Loading...
HomeMy WebLinkAbout137 Cornerstone Drive (3)eectric P 1-7o S0 APPLICATION FOR BUILDING PERMIT Plumbing# _ O G7 137 Cornerstone Drive WAC # (o Date: 6 N6. 27274 Sprinkler# FINAL APPRO LS Estimated Cost 0= Building a3-01 COMPLETE RED BOXED AREAS P rmit Fee 30 2 E4 ing TYPE OR PRINT ONLY ccupancy Fee Affidavit SIGN ON REVERSE SIDE Appr.for CO.Total Feesz- TO BIAl M DEPARTMENT,TOWN OF SOUTH WNDSOR,CT Additional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location r Lot No. Side of Street Zone Applicant Tel Address Zip Lic.# Own r Address Architect Address . 0 Sq.Ft.New Area: 1st FI. 2nd FI. 3rd Fl. Total New Area Rooms Lavatories Bathrooms Garages Purpos of this permit: IAR) City Water Well Septic System Sewer , Ins. H.O. P. Cert. Area 59(ol Basement 2O 9 Garage Z Approved by Dat 31 ed Use Group Construction Type r' R*rsW 1197 I hereby agree to conform to all the requirements of Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector y alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to ed the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in is i building and its use is allowed. Signed I hereby apply for a Certificate of O r the work described in this application for the permit. Signed DO NOT W ITE LOW THIS LINE INSPECTION COMMENTS Location of Job:AFFIDAVIT Additional Fee$ - 0 - State of Connecticut ss.South Windsor County of Hartford Owner 1 of Agent for the building erected Contractor under Permit No. 27274 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not exceed the submitted estimated cost Signed Subscribed and sworn to before me this day of A.D.20 Estimated Cost S 255,850 Difference: S (2 2, 9 0 5) Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment 27274-B 233,850 B01 FOOTING 09/19/00 CJD A W/CONTRACTOR B02 FOUNDATION 09/27/00 JFF A WITH CONTRACTOR FOUNDATION WATERPROOFING AN FOOTING DRAINS P02 UNDERGROUND 11/15/00 JFF A LEFT APPROVAL STICKER E01 SERVICE 11/21/00 JFF A B05 FIREPLACE/CHIMNEY 11/30/00 CJD A THROAT OK- W/OWNER B03 FRAMING (ROUGH) 12/08/00 CJD D RESCHEDULE INSP. B03 FRAMING (ROUGH) 12/11/00 CJD D HIP RIDGE BEAM CONNECTIONS LACK INTEGRITY BOB J. TO GET ARCHET. OR ENGNR. OPINION B03 FRAMING (ROUGH) 12/29/00 CJD A W/OWNER PO4 GAS TEST 01/16/01 JFF A LEFT APPROVAL STICKER E03 ROUGH 01/17/01 CJD A W/ELECT. P03 ROUGH 01/17/01 CJD A W/BOB JACKSTON B04 INSULATION 01/24/01 CJD A W/CONTRCTR E09 OTHER 02/15/01 CJD A VISIT SITE TO ANSWR. ?IS ON SERV. PANEL. SUPPLY DUCT IN DEDICTD. SPACE. NEED SWTC.C.ST B10 FINAL 04/23/01 CJD A W/BOB JACKSON B10 FINAL 04/23/01 CJD A CLOSED OUT. 10967-H 7,000 10674-P 10,000 17050-E 5,000 Total Est Value 255,850 Dwelling 3,969 191,623.32 Basement 2,049 29,095.80 Garage 824 11,700.80 Smoke Det 7 525.00 BOCA Value 232,944.92 Difference 22,905.08) Inspection / Approval Date By Appl t Code Description Due Whom Code Comment 27274-B 233,850 B01 FOOTING 09/19/00 CJD A W/CONTRACTOR B02 FOUNDATION 09/27/00 JFF A WITH CONTRACTOR FOUNDATION WATERPROOFING AN FOOTING DRAINS P02 UNDERGROUND 11/15/00 JFF A LEFT APPROVAL STICKER E01 SERVICE 11/21/00 JFF A B05 FIREPLACE/CHIMNEY 11/30/00 CJD A THROAT OK- W/OWNER B03 FRAMING (ROUGH) 12/08/00 CJD D RESCHEDULE INSP. B03 FRAMING (ROUGH) 12/11/00 CJD D HIP RIDGE BEAM CONNECTIONS LACK INTEGRITY BOB J. TO GET ARCHET. OR ENGNR. OPINION B03 FRAMING (ROUGH) 12/29/00 CJD A W/OWNER PO4 GAS TEST 01/16/01 JFF A LEFT APPROVAL STICKER E03 ROUGH 01/17/01 CJD A W/ELECT. P03 ROUGH 01/17/01 CJD A W/BOB JACKSTON B04 INSULATION 01/24/01 CJD A W/CONTRCTR E09 OTHER 02/15/01 CJD A VISIT SITE TO ANSWR. ?IS ON SERV. PANEL. SUPPLY DUCT IN DEDICTD. SPACE. NEED SWTC.C.ST B10 FINAL 04/23/01 CJD A W/BOB JACKSON B10 FINAL 04/23/01 CJD A CLOSED OUT. Inspection / Approval Date By Appl Code Description Due Whom Code Comment 10967-H 7,000 10674-P 10,000 17050-E 5,000 SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 137 CORNERSTONE DR LOT_##19 Reviewed By d L Bering) ROBERT N. JACKSTON Date Reviewed 6 a jApip5rove Denied 330 ABBE ROAD EXT,SOUTH WINDSOR,CT Reviewed By o\ ing) BP_#_27274_ Ph_##_296-9560- Date Reviewed 1J" enied Date Submitted 00/00/00 FOR f 0 As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1/ 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; V a. sanitary sewer/septic system V b. foundation drain S.AdwN _CN8,cK C. electrical & telephone td. water e. other CIA s Y 5. Sewer connection charge paid 6. Appropriate certification t 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. Pavement Excavation No. COMMENTS: SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUTT 137 CORNERSTONE DR LOT_##19 Reviewed By FW#.Engineerin ) ROBERT N. JACKSTON Date Reviewed 8 %3 v Approve Denie 330 ABBE ROAD EXT,SOUTH WINDSOR,CT Reviewed By v BP_#_27274_ Ph_#_296-9560- Date Reviewed W rov e Date Submitted 08/23/00 FOR 2tJILjING In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: d' 31 fi Approved Denied N/A 1. Name, address & phone number of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, street address. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record C. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: S kD (I rMo Co JS L oa v mil/ Awi WA As 61ow• oN VtAJUCi o ALA ow AffPve> 5cr :-)% )j EOM Q(V s IV O SAAl UN ENG,CEP N DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT MIT#R Application is hereby:TOWN OF SOUTH WINDSOR 170,5-0 PER BUILDING DEPARTMENT APPROVED' 1540 SULLIVAN AVENUE Bldg.Permit# Z.fj QINU 644-2511 ext. 230 Date BuildiQ Inspector 7 Application must be printed or typed FEE SCHEDULE Location of Job: X, 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS w APPLICANT PHONE# W N .S OWNER l//o1'r"rTr/.f1 a POq OWNER ADDRESS tea Sou CO ! E., OWNER PHONE G ESTIMATED COST$ 5 10 Vr IS THIS A CONTRACT COST? JO Yes O No FEE ENCLOSED$ TYPE OF JOB:l)S R.Cpl` 91 Original Installation 13 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION?arYES NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD yArJr 10";qe-,y SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS /NUMBER OF DISCONNECTS A RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? YES NO NUMBER OF LIGHT CIRCUITS 2 NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES d 6 NUMBER OF OUTLETS 7-1 NUMBER OF LIGHT FIXTURES Ya NUMBER OF HEAT CIRCUITS /to NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK A.. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 0 - 6 John Collins-CRS Approvalon irmation: equest o. age From: clpsvc@nu.com> To: COLLIN@SOUTHWINDSOR.ORG> Date:11/30/00 12:41 PM Subject: CRS Approval Confirmation: Request No. 162485 Your approval of the following CRS Request has been successfully processed. CRS Work Request#: 162485 House No: 137 or. Lot No: Street Name: DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR yBUILDINGDEPARTMENT APPRO D 1540 SULLIVAN AVENUE Bldg.Permit# t (C w 114"!, 644-2511 ext. 230 9 ?a?y Date Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE 13 ? 'a,ci UC S T oti 0-$1)000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT gy L At K 10 3&Z APPLICANT ADDRESS 90 wa t co r T s TWAYv,LL b e-f o APPLICANT PHONE# Of " 7 5-3 oZ 001 OWN 3 OWNER Ig O/3 A-e-KST oA/ q OWNER ADDRESS OWNER PHONE ESTIMATED COST$ zD, od O IS THIS A CONTRACT COST? 0 Yes RtNo FEE ENCLOSED$ l,3 G• O TYPE OF JOB: OR C New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YES NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS [NO.OF LAVATORIES (v NO.OF CONDUCTORS SIZE NO.OF STACKS .2. SIZE 3 AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK 6 t wrye SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER 3 L WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK 4L 6 O t-Ttt F K Lt- THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE l- /y-ea DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR PE 6BUILDINGDEPARTMENT0 APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#644-2511 ext. 230 Date Buil g Inspector Application must be printed or typed FEE SCHEDULE A0111- Location of Job: 3 9 Co 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS o APPLICANT PHONE# OWNER O P7NSFqOWNERADDRESS E A tot OWNER PHONE C ESTIMATED COST$o 0 IS THIS A CONTRACT COST? JYes 0 No FEE ENCLOSED$_ TYPE OF JOB: KM Original Installation 13 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: CHEATING ff RESIDENTIAL IAA/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC Ad WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE 4 OF INSIDE 7d OF DIFFERENCE o OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEA ING EQUIPMENT(INCLUDING MAKE&MODEL NO.) r_A j rh ` ef_Tcli_G o GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) a ' TYPE OF FUEL OIL-GPM a GAS-INPUT ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING q/16DESIGNTEMP. OUTSIDE OF INSIDE b OF DIFFERENCE CZ;P OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DES I IL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) D Ct) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3 S>,57-p g3 C17- CONTRACTORS LICENSE NO. E STATE SIGNATURE OF APPLICANT DATE /c /® a r t CALL/PLUS HEAT LOSS/GAIN CALCULATION BY E & K HEATING & AIR CONDITIONING LLC FOR INFORMATION OR TO PLACE AN ORDER CALL (860) 496-9327 (860) 584-8677 Software Copyright (C) 1987-1996 by Ed Horgan (H.V.A.C. ) (610) 384-1923 DESIGN: WINTER, 70 DEGREES DIFFERENCE SUMMER, 20 DEGREES DIFFERENCE JOB: JACKSTON - RESIDENTIAL CALCULATION HTM HTM AREA BTU/HR BTU/HR DATE: 12-12-2000 HEAT COOL OR #LOSS GAIN BASEMENT - UNHEATED NO LOSS OR GAIN BATH RM # 1, WEST & NORTH HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 20 X 64 IN, NO 31 . 0 64 . 0 9 276 569 CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0 HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 90 252 0 EXHAUST FAN, 45 CFM WITH . 05 USAGE FACTOR 3 . 8 1 . 1 45 170 50 LATENT HEAT EXHAUST FAN ALLOWANCE 0 . 0 1 . 9 45 0 84 WALL 9 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 72 302 122 WALL 10 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 81 340 138 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 136 . 9 17 . 1 9 1232 154 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 20 . 1 9 0 181 ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 . 0 2572 514 0 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 43 3086 1033 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN KITCHEN, EAST & NORTH HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 70 X 48 IN, NO 31 . 0 64 . 0 23 723 1493 1 WINDOW DOUBLE GLASS LOW E 72 X 80 IN, NO 31 . 0 64 . 0 40 1240 2560 CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0 HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 460 1288 0 WALL 23 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 144 605 245 WALL 20 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 117 491 199 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 101 .4 12 .2 63 6391 770 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 14 .4 63 0 904 ALLOWANCE FOR APPLIANCES AND MOTORS 0 . 0 2 . 0 600 0 1200 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 219 10738 6467 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT - (6 IN ROUND) OR (7 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES : 2 #661 14 X 4 SIDEWALL REGISTER OR 2 #411 4 X 12 FLOOR DIFFUSER OR REQUIRES : 2 #16 8 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 2 #650 10 X 6 INCH RETURN AIR GRILL, OR TWO 3-1/4 X 14 IN-WALL RETURN FAMILY ROOM, NORTH & EAST HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 60 X 76 IN, NO 31 . 0 19 . 0 32 982 602 I a CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0 HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 336 941 0 WALL 7 X 9 FT, FRAME OR VENEER, R19 INSUL 4 . 2 1 . 7 31 130 53 2 WINDOWS DOUBLE GLASS LOW E 24 X 76 IN, N 31 . 0 64 . 0 25 785 1621 FIREPLACE WITH LOOSE DAMPER 28 . 0 0 . 0 9 252 0 WALL 16 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 87 365 148 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 82 .4 9 . 6 57 4697 550 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 11 . 3 57 0 646 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 114 8152 2974 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN SUNROOM, EAST & SOUTH HEAT COOL VALUE LOSS GAIN 4 WINDOWS DOUBLE GLASS LOW E 28 X 76 IN, N 31 . 0 64 . 0 59 1832 3783 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 140 252 140 HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 140 392 0 WALL 14 X 10 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 81 340 138 3 WINDOWS DOUBLE GLASS LOW E 28 X 76 IN, N 31 . 0 32 . 0 44 1374 1419 WALL 10 X 10 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 3 13 5 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 20 . 9 2 . 6 103 2156 264 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 3 . 0 103 0 310 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 195 6333 5739 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT - (6 IN ROUND) OR (7 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES : 2 #661 14 X 4 SIDEWALL REGISTER OR 2 #411 4 X 12 FLOOR DIFFUSER OR REQUIRES : 2 #16 8 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 2 #650 10 X 6 INCH RETURN AIR GRILL, OR TWO 3-1/4 X 14 IN-WALL RETURN STUDY, SOUTH HEAT COOL VALUE LOSS GAIN 3 WINDOWS DOUBLE GLASS LOW E 28 X 67 IN, N 31 . 0 32 . 0 39 1212 1251 CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0 HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 224 627 0 WALL 16 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 105 441 179 INFILTRATION, LOSS 1 . 2 AC/HR GAIN . 5 AC/HR 79 . 0 9 . 6 39 3080 374 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 11 . 3 39 0 439 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 75 5360 1804 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES : 1 #661 10 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN LIVING ROOM, SOUTH & WEST HEAT COOL VALUE LOSS GAIN 2 WINDOWS DOUBLE GLASS LOW E 28 X 76 IN, N 31 . 0 32 . 0 30 916 946 CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0 HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 224 627 0 WALL 14 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 96 403 163 3 WINDOWS DOUBLE GLASS LOW E 28 X 76 IN, N 31 . 0 64 . 0 44 1374 2837 WALL 16 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 70 294 119 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 41 . 6 5 . 1 74 3080 374 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 5 . 9 74 0 439 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 150 6694 4439 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 12 X 4 SIDEWALL REGISTER OR 2 #411 4 X 10 FLOOR DIFFUSER OR REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN FOYER, WEST HEAT COOL VALUE LOSS GAIN 2 WINDOWS DOUBLE GLASS LOW E 7 X 46 IN, NO 31 . 0 64 . 0 4 139 286 1 WINDOW DOUBLE GLASS LOW E 36 X 80 IN, NO 31 . 0 64 . 0 20 620 1280 CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0 HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 168 470 0 WALL 12 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 84 353 143 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 96 . 3 11 . 9 24 2310 286 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 14 . 0 24 0 336 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 67 3892 1995 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 1 #661 10 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN DINING ROOM, WEST HEAT COOL VALUE LOSS GAIN 2 WINDOWS DOUBLE GLASS LOW E 20 X 76 IN, N 31 . 0 64 . 0 21 654 1351 1 WINDOW DOUBLE GLASS LOW E 32 X 76 IN, NO 31 . 0 64 . 0 17 524 1081 CEILING UNDER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 0 0 0 HARDWOOD FLOOR, Rll INS OVER ENCLOSED SPAC 2 . 8 0 . 0 195 546 0 WALL 13 X 9 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 79 332 134 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 70 . 9 8 . 7 38 2695 330 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 10 .2 38 0 388 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 98 4751 2896 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES : 1 #661 12 X 4 SIDEWALL REGISTER OR 1 #411 4 X 10 FLOOR DIFFUSER OR REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN MASTER SUITE, SOUTH & WEST HEAT COOL VALUE LOSS GAIN 3 WINDOWS DOUBLE GLASS LOW E 24 X 24 IN, N 31 . 0 32 . 0 12 372 384 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 306 551 306 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 306 0 0 WALL 18 X 10 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 168 706 286 3 WINDOWS DOUBLE GLASS LOW E 32 X 64 IN, N 31 . 0 64 . 0 43 1323 2731 WALL 17 X 10 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 115 483 196 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 85 .4 10 .4 55 4697 572 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 12 .2 55 0 672 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 813 671 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 174 8945 5146 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 12 X 4 SIDEWALL REGISTER OR 2 #411 4 X 10 FLOOR DIFFUSER OR REQUIRES: 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 2 #650 10 X 6 INCH RETURN AIR GRILL, OR TWO 3-1/4 X 14 IN-WALL RETURN BATH MASTER, EAST & SOUTH HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 45 X 46 IN, NO 31 . 0 64 . 0 14 446 920 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 182 328 182 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 182 0 0 EXHAUST FAN, 45 CFM WITH . 05 USAGE FACTOR 3 . 8 1 . 1 45 170 50 LATENT HEAT EXHAUST FAN ALLOWANCE 0 . 0 1 . 9 45 0 84 WALL 14 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 98 412 167 1 WINDOW DOUBLE GLASS LOW E 69 X 46 IN, NO 31 . 0 32 . 0 22 683 705 WALL 13 X 8 FT, FRAME OR VENEER, R19 INSUL 4 . 2 1 . 7 68 286 116 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 62 . 0 7 . 3 36 2233 264 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 8 . 6 36 0 310 ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 . 0 4558 912 0 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 547 361 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 94 6017 2765 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES : 1 #661 12 X 4 SIDEWALL REGISTER OR 1 #411 4 X 10 FLOOR DIFFUSER OR REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN MASTERCLOSET, EAST HEAT COOL VALUE LOSS GAIN CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 117 211 117 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 117 0 0 WALL 13 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 104 437 177 INFILTRATION (NO WALL OR CEILING OPENINGS) 0 . 0 0 . 0 0 0 0 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 65 44 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 11 713 338 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR REQUIRES: 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN BALCONY, WEST HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 60 X 72 IN, NO 31 . 0 64 . 0 30 930 1920 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 264 475 264 V FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 264 0 0 WALL 12 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 66 277 112 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 107 . 8 13 .2 30 3234 396 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 15 . 5 30 0 465 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 492 404 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 105 5408 3096 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN BED ROOM # 2, EAST HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 100 X 64 IN, N 31 . 0 64 . 0 44 1378 2844 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 165 297 165 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 165 0 0 WALL 15 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 76 319 129 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 45 . 5 5 . 5 44 2002 242 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 6 . 5 44 0 284 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 400 507 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 132 4396 3887 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN BED ROOM # 3 , WEST HEAT COOL VALUE LOSS GAIN 2 WINDOWS DOUBLE GLASS LOW E 32 X 64 IN, N 31 . 0 64 . 0 28 882 1820 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 196 353 196 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 196 0 0 WALL 14 X 8 FT, FRAME OR VENEER, R19 INSUL 4 . 2 1 . 7 84 353 143 INFILTRATION, LOSS 1 . 2 AC/HR GAIN . 5 AC/HR 85 . 3 10 . 2 28 2387 286 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 12 . 0 28 0 336 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 398 367 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 95 4373 2812 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES : 1 #661 12 X 4 SIDEWALL REGISTER OR 1 #411 4 X 10 FLOOR DIFFUSER OR REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN BATH RM # 1, WEST HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 20 X 48 IN, NO 31 . 0 64 . 0 7 207 427 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 60 108 60 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 60 0 0 EXHAUST FAN, 45 CFM WITH . 05 USAGE FACTOR 3 . 8 1 . 1 45 170 50 LATENT HEAT EXHAUST FAN ALLOWANCE 0 . 0 1 . 9 45 0 84 WALL 6 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 41 172 70 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 110 . 0 12 . 6 7 770 88 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 14 . 8 7 0 103 ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 . 0 1427 285 0 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 171 104 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 27 1883 799 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN BATH RM # 2, EAST HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 20 X 48 IN, NO 31 . 0 64 . 0 7 207 427 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 72 130 72 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 72 0 0 EXHAUST FAN, 45 CFM WITH . 05 USAGE FACTOR 3 . 8 1 . 1 45 170 50 LATENT HEAT EXHAUST FAN ALLOWANCE 0 . 0 1 . 9 45 0 84 WALL 8 X 8 FT, FRAME OR VENEER, R19 INSUL 4 .2 1 . 7 57 239 97 INFILTRATION, LOSS 1 . 2 AC/HR GAIN . 5 AC/HR 132 . 0 15 . 7 7 924 110 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 18 . 5 7 0 129 ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 . 0 1670 334 0 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 200 113 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 30 2204 869 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES : 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR REQUIRES : 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN BED ROOM # 4, SOUTH & WEST & EAST HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS LOW E 100 X 64 IN, N 31 . 0 32 . 0 44 1378 1422 CEILING UNDER VENTILATED ATTIC, R38 INS 1 . 8 1 . 0 238 428 238 HARDWOOD FLOOR, R30 INS OVER OPEN SPACE 3 . 6 1 . 0 238 857 238 WALL 14 X 13 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 138 580 235 WALL 17 X 13 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 177 743 301 WALL 17 X 13 FT, FRAME OR VENEER, R19 INSU 4 .2 1 . 7 177 743 301 INFILTRATION, LOSS 1 .2 AC/HR GAIN . 5 AC/HR 108 . 5 13 . 0 44 4774 572 LATENT HEAT INFILTRATION ALLOWANCE 0 . 0 15 . 3 44 0 672 DUCT IN UNCONDITIONED SPACE 0 . 10 0 . 15 SUB 950 496 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 146 10453 3803 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES : 2 #661 12 X 4 SIDEWALL REGISTER OR 2 #411 4 X 10 FLOOR DIFFUSER OR REQUIRES : 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES : 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN WHOLE BUILDING LOSS GAIN LATENT GAIN FROM ALL SOURCES 6950 r SYSTEM DESIGN: REQUIRED SUPPLY TRUNK DUCT IS 40 X 8 REDUCED 2 INCHES EVERY 30 FEET REQUIRED RETURN TRUNK DUCT IS 46 X 8 REDUCED 2 INCHES EVERY 30 FEET GRAND TOTAL BTU HEAT LOSS AND SENSIBLE + LATENT figjAT GAIN (fFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM TRUNK VELOCITY OF 10140 FPM 1775' ' 93398 57812 his certifi.'d that this plan and sp,.cificotions are tn.- copies of the proposed building or alterations to a erected at 3 7r,-QrA el-.S h "Dr. together with amendments stated m application a filed with plan and 1 agree to comply with all zonin, i ufiding and state laws and such orders as shall t suf d by the Building Department during pendent of this application and finaf issuance of a bulidin. oermit. Signed his plan ie approved subject to the condition that orders and ordinances :^gulatine building shall be piwd with Siac fly Approved The6e flied with il,•g I,ispc:ctor Cfer CONSULTING STRUCTURAL ENGINEERS CIANCI (A CIANci December 14, 2000 Re: Cornerstone Drive, 137 South Windsor, CT Simsbury, CT 00 13101 Mr. Curtis Bubie New England Carpentry, Inc. 55 Airport Road, Suite 201 Hartford, CT 06114 Mr. Bubie: At your request, we made a visit to the above referenced residence on December 12, 2000. The purpose ofour meeting at the site was to observe the workmanship of the existing roof framing system and offer our opinion on those items which are of concern to you. The following is a list of the concerns we discussed and our recommendations for the required repairs: We recommend that 2 x 6 or 2 x 8 diagonal ties be installed at each existing 2 x 8 ceiling joist at the master bedroom/bathroom area. These ties must connect the typical ceiling joist to the upper ceiling joists over the master bedroom. We recommend that one 2 x 10 rafter be sistered to the existing 2 x 10 rafter that supports the 14" LVL hip located over this area. We recommend that a new post consisting of 3 -2 x 6's be installed at the existing 14" LVL valley beam. This post must be located over the partition between the foyer and master bedroom. Additional 2 x 4's must be added in this partition to transfer the load dowm to the double joist below. We recommend that 2 x 4 strong backs be installed at 3)2" on center over the ceiling joists at the master bedroom. These strong backs must horizontally tie the 2 x 10 rafters to the existing attic floor framing. We recommend that a new post consisting of 3 -2 x 6's be installed at the existing 14" LVL valley beams over bedrooms#2 and#4. This post must be located over the bearing wall below. Additional 2 x 4's must be added to transfer the load down to the supporting beams. .An additional two ply 13"x 9'R"LVL transfer beam must be added into the second floor framing below the new post at bedroom#2. We recommend that 2 x 6's @ 16" on center collar ties be installed throughout the entire attic area. We recommend that two additional 2 x 6 studs be added to the existing stud located under the bottom end of the 14" LVL valley beam in bedroom #2. We recommend that the two existing 14" LVL hip boards located above bedroom#3 be removed and replaced with 2 x 12's. The existing LVL is cut down in width at the bottom 193 Wethershold Avenue. Hartford, ConnectiCLIL OG 1 14-1 1 13 Phone (FG01 527-6415 TeI(-;f;,x: 1,24;n1 :):1 ?-'I r119 Cornerstone Drive, 137 South Windsor, CT Page 2 end and is very poorly fitted at the ridges. We also recommend that 2 x 6 or 2 x 8 ceiling joists be installed in ;this area. We recommend that 2 x 6 or 2 x 8 ceiling joists be installed at the family room/sun room area to tie the two exterior wall plates together. The connection of the ceiling joist to the rafters and any splices in the ceiling joist must contain a minimum of 12 - 12d nails. Please be advised that we have not thoroughly inspected the entire residence nor have we performed computations to confirm code compliance of the member sizes used. The recommendations noted above address workmanship and generally accepted framing details in the industry. We trust that this meets your needs at this time. PoiC'AtN Y Very truly yours,w CIANCI & CIANCI Ronald E. ZurefV Staff Engineer CIANCI&CIANCI CONSULTING STRUCTURAL ENGINEERS LAW OFFICES OWAINGS,LANZA AND PURNF AGEN,L.L.C. 1610ELL,INGTON ROAD POST OFFICE BOX"7 SOUTH W1NDSCW,CONN.Yf074-M7 FAX(W)644-3347 EDWARD R KUEHN OFCOUNM HAROLD R.CUMMINGS MICHAEL I LANZAVQTCE1VTJ.puRNIIAGEN August 24,2000 Town of south Windsor Building Dept. 1540 Sullivan Avenue South Windsor,Ct. 06074 RE: Lot No. 19 Cutler Ridge II Subdivision To Whom It May Concern: H. It is Cornerstone Associates,LLC,the owner of Lot No. 18 in Cutler Ridge buildingIrepresent153Corneliedforabuing that Mr.Robert Jackston,the owner of Lot No. 19,has applied of m client'smygrantedunlessheisabletomodifythegradeY permit,and this permit will not be property in order to satisfy Town slope regulations. l ston has my client's permission to have a temporary slope right Please be advised that Mr. Jac easement over Lot No.18 so that he can move forward with the construction of improvements on Lot No. 19. have an uestion with respect to ve,please feel free to contact me. If you ha Y Q i t chael J.Lanza r Robert N. Jackston 330 Abbe Road Ext. South Windsor, Ct 06074 August 25,2000 Town of South Windsor Building Dept. 1540 Sullivan Avenue South Windsor, Ct 06074 Re: Regarding Lot No. 18 Cutler Ridge II Subdivision To Whom It May Concern: I Robert N. Jackston,the owner of Lot No. 19, 137 Cornerstone Drive, Cutler Ridge II Subdivision,does grant to 153 Cornerstone Associates the owner of Lot No. 18 permission to enter and regrade my property as necessary upon the installation ofthe proposed retaining wall as depicted on the Cutler Ridge II Subdivision plans. Should you have any questions,please feel free to call me at 860-296-9560. Sin ly, Ro N. ackston a I u Jl 0 . 06 01 13 . 00 + 0 U 2 26 . 00 0+-;2 Q. r26 ° OOG 4 UU 0 . 00 ifr-S Fi( o 9 o° C 3 0 CONSULTING STRUCTURAL ENGINEERS CIANCI a CIANCI December 14, 2000 Re: Cornerstone Drive, 137 South Windsor, CT Simsbury, CT 00 13101 Mr. Curtis Bubie New England Carpentry, Inc. 55 Airport Road, Suite 201 Hartford, CT 06114 Mr. Bubie: At your request, we made a visit to the above referenced residence on December 12, 2000. The purpose of our meeting at the site was to observe the workmanship of the existing roof framing system and offer our opinion on those items which are of concern to you. The following is a list of the concerns we discussed and our recommendations for the required repairs: We recommend that 2 x 6 or 2 x 8 diagonal ties be installed at each existing 2 x 8 ceiling joist at the master bedroom/bathroom area. These ties must connect the typical ceiling joist to the upper ceiling joists over the master bedroom. We recommend that one 2 x 10 rafter be sistered to the existing 2 x 10 rafter that supports the 14" LVL hip located over this area. We recommend that a new post consisting of 3 -2 x 6's be installed at the existing 14" LVL valley beam. This post must be located over the partition between the foyer and master bedroom. Additional 2 x 4's must be added in this partition to transfer the load down,to the double joist below. We recommend that 2 x 4 strong backs be installed at 32" on center over the ceiling joists at the master bedroom. These strong backs must horizontally tie the 2 x 10 rafters to the existing attic floor framing. We recommend that a new post consisting of 3 - 2 x 6's be installed at the existing 14" LVL valley beams over bedrooms#2 and#4. This post must be located over the bearing wall below. Additional 2 x 4's must be added to transfer the load down to the supporting beams. An additional two ply 1"4" x 9" "LVL transfer beam must be added into the second floor framing below the new post at bedroom#2. We recommend that 2 x 6's @ 16" on center collar ties be installed throughout the entire attic area. We recommend that two additional 2 x 6 studs be added to the existing stud located under the bottom end of the 14" LVL valley beam in bedroom #2. We recommend that the two existing 14" LVL hip boards located above bedroom #3 be removed and replaced with 2 x 12's. The existing LVL is cut down in width at the bottom 1 198 Wethersfield Avenue, Hartford, Connecticut 061 14-1 1 13 Phone (860) 527-6415 Trk-Jax• (Can) P•,19-1 1 3 J Cornerstone Drive, 137 South Windsor, CT Page 2 end and is very poorly fitted at the ridges. We also recommend that 2 x 6 or 2 x 8 ceiling joists be installed in ;this area. We recommend that 2 x 6 or 2 x 8 ceiling joists be installed at the family room/sun room area to tie the two exterior wall plates together. The connection of the ceiling joist to the rafters and any splices in the ceiling joist must contain a minimum of 12 - 12d nails. Please be advised that we have not thoroughly inspected the entire residence nor have we performed computations to confirm code compliance of the member sizes used. The recommendations noted above address workmanship and generally accepted framing details in the industry. We trust that this meets your needs at this time. CO'A1N very truly yours, AA g ,. % CIANCI & CIANCI r cS .'' "`' Ronald E. ZurefVIle Staff Engineer CIANCI&CIANCI CONSULTING STRUCTURAL ENGINEERS