Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
140 Nutmeg Road
1C M £ TOLJN OF SOUTH WINDSOR , CONNECTICUT 1 PLANNING AND ZONING COMA ISSIO;V Pt Vjr APPLICATION FORM Application No . : rV' r Date Received : O •'R Action/Public Hearing by : S --C •9:? Receipt No . : 1 South Windsor PlAning $ Zoning Comrr:ission APPLICANT :Austin J. Stack ADDRESS : 140 Nutmeg Road, So. Windsor, CT 06074 TELEPHONE : 528-9128 OWNER OF RECORD ON LAND RECORDS :Same as Above ADDRESS : COMPLETE LOCATION OF PROPERTY : Located on the East side of Nutmeg Road adjacent to rail spur line approximately 300' North of South ZONE lP Satellite Road NAME , ADDRESS , & TELEPHONE NUMBER OF PERSON TO WHOM INQUIRIES SHOULD BE DIRECTED : Same as Above TELEPHONE : THIS APPLICATION IS FOR : (Check one of the following ) 1 . Zone Change to Public Hearing required ) . 2 . Subdivision . 3 . Open Space Subdivision (Public Hearing required ) . 4 . Resubdivision (Public Hearing required) . S . Special Exception to Article Public Hearing Required ) . g 6 . Site Plan of Development . 7 . Earth Filling [ Section 10 ] and/or Earth Removal [ Section 9 ] Public Hearing Required) . g . General Plan of Development . 9 . Regulation Amendment : Zoning Subdivision 10. Other (explain in detail ) : t1uNc:)u 1i PLANN1NU DEPARTMENT FOR FEE SCHEDULE . THIS APPLICATION MUST BE SIGNED BY THE APPLICA'N'T AND OWNER OF THE PROPERTY AND S MITTED IN TRIPLIC= [vITH af,f, [a'S AND DOC[T tFNTS REO? n 1 IL C111]CLIST . CHECKLIST REQUIRED INFORMATION p SITE PLANS This checklist must be signed by plan preparer (P.E. /L.S . ) declaring that all required information is provided . Items 1-7 are required for all applications ; items 8-11 required where appropriate. Check mark for each item supplies . On each sheet for plans or maps, title block with the following information : a. Name , address and telephone of applicant . b . Name , address and telephone number of Land Surveyor or Professional Engineer . c. Name of Development . d . Date when drawings were made. 2. Key Map: An overall map drawn to a scale of 1 inch equals 200 feet , which can be used as an overlay on Metropolitan District Maps . This map will show the overall design of the Development and surrounding property within 500 feet. a. Data block which gives needed zoning information such as percentage of lot coverage, acreage of tract, number of apartment units, parking requirements , etc. b . Layout of buildings r c. Layout of streets and parking. d. Lines indicating proposed drainage system with direction arrows . e. Lines indicating sanitary sewer system with direction arrows. Names of surrounding property owners . g. Proposed open spaces and recreation areas. h.' 'Driveway cuts on surrounding properties. 3. Architectural Elevations : Plans of the proposed buildings drawn ,to a scale of 1/8" = 1 ' - 0" showing the elevations of all sides of the proposed buildings in sufficient detail to show architectural styling . Architect' s seal on elevations for buildings in excess of 5000 square feet (per CGS Chapter 390) . Page 2 (Site Plans) 4 . Plot Plan: A layout map of the proposed site drawn to @ scale of 1 inch equals 40 feet on either of the following size sheets: ( 1 ) 24" X 36" with a 3/4" ruled margin; (2) 18" X 24" with a 1/2" ruled margin, containing the following data: a. Distance and bearings of all boundary lines and acreage of site. Iron pins required at all property angle points and shown on map. b. Proposed streets and street lines with center line stations , Curve data, and parking spaces . C. Building lines in accordance with zoning regulationb. d. Proposed buildings and other structures, including signs, outside lighting, and dumpsters (on concrete pad and screened) e. Easements, noting grantors , grantees , and purpose. f f . Names of abutting property owners . g. Monuments will be indicated at corners and angles of all streets and at all points of curvature and tangency . In areas accessible to Metropolitan District Commission points , or other coordinated points , the monumented points within proposed site shall be coordinated . These coordinates shall appear in tabular form on the plot plan. The accessibility of these MDC points shall be determined by the Town Engineer. h. All open space or other common or public land uses shall be indicated . i. A-2 certification ; P.E. /L.S . Seal. f S. Topographic Map : A map drawn to a scale of 1 inch to 40 feet on sheets not exceeding 24 inches by 36 inches , including ruled margins shall in addition to the requirements of the plot plans show the following: a. All existing and proposed buildings. . b. Curb lines and pavement width , sidewalks. C. Existing and proposed sanitary sewers . d. Existing and proposed water and gas main systems. e. Present wooded area indicated by foliage lines . Any individual trees to be saved should be shown. Page 3 (Site Plans) f . Existing and proposed contours shall be shown in not less than two-foot intervals , but in cases of r lativ ly 1 vel land , the contours shall b one-foot intervals and spot elevations . g. Regulated wetlands and 100-year floodplain or note that none are present. h. Proposed storm drainage system, showing all catch basins , endwalls , manholes , lengths and sizes of pipes. (Minimum distance between catch basins shall be 300 feet and minimum size of storm drain lines shall be 15 inches . ) J. Connections of all springs into proposed storm drainage system as needed . J . Location and indications of existing brook channels , and 100-year flood limits. k. A-2 Certification ; P .E. /L.S , Seal . 1 6. Landscaping plan . 7 . Drainage calculations - Zero Runoff Increase per attached guidelines . . S. Traffic report . 9. Plans and Profiles : A plan and profile of the proposed streets drawn on plan/profile paper of scales 1 inch to 40 feet horizontally , and 1 inch to 4 feet vertically on sheets not exceeding 24 inches by 36 inches , including ruled margins and containing the following: a. Layout of streets in sections coordinated by stations with the profile . b. Street plan showing roadways and drainage. c. Sight line at driveway & street intersections. d. Profile of roadway showing existing and finished grades . Roadway profile will show all tangent grade and all vertical curve information. . e. Profile will show all catch basins and all drainage lines between catch basins with all invert and top of frame elevations. Drainage lines will be shown and described as to material . f . Where any storm drainage line discharges into an existing brook sufficient profile of this brook will be shown to determine conditions. g. Metropolitan District Commission datum shall be used on all sites accessible to these controls. The Town Engineer shall , based on standard engineering practices , determine the accessibility of these controls. Page 4 (Site Plans) h. Profiles shall show all sanitary sewer lines and manholes , including elevations , sizes, lengths , and slopes of pipes. Top of foundation elevations for building shall be shown. 10. Open Space Site Improvement Plans: For sites which require or include a provision for open spaces, a plan which contains data for site improvement may be required . This map shall be drawn to a scale of 1 inch equals 40 feet. 11 . Sanitary Report: Where individual sanitary sewage disposal systems arepy proposed, the final plans shall include a Sanitary Report certified by a Professional Engineer . The report shall demonstrate the feasibility of the proposed individual systems ; the report should deal with the area as a whole , discussing the following points: a. General nature and development of surrounding area. b. Topography and natural drainage pattern. . c. Subsurface conditions as shown by subsurface investigation , including soil absorption characteristics, ground water level conditions, ledge rock,, and general nature of soil . d . General description of type of development contemplated . e. Detailed description of proposed sanitary sewage disposal facilities , indicating sizes for various ground conditions , materials to be used , and the general layout pattern to be used , etc . f . Special precautions that may be necessary to provide proper functioning of the proposed disposal systems. g. Map of general area with locations of all tests shown on proposed layout . h. Flood heights of any nearby streams, brooks, or rivers . i. Test results and engineering evaluation per Section 4. 13. 50 All information required above is included in this application at the time of submission. PLAN PREPARER Novemb r , 1987 FRANKLIN DISTRIBUTORS 1 .Application for a 13,650 sq ft addition located on the easterly side of Nutmeg Road South, north of South Satellite Road, IP zone. Building coverage is proposed at 31%; 40% allowed. r p6rvious coverage ip proposed at 68$; 555$ allowed. The ap, licant received a, ZBA variance o`rf 6/1/8 9 for this impervious c6veragfiv. 2 . It appears that all other zoning requirements have been met. They currently have 14 Spaces for parking and are not proposing any new parking with his application. WQ Kj-i-A A- yIC n5 6vrCaICOL*Wy` - -56W>n5 e " and a n1Qlaye-e3 3. The applicant received conservation approval on July 10, 1989 with a $5,000 bond recommended and no other unusual conditions. 4 . There is public water and sewer which currently servicing the site (which should be shown on the plans) . WPCA approval is not required. If use (warehousing) of building should ever change and subsequently involve an industrial process waste discharge, a DEP Discharge permit must be obtained. 5 . There is no dumpster shown on the site. Is one required? 6 . Tie lis' no han p' 4-9- th en e J VV- i:t * _I€--se a-ice possibl,e. -to--s-ave any LL 7 . The architecturals for this building indicate that it will be a concrete structure with a metal strip around the top. If this application is approved, the Planning Department requests the following modifications: a) key map to completed in accordance with Sect. 4 .13.2. 1 b) show side and rearback setback lines; parking dimensions; and corner radii c) show existing utilities, and any proposed outside lighting d) show square footages of existing and proposed buildings e) show wood line on plans dT r 4i r show HALLISEY & HERBERT 78 BEAVER ROAD PAUL A HALLISEY, P.E.8 L.S. WETHERSFIELD,CT 06109 KENNETH HERBERT,L.S. TELEPHONE:(203)529-6811 DONALD A. BOOTH,ASSOCIATE, FAX:(203)529-6700 P.E.a L.S. SUN 1'' 1989 sOuth WindsorPIRning & m .DRAINAGE CALCULATIONS Zoning Co miSSlon FOR FRANKLIN DISTRIBUTORS, INC. 140 NUTMEG ROAD SOUTH WINDSOR, CONN. JUNE 79 1989 CzA.1J+cL r,. 1..\ST \3 JT'tt=S C•\acl 4-0, Ro hj> l.1•a! t....G,!.. C C1 r : :L n'z-!:is 'To P'c n C Q /map\T O t.. 1.t""',N., ,s.,,,C'' fir` k°' t' . "" . •`/' '';,,,, 'ti.'(.?C •' C: J A C T. C. ,44."C 4- N1 '.I,..I' ,C E 4 z /R'.., ,.. r `-• ' a tt','Y ..t„,\-i Q A vw C G 3, -. DO S S\w._'Sl L?T. Co.,c. ll'FL`C S ''. FS 0 V-0 2 V ti P Av F O O CZ c e\j -c wz E. P 6.7, n vtTE Al.S d, \FAt_t_ \t'TFNs- fi• ?"*/F'G Ca ">°1L —.czT-oC O a\;TP-W\ULQ""ot- S \ t-\vccI.,T2•:t o r- 1 K. • t=cto opt a..\ E-y t t A T 1_L.. N C =:\.,L1...O t,.) C" 1,»..) r r ' TµtL ` `A..?.ti G o, .R .] "-4`..•• ; \ Y t -.tr. •ti (r tZ. 1 t..x ttr O..'-S\Z-f 1A' V'tT R 'F'l C. `•-: t T ,.1..l..,l t t+ l-''. -.,E. \1...a C;G Cam•aJ I t•a''£ ' .-•t ,, ''.,• •,." _,n!.1+..t , ]... •^, Y fi 14J d. 1A IeA L. C/+"TC\-]. Q A.' \ -a S 1 J Z la.Ga t \' V . C 1J /N b.L..Y' Q Ss V'N'\\?-C,. I (a`. L C 1.]"`\F \t r C A P A C T` V C 'Tt7 E 1.a c E 1 , ~-a.. P\P F c w s a.ti.y t 1., Acc,s.c. w Ta T N'\e_.:[r. ',. t r-• .C1.. T'.•Cam•. i v \'= C31..s [O C t `c c =.a'r a.,P''_L A S A w p r, "t k^ I I Q I 1 N 1..Pr aR u F -T of i. v,)V\1 M t L_•)T ,'t-d iG 1n wa!". r Mf.)C' ts!•'1 u 1 TT"'F'-',i.:t't Q..) r.E t 1 r.lT 1.r D `Ttf w p't't R... Is10N v c a N\`T ls.T U!. l.rT-S a`/ ''-/t,.]';S 1.:..s?'-.ytf S\1=VCR ?J 1 O F r\C a .,.:BOG 1'E"t'Y O :(C.V.Z V Cr,. 1 —.t N t Y.3 Z S- J..N r 1 t5 SYs"E t s . •. 11J F l LT CLsTl o N 3Y ST.l'\ i fir.• r I' v`cam.G P o osQo /d.OL T G ALA 1n E /dl O VFLGPl. r•' /ti"'C.C pnic /'[ C'ti A.S AV- A 1 .n'.t•.\•a/r.r'' 'tom '-'.t.- ,,oi•._-.;i' _`- r`"_CP"r r_:` L t.F AI 44 Flo AT Cos C-2 PTV W` atz N 1°tpC l C p~-7 A H 1 04Z x 5,6 cr a Av- Cr, o 1 , < \d, .'7 3 , 3 Ae 00, ff\ Q C Z,qcl cps V : l.v/`•/ , u ll,r i G- ..,4Tf ...!,-•4 _, c--G Cj\ C. .G 7 l G_ T= (. -07x.ct y . Z - , zoo C'P_,ss F' ,v uS R•,n'Y . AV-! A tSBO© (. 0c.-GAC Al L.1Vit A. Q V r G r C W -- R t l r.JT c, tt c.c* S•-1 , 1V""0-1-Y L O S S e-F s < I oucro ti TLVNCRF 'Ly t = o.11 cFs T AG '+ rG boa v A G5 'fit. ' VS Wit•.+ E rb.S EF0 -L = 4 c" 7-70 C. Ole AT. , z3g+- .Zo r)X . 9 j---- ,\lox S)4- C .a16 C 5 lG = -,I n v'r .,r c- -M A DVS V.lt!1lltire f D 4) SV F A GR- F=.0..)C.F, -, N c."r-1 T tt L.Y ...F'.,'"C.(!_+A't^1 ca.J!''F,.G N Cp G, l 1 6 x avt-*'/t._. v Na F --o '_.s-c-t,Y -..-r o'T"c I t Cl , ;_j . -- r*, i ,1 313 7 2.AoC. G c 09 CS F S4. 1 r l I . u Cis v/> F'.o., `Tr. "?''' S,!"- +.--T,4 T o t..i y sZ-F.u- Zq GR,S PE v IG`1 tAA CZ AL. AZT_A ,Q S C.o`7 C S# Y.. C U 2 r.*.r•.. . -^ - r, r... ; T,d v kr 17 i4t E i4 i / `` 4.1.V i N "IrD Q. .w-`t... '-,i ,./t,..`/S t S -- ,-!r Ra PG tC CC•s l`t.e. t 1. sA4•S I5 SYS`T M W`. c'C Vs. Wit- -a 1..^-tr_A'ZG R_ Ca til C F_ AtiVFACTVQq: Q0 sy!c t>A!-A 6 A2 Q\NIS . S S yS-r i[ t'1 1 o a v-ry C1-1-z0) , !A F.Va r,-r V la\Ts v-\.- v s t c. AKE^ Gl;: I 1LN-T./\-v0Ir 3. 00q J0 Lv T--A IF- vpe r .., Vz, Jj vr Cs t 141 /,;,, M .:S Atj S>v t%r-j > /\L L ELF- -SA U Y 1v1,&y. OF' a. At# S1r-vF 4 M Lv 1 I-.I.- M 4C V SE CMlt p OL ts sip C rA 4 z bs- r, 374 o L77 C A r \z y 13 4 ar P_• v`c tv-.c L F AD'Rs w r.a z Iz.• 7 4 Q c, r..a F .v c G r 0,14(a, GG< Vag. 4b VSI... /S. `' t'V C a .'_=:i t.p F u` 0.S Z c'z 0,3 Obi o a - 1:R740/4 11 1 1.'7 ---LZ 4 r L.v No F (= + 1,`l3 1 0 S - 1,S7$ c7 s 7—crr- b, VpL , or FF Fa ,c. a \,8l P> Gpu 84S c- F L,F, 1Z,35Z = 360 t-Y '--,4SG (_S E a F i L:-rTt to r u j ct .1 27Njr i L:N t*.A Nc .,, x x , 3 . C 1 bp x,:S S c 6L c F V0--rn CF' RV.JGFT r-01L Z L,T- or \NF1l=Cr- TdR K I /Z,3SZ.t 168 "r- U G, "47 S C Z 1 tJ F I B--VTtA T01L NF1L-rszb-tioLi S'Z'K-Ia.G = '*7 N7 C CF' arAL CAPAc 17 C. = 189cF ISM ofir_ CV tvk;3l%,..X DO C.$--# 4-It Zt bS 1> QV1LD11.G CG1r A NRD : 3 '+- 5 = i-7 L.F, Co$VIv+T'S bT-q. VOL . of WNoc-- -o. 14 cs ol r,CJ y --Z'11 cr NFILZ-fr- ' .. tz 7- --T.*Tr^qr, _ LT(r.ONTrItrt., C3zM; x3jx, S8x /moox ,s = ' C.r. 1ram&6',:'3Z 5,)C Z,*?,-N Z = '7 G4- c F OTAt, CI-,,Q/4c 1TY " Sro*'7 Gtl ZO -7-71 GIG fLO o 1LT O.11.E C+ `T\' __t.G.-, U r. s Tt. C •' "'^Rl t 4,- i a x 3Z IsB, u S 13 /;.t,'; = 4, i- u a r'_'" ll*-C"t. 11 r e. . c..Y LI C V5C le. s0, e u I-T5 3o vvo \- AlL-swCp E'Ly L,.sr, fire e----rm r To I st rm-e rMa fI l 4 two 04000goiW AO ew Pat.No.4,759,661 r , Canadian Patent Pending j4jILI' I You can look for lower costs, better results and grec ar design flexibility in your next stormwater Infiltration/retention system wh-ri y(-)u specify THE INFILTRATOR.TM Traditional designs for stormwater Include retr 'n basins, stone filled Infiltration trenches, pipe/stone construction ai concrete structures. Each on limits your engineering options. Basins consumes valuable land; potential health hazard; unattractive nuisance; unsightly; extended operating and maintenance costs. Pip and Stone high cost; heavy pipe and construction equipment; labor intensive; metal pipes corrode.INFILTRATOR' Stone Trench S High Capacity Unit stone fills 2/3 of storage volume; poor storage and surge capacity. Concrete Structures high unit cost; requires heavy lifting equipment; concrete corrodes/spalls; limited safe life. J High density molded polymer chamber-impervious to salt, acid, sewage, chemicals and sunlight, meets H-10 or H-20 loading. Simple, quick, foolproof installation, saves time and money, designed to fit easily with any pretreatment and distribution system you want to use. Each unit, offers far greater storage capacity and more infiltrative surface area than found In traditional systems. High shipping density and low unit weight reduces handling costs. I. '' i.raja Z!',X///,4-I'°•u It AL THE INFILTRATORt" is a complete systems approach to stormwater b management that gives tremendous design freedom to meetg the needs of the individual site. INFILTRATOR'rm units can be k used without stone In trenches or beds for simple,shal- low systems requiring no heavy equipment except a backhoe. INFILTRATORS'"" may also be used in various combinations with stone to meet any goal for storage and treatment. 1. ;fit t7; DESIGN EXAMPLES 1 4 INIIIInn1(xr^, fglfgFARr11C GRAVFLOn cm rsl Irn STONE I 151 4•t i trJ ' fiI 1 End Plate Single layer r111ITn11l r nn,F 1 n rt II I ntlrlrr it 11 n Inn I(Mr; GnAVFL cm nUS11FI1 Sin11F 17' SLOPE 1 ;•,./ '. f,;7,j. r , 1 r,. ;ti 11`,t}` ;F — --- FROM BUILDING 6" 1— j STONE L r t T I l y S.,;ti `..k t .-r •1 f1 T -1 i x r i\., STONE r 1 ' 14._ I_ i =` __`^ I n lnm F nnsF Infiltration trench FILIEn FABRIC Double layer No Vehicular Traffic) TOP A SIDES ' Stormwater pretreatment units and STANDARD HIGH CAPACITY distribution manifolds may be con- SPECIFICATIONS: INFILTRATOR INFILTRATOR crete tanks, sumps, large diameter concrete pipes, poured-In-place SIZE 3' x 6.25' x 4'3' x 6.25' x 1.25' concrete structures, plastic pipes, or combinations of thes common Items. WEIGHT 27 lbs. 33 lbs. THE INFILTRATOR'"fits easily with any of these. STORAGE 8.8111'(66 gal.) 14.7 It'(1 1 0 gal.) AM Ilk W w r y r t r r , RkkOEM Relative Cost Comparison INFILTRATORS TO combin low cost,foolproof installation, and design flexibility to saviatimeandmoney. INFILTRATORS T" reduce r' overhead, material, machine and labor costs. n K•Tt'• I'.JL ilk A a, (jAb INFILTRATORS are Impervious to all components of stormwater. They have been structurally tested by a Registered Professional Engineer who is a University Professor of Civil Engineering. INFILTRATORSTare available with an AASHTO rating of H-10 (16,000 Ibs/axle with 12" of com- pact d cover) or H-20 (32,000 Ibs/axle with 18" of compacted cover). r wr A 4ft w ` A A The INFILTRATOR TO is a complete systems approach to on-site septic leach fields that gives the designer tremendous design flexibility to meet the needs of the individual site. INFILTRATORS TO can be used without stone In trenches, beds, mounds, or with pressure dosing for simple, shallow systems requiring no heavy equipment except a backhoe. LIMITED WARRANTY a)Dip struchml Integrlly of oath Infiltrate"unit,when Installed In accordance with manufacturnt's Inslntellnnc N w!wanl(xl toll e)original purr;haser against dofecflve materials and workmanshipforoneyeafromdateofmamifactureShouldadefectoFT+ear within tho wormnly rrlod,prnchasm nil rst Infrrrn InflNrakv Sysiorni.Inr of Ilia defect within flff.r9n(15)days Infiltrator SystemswillsupplyareplacementunitInfiltratorSystnmsIlahllltysfwifraliyoxr1wimIhecostofrnrnnvcsland/ry InStrtllotirnn of lh 11011 b)TFIEWARRANTY INSUBPARAGRAPH(a)IS EXr:LIISNE.THFRE ARE NOOTIIER WARRAtJilfSMllll RFsf{CT I(,)It IE UNIis RJCLUDIrJG 110WAIMAI Jill S Of MERCIIAMAnILRY OR OF FmJESS FORAPMTICULAPPURPOSFTHEWARRANTYDOESNOTFVENDTOINCIDENTAL.CONSEQI1EN11ALSPf CIALORRJDIRECT DANIArAS it if COMPANYSITALL NOT of LVnI.FTOPPENALTIES OR LIQUIDATED DAMAGES,MLMIIGLOSSOFPRODUCTIONANDPROTITS,LAPOR AND MAICRIALS,ONTPI IEAD COSTS ORCellIER LOSSa)REYFTN'E BICURITI D RY01PrLP StTCIt I('AI LV EXCLUDED FROMWARRANTY COVERAGE ME DAMAGE TO RIF UNITS DUE TO ORDINARY WEAR AND IF".ALTERATION,ACCIDENT,MISUS17,APLISE OR rJF(:LE(_T Or THE L1lJll4 Illf IIt111S POND SLIRJECTED TO STRESSES GREATER TLLAN THOSE PRESCRIPED IN 111E INSTALLATION INSTRUCTIONS TIIF PiACFMf NT BY nLMR OF IMtY:OI fR MAIL PIAI S INlO Pl h'i IT S':VITT M OR AI TY('1ll II A f 1III f!r)I CAI JIf t)BY IT IF COMPANY FURTHERMORE,IN NO EVENT SHALL TILE COMPANY BE RESI'ONSIALE FOR ANY LOSS OR DAMAGE TO If IF BUYER.III[UNIT,OR ANY THIRD PARTY RFSU(TING FROM ITS INSTALLATION OR StIlIPMEM BUYER SHALL PE SOLELY RESPONSIBIF FOR EN':URING TIIAT INSTALLATION(4 IIIF SrSTFM IS CO M11 f IfD IN ACCORDAIICF Will At L N m(wi-r LAWS.C(X)FS,RULES AND RFGULATIONS c)NO REPRESENIATNE OF WE COMPANY HAS TtIF ALMfORITY TO CIMNGE THIS WARRANTY IN ANY MANNER WtIATSOPAR.OR TO EXR ND TI ITSWARRANTY NOWMRMRY AMIFS 10 ANY PARTY ODIER TWIN TO THE ORIGINAL BUYER For more information on costs, delivery, or a copy of our Distributed by design pamphlet, call or write: 123 Elm Street, ff Suite 12A Old Saybrook, CT06475 SYSTEMSINC. FAX(203)3886810 FIGURE 1 HYDROLOGIC SOIL PROPERTIES CLASSIFIED BY SOIL TEXTURE* Effective Minimum Water Infiltration Hydrologic Texture Class CapaciL)LA Rate Soil Grouping inch per inch inches per hr Sand 0. 35 8 . 27 A Loamy Sand 0 . 31 2 . 41 A Sandy Loam 0 . 25 1 . 02 B Loam 0 . 19 52 B Silt Loam 0 . 17 27 C Sandy Clay 0 . 14 ` 17 C Loam Clay Loam 0 . 14 09 D Silty Clay 0 . 11 06 D Loam Sands- Clay 0 . 09, 05 D Silt- Clad- 0 . 09 04 D Clay 0 . 08 02 D Source : Raw] s , W. J . , Brakensiek , D . L . , an(I Saxton , K . E . Estimation of soil proprt-ties" , 'runnsactions of the American Society of Agricultural Engineers , Vol . 25 , No . J , pp. 1316-13209 1982 . ce v 1540 SULLIVAN AVENUE SOUTH WINDSOR, CONN. 06074 tiosoit-coN AREA CODE 203/644-2511 June 29, 1989 Austin J. Stack 140 Nutmeg Road South Windsor, CT 06074 Dear Mr. Stack: Re: Application 89-30P, Franklin Distibutors Due to the number of pending applications and the upcoming August recess, the Planning & Zoning Commission is asking all the applicants received on June 27, 1989 to request a 65 day extension on the time to act on their applications. We have enclosed a standard form for your convenience. Please send us this request by July 11, 1989 . We appreciate your cooperation. Very Truly Yours, t'h'x) Raymond F. Hallowell, Jr Chairman of Planning and Zoning Commission FRANKLIN DISTRIBUTOR$ l 140 Nutmeg Road, Post Office Box 616 j South Windsor,Connecticut 06074-0616 203)528-9138 CT Wat 1/800 842-0135 Jul 7, 1989 SOUth WindsoryPlanning & Z"Wing 00mmissio'n Mr. Raymond F. Hallowell , Chairman Planning and Zoning Commission Town of South Windsor 1540 Sullivan Avenue South Windsor, Ct 06074 Dear Mr. Hallowell : Enclosed is the request for a 65-day extension on our application to the Planning and Zoning Commission. If we may, we would very much appreciate it if we could get on the calendar for the July meeting, r , We know all the applicants are asking to get heard, but ours should not take that much time inasmuch as it is an addition to an existing building and not a new project . Also, it is non-controversial and in a com- mercial area not a residential area. Enclosed are some photographs of the building and the area itself. As it shows,, the addition cannot be seen from the street and would improve the looks of the area by having our trucks , that are now parked in the front , parked in the rear. Our bank, Connecticut National Bank, has given us a one (1 ) month extension already until August and would not give us an extension on the mortgage again. Anything that you or your commission can do to help us out woulde be greatly appreciated. If it is at all possible we are asking to get a chance to appear in July. thank; you very much for your consideration to this application. Very truly yours, FRANKLI- ISTRI UTOR IN j , stin J . stack President AJS :fa encl Date• Raymond F. Hallowell, Chairman T' Planning and Zoning Commission Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 AL 7 1989 South Windsor Dear Chairman Hallowell: Planning &eZoning Commission RE: Application #g "301N The applicant, hereby requests a 65 day eXtenslon of the action date with respect to the above referenced application. Very Trul Yours, ION aE,< 710 OleSau ?Vrie 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 f soR•CO AREA CODE 203/644-2511 July 11, 1989 Austin J. Stack 140 Nutmeg Road South Windsor, CT 06074 Dear Mr. Stack: re: Application #89-30P -Addition to an existing commercial building. At the July 10, 1989 meeting, the Inland Wetlands Agency/Conservation Commission approved with modifications Application #89-30P - IWA/CC permit for the construction of an addition to an existing commercial building located on the easterly side of Nutmeg Road and north of South Satellite Road, IP zone as shown on plans prepared by Hallisey Herbert, Civil Engineers & Land Surveyors, 78 Beaver Road, Wethersfield, CT dated May 19, 1989, revised July 7, 1989 . The following modifications must be adhered to for this permit to be valid: 1 . Black and white transparent mylars of sheets # 1 of 1 with the above modifications and this letter reproduced thereon together with two blueprint copies of the entire set of plans, must be submitted to this Commission to be stamped and signed. This must be completed within 65 days of approval prior to any construction activity on the site. 2 . Construction activities shall be subject to the approval of the Town Engineer. 3 . The application shall indemnify and hold harmless the Town of South Windsor against any liability which might result from the proposed operation or use. 4 . We recommend a bond in the amount of $5000 . to be submitted to Planning and Zoning Commission to ensure compliance with the Erosion and Sedimentation Control Measures . 5 . The permit is valid for one year and shall expire on July 10, 1990. 6 . All approvals required must be obtained and submitted prior to any activity on the site. 7 . A contact person shall be identified directly on the plans . 8 . A letter from the Soils Scientist as to how the wetlands were delineated on this site. This is to be an actual verification of the soils found. Very truly yours, John M. Moran, Jr. Chaff an Inland Wetlands Agency/ Conservation Commission JJMJr. /pmm Enclosure cc: Jerry Iazzetta, Town Engineer Marcia Banach, Director of Planning John R. Collins, Chief Building Official Raymond Hallowell, Chairman, Planning & Zoning Hallisey & Herbert, Civil Engineers & Land Surveyors, 78 Beaver Road, Wethersfield, CT, 06109 owN O c s 1540 SULLIVAN AVENUE - SOUTH WINDSOR, CONN. 06074 OR-CO AREA CODE 203/644-2511 F-. July 18, 1989 Mr. Austin J. Stack 140 Nutmeg Road South Windsor, CT 06033 Re: Application #89-30, Site Plan of Development, Franklin Distributors Dear Mr. Stack: Attached is a copy of comments from the Planning and Engineering Departments regarding the above-referenced application. Please make the necessary revisions to the plans and submit 6 complete sets (including architectural elevations, landscaping plans, etc. ) to the Planning Department. If you have any questions regarding the comments or the procedure, please contact me. Very truly yours, Marcia A. Banach Director of Planning cc: Jerry Iazzetta, Town Engineer A , pN $ O C U 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 f oSolt-co` AREA CODE 203/644-2511 July 14, 1989 M E M O R A N D U M TO: Marcia A. Banach, Director of Plann'ng FROM: Jerry C. Iazzetta, Town Engineer RE: Franklin Distributors We have reviewed the drawing dated 5-19-89 for Franklin Distributors and have the following comments: 1 -- N ) X Pl Ma„_-provide,'-_.-- 2 . Live signature required for certification. JCl/jsv FRANKLIN DISTRIBUTORS - PLANNING DEPT REVIEW COMMENTS Key Map must be completed in accordance with Section 4 . 13 . 2 . 1 of the zoning regulations Plot Plan/Topographic Map Dimension parking spaces, corner radii. Side, rear setback lines needed Any outside lighting proposed? Is there a dumpster on site (or needed)? Existing utilities? (Sanitary sewer, water) Is rear of site wooded? Any trees to be preserved? Show square footage of existing, proposed buildings tcw" sf CO2 r0Gwy K. Tyler s Chief of Police r SOR•CO Police Services SOUTH WINDSOR POLICE DEPARTMENT CONSTRUCTION REQUIREMENTS Project Titlegranklin Dist. 89-30-P Date: July 18, 1989 JT;o"I. Developer is responsible for the purchase and installation of all street and traffic signs. Any signs on or intersecting with a State Highway must be cleared through the Department of Trans- portation. All signs must be in place before a c.o. is issued. L_9 2. Developer is responsible for the purchase of all street lighting through Connecticut Light and Power. CUP will install all lighting once they have received payment from the developer and the locations of the lights has been reviewed by the Police Department. All lighting must be in place before a c.o. is issued. 14_3. Developer will submit three (3) 82 x 11 or 82 by 14 maps of the proposed project to the Police Department for the purpose of identifying and locating all signs. Completed maps will be distributed to the developer, Town Planner and the Police Department. Any changes in road design will require new maps. 4. Temporary street signs must be in place as soon as possible and maintained throughout the project. 5. Emergency phone numbers for the duration of the construction must be provided to the Police Department on a company letter- head. If the developer occupies or owns the building/s after construction emergency numbers must be provided to the Police Department. 6. All buildings located on property which abutts a public highway must be numbered. Such number/s (address) shall be visible from the street. All numbering shall comply with Town Ordinance 6-800 thru 6-802. Barns, garages and outbuilding which are located on the same premises as a numbered structure are excluded. 151 Sond Hill Rood • South Windsor, Connecticut 06074 (203) 644-2551 2- CONSTRUCTION SUGGESTIONS 1 . Keep all shrubbery low around doors and windows so as to allow an unrestricted view. L_y 2 . Locate business name, if applicable, on the building . J/3 . Backlight business name and address . Q 4 . Provide lights over all doors . d5 . Provide ample lighting of parking areas . Q 6 . Advise the new owner / purchaser to provide the Police Department with emergency numbers - (Business, Commercial and Industrial property only) . SIGNATURE Sergeant Thomas C. Hart #103 Traffic Services it Approved by: Chief ry K. y er PLANNING DEPARTMENT IN-HOUSE REFERRAL FORD TO: Karl Reichle, Mike Gantick, Mel Stead,'6red Sha , Gary Tyler, Fire Marsha Lanning, Jim Snow, JEAN ZURBRIGEN FROM: Marcia A. Banach, Director of Planning The Planning & Engineering Departments have received plans for the following project:# Zone Acreage Subdivision Site Plan Residential No. of Lots/units Commercial Industrial Location: Du, Project Description: Future Town-owned property involved? Yes No a)new streets existing frontage also) b)new open space/recreation area active passive c)new detention area Planning Department comments Please let me know by - 7/~ if you will have comments on this application so that I can follow up with your d partm nt wh n I do a Planning D partment report. PLANNING D$PARWENT IN-HOUSE REFERRAL FORK TO: Karl Reichle, Mike Gantick, Mel Stead, Fred Shaw, Gary Tyler, Fire Marshall Lanning, Jim Snow, JEAN ZURBRIGEN FROM: Marcia A. Banach, Director of Planning The Planning & Engineering Departments have received plans for the following project:# Zone_.j Acreage Subdivision Site Plan Residential No. of Lots/units Commercial Industrial Location: ;cti Project Description: -c _=tz 1 = i l t • 7 L` Future Town-owned property involved? Yes No a)new streets existing frontage also) b)new open space/recreation area active passive c)new detention area Planning Department comments Please let me know by 7/ if you will have comm nts on this application so that I can follow up with your d p tm nt wh nr a Planning D partment report. U" " O' pco o c a 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 R•co AREA CODE 203/644-2511 27 July 1989 Mr. Austin J. Stack 140 Nutmeg Road South Windsor, CT 06074 Dear Mr. Stack: re: Appl. #89-30P, Franklin Distributors Site Plan Easterly side Nutmeg Road north of South Satellite Rd. The Planning and Zoning Commission is pleased to advise that it voted on July 25, 1989 to approve the above-referenced sit planofdevelopmentinaccordancewithDrawing #1 of 1 dated 6/7/89 rev. 6/15/89) prepared by Hallisey and Herbert, Project No. 385, and with the following modifications: 1 . Prior to commencement of any site work, a meeting must be held with Town Staff. 2. No building permits will be issued until the final mylars have been filed in the Town Clerk's Office. 3 . This application is subject to the conditions of approval of the Inland Wetlands Agency/Conservation Commission, including a bond in the amount of $5,000. 4 .An as-built plan is required prior to issuance of a Certificate of Occupancy per Section 4.13.10 of the ZoningRegulations. 5 . Footing drains are required if the building has a bas ment. 6 .A landscape bond in the amount of $2,000 is required and must be submitted prior to filing of mylars. 7 .All plans used in the field by the developer must bear the stamp and authorized signature of the Town of South Windsor. B. Key map must be completed in accordance with Sect. 4 . 13 . 2. 1 . 9 . Show side and r ar s tbacks, parking dim nsions, and corn r radii. Mr. Austin J. Stack 2- 27 July 1989 10. Show existing utilities and any proposed outside lighting. 11 . Show square footages of existing and proposed buildings . 12. Show breakdown of parking per regulations -- office and warehouse. 13. Show foliage line on plans, or note that no foliage is present. 14. A live signature is required for certification. Black and white transparent mylars of Sheet #1 with the above modifications, together with three blueprint copies of the entire set of plans, must be submitted to this Commission within 30 days to be stamped and signed. The letters of approval of this Commission, as well as the Inland Wetlands Agency/Conservation Commission, must be reproduced on the mylars. After the mylars have been signed by the Commission, they will b returned to you for filing in the office of the Town Clerk. After filing these plans, a copy of the receipt must be submitted to the Planning Department. Very truly yours, PLANNING AND ZONING COMMISSION Raymond F. Hallowell, Jr. Chairman cc: Inland Wetlands Agency/Conservation Commission a*v& M. Banach, Planning Director J. Collins, Chief Building Official J. Iazzetta, Town Engineer F. Shaw, Supt. of Pollution Control E. Belleville, Assessor W. Lanning, Fire Marshal Registrar of Voters Engineer Applicant PZC File 4 af,` y ate Saum ?d&U&OtCV 1540 SULLIVAN AVENUE . SOUTH WINDSOR. CONN. 06074 R•ca w AREA CODE 203/644-2511 TO BE PUBLISHED IN THE JOURNAL INQUIRER SATURDAY, JULY 29, 1989 LEGAL NOTICE TOWN OF SOUTH WINDSOR PLANNING AND ZONING COMMISSION At its July 25, 1989 meeting, the Planning and Zoning Commission voted to take the following action: 1 . Approve, with modifications, Appl. #89-30P, Austin Stack, for a Site Plan of Development for property known as Franklin Distributors on the easterly side of Nutmeg Road north of South Satellite, I Zone. 2. Approve, with modifications, Appl. #89-31P, JMJ Construction, for a Zone Change to MF-A and General Plan of Development for property to be known as Sunset Ridge Condominiums on the southerly side of Scantic Road east of John Fitch Boulevard, RR Zone. 3. Approve, with modifications, Appl. #89-56P, J. E. Shepard Co. , for renewal of a Temporary and Conditional Permit to permit sand and gravel removal from property on the northerly side of Governor's Highway, I Zone. 4 . Deny Appl. #89-42P, Andre L. Charbonneau, for a Zone Change to I for approximately 40,250 sq. ft. of property on the easterly side of Long Hill Road south of Chapel Road, RR Zone. Dated at South Windsor, Connecticut this 26th day of July, 1989 . PLANNING AND ZONING COMMISSION Raymond F. Hallowell, Jr. , Chairman Marshall Montana, Secretary 4 XCM0 from TOWN OF SOUTH WINDSOR TOWN HALL SOUTH WINDSOR.CONN. 06074 I TO Marcia A. Banach DATE Aug. 9, 1989 Director of Planning L SUBJECT: Franklin Distributors FOLD- East side of Nutmeg Road, rDrth of South Satellite Road) There will be a preconstruction meeting for the above mentioned site plan on Thursday, August 17 , 1989 at 10:00 A.M. here at the Town Hall. cc: L. Braddock, F. Shaw, M. Stead, K. Reichle, B. Lanning, J. Collins, J. McCahill By e Vallez Pre-Mylar Filing Checklist Site Plan m) X// Landscape bond ZIWA/CC bond Deeds/easements if required Pre-construction meeting date 11 Plans filed date 7 °Z Other : 11iwe IwMlsie 1 gltwl atg l s1 ses rleMs erne M64104 astr laaa he" end . Put your address in the"RETURN TO"Space on the reverse side. Failure to do this will prevent this card from boing returned to you. delivered ta and this go of deify=. For$WItIonM IM the following services are available.Consult Postmaster for fees and check box es for additional service(s)requested. t. Show to whom delivered,date,and addressee's address. 2. Restricted Deliveryt(Extra ehmSe)t t(Ext%oharje t 3. Article Addressed to: 4. A icle Number Ml-_ )4V s?-/xJ ` 5SRC 7&7.'57- Oq v 3 Type of Service: 9ORC i0iCRistered Insur ed led COD 60 0(10&'Express Mail Always obtain signature of addressee 4, or agent and QATE DELI ERED. 5. Signature—Addresses se's Address(ONL Y if tk\ x reques and fee paid) 6. Si lure—N op x 7. Date 6f Delivery M Is w i a*&am P-625 092 483 LC .Y%T FOR CERTIFIFC, MAIL C!OVEHAC; Fs,4101,; K• ICU g 0751 A S_ n st:'Qy0a r PU l-Mc C IAA OQ F'O—sta.t d, 1 od F r)>!age ertlied F ee tC NriOrTl Gfl AcyRetjrr)Fie(eipr f)att-,and Add i O{Ai. Poe:Ae l7 C Pr,bsmark n ateC E 1989 LL N G owM sE,` C r T-0 01 C' W •C 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 S R•co'` w AREA CODE 203/644-2511 RE: Preconstruction Meeting - Application #89-30P Franklin Distributors August 17, 1989 IN ATTENDANCE Name Company/Address Telephone # Austin J. Stand Franklin Distributors 140 Nutmeg Road 529-1708 Anthony J. Russo Co. 164 Winding Lane Avon, CT 06001 673-3750 Lester Braddock Town of South Windsor 644-2511 John E. McCahill Town of South Windsor 644-2511 Jerry C. Iazzetta Town of South Windsor 644-2511 Michele R. Lipe Town of South Windsor 644-2511 The following is a brief summary of points discussed during the meeting. Erosion & Sedimentation Control 1 . All erosion and sedimentation control measures are to be in place prior to earth moving operations in each area and maintained cleaned out during construction. Call Zoning/Wetlands Enforcement Officer for inspection when measures are in place, prior to commencement of site work 2. All topsoil stockpile areas to be protected (ringed with haybales or equal) . 3. During construction of the road/driveway a crushed stone tracking pad is to be installed and maintained to minimize tracking of dirt/gravel onto Nutmeg Road. Calcium chloride or water is to be used for dust control as required. Public Works 1 . Four complete sets of approved/revised plans have been provided to Town. They will be stamped by Planning Department along with plans developer needs. 2 . The Public Works Department is to be notified forty-eight 48) hours prior to the start of major construction work with inspections and testing per Developers Checklist required for the following: a) after site is staked out b) all drainage work c) Preparation of subgrade, compaction tests as required by the Town. d) Preparation of subbase, six ( 6 ) inch lifts e) Placement of bituminous concrete, 1 1/2 inch layers . 3. Certification of gravel used as subbase will be required by an approved testing company. 4 . No subgrade formation/base in frozen ground/snow. Same for pipe/structure installation. 5. As built plans are to include horizontal and vertical location of all underdrains, footing drains, and sanitary sewers located by a certified land surveyor. 6 . All pipe and structures to be backfilled with free draining material, compacted in maximum one foot lifts with approved compaction equipment. Any pipe or structure work requires inspection prior to backfilling. 7 . Any problems and/or questions regarding construction of this project will be directed to Tony Russo in the field. 8 . All filling to be done in accordance with Department of Transportation specifications . To be compacted in maximum lifts and tested as necessary. 9 . Weekly job meetings will be held as needed, and can be called by the developer or Town. 10 . Forty-eight (48) hours notice needed for Certificate of Occupancy inspection. Two week review period (10 working days) needed for all individual site (lot) plans prior to issuance of building permit (may be longer if application is incomplete) . See General Guidelines for Certificate of Occupancy and Building Permit. 11 . Only approved copies of lot site plans to be used on job site. Any proposed changes are to be presented to Engineering/Planning Department prior to implementation on change sheet. We will attempt to process within 24 hours. 12 . No paving after October 15 without written approval from Director of Public Works. 13 . Hours of operation 7 :00 A.M. - 5:00 P.M. , no work on Sunday. Planning Department: 1 . Mylar must be put on file prior to building permit being issued. W.P.C.A. 1 . W.P.C.A. approval is not required; if use (warehousing) of building should ever be changed and subsequently involve an industrial process water discharge, a DEP permit must be obtained. SNET/NU 1. Contact utilities for coordination of utilities connection. Police Department: 1 . Emergency phone numbers for the duration of the construction must be provided to the Police Department on a company letterhead. If the developer occupies or owns the building/s after construction emergency numbers must be provided to the Police Department. 2. If an alarm is to be installed contact the Police Department. Building Department: 1 . Plan review with Building Official/Fire Marshall required prior to application for building permit. Coordinate with Chief Building Official. Very truly yo rs, Michele R. Lipe Assistant Planner/Analyst MRL/pmm cc: Jerry C. Iazzetta, Town Engineer Lester A. Braddock, Sr. Engr. Inspector Thomas Hart, SWPD Karl Reichle, Public Works Mel Stead, Public Works Minh V. Le, SNET Hal Clisby, CL&P John R. Collins, Chief Building Official Fred Shaw, Superintendent of Pollution Control John E. McCahill, Zoning Enforcement Officer Austin J. Stand Anthony J. Russo TOWN OF SOUTH WINDSOR STAFF SITE CHANGE OCTFORSITE & SUBDIVISION GENERAL: South Windsor Site Name 7 c • It IN;pPing Covni 5 Owner ys 7 r` Phone No.,3W 42r- 2'/3 Contractor. Signature of Owner Date: Signature of Design Engr. Date: CHANGE: (Describe location and nature of change. Include plan/profile of Change) . Gyr rr psi G IF dF R ason for Change: (Why is change required) 7 rr"l ci 7`-a APPROVALS: (As Require ) Dir. Of Planning _ Date: ( Town Engineer Date: 0 Dir. of Public o ks Date: Other: Date: STAFF COMMENTS: cc: Deputy Town Engineer Zoning Enforcement Officer F, Chief Building Official t. c.. y C/ •o C V 1540 SULLIVAN AVENUE - SOUTH WINDSOR, CONN. 06074 soR•c0 AREA CODE 203/644-2511 May 15, 1990 Anthony J. Russo 164 Winding Lane Avon, Conn. 06001 Dear Mr. Russo; Please be advised that beneficial occupancy is hereby granted for the Warehouse Addition at 140 Nutmeg Road South (Franklin Distributors) , erected under Building Permit #18274, as provided by Connecticut General Statute 29-252-119 .5. The permanent Certificate of Occupancy will be issued upon submission and approval of an "as-built" site plan, and receipt of an affidavit of final cost. This occupancy is granted for a period of sixty days, and will expire July 15, 1990. Please be advised that any changes in the building which constitutes a violation of the conditions of the permit will result in revocation of this approval. Sincerely, John R. Collins, Chief Building Official cc: Marcia Banach, Director of Planning Jerry Iazetta, Town Engineer a' 4 4 r d&U1460te 1540 SULLIVAN AVENUE - SOUTH WINDSOR. CONN. 06074 AREA CODE 203/644-2511 September 11, 1990 Planning & Zoning Commission 1540 Sullivan Avenue South Windsor, CT 06074 Dear Madam/Sir: Re: Bonds At the September 10, 1990 meeting of the Inland Wetlands Agency/Conservation Commission, it was voted to release the following bonds: Application #381, Abbe Road Estates in the amount of 10,000.00 . Application #89-33P, Atlas Oil/Oakland Road in the amount of 5, 000.00. Application #89-18P, Capitol Steel in the amount of $5,000.00. Application #87-487, Covensky Industrial Building in the amount of $3,000. 00 Application #294, Evan's Crossing in the amount of $15,000.00. Applicatighi #89-30P, ranklin Distributors in the amount of 5,000.00. ,r. ... Application #89-27P, Gerber Scientific in the amount of 10,000.00. Application #88-45P, KF Brick in the amount of $5,000.00. Application #87-396, Reliable Refuse in the amount of 2,500. 00 . Application #89-37P, Savings Bank of Manchester in the amount of $2.,000.00. Application #373, Terlizzi, Lot 6 & Subdivision in the amount of $10,000 .00. Application #379, Tri-State Laundri s in th amount of 5,000.00. Application #88-107P, Vintage Homes (Foster. - 2 lots) in the amount of $2,000.00 . Application #88-31P, Waldo Brothers in the amount of 5,000.00. Application #89-78P, Gelco Space in the amount of $6,000.00 . Application #405, Knoek Hardware in the amount of $2,000.00. Application #208, Quality Electric in the amount of 2,500 . 00. Press Services in the amount of $2,000.00. Application #89-74P, Boat Works Marine Storage in the amount of $5,000 .00. eFy truly yours, Jr es A. Lombardi, Chairman Inland Wetlands Agency/Conserva ion Commission JAL/pmm cc:Marcia A. Banach, Director of Planning Jerry Iazzetta, Town Engineer Michele Lipe, Ass't Planner/Analyst 4 St,,c C T-a oiAc S d&zd4410te v 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 o ,cpc v AREA CODE 203/644-25U 14 September 1990 Mr. Austin J. Stack 140 Nutmeg Road South Windsor, CT 06074 Dear Mr. Stack: re: Franklin Distributors 5,000 IWA/CC Bond This is to advise that the Planning and Zoning Commission voted on 11 September 1990 to release the IWA/CC Bond. Advance arrangements should be made to pick up the bond to ensure that the necessary contact person(s) will be available. If you have any further questions contact the Planning Department at 644-2511, Ext. 251 . Thank you. Very truly yours, PLANNING & ZONING COMMISSION Marshall Montana Chairman cc: J. Iazzetta, Town Engineer lei. Banach, Director of Planning PZC File n cn q)tst t utois Jnc. 140 Nutmeg Road • P.O. Box 616 South Windsor, CT 06704-0616 Phone (203) 528-9138 - Fax 528-9844 rY A• r`1 4 April 17, 1991 4 Town of South Windsor Planning & Zoning Commission 1540 Sullivan AVenue South Windsor, Ct. 06074 re: Franklin Distributors 5000 IWA/CC Bond Dear Mr. Montana: We would like to be released from the above listed bond. Please contact me so that the property can be inspected and the bond released. Very truly yours, FRANKLIN DISTRIBUTORS, INC. iz Austin J. Stack President AJS:db 140 Nutmeg Road - P.O. Box 616 - South Windsor, CT 06704-0616 Phone (203) 528-9138 - Fax 528-9844 owN sf,q y r Tia W • o U e e w(d 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 f' oSOR,co AREA CODE 203/644-2511 May 8, 1991 Austin J. Stack Franklin Distributors, Inc. 140 Nutmeg Road South Windsor, CT 06074 Dear Mr. Stack: re: Franklin Distributors, Inc. 5,000 Landscaping Bond This is to advise that the Planning and Zoning Commission voted on May 7 , 1991 to release the $5,000 . Landscaping Bond. Advance arrangements should be made to pick up the bond to ensure, that the necessary contact person(s) will 'be available. If you have any further questions contact the Planning Department at 644-2511, Ext. 251 . Thank you. Very truly yours, PLANNING & ZONING COMMISSION Louise Evans Chairman cc: J. Iazzetta, Town Engineer M. Banach, Director of Planning PZC File LCE/pmm BOND A 9 70 THE HARTFORD y T•'U v W(,(O V1 PERFORMANCE BOND Z z S 1,4i'a gyp{'I , C NOW ALL MEN BY THESE PRESENTS: That we Franklin Distributors. Inc. of the Town of South Windsor County of Hartford , nd State of Connecticut as Principal, and Hartford Fire Insurance ompany a corporation duly licensed to conduct a surety business n the State of Connecticut and having its principal office at Hartford , Connecticut as Surety, are jointly and severally ound unto the Town of South Windsor, Connecticut in the sum of FivP Thousand and 00/100ths---------------- Dollars ( $5. 000. 00 or which payment, we jointly and severally bind ourselves, our heirs, xecutors, administrators, successors, and assigns, firmly by these resents. signed, sealed and delivered this 18th day of July 19 $ . HE CONDITION OF THIS OBLIGATION IS SUCH THAT: iHEREAS, the Principal has made application to the South Windsor lanning and Zoning Commission, hereinafter called the Commission, for the approval of a site plan or a plan for the subdivision of certain lands located in the Town of South Windsor, which plans are entitled, Addition to existing building at 140 Nutmeg Road, South Windsor, CT. As shown on plans prepared by Hallisey & Herbert, dated 5/19/89, last revised 7/7/89. WHEREAS, the Commission has approved said plan on condition that the Principal file with the Commission a surety bond in the amount f Five Thousand and 00/100ths----------------------- dollars 5, 000. 00 Said surety bond is posted to insure that certain work and installations required by the Commission in their approval 3ated July 10, 1989 are completed to the standards and Datisfaction of the Town of South Windsor. Said work and installations THE HARTFORD NOW, THEREFORE, if the Principal shall, on or before JULY 18, 19 90 , make and complete to the satisfaction of the Commission, the work and installations herein referred to, this obligation shall be null and void; otherwise, the Principal and Surety shall pay to the Commission, the amount which the Commission pays to complete said work and installations and/or to correct or repair such of said work and installations as fail to meet the standards and specifications of the Town of South Windsor; provided, however, the amount which the Principal and Surety shall be required to pay hereunder shall not, in any event, exceed the penal sum hereof. IN WITNESS WHEREOF, the said Principal and Surety have caused these WF presents to be signed and their seals to be affixed this 18th Pr day of July 19 89 Of Signed, sealed and delivered FRANKLI , bIW--BY: C. in the, presence of: wore L. S. ) date Principal sat! n. / HARTFORD FIRE INSURANCE COMPANY r THE HARTFORD BONA 0022276 PERFORMANCE BOND KNOW ALL MEN BY THESE PRESENTS: That we Franklin Distributors. Inc. of the Town of South Windsor County of Hartford , and State of Connecticut as Principal, and Hartford Fire Insurance _ Company a corporation duly licensed to conduct a surety business in the State of Connecticut and having its principal office at Hartford. Connecticut as Surety, are jointly and severally bound unto the Town of South Windsor, Connecticut in the sum of Two Thousand and OOf100ths---------------- Dollars ( $2. 000. 00 for which payment, we jointly and severally bind ourselves, our heirs, executors, administrators, successors, and assigns, firmly by these presents. Signed, sealed and delivered this 14th day of August 19 $ . THE CONDITION OF THIS OBLIGATION IS SUCH THAT: WHEREAS, the Principal has made application to the South Windsor Planning and Zoning Commission, hereinafter called the Commission, for the approval of a site plan or a plan for the subdivision of certain lands located in the Town of South Windsor, which plans are entitled, Lands ca8in Measures - 140 Nutmeg Rd. , South Windsor, CT. As shown on plans prepared by Hallisey & Herbert, dated 5/19/89, last revised 7/7/89. WHEREAS, the Commission has approved said plan on condition that the Principal file with the Commission a surety bond in the amount of Two Thousand and OOZ100ths----------------------- dollars 2. 000. 00 Said surety bond is posted to insure that certain work and installations required by the Commission in their approval dated July 25. 1989 are completed to the standards and satisfaction of the Town of South Windsor. Said work and installations J THE HARTFORD NOW, THEREFORE, if the Principal shall, on or before August 14, 19 2_Q _ , make and complete to the satisfaction of the Commission, the work and installations herein referred to, this obligation shall be null and void; otherwise, the Principal and Surety shall pay to the Commission, the amount which the Commission pays to complete said work and installations and/or to correct or repair such of said work and installations as fail to meet the standards and specifications of the Town of South Windsor; provided, however, the amount which the Principal and Surety shall be required to pay hereunder shall not, in any event, exceed the penal sum hereof. IN WITNESS WHEREOF, the said Principal and Surety have caused these presents to be signed and their seals to be affixed this 14th day of August 1989 Signed, sealed and delivered Z,IA ST 4BZINC.in t e presence of: BY. L. S. ) PSincipa HARTFORD FIRE INSURANCE C'OMTANY SuLply Company BY: L. S. ) Timothy A. McGurkin Its Attorney-in-Fact duly authorized. DATE: