Loading...
HomeMy WebLinkAbout125 Cody CircleFINAL INSPECTIO S-14 tjuilding APPLICATION FOR BUILDING PERMIT Plumbing t HVAC DateSe tembpr 2g , 1004 Sprinkler 1 25 CODY CIRCLE Electric Estimated Cost $ 7 0, 0 0 0. 0 0 Zoning Permit Fee $7 0 0_ n o Affidavit NO. 21841 Occupancy Fee $ 3 . 00 Eng. Dept. z Fire D pt.COMPLETE RED BOXED AREAS.Total Fee $703 . 00 Health Dept. TYPE OR PRINT ONLY Approved for CO `r SIGN ON REVERSE SIDE. Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Locatio 2 5 Cody Cr S o.Windsor CT , 06074 Lot No. 4 Side of Street L ZoneA-20 Applicant Clark Realty Inc Tel. #644-81 37 Address 658 Ellington Rd So.Windsor Ct Zip 06074 Lic.# 500326 STREET CITY STATE Owner J .M.J . CONST. CO . INC Address SAME Architect DAVE GOSSELYN Address SAME Size New Area: Ft. Front Overal I Ft. Deep Overall,rSCA Total Area 2, 0 0 0 Garages 2 Lavatories 1SizeofLot22 , 492 Dist. from Street Line 5 0 Bathrooms_2 Rooms 1st 4 2nd 4 3rd Purpose of this Permit Construction of a single family residential dwelling City Water 11 Well Septic Sewer C Use Group Co struction Type `S Approved by Date BD1A 11/88 I her by agree to conform to all th requirem nts of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed Clark Realty Inc B I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed Clark Realty Inc By : DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# 5ZA Inspections: HVAC Permit# ` Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: Location djab AF+MAM Additional Fee., $2 5 0:.0.0 State ofCannecd=t County ofHartford of R.2:;Ii. A for budding erected under n 41PermitNo, ..• 218.................... issued by the Dep't of Budding of the lbwn of South Windsor being duly sworn.make oath and say that the actual cost of the completed work authorized under said permit did not exceed the most current actepted BCCA value of . . .$10.2'6 5.5...0 0.. . . . . . . . . . Signed ---. Subscribed and sworn to before me this day o . .-.-- - A.D.19 Estimate Cost:S 78, 500. 00 24, 155. 00 Difference: S ucli. Inspection / Approval Date By Appl Code Description Due Whom Code Comment 94-21841-B 70,000 P02 UNDERGROUND 10/24/94 JFH A WATER TEST P02 UNDERGROUND 10/28/94 JFH D NO WATER EO1 SERVICE 11/03/94 JFH A RELEAASE ISSUED B03 FRAMING (ROUGH) 11/07/94 JFH A P03 ROUGH 11/07/94 JFH A E03 ROUGH 11/07/94 JFH A B04 INSULATION 11/07/94 JFH D NO INSULATION AT CONNECTING WALLS B04 INSULATION 11/07/94 JFH A REINSPECTION PO4 GAS TEST 11/30/94 JFH D NOT READY PO4 GAS TEST 11/30/94 JFH A AIR TEST 94-9502-P 3,000 94-9053-H 3 ,000 94- 13244-E 2 ,500 Total Est Value 78,500 Dwelling 2,000 74,360.00 Basement 1 ,040 10,348.00 Garage 484 5,687 .00 Smoke Det 6 450.00 BOCA Value 102,654.85 Difference 24 , 154.85 /U_.'Q L f SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 125 CODY CIRCLE LOT_# Reviewed ByzAJ 'r'7 Engineering) CLARK REALTY, INC. Date Revie a jZ- 12-9+- Approved/Denied 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By anning) BP # 21841 Ph_#_( 203 )528-6054 Date Reviewed t Approve Denied Date Submitted 09/30/94 FO C of 0 I *wwww As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Appr ed Denied N/A 1 . Approved building permit plan 2 . Finish grading per approved building permit plan 3 . Site work; i .e. trees, shrubs, dumpsters, required parking 4 . Utility location; a. sanitary sewer/s m b. foundation drain C. electrical & telephone d. water e. other 5 . Sewer connection charge paid 6 . Appropriate certification 7 . Bonding 8 . Planning & Zoning/ Inland Wetlands Considerations 0 Q• K• L••Q • :5 IZ'12f Sewer Permit No. 2- 04 Pavement Excavation No. COMMENTS: S P0V W'STH -3 aAN 1 v+Prr • O Aa-XI SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 25 CODY CIRCLE LOT_# Reviewed By i Engineerin CLARK REALTY, INC. Date Reviewed Approve 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By Pl BP # 21841 Ph # ( 203 )528-6054 Date Reviewed o Approved/Denied Date Submitted 09/30/94 FOR BUILDI E IT ***** In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval . The minimum requirements shall include: A o ed Denied N/A 1 . Name, address & phone number of owner/ applicantLvi i 2 . Name, address & phone number of plan preparer 3 . Zoning Information - i .e. zone, open space, floodway, etc . 4 . Plot Plan at 1 " = 40 ' scale a . Subdivision reference, abutting properties , etc. b. Easements of record C . Lot description, bearings, building lines, distances , area, etc . d . Contours, existing & proposed, 1 or 2 ft . interval where appropriate e. Building location with dimensions . Elevations of proposed finis or e floor & centerline of road a f . Elevations of gravity drainage systems, sanitary f oun a ion ra at the house andouseand the see g. Tentative utility location (gas, water, electric, septic system, etc . ) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements . (P . E. & L.S . ) 5 . Sedimentation and erosion control 6 . Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: Now 1 1j9c—sq SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 125 CODY CIRCLE LOT_# Reviewed By Engineerin CLARK REALTY, INC. Date Reviewe "wjApprove 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By Pl BP # 21841 Ph_# ( 203 )528-6054 Date Reviewed o Approved/Denied Date Submitted 09/30/94 FOR BUITDIXG PERMIT ***** In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval . The minimum requirements shall include: A o ed Denied N/A 1 . Name, address & phone number of owner/applicant 2 . Name, address & phone number of plan preparer 3 . Zoning Information - i .e. zone, open space, floodway, etc . 4 . Plot Plan at 1" = 40 , scale a. Subdivision reference, abutting properties , etc. b. Easements of record C . Lot description, bearings, building lines, distances , area, etc . d. Contours, existing & proposed, 1 or 2 ft . interval where appropriate e . Building location with dimensions . Elevations of proposed finish floor, garage floor & centerline of road at driveway -w f . Elevations of gravity drainage system s,sanitary f oun a ion r at hoC r d ' Sum p g. Tentative utility location (gas, water, electric, septic system, etc . ) At h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements . (P. E. & L.S . ) 5 . Sedimentation and erosion control 6 . Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: 9NS rVlf1'1C v- 7 eptember J. 1990 Capuano Deve1opers 1275 Cromwell Avenue Rocky Hill , Ct 06067 RE: ZBA Application #1587-90 - West side of Beldon Rd . ulnl / ear nr . L apuano: c, At the 'oee ng oI the Zoninq Board o held on September - , 199o, a variance was granted o Section 5. 1s of the Zon ng Regu1ation o allow the s. f . of "bui] dable area" o he located in regulated wetlands on on tne wes side of eldon Ho ad . ( 2"-20 Zone ) The Bo-Lrd no ed t--hat thiH prope/ ty is un que becMIu the "wst) ,''' on th s e re m n-made sws) e lt was lso noted ihat t/` r.er drainage s/stsm proposed w 1l mprove ar/d pre/ert w te/' p/ ob emc tnat urroond ng ne gh ors are presently dea] in th from the surfsce run off from this prope/-tv. Ths Board d d no feel e water table in r/eighboring wells would not be affertc'd . This action is effective upon your filing of the enclosed form in the Town Clerk ' s office at your own expense. ery trulv yoors , Pobert Wsr/'en Cha1rman Zoning Board of Appea1s RW:d1b Enclosure CC: Peter DeMallie, Design Professionals PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE 644-2511 Ext . 230 at B 1 ng Inspector Application must be printed or typed 1 . LOCATION OF JOBo ' dQ FEE SCHEDULE No . Street 0 — $19000 — 10.00 Floor Apt . No. Over $1,000 — 10.00 per $1 ,000 or 2 . OWNER fraction thereof V//3. ADDRESS 4, APPLICANT 5. ADDRESS )0 z2zV / fir T 6, ESTIMATED COST $ cvc 7 . IS THIS A CONTRACT COST Y N 8. FEE ENCLOSED $ 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB : riginal Installation Alteration/Addition/Repair Rn 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOBZ.0/- I--- NO. STREET APT. NO , 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER 14 . NO . OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16 . NO . OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 6,-?3 18 . NO . OF HEAT CIRCUITS 19 . NO. OF POWER OUTLETS 1/20 . NO. OF CONVENIENCE OUTLETS `7 21. NO. OF HEAT CIRCUITS_ 22 . NO. OF POWER CIRCUITS 6' 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS_ZL!!! 25 . NO. OF MOTORS 26 . NO . OF PANELS_ 27 . TOTAL WATTAGE // 28 . NO . OF POWER FEEDERS L 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32 . NO . OF FIXTURES 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : LICENSE NO.SIGNATURE OF APPLICANT DATE PHONE NUMBER: L L INSPECTOR DATE l TIME LOCATION INSPECTION: E: RESULT(D/A) : 14 BUILDING: L X` P ELECTRICAL: pot- 10, k PLUMBING: HVAC: OTHER: PERMIT NO. q5D DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is hereby :TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT.APPROVE DISAPPROVED 1540 SULLIVAN AVENUE 41 4 644-2511 Ext. 230 a e Building Inspector Applications must be printed or typed 1. LOCATION OF JOB: F E E SCHEDULE 2. OWNER: ` 0 - $1 000 - 10.00 3. ADDRESS: tS 01 Over $1 ,000 - 10.00 per $1 ,000 or 4. APPLICANT: zq'fraction thereof 5. ADDRESS: 6. EST. COST: $ --'-VD® 7. IS THIS A CONTRACT COST? YES 0 8. FEE ENCLOSED: $ 9. TYPE OF BUILDING: RESIDENTIAL COMMER AL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS t_ _STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS D` 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL- 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER R SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE ?L' 'S / G'y s 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE c ems.35. CAPACITY t 39. RELIEF VALVE 36. TEST PRESSURE l y LBS. 40. MANUFACTURER 37. WORKING PRESSURE Ze LBS. 41. PRESSURE RELIEF VALVE 38. TYPE d' le ,a }o` 42. MANUFACTURER J LICENSE NO. D E SI A RE OF PLICANT PHONE NO. r OR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: /O 5 v NO. TOWN OF SOUTH WINDSOR EST.COS BLDC. PERMIT NO. f 1540 SULLIVAN AVENUE FEE C50100 SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fractions thereof - $10.00LOCATIONOFBUILDING OWNER ADDRESS TOWN PHONE NO. 7:?50 a HVAC CONTRAC ADDRESS TOWN PHONE N0. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT_LBS. HIGH PRESSURE LIMIT_LBS. HYDRONIC WARM AIR UNIT RADIAN HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM_ GAS IN-PUT/OOXO ELECTRIC KW WOOD COAL OIL TANK - SIZE b LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION_ ADDITIONAL RADIATION TOTAL RADIATION_ DESIGN TEMP. OUTS E_OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) Is SEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE A MODEL GROSS HEATING CAPACITY (INPUT-BTUH) GV NET RATING (OUTPUT-BTUH)-4ve00Of IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: JOAMS z 7 v kbk 5 OCV STATE LICENSE - NAME 6 TYPE # DATE TURE OF APIL T APPROVED DATE BD 4A 11/88 I - B- R CALCULATION SHEET 1503 (Modern Method)Copyright 1971 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COLS COL.C COL.D COL.E COL.F COL.G 1 ROOM ti O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.1-U OTUH pm Po t f 3 LENGTH EXPOSED WALLS,FT. Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA to BTU" STUN STUN STUN STUN 5 WALL CONSTRUCTION e 9,Line 3 x H) ROOM LIN. FT.OF Tabl TOTALS RADIATION 8 TYPE OF GLASS FROM LINE 12 SELECTED IB ttorrt f table used for Line 5) 7 CEILING CONSTRUCTION C Table 9. L x W) g FLOOR CONSTRUCTIONt Table 9. L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION t< Table 9. L x HI G 10 -C 1 Wall(With Openings)O c; 2 Wells(With Openings) x 1li 3 Wells IWith Openinga)or Ent.Hall J 11 TOTAL RTUH AT 7OF TEMP DIFFERENCE' 12 TOTAL RTUH AT DESIGN TEMP. DIFFERENCE K COL.A - ^-- -_— COLS COL.H COL.I COL_J COL.K COL.L TOTAL STUH TOTAL 1 ROOM OF BUILDING RADIATION Q AT SELECTED O H L W H I L W H 1 L I W N I L I W H L W DESIGN TEMP.- 2 ROOM DIMENSIONS,FT DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT. d WINDOW AND OUTSIDE DOOR AREA U. STUN TUN STUN BTUH RTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, Line 3 x HI TOTAL 20% a TYPE OF GLASS Is itit m f table used f r Line 51 tFOA CONCRETE FLOOR ON7CEILINGCONSTRUCTIONGROUNDORFILLAT Table 9. L x W)GRADE LEVEL,USE LINEAR S FLOOR CONSTRUCTION11 FEET OF EXPOSED EDGE: I T able 9.L x W or Lin Ft.) 9 COLD PARTITION CONSTRUCTION ITable 9.L x H) 10 c I Well(With Openings)C 2 Wells{With Openings) G X 3 Wells(With Openings)or Ent. Hall J 11 TOTAL RTUH AT 70F TEMP DIFFERENCE' 12 TOTAL RTUH AT DESIGN TEMP DIFFERENCE FORM 1501 This I rm Is evatlebie fr m The Hyde nice Institute 35 Russo Place,Berkeley Heights,N J 01922 19 ru IN me [ Ku ILU 1-4 Me OEM Now g wAf 6,tWNW* wro"A rcygm mon0 1M,&* , if%0 PrAjOid m lion will MOPIrAt xym M19"'WAII MEN= I+`,`.:7'dJ a It ILT W.i'iy'//lrT if t[ fi1 I , cTi., R'di1 r gill y LEGEND o IRON PIN TO BE SET O MONUMENT TO BE SET 300 EXISTING CONTOUR x 287.3 EXISTING SPOT GRADE w—w— WATER MAIN G—G— GAS MAIN NOTE I. S&CMRY 31- H WMT ft"Ana%1 T*qN PROM N5PEGTION REPORT PROV W DY Tt'e CONTRACTOR 1, ALL 07%49 WIGTM ON"PLAN HAVE IN VERJr1W 0 0 1+ 0 INTM 18 X.D AS TO LATIAN, tirVAnON MID rL 44 BAKER L E vr 7 A ri'Yr Ri23'4717 W O o 127.55' 0 90'00'00"d R $ 25.0 ' t L 3 7' A J 1" wu. Iav n J N r7 cpI 8.7 e°8°9 f p O L = 51*1 4 O R = 25.00' o,' s"a O 25' WIDE DRAINAGE EASEMENT IN FAVOR OF THE L' x TOWN OF SOUTH WINDSOR B•9 4 NOM- A = 47'4 0" DOUNPIWY NPORMATION TAKENM15PROMPL 5 0' 22,492 f 0.51 owcres Bmnj!D "1'OmRAPI'tIG PLAN-N ROAa 9.vPNiww, *tmT5 4 AL 1g ji STHIRD7OPV, SCALP I"4O', L.A6T REVI ION II/!Z/h. PREFAB® FOR Jb{J CONSTRUCTION 64WA Y, DY PESIGN P90rI!-46 NAL5, NG. N 2006' 1" E S 122.90' THIS MAP AND SURVEY WERE PREPARED IN ACCORDANCE TO A-2 STANDARDS OF HORIZONTAL ACCURACY AS DEFINED IN THE RECOMMENDED STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT' PREPARED AND ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC., SEPTEMBER 24, 1992 TO THE BEST OF MY KNOWLEDGE AND BELIEF THIS MAP IS SUBSNTIALL BOR S NO HEREON.TA i 12882 RICHARD P. MARTEL LIC. No. GRAPHIC SCALE BIEIL DON IES'ICL4 TIES sHEET1.uMFss olHoer E wolD.E1041U10 umm REVISIONS 203 291-8755 L ARE., Igo IL® ® 4 1 AVA c NFOIIYAIIgL ALL E70SV10 UlW71E8 t•9 v 3r ee"/d.t_ 40 p 20 40 PLAN MOU" BY A„U_ YOR PRIOR CONSIRUCTM rof lonsl , Inc.2 ALL U7LJ1E3 ARE TO!E STAND N NE FElD O 000 y C'ieeL•L m4w 8r.,tom rar snss- c MAUD UM.ES5 R BEARS 1F civil n Inesrs • tanners • aurySMESsSEALANDOWMA31WA7URE1inch = 40 feet 9 P rom OF 7NE PRCPlSISIONAL DMEM/gAMEfOR. NO. DATE DESMP710H BY u.S A s•rs. ,•.za 9 uth winesor, connecticut 060741 SOUTH WINDSOR CONNECTICUT aAE w er9fAr o 2•Q 9 h y R 3 — - ir Dic C, 9 Im oath `inc',Sor GU(LD} G DEPARTMIEN T Ti. coo, .e propofeif r erected gt wed ,-th C' 1,3olld: , ,inc, t t d-C tK !' f, .f of this appl-1-t._.1) , permit. S+gned lhis pf„n i apf - cfdcrs anCl rid" P!j,ud v itl Conditionally Building lnspedta: yr 2113 q 3 T©V!!N OF : IF ti DEC 9 1994 c, SOM tti r sscr' f DEn V 6