Loading...
HomeMy WebLinkAbout1343 Sullivan AvenueApplication No. .... .?..7. Permit No. .2.;16....................... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. hereby make application for a permit to ( make alteration to) a building according to the following detailed statement of the specifications and plans herewith submitted. (Draw a line through word "erect" or words "make alteration to" as the case may require.) All provisions of the Building By-Laws (Sections 2 to 32 inclusive) shall be complied with in the execu- tion of this work whether specified herein or not. South Windsor, Conn., 19......... Signhere ........................... Address I...f ....4..1/...e......../1;, Location?V-.g...................................side of? ........... Nearest cross street? v..,l./'-oz7.. ........f Street No. ................'............................. Lot No. ...... 7Owneroflandis? /.. ...' `.. P ... 4-y t;t.Address .......... i 17..................................................... ...................... Ownerof building is? ........ ..rn.. .....................................Address .... ....... Architect is? .......................................`r ..................................................Address ............. Builderis? ............... @.h.. Address ..................................................................................................................... Dimensions of building? ..0..X.a;...Feet rear? Feet front.Feet deep. ............................. Extrant height to highest point of roof? ................................................................ ... No. of stones in height? .......n'7er.............. Purposeof building is? ....... e................................No. of stores? ........................................................................................................ l Howmany families? ..................................................................................-...No. of rooms? .... ................................................................................................... Distance from street line is? ...................................................................from building line is? ....................................................................................... ADDITIONS AND ALTERATIONS Give Brief Description) i MapNo. ............................., If of steel frame, what is exterior construction? ''....'. What kind of columns used? ................................................................Size of columns used? ---. ''.................... ................ .. Whatlength mf columns used? ............ -_---................ '--.How What kind of beams or Size of beams or Longestspan of beams or These rest on? '-' --'— ........................................................................ Roof construction is? ............................. covering is? . ..................................................................................... The floors are of ............ -' --'-—- ---- construction and are calculated to carry a ma6n load of . ' -'' '.............. lbs. per square foot. See Section l4, Building By-Laws.) BRICK ON. Of what material will wmDm be constructed? _..................... .................. .................................................................................................... _____ Compositionof mortar? ..................................................................................................................................................................................................................... Height and Thickness of Walls Height Stories Front Walls Side Walls Rear Walls Partition Walls1stStory 4th 'I 6th Old 8th Cc Material of Front? - --' .......... - fstone, mhmx kind.? Thicknessof Ashlar? ' —' '.... ........................................................Thickness of Backed up with what? --' Arches or lintels over WOOD CONSTRUCTION. Give Size, Longest Span and Distance Between Centres, of Joists, Girders and Columns JOISTS GMDI S COLUMNS Floors Size Longest Span Centres ffik%ing Size Longest Span Centres Size Length Centres 1st Floor Via.....«.... a.......... .............. .................................. 4th " Size of outside studs? .... .... ............ Distance on centres? ..............S Q.................... Size of sill? ............................................... Size of rafters? A Distance on centres?............?..... .............. Size of plate? Size of ledgers or girts? .................................................................................Size of deck rafters? ...................................................................... ............... Av Distance on centres? ........................................................................................Size of studs in bearing partitions? ...... MISCELLANEOUS Style of roof, flat, pitch, Mansard, or hipped? ......:.l.. t---47*0 Fireplaces? `.. Material of roof covering? Material of Cornice? ........................... How is building heated? ..................... Lining of flues? ... ...........".`:...........':....................................................... Thickness of shell of flues? .......................'"':.....................................Any elevators or lifts. ............................................................ .. Whatkind? How many. ....................................................... Any hoi.stways? .. ,...................................................... How protected? ................. ....... ................................................ .................Total Value of Building .................... When will work be commenced? .... .. The applicant warrants that the lot for residential purposes, shown on a plot plan accompanying this appli- cation, has 20,000 square feet, or more, and at least 100 foot frontage on a Town road shown on a map of South Windsor showing Town Roads dated December 1949, or on any other roads officially accepted by the Town of South Windsor since 1949. t licant 2418 BUILDING APPLICATION Application No. ..............26.7.9.............................................. on the .........W....e....s....t Side of Sulli-t,ran Ave. Street. StreetNo, .......................... ........................................................... Owner .......MU Ia. Ade-1.1-a....Dayton........ E/ Applicant ..1.111..o.....D.ayt.qn............................................ .... CLASSIFICATION r,-,ar.ag.e..... .............................. ..................... Permit issued on above Application. Date, . .....Mlzu-at......Ts.. ... 19...... gli111 aw k TOWN OF SOUTH WINDSOR BUILDING PERMIT Date Aua ust 7 t 19 58 Fee Paid y$ 3•.00 Est. Value y$ 50 0.00 Permit 1r 0 2 418 on the West side of Sullivan Ave, Street Street No. f-5 V3 Owner Flilo & Adella Da ton Applicant Milo Dayton CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Finish garage r BUILDING PERMIT N? 2418 OFFICE OF THE BUILDING INSPECTOR of the Town of' South Windsor, Conn. South Windsor, Conn.Augu®t To 19 -58 i94i's ta to Tertifil., That silo Dayton is hereby granted permission to Finis1. garage at estimated value of 5()Q 000 on the s side of sull1VE'm Ave• Street on land owned by Milo & Adella Dayton Said Work to be as described in Application No. 267 and.to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR I Issued Au3. ust 7, 19 58 Pudding Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers dur- ing the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." TO THE BUIU)ING INSPECTOR of dw APPLICATION FOR TO" OF WOW W ADSM COS.PLAN EXAMINATION AND BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, /it, IV, and IX. I 1 I-k ZONING AT (LOCATION)DISTRICT. CATION ct+o., I` j'RgET) OF Cr"E R CBETWEENilAND BUILDING CROSS STREET) CROSS STREET) LOT SUBDIVISION LOT LOCK SIZE V1 II. TYPE AND COST OF BUILDING — A11 applicants complete Parts A — D Xl A. TYPE OF IMPROVEMENT D. PROPOSED USE - For"Wrecking" most recent use T 1 Now building Residential Nonresidential 2 Additi n(1 residential, enter number I 12 One family 18 Amusement, recreational of new housing units added, if any, in Part D, 13) 13 Two of more family - Enter 19 Church, other religious number of units- - - - - 20 Industrial3 Alteroti n (See 2 above) 14 Transient hotel, motel, 21 Parking garage4F7Repair, replocoment or dormitory - Enter number 5 Wrecking (it multifamily residential. o/ units ------- - -i 22 Service station, repair garaq enter number of units in building in 15 Garage 23 Hospital, institutional Part D. 13) 16 R ther arport 24 Office, bank, professional 17 6 Moving (r location) Sp eci/y 25 Public utility7 F undation only 26 School, library,other •dueoti nel B. OWNERSHIP I cM 27 Stores, mercantile 8 Privet (individual, corporation,28 Tanks, towers nonprofit instirution, etc.) 29 Other - Speczly 9 Public (F deral, State, or col q vornmont) C. COST Omit cents) Nonresidential - Describe in detail proposed use of buildings, •.g., fa d processing plant, machine shop, laundry budding at hospital, el•m nta y 10. Cost of improvement,,,,,,,,,,,,,,,, school, secondary school, college, parochial school, parking garage for department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... b. Plumbing ...................... c. H ating, air conditioning......... d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT $ III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Ports E — L; for wrecking, complete only Port J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 Masonry(wall bearing) 40 F] Public or private company 48. Number of stories................ 31 W ad from 41 Private(septic tank, etc.) 49• Total square feet of floor area, all floors, based on exterior 32 Structural steel dimensions ..................... 33 R inforeed concrete H. TYPE OF WATER SUPPLY 34 Other - Specify 42 Public or private company 50. Total land area, sq. ft. ........... 43 [= Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35 Gas Will they b central air 52. Outdoors........................ 36 Oil c nditi ning?L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 Yes 45 No 53. Number f Is drooms. 36 Coal 39 Other- Specify Will there be an elevator? 54. Number i Full.......... 46 Yes 47 No bathrooms Partial........ I IV. IDENTIFICATION — To be c mpl ted by all applicants Nan+ Meiling eddr ss — Number, street, city, and State ZIP code T I. N Owner or Lessee Contractor tf3 A 3. Architect or Engineer Th own of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Application dot Signatur V/1'r34' pplica t ess y-k-'A DO NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plan Review Date Plans Date Plans By Notes Plans R view Required Check Fee Started By Approved BUILDING PLUMBING MECHANICAL S ELECTRICAL S OTHER is VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Date Number 3y Check Date Number By Permit or Approval Check Obtained Permit or Approval Obtained PLUMBING BOILER CURB OR SIDEWALK CUT ROOFING SEWER ELEVATOR SIGN OR BILLBOARD ELECTRICAL STREET GRADES FURNACE USE OF PUBLIC AREAS GRADING EECKINGOILBURNER HER OTHER Fui DATION r numb r f(o Bui Iding 19 7 Permit issued Building i Permit Fe A r ved by: TITLE TOWN OF SOUTH WINDSOR BUILDING PERMIT Date Ali , 19 87 Fee Paid $. .S.QQ Est. Value $.IIA. Permit N° 16171 on the side of f Sullivan Street Street No. Owner K9r-MLT,CA INC i 1 ''7ApplicantRenttKaltim CERTIFICATE OF OCCUPANCY ISSUED: Date t, No. Fee Paid $ CLASSIFICATION Demo1i.ti-o r amage t BUIIDING PERbffr N° 161'71 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. 8/6 19 87 94is is to Crrtff;, That Scott Kelley/RSK-KELLCO. INC. is hereby granted permission to i pMo 1 igh a gar-age at estimated value of $ N 1 A on the side of 1343 Sullivan Avenue Street on land owned by RSK-KELLCO, INC. Said Work' ' to be as described in Application No. 16469 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issued 19 87 J '". -a4 Q A 11Z Building Inspector. Streets and sidewalks, obstructed by ezcavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." PERMIT # 16; • Application For W S DEPARTMENT DECISION PP 65HenningPermit APPLICATION Is HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS APPROVED DISAPPROVED TOWN OF SOUTH WIN DSOR oQ OATH CNINF ovacTM A/KICATUNIS MOST BE PNIMTEO OR 111090. BEGIN •ITM WOMEN Oft OELON 9 rS •E 1. LOCATION OF JOB i1 ~ No. STREaT LOT 110. FLOOR AFT. NO. O SOWNER ADDRESS A.PHONE S. APPLICANT O. ADDRESS ter w B. LICENSE NO. S 1 1,47 Q 71II- EXPIRATION DATE OF LICENSE (d- k' / 10. ESTIMATED COST O 11. Ni THIS A CONTRACT COM YES Noa o(a. FEE ENCLOSED OU 1A. TYPE OF WILOINO: 00 RESIOEMTML L_7 COMNENc1AA V 14. TYPE F Joo:INDUSTRIAL ALTERATIONxWSIACATIONADDITIN APPLICATION FOR HEATING PERMIT cam— flum ptwome ade) 11. LOCATION OF JOB No* iTRsst rLoom ART.No. IL TYPE Of INSTALLATION: OIL BURNER Cl ELECTRIC YENTRLATION SlRINKL 6A8 BURNER STACK ClINCINERATOR MIsCELLANEOUs LOCATION AENNTSIZESI 1S. OFTANK OF TANK FILL 14. B.T.U. EQUIP. AT REGISTER._,^_FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B•T.U. OR SQ. FT. GROSS—FlRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OR WORK c, 1s. TO BE DON • V` 1s. NEAT LOSS WjIEDULE. (TO BE INCLUDED FOR ALL JOBS: AR<A - SONAR< RttT T• @•T•w' O s OISTRI UT1 N INSTALLED woor sass AND 000ws a an $STsw Mo.00=s 46AM 14W• COUNG r oow W.R. wT 7r s wwo. Tor Tv s wMo=t Ow 69wosw woor ` M 'wro ww t IIII/ILT.) a F g Awst wwsw t TOTALS A. HEAT LOSS FROM BUILDING B.T.UJHR B. DOMESTIC HOT WATER DEMAND B.T.UJHR C. PIPING.OTHER THAN NORMAL B.T.UJHR ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY:. s ADORM SUBCONTRACTORS AND Is. THEM TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE PPLICATION TO BE COMPLETELY FILLED IN. JOB/ZONE NAME; - RSK 1 CDC? INDOOR WINTER DESIGN TEMP - 70 ? ' WATTS PER SQ. FT. - LIGHTS - 3 ? LIGHTS FLUORESCENT - Y? OTHER ELECTRICAL LOADS (WATTS/SQ.FT) - 0 ? O.K. INPUT TOTAL OTHER ELECTRICAL (WATTS )- 0 ? TERM AIR TEMP CLG - 55 ? TERM AIR TEMP HTG - 120 ? SUPPLY FAN EtiT STATIC PRESS - 2 .75 ? SUPPLY FAN ARR. : 1=D.T. , 2=B.T. - 1 ? BUILDING- ORIENTATION 1=N,S,E,W 2=NW,NE,SE, SW - 1 ? DRAPE COLOR: 1=LT, 2=MED, 3=DARK, 4=NONE, 5=OTHER - 4 ? ENTER THE TRANSMISSION FACTOR FOR THE N. WALL - .06 ? IS TRANS. FACTOR THE SAME FOR ALL WALLS (Y/N) - N? ENTER THE TRANSMISSION FACTOR FOR THE S. WALL - .04 ? ENTER THE TRANSMISSION FACTOR FOR THE E. WALL - .06 ? ENTER THE TRANSMISSION FACTOR FOR THE W. WALL - .06 ? ENTER THE TRANSMISSION FACTOR FOR THE ROOF - . 08 ? TYPE OF GLAS;3:S=SINGLE,D=DOUBLET=TRIPLE,O=OTHER (S,D,T OR 0) -D? INPUT VENT C. M AS 1. = PER SQ l T 2 . PER PERSON 3. .= AS % OF -SUPPLY CFM 4 . = TOTAL 3 ? SUPPLY AIR OF VENT. AIR(0 TO 10 0 )- 10 ? INFIL -CFM/SQ FT HTG - 0 ? INFIL. CFM HTG - 0 ? SQ FT/PERSON - 48 ? PEOPLE ACTIVITYI=SEATED AT REST (THEATER, ETC. ) 2=OFFICE WORKER 'OR RETAIL STORE 3=SEDENTARY WORK (RESTAURANT)4=FACTORY, LIGHT WORK 5=HEAVY WORK6=OTHER- 3 ? CHOOSE <B>LOC:K LOAD OR <Z>ONE LOAD ( B OR Z ) - B? ENTER LENGTH OF N. OR S. WALLS (FEET) - 110 ? ENTER --LENGTH OF -E.- OR W. WALLS (FEET) - 44 ? ENTER TOTAL HEIGHT OF WALLS (FEET) - 8 ? FLOORS - 1 ? CEILING PLENUM - RETURN AIR PLENUM (Y/N) - N? CALCULATE SHADING FOR OVERHANGS OR REVEALS(Y/N) - N? SPECIFY GLASS AREAS AS1. TOTAL2. % OF WALL AREA--SAME FOR ALL EXPOSURES (1 OR 2 ) ENTER-AREA OF N. WINDOWS (SQ. FT. ) - 188 ? ENTER AREA OF S. WINDOWS (SQ. FT. ) - 72 ? ENTER AREA OF E. WINDOWS (SQ. FT. ) - 48 ? ENTER AREA OF W. WINDOWS (SQ. FT. ) - 48 ? COOLING % SAFETY FACTOR ( 0 TO 30 ) - 0 ? WARM-UP FACTOR ( 0 TO 100 ) - 0 ? EN.TER .TOTAL OTHER ELECTRICAL (WATTS )- 0 ? RSK 1 CDC 06/02/87 HARTFORD CONNECTICUT LAT = 42 ALT = 58 1CONST 70W/40R/ 70B ID= 72/50 70 WALL COLOR: MEDIUM ROOF COLOR: MEDIUM SER# 30206831.6 D.B.TEMP TOTA.L, TONS RSH TONS CFM 1. JUN AT 9 A.M. 80 .6 13 .97 8 .97 5,758 2. JUL AT 9 A.M. 83 .6 14 ,60 9 .16 5,876 . R-_TOTAL ..OTHER ELECTRICAL (WATTS)- 0 7 RSK 1 CDC 06/02/87 HA'RTFORD CONNECTICUT LAT = 42 ALT = 58 CONST= 70W/40R/ 70B ID= 72/50 ; 70 WALL COLOR: MEDIUM ROOF COLOR: MEDIUM SER# 30206831.6 D.B.TEMP TOTAL TONS RSH TONS CFM 1. JUN AT 9 A.M. 80 .6 13 .97 8 .97 5,758 2. JUL AT 9 A.M. 83 .6 14 .9-0 9 . 16 5,8.76_ 3. SEP AT 10 A.M. 78 .8 13 .87 9 .04 5,801 4 . OCT AT 2 P.M. 77 .0 13 .47 9 .11 5,849 5.-----SEP AT 3 -P.M. 88 .0 15.58 10 .00 6,418 6. JUL AT 4 P.M. 93.0 16.88 10 .45 6,709 7 . JUN AT 4 P.M. 90 .0 16. 20 10 .29 6,606 ZONE HEATING---> = 65 ,098 W/INFIL= 65,098 CFM = 1,184 INPUTS ORIENTATION OF BUILDING N S E W RF TRANSMISSION FACTORS 0 .06 0 .04 0 .06 0 .06 0 .08 GL F= .55 IS LI=FLO Y SHADE FACT=0 .96 NO. FLOORS 1 LENGTH = 110 WIDTH = 44 HEIGHT = 8 VA.= 10 OUTPUTS NUMBER OF PEOPLE = 101 SENSIBLE PEOPLE LOAD = 28, 233 TOTAL LIGHTS 14 ,520 LIGHTING LOAD 61,946 OTHER ELECTRICAL = 0 OTHER ELECTRICAL 0 - AREA OF N. GLASS = 188 NORTH GLASS SOLAR 21879 AREA OF S. GLASS = 72 SOUTH GLASS SOLAR 2 ,220 AREA-.OF E. GLASS = 48 EAST GLASS SOLAR 1,221. AREA OF W. GLASS = 48 WEST GLASS SOLAR 6 ,384 TOTAL GLASS AREA = 356 TOTAL GLASS SOLAR 12 ,704 TOTAL GLASS .AREA =. 356 TOTAL GLASS TRANS. -4,112 AREA OF N.• WALL - 692 N. WALL LOAD 727 4NREA OF S. WALL = 808 S. WALL LOAD 984 AREA OF E. WALL = 304 E. WALL LOAD 390 AREA OF W. WALL = 304 W. WALL LOAD 518 TOTAL WALL AREA . = 2 ,10 8 TOTAL WALL TRANS.2 ,619 - AREA OF ROOF 4, 840 ROOF LOAD 15,835 SAFETY FACTOR 0% SAFETY B.T. U.S 0 SUPPLY FAN H. P. =5 .28 FAN HEAT GAIN - DT - 16,197 VENTILATION CFM = 671 O.A. SENSIBLE LOAD - 15,497 NUMBER_ OF PEOPLE = 101 PEOPLE LATENT LOAD - - 27,225 VENTILATION CFM = 671 O.A. LATENT LOAD 18,199 TOTAL CFM-STD AIR= 6 ,709 TOTAL LATENT LOAD 45 ,424 ROOM SENSIBLE 125 ,450 ROOM LATENT 27 ,225 RSK 1 CDC GRAND TOTAL -LOAD = 202r568 BTU' S OR 16.88 TONS <-- LOAD RUN FOR # 6 . JUL AT 4 P.M. AREA (SQ FT) 4, 840 SQ FT/TON 287 TOTAL CFM-STD AIR= 6,709 CFM/SQ FT 1. 39 HEATING LOAD VENTILATION LOAD = 51,656 ROOF HEATING LOAD 27 ,104 GLASS HEAT LOAD = 13 ,706 WALL HEATING LOAD 7 ,722 INFILTRATION LOAD= 0 WARM UP LOAD 0 SLAB HEATING LOAD= 16 ,566 HEAT LOAD WITH VENT - 116 ,754 COIL SELECTION PARAMETERS DB TEMP ENT/LVG = 74 .1 / 52 .8 TOT SENSIBLE LOAD 157 ,144 WB TEMP- ENT/LVG = 62 .7 / 52 .2 TOTAL COIL LOAD 202 ,568 SPECIFIED ROOM RH= 50% RESULTING ROOM RH 53% a TERMINAL AIR TEMP= 55 .00 / 120 DEGREES ROTATED 0 SUPPLY FAN STATIC= 2 .75 NON-CEILING RETURN BLDG. 'U' FACTOR=0 .09 STAPLES DEFAULTS JOB/ZONE NAME - RSK 2 CDC? INDMR-"WINTER DESIGN TEMP - 70 ? WATTS PER SQ. FT. - LIGHTS - 3 ? LIGHTS FLUORESCENT - Y? OTHER ELECTRICAL LOADS (WATTS/SQ.FT) - 0 ?O.K. INPUT TOTAL OTHER ELECTRICAL (WATTS )- 0 ?PERM AIR TEMP CLG - 55 ? PERM AIR TEMP HTG - 120 ? SUPPLY FAN EST STATIC PRESS - 2 . 75 '?SUPPLY FAN ARR. : 1=D.T. , 2=B.T. - 1 ? BUILDING ORIENTATION 1=N,S,E,W 2=NW,NE,SE,SW - l ?DRAPE COLOR: 1=LT, 2=MED, 3=DARK, 4=NONE, 5=OTHER - 4 ?IiNTER THE TRANSMISSION FACTOR FOR THE N. WALL - 0 ?IS 'TRANS 'FACTOR THE SAME FOR ALL WALLS (Y/N) - N?INTER THE TRANSMISSION FACTOR FOR THE S. WALL - .06 ?ENTER THE TRANSMISSION FACTOR FOR THE E. WALL - .06 ?ENTER THE TRANSMISSION FACTOR FOR THE W. WALL - .06 ?ENTER THE TRANSMISSION FACTOR FOR THE ROOF - .08 ?TYPE OF GLA_SS:S=SINGLE,D=DOUBLE,T=TRIPLE,O=OTHER (S,D,T OR 0) -D?r NPUV VENT' CFM AS I. = PER SQ FT 7 . = PER PERSON 3 . = AS % OF SUPPLY CFM 4 . = TOTAL 3 ? SUPPLY AIR OF VENT. AIR(0 TO 100 )- 10 ?ZNPIL CFM/SQ FT HTG - 0 ? INFIL. CFM HTG - 0 ? ESQ FT/PERSON - 31 ? PEOPLE ACTIVITYI=SEATED AT REST (THEATER, ETC. ) 2=OFFICE WORKER OR RETA3=SEDENTARY WORK (RESTAURANT)4=FACTORY, LIGHT WORK IL STORE 5=HEAVY WORK6=OTHER- 3 ? C"HOOSE <B>LOCK LOAD OR <Z>ONE LOAD ( B OR Z ) - B?ENTER LENGTH OF N. OR S. WALLS (FEET) - 78 ?ENTER LENGTH' OF E. OR W. WALLS (FEET) - 20 ?ENTER TOTAL HEIGHT OF WALLS (FEET) - 8 ?FLOORS - 1 ? CEYLING 'PLENUM RETURN AIR PLENUM (Y/N) - N? CALCULATE SHADING FOR OVERHANGS OR REVEALS(Y/N) - N?SPECIFY GLASS AREAS AS1. TOTAL2. % OF WALL AREA--SAME FOR ALL EXPOSURES (1 OR 2 ) - 1ENTERAREA '40F N. WINDOWS (SQ. FT. ) - 0 ?ENTER 'AREA OF S. WINDOWS (SQ. FT. ) - 80 ?ENTER AREA OF E. WINDOWS (SQ. FT. ) - 48 ?ENTER-AREA_OF_ W: WINDOWS (SQ. FT. ) - 48 ?COOLING % SAFETY FACTOR ( 0 TO 30 ) - 0 ?WARM-UP FACTOR ( 0 TO 100 ) - 0 ?ENTER- TOTAL OTHER ELECTRICAL (WATTS )- 0 ? RSK 2 CDC HARTFORD__ -__ ' *CONNECTICUT 06/02/87LAT = 42 ALT = 58CONST= 70W/40R/ 70B ID= 72/50 70WALL- COLOR: MEDIUM ROOF COLOR: MEDIUMSER# 30206831 .E D.B.TEMP TOTAL TONS RSH TONS CFM1. J UN AT 9 A.M. 80 .6 6.09 3.81 2,4472.---JUL AT 9 A:M. 83.6 6.41 3.93 2,5203. SEP AT 10 A.M. 78 .8 6. 38 4 .09 2,6274 . OCT AT 2 P.M. 77 .0 6. 25 4 .17 216765. SEP AT 3 P.M. 88 .0 7 .06 4 . 46 2 ,8656 . 1 JUL AT 4 P.M. 93.0 7 .24 4 . 38 2,8137 . JUN AT 4 P.M. 90 .0 6. 90 4 .28 2, 747ZONEHEATING--> = 28 , 140 W/INFIL= 28, 140 CFM =512 INPUTSORIENTATIONOF13UILDINGN S E W RF,TR9NSMISSION FACTORS 0 nn n ng n nc f% „r ^ ^^ L RSK 2 CDC HAKTPOH'v 06/02/87*- CONNECTICUT LAT = 42 ALT = 58CONST= 70W/40R/ 70B ID= 72/50 70WALLCOLOR: MEDIUM ROOF COLOR: MEDIUM SER# 30206831.E D.B.TEMP TOTAL TONS RSH TONS CFM1. JUN AT 9 A.M. 80 .6 6.09 3. 81 2,4472JULAT- 9 X.M. 83.E 6.41 3.93 2,5203. SEP AT 10 A.M. 78 .8 6. 38' 4 .09 2,6274 . OCT AT 2 P.M. 77 .0 6. 25.4 .17 2,6765.. SEP AT 3 F.M. 88 .0 7 .0E 4 . 46 2,865 -6. JUL AT 4 F.M. 93.0 7 .24 4 . 38 2, 8137 . JUN AT 4 P.M. 90 .0 6 .90 4 . 28 2, 747ZONE--HEATING--> - = 28 , 140 W/INFIL= 28 , 140 CFM =512 INPUTS ORIENTATION OF BUILDING N S E W RFTRANSMISSIONFACTORS0 .00 0 .06 0 .06 0 .06 0 .08GLF= .55 IS LI=FLO Y SHADE FACT=0 .96 NO. FLOORS 1LENGTH = 78 WIDTH = 20 HEIGHT = 8 VA.= 10 OUTPUTS NUMBER OF PEOPLE = 50 SENSIBLE PEOPLE LOAD = 14,090TOTALLIGHTS4 ,680 LIGHTING LOAD 19 ,966OTHERELECTRICAL = 0 OTHER ELECTRICAL 0AREAOFN. GLASS = 0 NORTH GLASS SOLAR 0AREAOFS. GLASS = 80 SOUTH GLASS SOLAR 2 ,467AREAOFE. GLASS = 48 EAST GLASS SOLAR 1,221AREAOFW. GLASS = 48 WEST GLASS SOLAR 6 ,384TOTALGLASSAREA = 176 TOTAL GLASS SOLAR 10 ,072TOTALGLASSAREA = 176 TOTAL GLASS TRANS. =2 ,033 AREA OF N. WALL = 624 N. WALL LOAD pAREA-OF S. -WALL = 544 S. WALL LOAD 994AREAOFE. WALL = 112 E. WALL LOAD 144AREAOFW. WALL = 112 W. WALL LOAD 191TOTALWALLAREA = 1, 392 TOTAL WALL TRANS. 1,329AREAOFROOF1,560 ROOF LOAD 5,10 4 AFETY _FACTOR- -- - - 0% SAFETY B.T.U. S 0SUPPLYFANH.P. =2 .21 FAN HEAT GAIN - DT =6,790VENTILATIONCFM = 281 O.A. SENSIBLE LOAD --6 ,497NUMBEROF -PEOPLE = 50 PEOPLE LATENT LOAD --- 13,587VENTILATIONCFM = 281 O.A. LATENT LOAD 7,413TOTALCFM-STD AI_R= 2, $13 TOTAL LATENT LOAD 21,000 ROOM SENSIBLE 52,594 ROOM LATENT 13,587 RSK 2 CDC GRAND TOTAL LOAD =86,881 BTU' S OR 7. 24 TONS <-- LOAD RUN FOR # 6 . JUL AT 4 P.M. AREA—TS - FT) 1,560 SQ FT/TON 215DOTALCFM-STD AIR= 2 ,813 CFM/SQ FT 1.80 HEATING LOAD VENTILATION LOAD = 21,656 ROOF HEATING LOAD 8,736CLASSHEATLOAD = 6 ,776 WALL HEATING LOAD 3 ,226INFILTRATIONLOAD= 0 WARM UP LOAD pSLABHEATINGLOAD - 9 ,402 HEAT LOAD WITH VENT = 49 ,796 COIL SELECTION PARAMETERS DB TEMP ENT/LVG = 74 .1 / 52 .8 TOT SENSIBLE LOAD 65,8814BTEMPENT/LVG = 62 .9 ,/ 52 . 2 TOTAL COIL LOAD 86,881PBCIFIEDROOMRH= 50% RESULTING ROOM RH 54% rERMINAL AIR TEMP= 55 .00 / 120 DEGREES ROTATED 0UPPLYFANSTATIC= 2 . 75 NON-CEILING RETURN 3.I,DG. 'U' FACTOR=0 .09 STAPLES DEFAULTS VIM Sf y Y_ 7-0-Wt-Z, 01AeSGyUiA 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 r AREA CODE 203/644-2511SUR•C September 1 , 1987 RSK-KELLCO 1744 Ellington Road South Windsor, Connecticut 06074 Dear Mr. Kelley: An inspection for temporary Certificate of Occupancy was made September 1 , 1987 . Enough of the building has been completed to qualifyforatemporaryC . Of O.ai:. this time. ery ruly ours Thomas P. D' Auria Chief Building Official TPD/chm 4%, F?SKrKELLE(IINC. Developers Builders 1744 Ellington Road Property South Windsor, CT 06074 Managers Tel: 203-644-8761 / 644-8140 May 3, 1988 Ms. Marcia A. Banach, Director of Planning Mr. Michael J. Gantick, Director of Public Works Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 RE: Parking spaces at South Windsor Child Development Center Dear Ms. Banach and Mr. Gantick: This is to confirm that we are in agreement with the parking plan at the Child Development Center and have no need for an additional space. Yours truly, 3 . Milo M. Dayton CC A. Bowen Davies, Deputy Town Engineer Building Department- Richard J. Sartor, Town Manager We Build Our Reputation MEMORANDUM TO: John Collins, Chief Building Official FROM: Marcia Banach, Director of Planning Michael Gantick, Director of Public Works /4 DATE: May 10, 1988 RE: South Windsor Child Development Center, Sullivan Avenue The Certificate of Occupancy for the above-noted project has been withheld pending completion of site improvements contained in the approved site plan. All site improvements have been satisfactorily completed and the C.O. may be released. cc: Richard J. Sartor, Town Manager Raymond Hallowell, Chairman, PZC 1313 Sv itI cIA-Al &e_ t01101 sF( t f 4 r 011 c 1 1540 SULLIVAN AVENUE SOUTH WINDSOR. CONN. 06074v AREA CODE 203/644-2511 SOR•CO March 9, 1988 Mr. Richard S. Kelley RSK-KELLCOI Inc. 1744 Ellington Road South Windsor, CT 06074 Re: South Windsor Child Development Center Dear Mr. Kelley: Please be advised that your request for a Certificate of Occupancy for the above-referenced site has been denied based on the following deviations from the approved site plan and/or items not shown on the as-built plan: 1 . The building is two feet higher than proposed. 2 . Contours not shown on as-built plan. 3 . Fences not shown on as-built plan; one fence appears to encroach on abuttor. 4 . Outfall in detention pond appears to be about two feet higher than the bottom of the pond. 5 . Grading appears to direct runoff onto neighbor's property. 6 . Three doors on the north side of the building do not appear on either the proposed plan or the as-built plan. 7 .Walkways are not as approved. 8 . The 1000-gallon propane tank does not appear on the approved site plan--was it installed with Building Dept/Fire Marshall approval? 9 . Utility connections to the Dayton house are not shown. 10 . The playground shown on the approved plan isn't shown on the as-built. 11. Dumpster pad isn't shown on the as-built. 12 . The as-built does not indicate whether the number of parking spaces provided is in conformance with the approved site plan. 13 . Site lighting is not as approved. All of the above items/issues must be resolved prior to issuance of a Certificate of Occupancy. Very truly yours, LAI Marcia A. Banach Michael J. `Gantick Director of Planning Director of Public Works cc: A. Bowen Davies, Deputy Town Engineer Building Department tOviN 9E4 o7-0-wn' 0-k Sau_tA ?dzqdS.O.'t w 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 rCOAREA CODE 203/644-2511nsOR• C1 April 14 , 1988 Mr. Richard S. Kelley RSK-KELLCO, INC. 1744 Ellington Road South Windsor, Connecticut 06074 Re : Child Development Center CERTIFIED MAIL 1343 Sullivan Avenue Dear Mr. Kelley: A temporary Certificate of Occupancy was issued to you for the above captioned building. That temporary Certificate of Occupancy was issued several months ago and ample time has passed to enable you to complete any work required by the Planning and Zoning Commission. This is to inform you that if all the work required by the Planning and Zoning Commission is not completed within thirty days , the temporary Certificate of Occupancy will be rescinded and the entire building shall be vacated. If I can be of any assistance in this matter, please con- tact me. Very truly yours, Thomas P. D' Auria Chief Building Official ENCLOSURE: 1 . cc : Richard J. Sartor, Town Manager Richard Hallowell, Jr. , PZC Marcia Banach, Director of Planning Michael Gantick, Director of Public Works John M. Moran, IWA/CC Bd. of Directors, Child Development Ctr. RSK KELLE[IINC. Developers Builders 1744 Ellington Road Property South Windsor, CT 06074 Managers Tel: 203-644-8761 / 644-8140 April 15, 1988 Marcia Banach Director of Planning Michael Gantick Director of Public Works Town of South Windsor 1540 Sullivan Avenue South Windor, Connecticut 06074 RE: SOUTH WINDSOR CHILD DEVELOPMENT CENTER This letter is in reponse to your letter dated March 9, 1988, addressing concerns needing our attention in order to obtain a permanent Certificate of Occupancy. All items have been addressed individually and, in our estimation, meet the requests made by the Commission and Town Staff. Please be advised we did not deviate from the approved plans without the consent of Mr. Martel or Mr. Davies during the construction period. Ad- justments were made to better locate the building on site and to follow the Planning and Zoning Commission's suggestion that the site be developed with care and with the neighbors in mind. 1. The building was raised two feet to establish a more workable grade between the existing house, the new building and the abutting property owner. This adjustment was made in the field in consultation with the Town Engineer. The height of the building does not exceed regulations. 2. The contours were shown on the As-Built plan dated 9/10/87 and are shown on As-Built dated April 1988. 3. The fence is shown on revision dated April 1988. 4. The outfall and detent area are as designed and approved. 5. The existing site and the approved site plan showed more surface run-off than our completed grading. The As-Built shows that we eliminated as much surface run-off as the site will permit. 6. North exterior doors, decks and stairs are on the As-Built revised April 1988. 7. The present walks were constructed to accommodate a handicap ramp from the parking lot to the entrance door. Parking lot elevations were modified to eliminate the need for retaining walls, with the approval of the Town Engineer. We Build Our Reputation SOUTH WINDSOR CHILD DEVELOPMENT CENTER, Page 2 8. The propane tank was installed by Fuels, Inc, with required approvals. 9. The Dayton house utilities were added to As-Built plan dated April 1988. 10. Playground is shown on As-Built dated April 1988. 11. The dumpster pad is shown on As-Built dated 9/10/87 and again on revision dated April 1988. 12. There are two (2) more parking spaces on site than approved. 13. The type and location of site lights changed based on on-site inspection for best possible illumination of parking area and in consideration of others residing near the CDC building. We believe we have addressed your concerns. The site and building reflect improvements made in the field during construction that had been suggested by the Town Staff to make the site and building fit as naturally as possible into the existing setting. Yours truly, C6441 Richard S. Kelley6114, President RSK/ck cc A., Bowen Davies, Deputy Town Engineer ilding Department Richard J. Sartor, Town Manager Raymond Hallowell, Jr. , Planning & Zoning Commission John M. Moran, Chairman Inland Wetlands Agency/Conservation Commission Board of Directors, Child Development Center