Loading...
HomeMy WebLinkAbout14 Abar Lane (8)PERMIT # Application For 6847 5747 DEPARTMENT DECISION Heating Permit 3 APPLICATION Is HEREBY:DEPARTMENT OF LICENSES AND INSPECTIONSoa N C] APPROVED SAPPROVED TOWN OF SOUTH WINDSOR o Id d DA C EF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOWol o 1. LOCATION OF JOB O 10 LaneCisTREET cdO) y 0 LOT NO. FLOOR APT. NO. 4 O0 O) O r. E 2. OWNERGhL// Cd 1. ba S. ADDRESS n dam/ CS°Ur1 (.(/ !/ 4.PHONE C*3 S. APPLICANT ,Oy7/7 /., •f+a/ 6 /Y G PC s. ADDRESS b / /-2 1 J(/re GVen `/7.PHONEJ.B Pell S. LICENSE NO. L70 7/9a s s. EXPIRATION DATE OF LICENSE c c A 10. ESTIMATED COST o N 11. IS THIS A CONTRACT COST? YES NO60 12. FEE ENCLOSED s Permit 13432 Co 13. TYPE OF BUILDING: NO RESIDENTIAL COMMERCIAL O G 3 14. TYPE OF JOB: INDUSTRIAL ALTERATIORIGINAL INSTALLATION ADDITIONON REPAIR APPLICATION FOR HEATING PERMIT (c nttnued from Revere Side) 11. LOCATION OF JOB_ Ld 941/12 NO. —STREET FLOOR APT. NO. 12. TYPE OF INSTALLATION: OIL BURNER ELECTRIC Cl VENTILATION SPRINKLER I GAS BURNER El STACK El INCINERATOR MISCELLANEOUS 64 ( IDENTIFY SIZE LOCATION SIZE SIZE13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. An/o B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED i7ly—i NEW OR OLD BUILDING -, INSULATED — YES OR NO f TYPE OF WALL WiLrd t w INSULATIONINSULATIONROOFORCEILINGp tie r AVG. SYSTEM WATER TEMP. y B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 0—ga" FAHRENHEIT MAKE OF RADIATION. B SEBO . COPPER CO VE PRS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. le T DESCRIs. TO BE I OINE; ON OF WORKj/Cif 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ROOM SIZE wlNDows AREA - SQUARE FEET B.T.U. e.T.u.DISTRIBUTION INSTALLEDANDDOORSVOLUMETOTALTOTALy ROOM NO.GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT TD•F CORRECTED J j 4 4 REGISTER L W M AND Q TEMP. TO r TYPE AND SIZE RAD. OR LEADER lIZE < WALL f' TO INFILT.) DIFF. F m N SQ. FT. FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND 12 Gs B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B/ C) FACTOR EL 17. ELECTRICAL WORK BY: ( y1.1C A / NAME ADDRESS SUBCONTRACTORS AND 18. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. J, 7 DATE SIGNAT APPLICANT K CONSTRUCTION- WALL WINDbWS ROOF OR CEILING BASEMENT HEIGHT: ABOVE GRADE BELOW GRADE DESIGN WATER TEMPERATURE DESIGN TEMP. DIFF COL.1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ROOM SIZE WINDOWS AREA•SQ. FT. FLOOR VOLUME BASEBOARDS AND DOORS CU. FT TO tA1. TOTAL l3[E NOTE) CORRECTED ACCESSORIES ROOM NuwLER GROSS GLASS NET WALL CEILING n AT:'D. WATER LENGTH O / TE'.IF. TO T1;MP ni, F ENCLOSURE L R S 14 MISC.L W H oN AREA WALL c DI IF. FIN 512E i 7 0 Z 7 TUBE1. 13 0 2 0 1 oS TEMP DIFF. FT, a 1 069 3 81 00 900 00 da oo 1200 00 o o a 600 78Dv 8 / 6 y8 ( Y CL v- G g`''• 00 d o goo 700 a Soo a o 1 0o yoo 00 3 3 yoo oo soo oa 2300 `000 ,440 13 G a 1 Io 4, //0 2-o 3-a /o ,r 00 Roo 600 yoo /zoo ` 9©D 5600 0 io o 00 13n, to l0 8 00 DD Soo oo /000 2v0iD 3 NOTE: FOR CONCRETE FLOOR ON GROUND OR FILL AT GRADE LEVEL,USE LINEAR FELT OF EXPOSED EDGE. TOTALS rA_l 04n n