HomeMy WebLinkAbout125 Bidwell Road (11)PDSEngineering & Construction, Inc. 107 Old Windsor Road, Bloomfield,Conn.06002
Phone: (203)242-8586 Fax: (203)242-8587
November 7, 1994
GIRUCT ONSTUCTI
Town of South Windsor
1540 Sullivan Avenue NOV U f 1994SouthWindsor, CT 06074
ATTN: John Collins; Building Official South Windsor
RE: EAST COAST STAIR; BIDWELL ROAD 13UILDING DEPARTMENT
Dear Mr. Collins
As per our phone conversation of November 4, 941 I would like
to clarify the showroom wall- detail on the East Coast Stair
building. The wall is framed with 3 5/8" 18 gauge studs 1611 on
center. These studs have an allowable unbraced height of 19'-111.
Our design is conservative, as our ceiling height is 18'-4" and we
are bracing the back side of the wall at the 16' height by putting
diagonal bracing at 4' on center.
Should you_ have any questions or comments, please do not
hesitate to call.
Very Truly Yours
Frank C. Borawski, R.E.
Vice President
PDS Engineering & Construction, Inc.
FCB/ab