Loading...
HomeMy WebLinkAbout14 Bancroft Lane (7)s DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WIl TDSOR PERNIIT# Application is hereby:902BUILDINGDEPARTMENT AP 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 g j vc-,, 02 00 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 1 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT te AAJ S 3 APPLICANT ADDRESS no \I S x APPLICANT PHOJE# 37 OWN S OWNER N[t (:2P,'``' oN GTT ON i q 3 OWNER ADDRESS I OWNER PHONE C ESTIMATED COST$ i IS THIS A CONTRACT COST? L-,-Yoeo's No FEE ENCLOSED$ TYPE OF JOB: SOR.Cps New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF S M: TYPE OJF EATING AUIMSIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING y S T AM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. lYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) ET RATING(OUTPUT BTUH) t-.;)Q 000 TYPE OF FUE N-OfL--GPM _OIL TANK LOCATION-U19SIDE OUTSIDE CAPACITY- GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORKS THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3 7n U)- S."OD c7r CONTRACTORS LICENSE NO. TYPE ST TE SIGNATURE OF APPLICANT DATE Iful N a Heat Lose Calculations 00087-hl Column A Column 8 Column C Column D Column E Column F Column G Call, N F P LIV RM DIN RM KIT FAM RM ENTRY GBATH MSTR BATH MB4 N Height A A 8 B 8 B 8 S 8 B 8 B 8 B 8 B a- Length C 0 12.8 T 13 T 18.8 T 18 T 8 T 8 T 14.5 T N Width T E 12 U 12 U 12 U 12 U 12 U 8.5 U 8.5 U CD Length Exposed Wall O N 24.8 H 25 H 30.8 H 30 H 8 H 8 H 23 H Wdw & Dr Area -Glass R 0 26.4 26.4 29 31.7 4 5.2 5.2 O Wall Constr Uo 4.50 1 198 891 200 900 246 1107 240 1080 64 288 64 288 184 828 COD Type of Glass Ug 22.50 1 26.4 594 26.4 594 29 653 31.7 713 4 90 5.2 117 5.2 117 Ceiling Constr Uo 2.34 2 0 0 0 0 0 0 0 0 0 0 6B 159 123 288 Floor Constr Uo 4.23 2 154 651 156 660 226 956 216 914 96 406 0 0 0 0 Door Opening 5.94 1 0 0 0 0 0 0 0 0 20 119 0 0 One Wall (W/Glass) 1.08 3 0 0 0 0 0 0 0 0 0 0 544 588 0 0 0a Two Walls 1.62 3 1229 1991 1248 2022 1805 2924 1728 2799 768 1244 0 0 986 1597 c 0 Three Walls or Foyer 2.16 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total BTUH 4127 4176 5640 5506 2147 1152 2830 t c 0 U Column I Column J Column K Column L Room Name F P MSTR BR BDRM 2 BDRM 3 BDRM 4 BTUH BTUH BTUH Watts Watt Wat a* Height A A 8 B 8 B 8 B 8 B Col. Actual Lgth Used Actual Lgth Us' ep Length C G 13 T 12.6 T 10.9 T 9 T A 4540 8 4960 1331 6 1-` Qj Width T E 17.9 U 13 U 10.8 U 13 U B 4594 8 4960 1347 6 1` c o A Length Exposed Wail 0 N 30.9 H 25.6 H 21.7 H 22 H C 6204 11 6820 1819 6 2( N 11dw & Dr Glass Area R 0 20.6 20.6 20.6 1.0.3 D 6057 10 6200 1776 8 2(O Mall Constr Uo 4.50 1 247 1112 205 923 174 783 176 792 E 2362 4 2480 693 3 N Type Of Glass Ug 22.50 1 20.6 464 20.6 464 20.6 464 10.3 232 F 1267 3 1860 372 2 It Ceiling Constr Uo 2.34 2 233 545 164 384 118 276 117 274 G 3113 6 3720 913 4 1 Floor Constr Uo 4.23 2 0 0 0 0 0 0 0 0 H 464 1 620 136 1 O Door Opening 5.94 1 0 0 0 0 0 I 5651 10 6200 1657 7 1 p One Wall (W/Glass) 1.08 3 0 0 0 0 0 0 936 1011 J 4282 7 4340 1256 6 1'. Two Walls 1.62 3 1862 3016 133.0 2122 942 1526 0 0 K 3354 6 3720 98e4 4 1 ttt--- Three Walls or Foyer 2.16 3 0 0 0 0 0 0 0 0 L 2540 5 31.00 745 3 L Total BTUH 5137 3893 3049 2309 TL BTU 44428 79 48980 13029 58 14 E i r M N7 00087-hl O` a Z1.A Column B Colunui C Column D e/15/02 DIN RM Column E Column F Column 0KIT' FAM RM ENTRY Column H CU B g g 8 8 GBATH MSTR BATH HBATH8B No T 13 T 18.8 T 18 T 8 B 8 8 8 B 8 H U 12 U 12 U 12 U 8 T 8 T I4.5 T 2.5 T N H 25 H 30.8 H 30 H 188 U 8. 8 U 8.5 U 7 U i 26.4 29 31.7 H 8 H 23 H 0 H 891 200 900 246 1107 4 5.2 5.2 02401080D594642886428818482826.4 594 29 653 31.7 71'3 0 0 ool 0 p 0 0 0 0 0 4 90 5.Z 117 5.Z 117 0 00068159123288p651156660226956216914964060 0 0 0 0 0 0 18 7600Q0201190100000Q0020119 v 1 1991 1248 2022 1805 2924 17a8 2799 768 1Z44 544 588 0 00000d00000 0 0 986 1597 140 227ao4127417656405506 0 0 Q 0 0 0 0 0 0 2147 1152 2830 422 c I L 1 Column J Column K Column L a BDRM 2 BDRM 3 UBDRM4BTUHBTUHBTUHWattsWattWatts88B8B8 $ oT12.6 i0. T Cal Actual Lgth Used Actual Lgth Used v9TA4540L C! U 13 U 10.8 U 4594 a 4960 1331 6 1500 U A H 25.6 H 21.7 H 22 H C 6204 8 4960 1347 6 1500 11 6820 1819 8 2000 020.6 20.6 10,3 D 6057 10 6200 1776 8 2000 071112205923174783171S792E236242480593375046420.6 464 20.6 O CL 464 10.3 232 F 1267 3 1860 372 2 SooN545164384Ila276117274G3113006372091341000 N00000H46416201361250 0 0 0 0 I 5651 10 6200 1657 7 1750toM0000936lollJ4282301613102122942 7 3720 1256 6 1500 M152600K3354 CV) 0 0 0 0 6 37a0 984 4 1000000L2540531007453750 ro L r' 137 3 893 3049 2309 TL BTU 44428 79 48980 13029 58 14500 tUEi ro i MAR- 13-10 07 :52 PM RELIABLE PLUMBING 360 653 7637 P. 01 Reliable Plumbing& Pump Service, LLC 15 Ridge Road Granby, CT 06035 860) 653-7637 Boiler Sizing for Lot 38 Bancroft Lane, South Windsor, CT House contains 80 ft of hydronic baseboard radiation with 1 Weil McLain Plus 40 indirect water heater. 80 tZ. radiation @ 560 BTU's per feet is 44,800.00 BTU's Indirect set for priority is 25,000 BTU's Total BTU's for whole house is 6900 Weil McLain P WGO 3 is 120,000 BTU's P 1 lic # 278243 S7 lic # 387920