HomeMy WebLinkAbout1343 Sullivan Avenue (5)PLANNING AND ZONING COMMISSIONs, APPLICATION FORM
so.•c°'
V,Application No. : z) P 4 ' • 44
Date Received:
Action/ by; o , g 2 I98SReceiptNo. : SEP
APPLICANT: RSK-KELLCO A,RSK-KELLCO
ADDRESS: 1744 Ellington Road South Windsor, CT 06074 TELEPHONE: 644-8761
OWNER OF RECORD ON LAND RECORDS: RSK-KELLCO
ADDRESS: 1744 Ellington Road South Windsor, CT
COMPLETE LOCATION OF PROPERTY:1343 Sullivan Avenue W. Side Sullivan Avenue
Assessors Map 97 Lot 13
ZONE: RR
NAME, ADDRESS, & TELEPHONE NUMBER OF PERSON TO WHOM INQUIRIES SHOULD BEDIRECTED:
Attorney Bruce Fader
Kahan) Kerensky,Capossela,Levine & Breslau
45 Hartford Turnpike, Box K, Vernon, CT 06066 TELEPHONE:• 646-1974
THIS APPLICATION IS FOR: (Check one of the following)
I . Zone Change to Public Hearing required) .
XX 2. Subdivision .
3. Open Space Subdivision (Public Hearing required) .
4. Resubdivision (Public Hearing required) .
S. Special Exception to Article Public Hearing Required) .
6. Site Plan of Development.
7. Earth Filling [Section 101 and/or Earth Removal [Section 91PublicHearingRequired) .
8. General Plan of Development.
9. Regulation Amendment : Zoning Subdivision
10. Other (explain in detail) :
CONSULT PLANNING DEPARTMENT FOR FEE SCHEDULE. THIS APPLICATION MUST BESIGNED. BY THE APPLICANT AND OWNER OF THE PROPERTY AND SUBMITTED INTRIPLICATEWITHALLMAPSANDDOCUMENTSREQUIREDONATTACHEDCHECKLIST.
Applic t Own r
PLANNING AND ZONING COMMISSION
APPLICATION, CONT' D.
TIME FRAMES AND PROCEDURES FOR SUBMITTING APPLICATIONS/PLANS
1 . All prospective applicants are urged to confer with Town Planning
Department and Engineering Department staff prior to submission of any
application to the Commission .
2. Plans are officially received only on the fourth Tuesday of each month
at the Regular Meeting of the Planning & Zoning Commission (PZC) .
3 . Three (3) sets of blueprints are required on the second Tuesday of the
month for review by the Town Planning and Engineering Departments .
This deadline must be met if you want to ensure that your application
is officially received by PZC.
These plans m- be submitted as complete plans -- which includes
application plus all required information contained on checklist. No
plans will be accepted at the counter if checklist is incomplete. It
is the applicant ' s responsibility to ensure that all information
required on the checklist is submitted in one package at the time of
submission -- including landscaping plans, architectural elevati ns,
traffic report , etc . Planning Department staff will not accept
checklists with blank spaces , or with "by others" in any space.
4. Town staff will notify the applicant with any changes required to make
the plans in complete compliance with our Zoning/Subdivision
Regulations .
5 . All changes requested must be made and new, complete blueprints must
be submitted . At this time six sets of plans must be submitted . If a
Public Hearing is required ( or optional but likely) then seven sets
are required .
6 . Planning Department/Engineering Department staff will review plans
only once -- if the resubmissions are not complete/correct , the Town
Planner ' s report will reflect that revisions were not made as
requested .
UG 31 '88 17:05 K.K.C.L. B. 226 P02;05
f
CHECKLIST
4.Zjq
REQUIRED INFORMATION 11OP
0- 19a8SUBDIVISIONS & RESUBDIVISIONS
S,)uth Windsor
This checklist must be signed by plan preparer (*Aot )Zo2ingeclariinsi(R
that all required information is provided . Items 1-5 are requiredforAlapplications ; Items 6-9 required where appropriate .
Check mark for each item supplied ,
I . On each sheet for plans or maps , title block with thefollowinginformation :
a . Name and address of subdivider.
b . Name a n d addressdress of Land Surveyor or ProfessionalEngineer .
Y c . Name of subdivision .i ision .
d . Date when drawings were made.8
North arrows
2 . Key aM - Anr p overall map drawn to a scale of I inch
equals 200 feet , which can be used as an overlay onMetropolitanDistractMaps . This map will show theoverall, design of the subdivision and will include :
a. Layout of streets with names
f
b . Layout of lots and lot numbers!!
c . Open space land
d . Arrows indicating general direction of drainage
d e . Lines indicating sanitary sewer system flow
f . Total acreage ofg subdivision
g . Total number of lots
v h . Names of surrounding property-owners , and
properties within 500 feet of the site
3 • Plot Plan : A layout map of the proposed. subdivisiondrawntoascaleofIinchequals40feetoneither ofthefollowingsizesheets - ( 1) 25" X 37" with a 3/4"ruled margin ; (2) 15" X 24" with a 1/2" ruled margin -
containing the following data:
UG 31 '88 17:05 K.K.C.L.B. 226 P03/05
r/ a. Distance and bearings of all boundary lines ,
b . Lot layout numbers , square footage of all lots , and
all lot dimensions . Iron pins to be shown at all Tlotanglepoints . Lots should not be fragmented
onto separate sheets except where size is
prohibitive .
N A c . Proposed streets andwith center lane
stations , and curve data .
d . Building lines in accordance with zoning
regulations .
e. Easements , noting grantors , grantees , and purpose .
f . Proposed names of street .
S . Names of abutting property-owners .
h. Monuments will be indicated at corners and angles
of all streets and at all points of curvature and
tangency . , In areas accessible to Metropolitan
District Commission points , or other coordinated
points , the monumented points within proposed
subdivision shall be coordinated. These
coordinates shall appear in ' ta.bular form on the
plot plan . The accessibility of these MDC points
shall be determined by the Town Engineer .
i. All open space reserved for ...parks , playgrounds, or
other common or public uses shall be indicated .
J . A-2 Certification ; P .E. /L.S . Seal .
k. Traffic control signs and pavement markings
required by Traffic Authority.
4 ., Topographic Mapt A map drawn to . a scale of 1 inch to
40 feet on sheets not exceeding 25 inches by 37 inches
including ruled margins and shall , in addition to the
requirements of the plot plans , show the following :
a. All existing and proposed buildings.
b . Curb lines and pavement width , sidewalks.
C . Existing and proposed sanitary and storm sewers , if
any.
d . Existing and proposed water and gas main systems .
c% e... Present wooded areas indicated by a "foliage line" .
Any individual trees to be saved should be shown.
f . Existing and proposed contours shall be shown at8
not lass than two-foot intervals ; but in cases of
relatively level land , the contours. shall be
one-foot intervals .
C.L.B. T '` 226 PO4/05
g . Proposed storm drainage system showing all catch
basins , endwalls , manholes , lengths , and sizes of
Pipes . (Minimum distance between catch basins
shall be 300 feet and minimum size of storm drain
lines shall b 15 inches . )
h. Connections of all springs into proposed storm
drainage system as needed ,
i . Location and indications of existing brook
channels , and 100 year flood limits,
f J . A-2 Certification; P . E. /L,S. Seal
k . Regulated wetlands and 100-year flood plain or note
that site contains none .
s . Drains calculations - rDrainagecoZero Runoff Increase per
attached guidelines .
6. Plans and Profiles : A plan and profile of-' the propos d
streets drawn on plan/profile paper of scales 1 inch to
40 feet horizontally. and 1 inch to 4 feet vertically on
sheets not exceeding 25 inches by 37 inches including
ruled margins and containing the followings
a . Layout of streets in sections coordinated by
stations with the profile .
b . Street plan showing roadways , drainage and partial
lot lines.'
c. Sight line at street intersections .
d . Profile of roadway showing existing and finished
grades , Roadway profile will show all tangent grade
and *all vertical curve information .
e . Profile will show all catch basins and all drainage
lines between catch basins with all invert and top
of frame elevations . Drainage lines will be shown
and described as to material .
f. Typical/critical cross-sections where grading is
outside street right-of-Way or is at 'street
right-of,way.
Where any storm drainage line discharges into an
existing brook) sufficient profile of this brook
will be shown to determine conditions.
h. Metropolitan District Commission datum shall be
used on all subdivisions accessible to controls.
The Town Engineer shall , based on standard
engineering practices , determine the accessibility
of these controls.
AUG 31 '88 17:07 — K.K.C.L.B. - 226 P05/05
i . Profiles shall show all sanitary sewer lines dan
manholes , including elevations , sizes , lengths , and
slopes of pipes . Top of foundation elevations for
houses shall, be shown .
7 . Traffic Re_port
a. en S ace Site zm rovement Plans : For subdivisions
which require a provision for open spates , a plan which
contains data for site improvement may be required .
This map shah, be drawn to a scale of 1 indh equals 20
feet.
9. Sanitary Re ort : Where individual sanitaryy sewage
disposal systems are proposed, the final plans shall
include a Sanitary Report certified by a Professional
Engineer . The report shall demonstrate the feasibility
of the proposed individual systems . The report should
deal with the area as a whole , discussing the following
points ;
a . General nature and development of surrounding area.
b . Topography and natural drainage pattern .
C. Subsurface conditions as shown- by subsurface
investigation , including soil absorption
characteristics , ground water level conditions ,
ledge rock , and general nature of soil .
ram
d . General description of type of development
contemplated - noting type of house , number of
bedrooms per unit , etc.
e. Detailed description of proposed sanitary sewage
disposal facilities, indicating sizes for various
ground conditions , materials to be used , and
general layout pattern to be used, etc .
f . Special precautions that may be necessary to
provide proper functioning of the proposed disposal
systems .
S . Map of general area with locations of all tests
shown on proposed lot layouts.
h . Flood heights of any nearby streams , brooks, or
rivers .
i. Test results and engineering evaluation per Section
All information required above is included in this application at the
time of submission .
911
E', A/ 6 9 z 80
t4 v A 1 DATE
m
ScM"hb 1''c+a 1
KAHAN, KERENSKY, CAPOSSELA, LEVI N E a BRESLAU
ATTORNEYS AT LAW
JURIS CENTRE iI$h kiijj .,or
45 HARTFORD
Box K
TURNPIKE
i(!4j (& Toning COMmISSIOn
SOLOMON KERENSKY VERNON,CONNECTICUT 06066 COUNSEL
JOSEPH P.CAPOSSELA TELEPHONE(203)646-1974JEROMED. LEVINE ROBERT F. KAHAN
WILLIAM E. BRESLAU FAX(203)647-8302
JOEL M. FAIN
MICHAEL A.BARS
WILLIAM J. DAKIN
PETER C. PALMER* September 2, 1988
MAUREEN A.CHMIELECKI••
DAVID B.SOUSA
BRUCE P. FADER
EDWARD C.TAI MAN,JR.
LORRAINE T. PAULHUS
also mass. bar
also ny bar
Planning and Zoning Commission
c/o Ms. Marcia A. Banach
Town of South Windsor
1540 Sullivan Avenue
South Windsor, CT 06074
Re: Subdivision Application - RSK-Kellco
1343 Sullivan Avenue
Dear Ms. Banach:
On behalf of my client, RSK-Kellco, I wish to submit a one-lot sub-
division application. The lot was subdivided more than 32 years ago,
prior to the applicant' s ownership of the property. However, there is
no record that the town acted on the subdivision. As a result, the
applicant has come forward with the application in an effort to ensure
that his property conforms with appropriate subdivision and zoning
regulations.
The property is currently the site of an operating day care center. The
Planning and Zoning Commission approved the special exception and site
plan of development for this activity on May 5, 1987. Additionally, a
building permit and a certificate of occupancy were issued.
Please find enclosed, in addition to the application, a subdivision check-
list signed and dated by a certified engineer and a licensed surveyor,
and a check in the amount of $50. 00 to cover the application fee.
I would appreciate that you schedule the application for the next
available PZC meeting.
If you have any question about the application, please do not hesitate
to call.
Thank you.
spectfully,
Bruce Fa er
BF/sd
Enclosure
c
1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074
e-co AREA CODE 203/644-2511
September 28, 1988
Atty. Bruce Fader
Kahan, Kerensky, Capossela, Levine & Breslau
45 Hartford Turnpike
Box K
Vernon, CT 06066
re: App. #88-83P, RSK-KELLCO Subdivision, 1343 Sullivan Ave.
Child Development Center)
Gentlemen:
We are pleased to advise that the Planning and Zoning
Commission voted at its September 27, 1988 meeting to approve
the captioned application for a 1-lot Subdivision in
accordance with Drawings 1 and 2 of 2 dated 9-1-88, prepared
by Torres Engineering, and with the following modifications:
1 .A drainage assessment fee in the amount of $50 shall be
submitted to this Commission.
2 . Plot plan west boundary must be upgraded to A-2.
3. Direction of sanitary sewer flow must be shown on key
map.
Black and white transparent mylars of Sheet #1 with the above
modifications, together with three blueprint copies of the
entire set of plans, must be submitted to this Commission
within 30 days to be stamped and signed. The letters of
approval of this Commission, as well as the Inland Wetlands
Agency/Conservation Commission, must be reproduced on the
mylars.
After the mylars have been signed by the Commission, they
will be returned to you for filing in the Office of the Town
Atty. Bruce Fader 2- Sept. 28, 1988
Clerk within 90 days . After filing these plans, a copy of
the receipt must be submitted to the Planning Department.
Very truly yours,
PLANNING AND ZONING COMMISSION
Raymond F. Hallowell, Jr.
Chairman
cc: M. Gantick, Director of Public Works
F. Shaw, Supt. of Pollution Control
J. Collins, Chief Building Official
E. Belleville, Assessor
W. Lanning, Fire Marshal
M. Banach, Planning Director
Registrar of Voters
Inland Wetlands Agency/Conservation Commission
IPZC File
Engineer/Architect
Applicant
tow" aE
r T-0 o-Ps d&&4at
4 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074
R•co' AREA CODE 203/644-2511
TO BE PUBLISHED IN THE JOURNAL INQUIRER SATURDAY, Oct. 1, 1988
LEGAL NOTICE
TOWN OF SOUTH WINDSOR
PLANNING AND ZONING COMMISSION
At its Sept. 27, 1988 meeting, the Planning and Zoning Commission
voted to take the following action:
1 . Approve, with modifications, Appl. #88-60P, David W. White,
for a Resubdivision of property to create 3 lots west of
Griffin Road, north of Windsorville Road, and south of Rye
Street, A-20 Zone.
2. Approve, with modifications, Appl. #88-72P, RSK-KELLCO,
Inc. , for a Special Exception to Article 4. 1 .8.c. to
operate a day care center at property at 1559 Sullivan
Avenue, RR Zone.
3 . Approve, with modifications, Appl. #88-83P, RSK-KELLCO,
Inc. , for a 1-lot Subdivision of property at 1343 Sullivan
Ave. , RR Zone.
Dated at South Windsor, Connecticut this 28th day of October, 1988.
PLANNING AND ZONING COMMISSION
Raymond F. Hallowell, Jr. , Chairman
Marshall Montana, Secretary
TOWN OF SOUTH WINDSOR
TOWN HALL
SOUTH WINDSOR.CONN.06074
F
Town TreasurerTO
Town of South Windsor DATE
1540 Sullivan Avenue
South Windsor, Ct. 06074
L J
SUBJECT: Drainage Assessment Fees - Planning and Zoning Commission
FOLD-
Enclosed is a check in the amount of $ t5ro. 00
which is
the drainage assessment fee collected for Application No .
Please deposit it in the proper account . Thank you.
By
PLANNING & ZONING COMMI SION
ByENDORSEMENT THIS CHECK MMEN PAIDISACCEPTEDINFULLPAYMENTOFTHEFOLLOWINGACCOUNT
DATE AMOUNT 10405R.S.K.-KELLCO, INC. U' 31744ELLINGTONROAD
SOUTH WINDSOR,CONN.06074
51-57
2D 119PAY
DOLLARSDATELfUOTHEORDEROF
OTHER I AMTA PAYAFM-U DISCOUNT
i0-i7V r
RICHARD S.KELLEY&CAROLS.KELLEY
i
THE CONNECTICUT BANK AND TRUST COMPANY
AUTHORIZED SIGNATURE
118000 1040 sill 1:0 1 1900 5 7 11: 2 299 59,1' 3