Loading...
HomeMy WebLinkAbout128 Birch Hill Drive (5)PERMIT # Application For d DEPARTMENT DECISION 3060 2838HeatingPermit 3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS LOt r,APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR o p 8- 00 0) DATE CHIEF HIS R APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW 1. LOCATION OF JOBO o 11-4 4J 6—,z 0 NO. STREET c v cn LOT NO. FLOOR APT. NO. O N C 2. OWNER cd 0 3. ADDRESS f 4.PHONE cd S. APPLICANT d. ADDRESScdr-C s6 7.PHONE 12?%4 IS a S. LICENSE NO.r p, 9. EXPIRATION DATE OF LICENSE (r c.> 10. ESTIMATED COST s o T" t 1. IS THIS A CONTRACT COSTT YES NObV Permit #494812. FEE ENCLOSED S v t 3. TYPE OF DING: bq RESIDENTIAL COMMERCIAL O INDUSTRIALCIS14. TYPE OF JO GI IN ADDETIONON REPAIR T T IT Continued fr m Reverse SideAPPLICATIONFORHEATINGPERMc f0if,1. LOCATION OF JOB Lot #21 Birch Hill Rd, lst & 2nd NO. STREET FLOOR APT.NO. 12. TYPE OF INSTALLATION: OIL BURNER 91 HEATING SYSTEM VENTILATION SPRINKLER GAS BURNER STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE SIZESIZE 13. OF TANK 275 OFCTANKN cellar OF FILL 2" OF VENT la" 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE 1.7 BOILER OR FURNACE MAKE AND NO. 129,000 B.T.U. OR SQ. FT. NET 860 B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED lSt & 2nd NEW OR OLD BUILDING new INSULATED - YES OR NO Yes TYPE OF WALL frame INSULATION 211 ROOF OR CEILING 2" -INSULATION fiberglass AVG. SYSTEM WATER TEMP. 1800 B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 0 - 700 FAHRENHEIT MAKE OF RADIATION: BASEBOARD, COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U.Federal baseboard Model QC 8" 610 BTU - 1800 DESCRIPTION OF WORK Forced hot water, with baseboard, American Standard 15. TO BE DONE: 2 zones. 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS: ROOM SIZE WINDOWS AREA - SQUARE FEET B.T.U. B.T.U. EO<DISTRIBUTION INSTALLED AND DOORS VOLUME TOTAL TOTAL yl ROOM NO.GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70°F CORRECTED J j LL LL REGISTER L W H AND TEMP. TO I<-I..: TYPE AND SIZE RAD' OR LEADERcc SIZE < WALL IF I', INFILT.) DIFF. F O N SQ. FT. FREE AREA l. I .10 2' 16b . 10 Ol ed 5 0 7 22 5600 10' Lineal t 2- 227ed51734 00 2 6800 12 ' ed3 3 1 76 4 8 6300 lo, 4 6 165 22 143 120 90 r r rl 6 b4 35 26 ath 5 7 7 6 1920 iv. 4 8 76 68 40 1060 17it i-rr-& 2 4 76 60 70 2 2 1110 19' en 6 2 7 40 604 1 600 1051 aun 5 7 7 x 120 2 ' a 35 th 5 7 7 216 4' ' TOTALS 56486 T- 951 A. HEAT LOSS FROM BUILDING 56 ,480 B.T.U./HR. B. DOMESTIC HOT WATER DEMAND 22 ,500 B.T.U./HR. C. PIPING, OTHER THAN NORMAL 20,000 B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND 18. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. :2 __2--LI DATE 7 SIGNAT E OF APPLICANT