HomeMy WebLinkAbout1395 John Fitch Boulevard (3)MATERIALS ESTINGINC.
200 ROWE AVENUE • MILFORD, CONNECTICUT 06460 • (203)878-2765871STAFFORDROAD • EAGLEVILLE, CONNECTICUT 06268 • (860)487-1972
NVLAP ACCREDITED#
0320 DATE: 09-24-98
REPORT NO: M-1000
CLIENT: Pelletier Builders AMBIENT TEMP: 630F138MainStreet
Coventry, CT 06238 WEATHER: Clear
PROJECT: t`tsj101it11tl/j//Farm Tek C044,
1394 John Fitch Blvd. wari£ '';.
South Windsor, CT t;•'
a
SUBJECT: CONCRETE PLACEMENT INSPECTION ENSii '
AL
Concrete Placement Locations: Wall and pier footings f Z 3
p gs along column lines:
A from 1 to 5
5 from AtoF
J from 1 to 5
Total Concrete Yardage This Date: 40 cubic yards @ 3000 PSI
All reinforcing steel was properly placed in accordance with drawings:
S-1, S-2, S-4, dated 9-1-98.
Cylind rs, slump and air content were performed and are as reported on Compression TestResultSheet. This report will follow when compression strength test results are know n.
Remarks: 1 set of 4 cylinders were cast.
Materials Testing, c. Inspector,
Er' Sib rg
2cc: Client Frank A. Soucy
paa
Test reports may not be reproduced without the express permission of Materials Testing,Inc. Test reports must not be used to claim product endorsement by NVLAP or any agency of theU.S.Government. Results only relate to items tested.
ATERIALS TESTING INC*9200ROWEAVENUE • MILFORD, CONNECTICUT 06460 • (203)878-2765871STAFFORDROAD • EAGLEVILLE, CONNECTICUT 06268 • (860)487-1972
NVLAP ACCREDITED
0320 DATE: 10-02-98
REPORT NO: M-1001
CLIENT:Pelletier Builders, Inc. AMBIENT TEMP: 580F138MainStreet
Coventry, CT 06238 WEATHER: Cloudy
PROJECT: Farm Tek rZ e,,
1395 John Fitch Blvd.
A
South Windsor, CT AA 1
C.
SUBJECT: CONCRETE PLACEMENT INSPECTION
Concrete Placement Locations: Walls & Piers: A line/ 1- 5
5 line/A- 10' past E
5 line/ H.1 - J
J line/ 1- 5
Total Concrete Yardage This Date: 50 cubic yards Q 3000 PSI
All reinforcing steel was properly placed in accordance with drawings:
S-1, S-2, S-3, 7-15-98.
Cylinders, slump and air content were performed and are as reported on Compression Test ResultSheet. This report will follow when compression strength test results are known.
Remarks: None.
Materials Testing, In Inspector,
Ri McK nna
Frank A. Soucy
2cc: Client
paa
Test reports may not be reproduced without the express permission of Materials Testing,Inc. Test reports must not be used to claim product endorsement by NVLAP or any agency of theUSGovernmentResultsonlyrelate10itemstested.
i
ATERIALS TESTING, INC.
200 ROWE AVENUE • MILFORD, CONNECTICUT 06460 • (203)878-2765
871 STAFFORD ROAD • EAGLEVILLE, CONNECTICUT 06268 • (860)487-1972
NVLAP ACCREDITED DATE: 10-09-98
0320
REPORT NO: M-1002
CLIENT:Pelletier Builders, Inc. AMBIENT TEMP: 60°F
138 Main Street
Coventry, CT 06238 WEATHER: Light rain
PROJECT: Farm Tek 40
1395 John Fitch Blvd. M At);'•y.,
if 4 iSouthWindsor, CT
SUBJECT: CONCRETE PLACEMENT INSPECTION
r,SINAI
Concrete Placement Locations: Foundation wall on 5 line G to J.2.
Total Concrete Yardage This Date: 10 cubic yards @ 3000 PSI Concrete.
All reinforcing steel was properly placed in accordance with drawings:
Fox Steel #R-1, 9-8-98.
Cylinders, slump and air content were performed and are as reported on Compression Test Result
Sheet. This report will follow when compression strength test results are known.
Remarks: None.
Materials Testing, Inc. Inspector,
Drew Fraser
Frank A. Soucy
2cc: Client
paa
Test reports may not be reproduced without the express permission of Materials Testing,Inc. Test reports must not be used to claim product endorsement by NVLAP or any agency of theU.S.Government. Results only relate to items tested.
ATERIALS TESTING, INC.
j A 200 ROWE AVENUE • MILFORD, CONNECTICUT 06460 (203)878-2765
W111ft=0011F 871 STAFFORD ROAD • EAGLEVILLE, CONNECTICUT 06268 • (860)487-1972
NVLAP ACCREDITED DATE: 10-26-98
0320
REPORT NO: M-1003
CLIENT:Pelletier Builders, Inc. AMBIENT TEMP: 50OF
138 Main Street
Coventry, CT 06238 WEATI „f Clear
C O14 -I*
v,
PROJECT: Farm Tek rtl-' A f:•;i
1395 John Fitch Blvd. ar;-'
South Windsor, CT I
t #1bb8l
EN y", ,, '
SUBJECT: CONCRETE PLACEMENT INSPECTION
Concrete Placement Locations: Slab on grade-complete building.
Total Concrete Yardage This Date: 250 cubic yards of 4000 PSI Concrete.
Cylind rs, slump and air content were performed and are as reported on Compression Test
Result Sheet. This report will follow when compression strength test results are known.
Remarks: None.
Materials Testing, Inc. Inspector,
Dre Fraser
2cc Client
Frank A. Soucy
Igb
Test reports may not be reproduced without the express permission of Materials Testing,Inc Test reports must not be used to claim product endorsement by NVLAP or any agency of theUSGovernmentResultsonlyrelatetoitemstested
n
MATERIALS TESTING INC.MV0A0'ff'
1%1*M011F 200 ROWE AVENUE • MILFORD, CONNECTICUT 06460 • (203)878-2765
871 STAFFORD ROAD • EAGLEVILLE, CONNECTICUT 06268 • (860)487-1972
NVLAP ACCREDITED DATE:-_ __ 10-23-98
0320
REPORT NO: M-1005
r
CLIENT:Pelletier Builders, Inc. AMBIENT TEMP: 580 F
188 Main Street
Coventry, CT 06238 WEATHER: Partly Cloudy
PROJECT: Farm Tek EN a ,,
1395 John Fitch Blvd. 4•
South Windsor, CT
60
SUBJECT: CONCRETE PLACEMENT INSPECTION 0*.
l
Concrete Placement Locations: Piers on 2 - 3 - 4 Line, D Line - E.1 Line, G.1 Line
Total Concrete Yardage This Date: 38 cubic yards of 3000 PSI concrete.
All reinforcing steel was properly placed in accordance with drawings:
Pelletier Builders S-1, 7-15-98.
Cylind rs, slump and air content were performed and are as reported on Compression T st
Result Sheet. This report will follow when compression strength test results are known.
Remarks: None.
Materials Testing, Inc. Inspector,
Drew Fraser
aA
Frank A. Soucy
2cc: Client
paa
Test reports may not be reproduced without the express permission of Materials Testing,Inc. Test reports must not be used to claim product endorsement by NVLAP or any agency of theU.S.Government. Results only relate to items tested.
A/0^"41
MATERIALS TESTING, INC.
mi,h1vol 200 ROWE AVENUE • MILFORD, CONNECTICUT 06460 (203)878-2765
1`.o0l" 871 STAFFORD ROAD a EAGLEVILLE, CONNECTICUT 06268 • (860)487-1972
oJVLAP ACCREDITED DATE 11-09-98
0320
REPORT NO. M-1006
CLIENT Pelletier Builders, Inc.AMBIENT TEMP: 40OF
138 Main Street
Coventry, CT 06238
WEAT Partly Cloudy
PROJECT Farm Tek O - C` x
1395 John Fitch Blvd. A;°,.'`'. `F C+'
South Windsor, CT Cj
ilk e
SUBJECT Concrete Placement Inspection 1
SIONAL0401140111011
Concrete Placement Locations: Slab on deck between columns 1 & 5 from "D" to H.2.
Total Concrete Yardage this Date: One hundred-ten (110) cubic yards at 4000 PSI.
Wire mesh placed.
Cylinders, slump and air content were performed and are as reported on Compression Test Result Sheet.
This report will follow when compression strength test results are known.
Remarks: None
Materials Testing, Inc.,
Inspector,
Drew Fraser
Frank A. Soucy
2cc Client
nik
Test reports may notbe reproduced without the express permission ofMaterials Testing,Inc Test reports must not be used to claim product endorsement by NVLAP or any agency of the U S.
Government Results only relate to items tested
R
ATERIALs ESTIN G, NC
j 200 ROWS AVENUE MILFORD, CONNECTICUT 06460 ,p (203)878-2765
1`0/1V 871 STAFFORD ROAD • EAGLEVILLE, CONNECTICUT 06268 • (860)487-1972
NVLAP ACCREDITED DATE: 10-22-98
0320
REPORT NO: M-1007
CLIENT: Pelletier BLfilders, Inc.v'``Ga138MainStreet
Coventry, CT 06238 s'400- A°
n';
4=
it ilottsl
PROJECT: Farm Tek g,•,,I
EN O:4.
1395 John Fitch Blvd. A117
South Windsor, CT
SUBJECT: FIELD DENSITY TESTING - (ASTM D-2922-D-3017 & PROCTOR ANALYSIS
ASTM D-15579)
Note: test#'s 8 & 9 were tested on existing on site sandy materials. Client was notified Density
Testing were based on improved gravel proctor and do No. 7 correlate with proctor analysis.
Results are for client's information only (Virgin on site material).
Material: Imported Gravel.
Proctor Value: 128.4 PCF.
Optimum Moisture: 9.1%.
x
MOISTURE PERCENT
TEST NO. LOCATION & ELEVATION CONTENT - %COMPACTION
1 Footing @ 2-D lines.- 7.5 123.5 96.1
Elevation: bottom of footing.
2 Footing @ 3-D lines. 7.8 122.0 95.0
Elevation: bottom of footing.
3 Footing @ 4-D lines. 8.1 121.8 94.9
Elevation: bottom of footing.
4 Footing @ 2-E.1 lines. 8.8 122.9 95.7
Elevation: bottom of footing.
5 Footing @ 3-E.1 lines. 6.6 122.3 95.2
Elevation: bottom of footing.
6 Footing @ 4-E.1 lines. 6.4 121.6 94.7
Elevation: bottom of footing.
Page 1 of 2
Client: Pelletier Builders, Inc. 10-22-98
M-1007
Project: Farm Tek ,. Page 2 of 2
1395 John Fitch Blvd.
South Windsor, CT.
MOISTURE PERCENT
TEST NO. LOCATION & ELEVATION CONTENT - %COMPACTION
7 Footing @ 2-G.1 lines. 7.1 123.5 96.2
Elevation: bottom of footing.
8 Footing @ 3-G.1 lines. 6.6 120.9 94.2
Elevation: bottom of footing.
9 Footing @ 4-G.1 lines. 5.1 120.5 93.8
Elevation: bottom of footing.
r
Materials Testing, Inc. Inspector
Richard Wright
Frank A. Soucy
2cc Client
Igb
Test reports may not be reproduced without the express permission of Materials Testing,Inc Test reports must not be used to claim product endorsement by NVLAP or any agency of the
U S Government Results only relate to items tested