HomeMy WebLinkAbout130 Berle Road (12)FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: // /O , NO. TOWN OF SOUTH WINDSOR EST.COST: o;Zg0o, 00 BLDG. PERMIT NO. IN r7 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING p gel-le /c7/ thereof - $10.00 OWNER ADDRESS TOWN PHONE NO. HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL X A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT_LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC V WA AIRR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION INSIDE OUTSIDE CAPACITY/yoo LPG TANK - CAPACITY EXISTING RADIATION/ao oan ADDITIONAL RADIATION O TOTAL RADIATION/oo,cao DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT LOSS (BTUH) Is HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO. : Zwell o;960 nQs ois o /c/ /1 ei I/n GQ.. !r1l L P/D /7 rl Firm G!/Q 'r fr, GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 04Gi 1/ass nos-?/- Iral 60 o a :/e-e STATE LICENSE - NAME & TYPE #DATE SIGNATURE OF APPLICPAqT flol i.Op- D DATE I - B - R CALCULATION SHEET 1503 (Modern Method)Copyright 1971 by The Hydionlcs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL A COL.6 COL.C COL.D COL.E COL.F COL.G I ROOM O H L W H L W H L W H L W H L W Oeslgn Wstar Temp- 2 ROOM DIMENSIONS, FT. u sruH per F t of 3 L_ENGTH EXPOSED WALLS,FT.Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL STUN BTUH STUN STUN STUN 5 WALL CONSTRUCTION ROOM LIN.FT.OF Table 9, Line 3 x H) TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED IBottom of table used for Line 5) 7 CEILING CONSTRUCTION C Table 9, L a W) g FLOOR CONSTRUCTION( D Table 9, L x W r Lin. F t) E 9 COLD PARTITION CONSTRUCTION F Table 9,L a H)G 10 c 1 Well 1W Ith Openings) H c Z_: 2 Walls(With Openings) e Xa 6 3 Wells I W ith Openings)or Ent.Hall t 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL.A COLS COL.H COL.1 COL.J COL.K COL.L. TOTAL BTUH TOTAL OF SUILOING RADIATION 1 AOOM E AT SELECTED O H L W' H L W H L W H L W H L W DESIGN TEMP.* 2 ROOM DIMENSIONS.FT DIFFERENCE U 3 LENGTH EXPOSED WALLS. FT d WINDOW AND OUTSIDE DOOR AREA LL BTUH STUN BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9,Line 3 x HI TOTAL 20% 6 TYPE OF GLASS IBottom f table used lot Line 51 CONSTRUCTION tFOR CONCRETE FLOOR ON 7 CEILING CON GROUND OR FILL AT Table 9, L x GRADE LEVEL,USE LINEAR g FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9. L x W or Lin F t) 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 c 1 Well(With Openings)C 2 Walls lWith Openings) a x 3 Wells(With Openings) or Ent Hall J 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form Is eveilebie If m The Hydronlcs Institute 35 Russo Piece,Berkeley Heights,N J 01922