Loading...
HomeMy WebLinkAbout133 Talcott Ridge Roadtactr c#t&sLd APPLICATION FOR BUILDING PERMIT Plumbing# 4v50°1 133 TALCOTT RIDGE ROAD WAC # No 26040 Dat :3yrlQRg Sprinkler# FINAL APPROVA Estimated Cost $ D Ov— Building D 6 ou COMPLETE RED BOXED AREAS Permit Fee Engineering TYPE OR PRINT ONLY Occupancy Fee $ S - Affidavit Em SIGN ON REVERSE SIDE Appr.for CO.Total Fee J 7 3 3 TO BUILD14G DEPARTMENT,TOWN OFSOUTH WNDSOR,CT Additional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location 3 3 lot No. S/ Side of Street_Zone Applicant TeL#/,a o Addr ss ZipAt"Ot Lic.# Owner S 4 rnu Address Architect Address Sq.Ft.N w Area: 1st FI. 115 2nd FI. %4P z 3rd FL Total New Area a 0 Rooms Lavatories Bathrooms Garages Purpos of this permit: ,Q ov m)S9 C Wat* Well El Septic System Sew Ins. H.O. Cert. Area Z Basement 1200 Garage 550 Approved 6y Date 1 Use Group E-4 Construction Type 6 Rw sed 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to:hichr' r'Ied the proper dist a from all street lines,side yard lines,and required distances from all other zones and is located in w b ding is allowed. Signed I hereby apply for a Certificate of Otewi in this application for the permit. Signed DO WRITE 4 OWHIS LINE INSPECTION COMMENTS Location of Job:AFFIDAVIT Additional Fee$ 0— State of Connecticut ss.South Windsor County of Hartford Owner I C 'U l 1_- C /JE-of Aj1,,ept_for the building erected Contractor`- . under Permit No. 26040 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not exceed the submitted estimated cost Signed C Subscribed and sworn to before me this day of A.D.20 00 Estimated Cost$ 167,000.00 Difference: $ otary Public 1 Inspection / Approval Date By Appl Code Description Due Whom Code Comment 99-26040-B 144,000 B01 FOOTING 08/12/99 DCJ A B02 FOUNDATION 08/31/99 DCJ D CAVITY NOT DONE E01 SERVICE 11/18/99 DCJ A RELEASED TO N.U. B03 FRAMING (ROUGH) 11/19/99 DCJ D SPECS FOR LVL, WEB STIFFENERS E03 ROUGH 11/19/99 DCJ A P03 ROUGH 11/19/99 DCJ A H03 ROUGH 11/19/99 DCJ A B04 INSULATION 11/23/99 DCJ D MISSING LVL SPECS. INSULATION NOT COMPLETE B04 INSULATION 11/24/99 DCJ D NO TRUSS INFORMATION PO4 GAS TEST 11/24/99 DCJ A 99-10645-H 9,000 99-10509-P 8,000 99-16561-E 6,000 Total Est Value 167,000 Dwelling 2,662 108,929.04 Basement 1,206 14,954.40 Garage 550 6,820.00 Smoke Det 7 525.00 BOCA Value 148,288.14 Difference 18,711.86) SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 133 TALCOTT RIDGE ROAD LOT_#51 Reviewed By QAI Engineering) CHASE ORCHARDS LLC Date Reviewed 1 Approve Denied 2033 ELLINGTON ROAD,SOUTH WINDSOR,CT_ Reviewed By anning) BP_#_26040_ Ph_# (860) 648-2006 Date Reviewed cN Approve /Denied Date Submitted 05/13/99 FOR C O ***** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan V 3. Site work; i.e. trees, shrubs, dumpsters, required parking V 4. Utility location; a. sanitary sewer/septic system b. foundation drain C. electrical & telephone d. water e. other CGAS 5. Sewer connection charge paid tot(JM 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit No. '70UH Pavement Excavation No. COMMENTS: C7 K- 9- Is o ,ss-v i.- ' 5v+e TTEa T I i F a camas O 1 ED JA N 6 2000 Sow„WNDSORENG.DEFT,t SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTTIICUT 133 TALCOTT RIDGE ROAD LOT_#51 Reviewed By J.?S1ZPA&-eering) CHASE ORCHARDS LLC Date Reviewed pprove Denied l2033ELLINGTONROAD,SOUTH WINDSOR,CT Reviewed B anning) BP #_26040_ Ph # (860) 648-2006 Date Reviewe Approv enied Date Submitted 04/30/99 FORBUILD PE In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, etc. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record C. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: 11 12 9b la MAY 1 3 1999 cc WMWN= ENG.DEPT.AI s iu., DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR v 4SL1 BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# CT JX(_7_644-2511 ext. 230 qeD Date Building Inspector Application must be printed or typed 133 Location of Job: FEE SCHEDULE 0-$1,000=$13.00 Street No. treet Lot No. Over$1,000= 13.00 per$1,000 f Tenant Designationoranyfractionthereof Apt.No. fi APPLICANT cJ G Jr s f APPLICANT ADDRESS cl C APPLICANT PHONE# N 3 OWNER C/4-5 e SSv Cr i S IOFq< OWNER ADDRESS e) 3 f OWNER PHONE y C-) 000 C ESTIMATED COST$ p 0yU- O y IS THIS A CONTRACT COST? 0**Yes 0 No 1 CJ FEE ENCLOSED$ S CIO TYPE OF JOB: SOR CO BNew Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A C$RESIDENTIAL BUILDING PERMIT APPLICATION? ®'YES NO BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS 4- se v NUMBER OF METERS / NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? YES Er NO NUMBER OF LIGHT CIRCUITS `ry NUMBER OF POWER CIRCUITS _ NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURESfo NUMBER OF HEAT CIRCUITS /r NUMBER OF A/C CIRCUITS j SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK J/`' f THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 0 INSPECTOR G DATE I (O TIME LOCATION INSPECTION: CODE: RESULT(D/A) : BUILDING: k t F ELECTRICAL: PLUMBING: HVAC• if OTHER: M r AfW DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR 6 Sop P BUILDING DEPARTMENT 4 APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# r /-(? j X-C" 644-2511 ext. 230 o 4<D Date Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE 133 Talcott Ridge Road Lot#51 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Frank Matlri APPLICANT ADDRESS 29 Bissell Street East Hartfnrcl 06108 APPLICANT PHONE# RhnMilli7RA-951 1 OW N S F OWNER Chase Orchards LLC q F OWNER ADDRESS 2033 El i ngton Road 3 South Windsor, CT 06074 OWNER PHONE 648-2006 C ESTIMATED COST$ 8000.00 U IS THIS A CONTRACT COST? 0 Yes M No FEE ENCLOSED$ 104.00 TYPE OF JOB: S R CO 13 New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YES NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY SINGLE FAMILY DWELLING EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION ORIGINAL SIZE OF MAIN DRAIN 4" NO.OF TOILETS 4 STYLE siphon jet NO.URINALS STYLE NO.OF BATHTUBS 2 NO.OF SHOWERS 1 NO.OF LAVATORIES 5 NO.OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3" AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES 1 KIND whirlpool ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW &YES NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK sewer SIZE OF WATER MAIN 1"SIZE OF WATER PIPING&RISER 3/411& 1/2 " WATER HEATER: TYPE gas MANUFACTURER DESCRIPTION OF WORK Plumbing for gle family dwPI 1 i oq THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 201334 P-1 cT_ CONTRACTORS LICENSE N . TYPE STATE V SIGNATURE OF AP DATE i n ono f i DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WIl TDSOR t>4 BUILDING DEPARTMENT i APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 1 644-2511 ext. 230 t at g Inspector I Application must be printed or typed j it I Location of Job:f FEE SCHEDULE ec 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. f I APPLICANT C, 4/le S I zW V l C APPLICANT ADDRESS 2 i r / 7'd w SA-/d r c- H d rz d G Q APPLICANT PHONE# oZ o — _? ?—l P' o N S OWNER S. c s d G- 0011, O q OWNER ADDRESS CIOD k f- OWNER PHONE i O i 7 y C ESTIMATED COST$_ 1 (i % o U IS THIS A CONTRACT COST? IrYes 0 No i FEE ENCLOSED$ 1 TYPE OF JOB: SOR-CO New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: EATING ARESIDENTIAL KA/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC OrWARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE(°F INSIDE 2 ,..t— OF DIFFERENCE 7.2 OF TOTAL HEAT LOSS(BTUH) L °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)/ZX yU TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY A GASKINPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE 9'0 OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) fo d (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 4ye7/f,2c7x- a TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK ry e 2 THE UNDERSIGNED HEREBY APPLIES FORA PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3dC, lg6) 0 / V,d /- -- CONTRACTORS LICENSE NO. - TYPE STATE SIGNATURE OF APPLICANT z DATE Il 4 J3c 4 "t -5;07 L_ ennox g b j ecti ve Guide to ='ns'tal 1 ati on Comparison LOGIC Software Group Lennox Industries Inc . Dallas , TX 1 -800-527-3506 01 rc lc ***k**sic**** *k* c rc c k******rcyrc* *k rc rc* c**yrc K * c*rc c*c**-cc k c*** rc k**** arc* 1,0/06/96 LOGIC 1000 ,RESIDENTIAL LOADS ANALYSIS PAGE 1 t InGE 1P PREPARED FOR : DORAN PREPARED BY : LARRIE MEYER / C .A. S . PILE TITLE : DORAN2 DESIGN TEMPERATURES (DEGREES F) WINTER INSIDE ' 72 WINTER OUTSIDE 0 SUMMER INSIDE 75 SUMMER OUTSIDE 90 7 DAILY TEMPERATURE RANGE INDICATOR M . DESIGN GRAINS 1;ELATIVE 'HUMIDITY 42 DEGREES NORTH LATITUDE 41 SUMMER AIR CHANGES PER HOUR 1 . 0 WINTER AIR CHANGES PER HOUR 0 . 7 AREA BTUH BTb1H SQ FT LOSS GAIN ROOM - 1 FAMILY ROOM IN ZONE 1 19 X 17 WALL 12j3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 107 385 100 WINDOW 3A DOUBLE PANE CLR GLASS WOOD FRM FACING-N 45 11785 540 TINT-TINTED SHADING-DRAPE HALF DRAWN SHADING COEFFICIENT = 1 WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 136 490 126 OVERHANG . = 1 . 0 FLOOR 19A - HARDWOOD OR VINYL FLOOR + NO INS 289 39246 0 MINTER INFILTRATION 31 CFM 2 ,418 SUMMER INFILTRATION 44 CFM SENSIBLE GAIN 720 LATENT GAIN 11246 L PEOPLE 6 SENSIBLE GAIN 1900 LATENT GAIN 1380 L DUCT LOSS MULT= . 10 6AIN MULT= . 10 832 329, TOTAL -OR ROOM 1 21584 CU FT , r, I ``323 SENSIBLE 9 j:,156 614 LATENT i,n"., its, yz-63• 1"' 1 ,r7(, .'1r,,N' - t.,',`"',ti: - v'„ r,. 'a, is_ n a '',., ' . r% 10/06/96 LOGIC 1000 RESIDENTIAL LOADS ANALYSIS PAGE 7 f WOODBRIDGE LOT $#9 AREA BTUH B,TUH SQ FT LOSS GAIN SHADING COEFFICIENT = 1 WALL 12J3 R- 19 + 1/2 OR 3/4r IN,H EXTR POLY 48 173 45 OVERHANG = 1 . 0 CEILING 16G DARK R-30 INSULATION 143 340 184 WINTER INFILTRATION 20 CFM 11612 SUMMER INFILTRATIOV 29 CFM SENSIBLE GAIN 480 LATENT GAIN 830 L PEOPLE 2 SENSIBLE GAIN 600 0 LATENT GAIN 460 L DUCT LOSS MULT= . 10 GAIN MULT= . 10 352 184 TOTAL FOR ROOM 12 11,144 CO FT 143 SENSIBLE 31876 21021 , LATENT 11290 L ROOM _ 13 BONUS ROOM IN ZONE 3 -11 X 22 r WALL 12i3 R- 19 +.. 1/2 OR 3/4 INCH EXTR POLY 73 263 y68 OVERHANG = 1 . 0 WINDOW 3A DOUBLE PANE CLR GLASS WOOD FRM FACING-S 15 595 23.8 TINT-TINTED SHADING--DRAPES HALF DRAWN SHADING COEFFICIENT = 1 WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 128 461 119 OVERHANG = 1 . 0 WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 128 461 119 OVERHANG = 1 . 0 CEILING 16G DARK R730 INSULATION C 242 575 311 FLOOR 19A HARDWOOD 4R VINYL FLOOR + NO INS 242 21718 0 WINTER INFILTRATION 10 CFM ' 806 SUMMER INFILTRATION 15 CFM SENSIBLE GAIN 240 LATENT GAIN 415 L PEOPLE 4 SENSIBLE GAIN 1200 LATENT GAIN 920 L DUCT LOSS MULT= . 10 GAIN MULT= . 10 588 229 TOTAL FOR ROOM 13 19936 CU FT 242 SENSIBLE 69466 21524 LATENT 1 , 335 L r- i 10/06/96 LOGIC 1000 RESIDENTIAL LOADS ANALYSIS PAGE 6 WOODBRIDGE LOT #9 AREA BTUH BTUH SQ FT LOSS GAIN WINDOW 3A DOUBLE PANE CLR GLASS WOOD FRM. FACING-N 30 1 , 190 360 TINT-TINTED HARING-DRAPES HALF DRAWN SHADING COEFFICIENT = 1 WALL 12i3 R- 19 +, 1/2 OR 3/4 INCH EXTIR POLY 96 346 89 OVERHANG = 1 . 0. CEILING 16G DARK R-30 INSULATION 240 570 309 WINTER INFILTRATION 20 CFM 11612 SUMMER INFILTRATION 29 CFM SENSIBLE GAIN 480 LATENT GAIN 830 L PEOPLE 2 SENSIBLE GAIN 600 LATENT GAIN 460 L DUCT LOSS MULT= : 10 GAIN 'MULT= . 10 419 196 TOTAL FOR ROOM 10 11920 CU FT 240 SENSIBLE 49604 29155 LATENT 11290 L ROOM - 11 B . R . 3 IN ZONE 2 13 X 12 WALL 12.J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 74 266 69 OVERHANGS = 1 . 0 WINDOW 3A DOUBLE PANE CLR GLASS WOOD FRM FACING-S 30 11190 475 TINT-TINTED SHADING-DRAPES HALF DRAWN SHADING COEFFICIENT = 1 CEILING 16G DARK R-30 INSULATION 156 371 201 WINTER INFILTRATION 20 CFM 11612 SUMMER INFILTRATION 29 CFM SENSIBLE GAIN 480 LATENT GAIN 830 L PEOPLE 2 SENSIBLE GAIN 600 LATENT GAIN 460 • L DUCT LOSS MULT= . 10 GAIN MULT= . 10 344 182 TOTAL FOR ROOM 11 1 , 248 CU FT 156 SENSIBLE 39783 21007 LATENT 11290 L ROOM - 12 B . R . 4 IN ZONE 2 11 X 13 WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 58 209 54 OVERHANG = 1 . 0 WINDOW3A DOUBLE PANE CLR GLASS WOOD FRM FACING-S 30 = .,;-1t; y TINT-TINTED SHADING-DRAPES HALF DRAWN 10/0'6/96 LOGIC 1000 RESIDENTIAL LOADS ANALYSIS PAGE 5 WOODBRIDGE LOT #9 AOEA BTUH BTUH SQ, FT LOSS GAIN WINDOW 3A DOUBLE PANE CLR GLASS WOOD FRM FACING—N 45 11785 540 TINT—TINTED SHADING—DRAPES HALF DRAIN SHADING COEFFICIENT = 1 if WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 136 490 126 OVERHANG• = 1 . 0 CEILING 16G DARK R-30 INSULATION 3.06 727 394 WINTER INFILTRATION 31 CFM 21418 SUMMER INFILTRATION 44 CFM SENSIBLE GAIN 720 LATENT GAIN 1 , 246 L PEOPLE 2 SENSIBLE GAIN 600 LATENT GAIN 460 L DUCT LOSS MULT= . 10 ' GAIN MULT= . 10 578 247 TOTAL FOR ROOM 8 29448 CU FT 306 SENSIBLE 61354 21719 LATENT 19706 L ROOM — 9 M . BATH IN ZONE 2 19 X 9 WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 136 490 126 OVERHANG = 1 . 0 TNDOW 3A DOUBLE- PANE CL.R ' GLASS WOOD FRM FACING--N 16 635 192 TINT--TINTED SHADING-DRAPES HALF DRAWN I-IAr)TN- COFF=F71CIENT w 1 Ct=ILING 16G DARK R-30 INSULATION 171 406 220 WINTER INFILTRATION 11 CFM 160 SLIMMER INFILTRATION 16 CFM SFNSIE,I. F GAIN 256 LATENT GAIN 443 L MECHANICAL VENTILATION .675 . 0 CFM 51940 11238 PEOPLE 2 SENSIBLE GAIN 600 LATENT GAIN 460 1. DUCT LOSS MULT= . 10 GAIN MULT= . 10 833 263 TOTAL FOR ROOM 9 11368 CU FT 171 SENSIBLE 91163 2 , 895 LATENT 31045 L ROOM -- 10 B . R . 2 IN ZONE 2 20 X 12 WALL 1-2J3 R- 19 + 1/2 OR 3/4 INCH EXTP POLY 130 12 1a OVERHANG — 1 . 0 10/0'6/96 LOGIC 1000 PESYDEN11AL LOADS ANALYSIS PAGE '4 WOODB:R IDG E L UT #'9 AREA BTUH BTUH Q, FT LOSS i GAIN TOTAL FOR ROOM 5 1 , 260 CCU, FT 1610 SENSIBLE 31142 21970 LATENT 11346 L ROOM - 6 DEN IN ZONE •1 11 X 13 WALL 12J3 R-- 19 + 1/2 OR 3/4 INCH EXTR POLY 58 209 54 OVERHANG w 1 . 0 WINDOW 3A DOUBLE PANE CLR GLASS WOOD FRM FACING-S 30 19190 475 TINT-TINTED SHADING-DRAPES HALF DRAWN SHADING COEFFICIENT = 1 FLOOR 19A HARDWOOD OR VINYL FLOOR + NO INS 143 11606 0 WINTER INFILTRATION 20 CFM 11612 SUMMER INFILTRATION 29 CFM SENSIBLE GAIN 480 LATENT GAIN 830 L PEOPLE 4 SENSIBLE GAIN 1200 t'ATE NT GAIN 920 L APPLIANCES 1200 DUCT LOSS MULT= . 10 GAIN MULT= . 10 462 341 TOTAL FOR ROOM E 11144 CU FT 143 SENSIBLE 51079 31750 LATENT 11750 L ROOM -- 7 BATH IN ZONE 1 7 X 8 FLOOR 19A HARDWOOD ' OR VINYL FLOOR + NO INS 56 629 0 WINTER INFILTRATION 0 CFM 0 SUMMER INFILTRATION 0 CFM SENSIBLE GAIN 0 LATENT GAIN 0. L PEOPLE 1 SENSIBLE GAIN 300 LATENT GAIN 230 L DUCT LOSS MULT= . 10 GAIN MULT= . 10 63 30 TOTAL FOR ROOM 7 448 CU FT 56 SENSIBLE 692 330 LATENT 230 L • ROOM - 8 M .B . R . IN ZONE 2 r. 18 'tX 17 i R WALL-,1,2J3 R-- 119 + 1/2 OR 3/4 INCH E.XTT .R P'0LY 9 9 '','.'k`M4 r«r, . RH G 1, o y<< _. r .' `, ,, .. 3 L•, r nfir. 10/06/96 LOGIC 11000-RESID-E47"I'AL 'LOADS ANALYSIS PAGE `3 WOODBRIDGE LOT #9 AREA BTUH BTL!H Ss FT LOSS, GAIN TOTAL FOR ROOM 3 1 , 560, CU FT 195 SENSIBLE 51074 41065 LATENT 11878 L ROOM - 4 LIVING ROOM *IN ZONE 1 14 X 13 WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 82 295 76 OVERHANG = 1 . 0 WTNQQW 3A DOUBLE PANE CLR GLASS WOOD FRM FACING-S 30 11190 475 TINT-TINTED SHADING--DRAPES HALF DRAWN SHADING COEFFICIENT = 1 WALL 12,13 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 120 432 112 OVERHANG = 1 ..0 FLOOR 19A HARDWOOD OR VINYL. FLOOR + NO INS 182 21044 0 WINTER INFILTRATION 20 CFM 11612 31JMME:R INFILTRATION 29 CFM SENSIBLE GAIN 480 LATENT GAIN 830 L PEOPLE 6 SENSIBLE GAIN 1800 LATENT- GAIN 1380 L APPLIANCES 1200 DUCT LOSS MULT= . 10 GAIN MULT= . 10 557 414 TOTAL FOR ROOM 4 1 ,456 CU FT 182 SENSIBLE 6 , 131 41557 LATENT 21210 L ROOM - 5 FOYER IN ZONE 1 8 X 20 WALL 12J3 Rw- 19 + 1/2 OR 3/4 INCH EXTR POLY 115 J OVERHANG ', = 1 . 0 WINDOW 3A DOI BLE PANE CLR GLASS WOOD FRM FACING-S 14 5.55 238 TINT-TINTED SHADING-DRAPE`: HALF DRAWN SHADING COEFFICIENT = 1 DOOR 10H PANEL & MOOD STORM 1s 467 121 WINTER INFILTRATION 22 CFM 13719 SUMMER INFILTRATION 31 CFM SENSIBLE GAIN 512 LATENT GAIN 886 L PEOPLE 2 SENSIBLE GAIN 600 ' LATENT' GAIN 460 L APPLIANCES 00 DUCT LOSS MULT= . 1 0. GAIN MULT= . 10 270., 6 10/06/96 LOGIC 1000 RESIDENTIAL LOADS ANALYSIS PAGE 2 WOODBRIDGE, LOT #9 AREA BTUH BTUH SO FT LOSS A GAIN ROOM - 2 KITCHEN IN ZONE 1 P 26 X 13 MALL 12i3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 163 587 152 OVERHANG = 1 . 0 DOOR 80' `SLDNf I DR', 2 PN CLR GLASS METAL FACING-N' 36 1 , 879 396 TINT--TINTED SHADING-DRAPES OR BLINDS SHADING, COEFFICIENT = 1 WINDOW 3A DOUBLE PANE CLR GLASS WOOD FRM FACING-N 9 357: 108 TINT-TINTED SHADING-DRAPES HALF -DRA1A!N SHADING COEFFICIENT = 1 REVEAL = 11. 0 FLOOR 19A HARDWOOD OR VINYL FLOOR + NO INS 338 3 , 796 0 WINTER' INFILTRATION 31 CFM 21418 SUMMER INFILTRATION 44 CFM SENSIBLE GAIN 720 LATENT GAIN 11246 L MECHANICAL VENTILATION 50 . 0 CFM 39960 825 PEOPLE 6 SENSIBLE GAIN 1800 LyATENT GAIN 1380 L APPLIANCES 1200 DUCT LOSS MULT= . 1 0 GAIN MULT= . 1 0 1 , 300 520 TOTAL FOR ROOM 2 21704 CU FT 338 8'ENSIBLE 141`297 51720 LATENT 41054 L ROOM - 3 DINING ROOM IN ZONE 1 13 X 15 WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 86 310 80 OVERHANG = 1 . 6 WINDOW 3A DOUBLE PANE CLR GLASS WOOD FRM FACING-N 18 714 216 TINT-TINTED SHADING-DRAPES HALF DRAWN SHADING COEFFICIENT = 1 WALL 12J3 R- 19 + 1/2 OR 3/4 INCH EXTR POLY 120 432 112 OVERHANG = 1 . 0 FLOOR 19A HARDWOOD OR VINYL FLOOR + NO INS 195 2 , 190 0 WINTER INFILTRATION 12 CFM 967 SUMMER INFILTR-4TION 17 CFM SENSIBLE GAIN 288 LATENT GAIN 498 L PEOPLE 6 SENSIBLE GAIN 1800 • LATENT GAIN 1380 L A-PPI._IANCES 12 0 0, C,UCT LOSS MOLT= . 10 GAIN MULT= . 1 0 * ' 1 ~ i° 31 0,11" a i ^-•) 'H --+'•'.. . "^Z -t' tom' 1 4 10/06/96 LOGIC 1000 RESIDENTIAL LOADS ANALYSIS RAGE 8 WOODBRIDGE LOT #9 STRUCTURE TOTALS 21 , 240 CU FT 21655 SENSIBLE 77 , 818 39 , 328 LATENT 24 , 050 L w-_________.._____..-.._-___-__..____ MINIMUM Cooling Capacity needed is 63 , 3,79 btu at 90 degrees outside and 75 degrees inside Maximum Desired Cooling Capacity is 72 , 885 btu 1 1 5% of Total Load) w___-_________-..----______w_..__.._________________ Version 92 . 12 This Heating and Cooling Load Computation was produced using the procedures * and tables of the Air Conditioning Contractors of America ' s Manual J , * Seventh Edition , The accuracy of the calculated loads ' depends upon the * accuracy of the data used and the acc racy of the Manual J load calculation * procedures. for, the given conditions . No warranty , either expressed or: i mp1 i rwd , is given by Lennox Ind-ustri es Inc . with respect to the accuracy * and/or, sufficiency of the information provided by this report .