Loading...
HomeMy WebLinkAbout14 Bancroft Lane (6)7, DEPARTMENT DECISION C PBPMT Application is hereby: AiA _ DEPARTMENT APPROVED zoto!> ate Building Inspector Old'P 47W ti+ of FEE SCHEDULE 0-$1,000=$13.00 Street Street Lot Over$1 000= 13.00 per$1,000 or any fraction thereof Tenant, Apt.No. 04`_tn, APPLI tocr APPLJ r c Wi4WZ Cr a(,Cr7!t yam' S.M. S! pa rt- C ES i rJ IS TFII cs Q No z t gym`g=- 1 CJ FEE 7, TYPE SOR.Cp11 v U Y _ P F " ` APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: HEATING KRESIDENTIAL AA/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE 71!r OF DIFFERENCE 010 OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) j4KE-e 9iga <nWoO C414 Ohs . 7400 Iva# 6foLtC44 Sr OIW +10- ffvWDa-X. rWC 0 140It TONNAGE 3 COOLING CAPACITY(BTUH)_CAM VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK_ IA(571jc l rld lJ d l " C&"rAm- 01;f' G"1 n®1 tlAf L Lj THE tJNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. v 34/1$ 9-1 Cr CONTRACTORS LICENSE NO. TYPE STATE DATE p Z 7 d 3SIGNATUREOFAPPLICANT Right-A Worksheet Job: 38 Bancroft Lane South W11 Entire Hous Date: F bruary 21,2W3 o By: DJS Ka d n Fuel Company 340 Tolland Street,East Hartford,CT 06108 Phone:860-289-5431 Fax 860-289-2133 Email:dansymolon@aol.com 1 Room name Entire House Room1 2 Exposed wall 264.0 ft 132.0 ft 3 Ceiling height 8.0 ft d 8.0 ft heat/cool 4 Room dimensions 40.0 x 26.0 ft 5 Room area 2080.0 ft' 1040.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area (ft-) Load number Btuh/ft2-'F) Btuh/ft2) or perimeter (ft)Btuh) or perimeter (ft)Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 5.82 1.75 640 511 2976 895 320 251 1482 440 L::oG 1 D-c2ow 0.570 n 36.48 18.25 108 0 3940 1971 48 0 1751 876 11 DO 0.390 n 24.96 9.46 21 21 524 199 21 21 524 199 W 12C-Osw 0.091 a 5.82 1.75 416 392 2283 687 208 196 1142 343 11 L--G 1 D-c2ow 0.570 a 36.48 60.15 24 0 876 1443 12 0 438 722 VJ 12C-Osw 0.091 s 5.82 1.75 640 562 3273 984 320 266 1549 466 G 1 D-c2ow 0.570 s 36.48 31.61 78 0 2845 2466 54 0 1970 1707 W 12C-Osw 0.091 w 5.82 1.75 416 383 2231 671 208 187 1089 328 Ejo1 D-c2ow 0.570 w 36.48 60.15 12 0 438 722 0 0 0 0 II DO 0.390 w 24.96 9.46 21 21 524 199 21 21 524 199 C 16B-30ad 0.032 - 2.05 1.53 2080 2080 4260 3178 1040 1040 2130 1589 F 19C-19cscp 0.049 - 1.09 0.22 2080 264 2261 466 1040 132 1131 233 Envelope loss/gain 26431 13881 13709 7101 12 a) Infiltration 22437 2414 11218 1207 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances a@ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48867 16295 24928 8308 15 Duct loads 15% 17% 7311 2822 15% 17% 3729 1439 Total room load 56178 19118 28657 9747 Air required(cfm) 1023 1023 522 522 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. fi w W-IQ"tsoft Right-Suit Resid Mial J8 5.8.15 RSR30950 2003-Feb-21 08:10:31AMC:\My DocumentslWrightsoft HVAC\TemplateU(asden Fuel Project.rrt Calc=MJ8 Orientation-N Page 1