONTable9, L x WI GROUND OR FILL AT B FLOOR CONSTRUCTIONt GRADE LEVEL,USE LINEAR Table 9,L x W or Lin Ft.)FEET OF EXPOSED EDGE 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 _c 1 Walt(With Openings)O 2 Walls(With Openings) X L J3Wells(With Openings) or Ent. Hall F, 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form Is available from The Hydronics Institute,35 Russo Place,Berkeley Heights,N.J.07922 FORM 1503 990-01-22 14 : 07 203 528 9539 CLOVER CORP. 001 P03 svors 100 MODEL F PAGE OF rTi OUGHT M111 SUSPENSION POINTS (2) OR F41 OPTIONAL VERTICAL POSITION 3/9-16/911ALE TMREAO ELECTRIC SUPPLY CONNECTION sit NOTC 1 O 1 Ili I 0 y i = WENT sitE 1 1 Or T t ONA1. TOP rAN GUANO A fF-M OPT 1110061 R w•+ S t 11 L = OAS Cft* LOUYtRi Imot SUPP1 t t INra MONI AIONT SIDE REAN NOTES: 1. Use dimension"4"for(2)point suspension and"E"and"F"for(4)point. Factt)ry equipped (2)point suspension,- (4)point is optional. may SERIES 100 MODEL.F DIMENSIONS(ACCURATE WIT IN PL OR MINUS 1/8") L MODEL A B C D F a H '.' J K M N Na. NAY. Pao. 25 30yTi... 13°!,,!, 27T/fg 31716 V'/32 14'/Ie 14,61, t8 4_ NO 21'h 272'/n 50 30'!y, t;!"/ 17'/T 311/1 51t 141/1 14 19 4 RND 10•/5t 1e '1t, ..h..... 75 30% L591 27y+r. 31'/14 b" 14 14 ti 10 bOVAL 101 16 +/ 'h 211h 27t'/U 100 30!- ... _t 7% 30'/ 31/ 3t'/ 14T 14Yn 19 d OVAL 12fY3t 1Q 'h, .../t.. _.' 27"/ 130 40 17yie 381/16 33"/ 4 10' tasT 23' 7 OVAL 11'Th= 24 'h yz 27_ 38zy± 22 145 Aoyn 4n ;t 351 16 4r/i 1g'3ht 1K. 23_ .. 14 24 1 T/ 2t 36: 5 439/ 2813/it_ 36/IG 351 19,_ .., 24 4i 1p+1 t 21, 12'+ 24 'h '/t 27 38 300 4:it' 28' 38" 34'yl 4Tj 19!aht 1b'3'3x ?1"Y, GL t2+' .. 24 '+ 'It 27 3_83h glrL i, 27 CLEARANCE FROM COMBUSTIBLES WARNING: GAS-FIRED APPLIANCES ARE NOT DESIGNED FOR 1, Top and fllim cotlnoctlon•- ti". USE IN HAZARDOUS ATMOSPHERES CONTAINING FLAMMABLE 2. Sides— 18".VAPORS OR COMBUSTIBLE DUST, OR ATMOSPHERES CON- 3. Bottom •— 12" (When supplied wittT optional downturn nozzle, TAINING CHLORINATED OR HALOGENATED HYDROCARBONS. Iltllltllll ciehranCe 18 42".) INSTALLATIONS IN PUBLIC GARAGES OR AIRPLANE HANGARS q, BpC-k clearance. at rvlrtt purposes,the back of the unit mull have 24" ARE NFPAI54 CODESOR CNACCORDANCE46COK$AND ENFOACINO 23.11 clear>tnce. AUTHORITIES. REZNOR 1089 Raznor® Printed In U.S.A MEfiCER•PA.1d137 MANUFACTURER OF GAS.Olt.,ELECTAIC HEATING AND YENTILAIR#G SYSTEMS trwir+I+„WA tom,rmyf ism.l 1530-02-07 12 : 18 203 528 9539 CLOVER CORP. 001 P02 y y.___ w r.rwr....y.r...I .N..y.•.tN 1,rr. yo e•i r r NaDoa/Z 4)c';5/a0 7009 o i Al f+fix ,2 6 45?v ff 40 x re Ado ty B X lo. r,r,M l! 9a r'T x. 61 x 7b AX 1 T Ecru i{Nf F• C` / V 7 'i+ X X .o `lo ter"4 74 •0 0 T4(,o NCtfr ,joss sr 1990-01-2? 14 : 07 203 528 9539 CLOVER CORP. uU1 road x r INDOOR GRAVITY VENTED FORM NO.s-F 1089 SERIES oesaLt:Tr:ss•Faeo100SASFIRED, s FAN TYPE UNIT HEATERS FORMODELFCOMMERCIAL-- INDUSTRIAL USE PAG OF au't• w wM1 Ml.•• f 7 r 1 z i toTZrAfftIlk''I 1, FRONT VIEW REAR VIEW DESCRIPTION STANDARD FSATUfiES The Reznor Series 100,Model F gas-tired unit heaters are designed a Orifices for natural gas for 80%thermal efficiency for rise with either natural or propane gas Aluminized steel heat exchanger lit altos from 25,000 to 400,000 ptuh gas Input Model F units Are designed for coiling Suspension with propeller fans for air delivery. a 115 volt supply voltage I no units feature an aluminized slaw heat exchanger designed with a '115 volt motor with internal overload venturi style tubes and crimped seams.The die-farmed burners are a Fan and limit safer controlsofaluminizedsteelandIncludeflaredportsandAstainlesssteelY burner Insert.Model F units are designed for gravity vonting with a • Energy cut-off(ECO)device vont Outlet that may be positioned either horizontal or vertical. 24 volt control voltage transformer Other standard features on the Model F Series Include a manual a Terminal strip connector for 24-volt field wiringmatch-lit pilot with 100% shut-off and a single-stage, 24-volt gas P vofve, A terminal strip connector facililates field connection to a 0 Single-atAgh combination gas valve remote 24-volt thermostat for automatic operation.tialch unit is pro- a Manual rnatch-lit pilot with 100%shut-off vided with a fan control and required limit safety controls,Including an eiiargy cut-off(EGO)device. Convenient bottom burner accges These units hav boon design-certified by the American Gait Associ- a Lower half safety fan guard ation(AGA)and Approved by the Canadian Gas Association(CGA) a Horizontal directional louversandbeartheAGAorCGAlabel, and are approved for use in Lartrornra, 0 Horizontal/vertical vent outlet NOTE: Model F units lot Callfotnia require the addition of spark pilot 2-point threaded hanger connections Option AN2 or A143. a Baked enamel and aluminized steel finish SERIES 100 MODEL F I ECHNICAL DATA MODEL NUMBER as so 76 100 130 16i 230 t3tuh Input 2s,000 60,000 rS,000 100,000 130,000 186,OQ0 250,000 ,000 t04,000 132,000 1i0, 8Iuh Thermal Output a00o0 40,000 BO:000 80_000 200,000 240,000 320, A AGas cwinectinn—Natural 1/2" 1/?" 1/2" 1/l" 1/2' 1/2'' ! 1/2" 3/4" 9/4"` Size f Standard Horl;ynlulNeillual Vant _ 4"Rd. 4"Re• S"Ova! all Oval 7"Oval A"Oval Oral 1p'Oval 10"Oval 19"Ov t G ntrol Ampts f24-Valli 3:f .33 -.33 •33 23 _.23 23 23 .20 _ 20 ; 1-ull-L ad Amps 0 SV) 0•tf 1.3 1.9 20 40 4,0_ ;4.0 26 40 7_0 ' 280 376 fib ". Normal t, wet Consumption-watts ff0 AS 135 195— ?a0 275 E. 96 1 h uw at 8'mounting Ili. 39' $0, A8' 00' t311' 78'1.w „ _ 1 moo... GFM 300 850 goo 1260 1600 2200 3300 3800_ 032 I100 1182 1426 1 Outlet velocity(fPMI 423 053 11G0- 1360 1/70 1140 1136, 1/30 I/20 1/20 / - 1!6 1/4 1A Motor Morsepowet Motor RPM 16'SO _1660 15 0 1050 4050 1050 0 850 660 10 10 1Y 14 14 is 22 22 Farr Diameter UO J_ w•' 2 79 t!8 97 132 149 204 2211 E Appros,Net Wt.Lbs n -- A run,31tip Wt.LU6.89 M lot 11A 155 172 232 249 k AGA ratln 8 fOr altllu(1r!a to 2000 feet Ab vo 2000 left de-rat b1 orifice Change,4%1 r each 1000 feet AbOvO sea level. CODA ratings f r ititude3 to 2000 teat High altituos units(2001 to 49M test)de-rated by t0'Jr of maximum input.GAq connections for pfopAne era ih"lot all$ilts.Sizes shown are I r gas connections,not line slie,And ore applicable to single-strtge Oss valvsa NOTE: Nat certified for residential 06 Office Use Only Date: No.Est. Cost: .3-L-'s,0(" Bidg, Permit: Q Fee: sd-22L TOWN OF SOUTH WINDSOR SPRINKLER SYSTEM APPLICATION 1540 SULLIVAN AVENUE 644 -2511 EXT. 230 Location of Bldg.: Af qk QrA,&,f 9 uyw dk Street Address Owner: b/S l r`` v uKS N J/i,,• l J rI• sul LY, Name Street Address City Sprinkler Contractor: 11 1F°v1,D C"' r G C-t< <'°4t- Name Street Address ty fypt of Building: Business Commercial Industrial_ Others_ J Classification of Wet Pre Action System: Dry Deluge Occupancy Classification: Light Hazard Ordinary Hazard Extra Hazard 41 Size of Pipe Main: Size of Hose Connection: mhrr of Temp. OF Temp. Temp. Color. Heads Rating OF Class Code l - 2 e Ord. Uncol. Intermed. White High v Blue r Ex.Hi.Red V.Ex.Hi. Green Ultra Hi Orange O .K. DATE—W Insurance Approval Stand Pipe Yes No Main Size Riser Size Nose Size Remarks and Further Details: ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE OWNER OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. License No. Signature of Applicant Date FEE SCHEDULE FEE: $0 --$1000 - $10 . 00 1000 or fraction Thereof -- $10 . 00 Bectric# APPLICATION FOR BUILDINGPlumbing#140 NUTMEG ROAD, SOUTH PERMIT HVAC # Sprinkler# No. 24187 Date:a FINAL APPROV- Building COMPLETE RED BOXED Estimated Cost 6'neering AREAS Permit Fee Affidavit TYPE OR PRINT ONLY Occupancy Fee Appr.for CO. SIGN ON REVERSE SIDE TO BIALDM D&ARTMEW. TOWN OF Total Fee j The undersigned hereb a SH W DSOR.CT Additional Cost) y wlies to do work according to the following specifications: Job Location ^V",-, Q S+r,L f 'U 11 J Applicant .. Zz e, Vl, `LoAo• Side of Street Zone Address "') "vi Tel# Own r CI tf AddressAddr !`gyp V1/ zip lic.# S 4ArchitectAddress Sq.Ft.N w Area: 1st FL 2nd FL 3rd FLRooms Total New AreaLtoriesBathroomsGarPurposeofthispermit: errs r,_ate Mo City Water Well Septic System Sewer pIns. H.O. S.P. Cart. AreaApprovedby_J Dat 1t3 '7 Basement _ Garage the Group Construction Type I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is tYthis roper distance from all street lines,side yard lines,and required distances from all other zones and is located in and its use is allowed. Signed I hereby apply for a Certificate of Owork described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS APPLICATION FOR PERMANENT SIGN PERMIT r Zoning Ap royal: 140 Nutmeg Road, SOUTH Est. Cost: Ref. No. 25001 Permit Fee: $ Final Inspections: Approved.- Building WT to +o Electric # Zonincf'h a j Applicant Name RA Y r7— tJ >TT7 e it S' o% Address b 5-a 4!: y'e_l A i S, 41I%fl d To - Phone Location of Sign f`10 4)uTN1*y JI So Zone Sign Size (square feet) L5 Sign Height 6 # of signs on site: _Free-standing _0 Wall TYPE of SIGN: Wall or[9 Free-standing ® New or Replacement Illuminated? Yes ® No Description of sign materials and lighting: ftl eels° ATTACH DIAGRAM OF SIGN INCLUDING DIMENSIONS have read, unders d and afire abide by the South Windsor Zoning Regulations, Signs. SIGNATURE Date g!R4If r Inspection / Approval Date By Appl Code Description Due Whom Code Comment 98-25001-B 1,800 B10 FINAL 10/04/00 DCJ A CLOSED OUT.