Loading...
HomeMy WebLinkAbout123 Greenwood DriveR FINAL INSPET S• Building APPLICATION FOR BUILDING PERMIT Plumbing U HVAC lor ao , Date: SprinklerQF Electric Estimated Cost $ f` %2 1 b a • Zoning 17649 Permit Fee $ Affidavit NO.Occupancy Fee $ 3.e e Eng. Dept. ' ^' COMPLETE RED BOXED AREAS. 41 Fire Dept TYPE OR PRINT ONLY Total Fee Health Dept. Approved for CO: SIGN ON REVERSE SIDE. TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location ri1. ; ` Lot No. A V Side of Street Zone Applicant Lc_x !=Q A C Tel. # L G C•Z 8?a Address ` S^ L 0 u .'s S r 11/ieu., e G?niv COMA, Zip el 46 10 Lic.# Owner A AS AE Address S oft Ar Architect 4-4D .A-2 T sews Address 1'2 8 tfisAr.+*An l ip %e.`A.vn Ce va Size New Area: Ft. Front Overall '?G`Y'Ft. Deep Overall 3 G' B '—Total Area 3 f `? S #Garages Lavatories No. of Families No. of Stories 7_Construction y ka-h_Bathrooms Rooms 1st 2nd& 3rd Size of Lot Dist. from Street Line d Dist. from Side Street Line Purpose of this Permit 06;r Qr 4 City Water Z' Well Septic Sewer 4R"'a Approved by Date s BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed b 1 hereby apply for a Certificate of Occupancy for the work described in this application for ermit. Signed DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD tv& Footin Foundation S-ZS-Insulati_Z, 4 Plumbing Permit# Inspections: HVAC Permit# 7& U Inspections: Electrical Permit#TCf t 40— Inspections. t -- Sprinkler Permit# Inspections: BUILDING INSPECTION DEPARTMENT SOUTH WINDSOR, CONNECTICUT FEE PAID: $3.00 CERTIFICATE OF OCCUPANCY ZONE: DATED 9 2 9 19 89 This is to certify that 123 Greenwood Drive EreAted under permit No. 17649 conforms substantially to the requirements of the building ordinances and the zoning regulations of the Town of South Windsor and is hereby approved for occupancy as indicated below. Approved for Occupancy— Single family dwelling -- Lot #20 Budding Official Notice:If this certificate is lost or destroyed, a duplicate should be obtained immediately from the Building Department. Any change or extension of the use herein approved requires a new certificate of occupancy. CERTIFICATE OF OCCUPANCY CHECK LIST y, Applicant U & R Certificate of Occupanc Address 99 E. Center Street Bldg. Permit No. J71,t Lot No. 20 Greenwood Drive Date Submitted9-24-89 Project Mt. Laurel Estates Reviewed By Date As required in the Zoning Regulations, no certificate-of-occupancy shall be issued until grading--plans—have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan. 2. Finish grading per approved building permit plan. 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location a. sanitary sewer b. foundation drain c. electrical & telephone d. water e. other 5. Appropriate certification 6. Bonding 6 ov Sewer Permit No. Pavement Excay. No. COMMENTS: BUILDING PERMIT Stonet r Group Building Permit No.7 Date Submitted 5-2-89 (ResubmittecAPilizan Ad :r i s Lo 20 123 Greenwood Drive)Davwed by Laurel ff Pr t Mt. 4, G-26-Vt with the Subdivision Regulations, prior to the building forInaccordancewi Topographic Plot Plan shall be submit any structure on, aimum rerequirements shall include r approval. The min q Approved Denied N/A 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. zone open space, 3. Zoning information - i.e- floodway, etc. 4. Plot plan at 1" = 40' scale. a. Subdivision reference, abutting Properties, etc. b. Easements of record. C. Lot description, bearings, distances, building lines, area, etc. o 00001 d. Contours, existing & posed, 1 or 2 ft.proposed, interval where appropriate. Building location with dimensions. e. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric, water, etc. h. Title block with name and address of preparer, date appropriate certification, _ live seal and signature. 5, Sedimentation and erosion control. 6. Special Planning & Zoning, Inland/Wetlands considerations._ (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS COMMENTS: to,aN at, cIaUr I VJe 4 w 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 R-CO AREA CODE 203/644-2511 DATE: September 29, 1989 Alco Aire Heating & Air Conditioning 69 Thomas Street East Hartford, Connecticut 06108 TO WHOM IT MAY CONCERN: Re: Lot 20 Greenwood Dr. South Windsor, CT. Your permit application cannot be processed for the following reason(s) Incomplete description of work Fee not included y Estimated cost not included Permit application not signed License # not included Telephone # not included Proper address not indicated Heat loss not included No engineering plans submitted X Other. The HVAC Permit has been processed. You will be receiving it in the Mali. —This memo is to verify that your check in the amount of $60 was returned in person to your agent. The fee for HVAC was covered in original Bldg. Permit. Y PEERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby : TOWN OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext . 230 7- Application must be printed or typed . Date Pilding Inspe or 1. LOCATION OF JOB 1.43 Lo` --A-4 a0 4V-e &-^ wLAJ 1DQ• FEE SCHEDULE No . Street 0 - $19000 - 10. 00 Floor Apt . No. Over $1 , 000 - 10 .00 per $1 ,000 or 2 . OWNER fraction thereof Q 3. ADDRESS & s A L0 L o G, 1 4. APPLICANT p(2 f) i tJ lie ( 5 . ADDRESS OZoy vy-z-Z`d 6 i o 9' 6. ESTIMATED COST $ I, o" 7 . IS THIS A CONTRACT COST Yes No p8. FEE ENCLOSED 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB : original Installation Alteration/Addition/Repair BD 3A 11/88 — APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB Lj #,2ZO CJZ e ejv x',, c d Q NO. STREET APT. NO, 12 . TYPE OF INSTALLATION dk o M 13 . SIZE OF MAIN FEEDER Q 14 . NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16 . NO . OF POWER LOOPS 17 . NO . OF LIGHT OUTLETS v2S 18 . NO . OF HEAT CIRCUITS 19 . NO . OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS J 0 21 . NO . OF HEAT CIRCUITS 22 . NO,) OF POWER CIRCUITS 23 . NO. OF LIGHT CIRCUITS /,2 24 . SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO. OF PANELS 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30 30 . A/C LOAD S w_ 31 . SIZE OF POWER FEEDERS 32 . NO . OF FIXTURES 2.j 33 . TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES______ 35 . REMARKS AND FURTHER DETAILS : 102-96 C, LICENSE NO . SIGN AT R OF APPLICANT DATE PHONE NUMBER : S_a cl- 3 c)o / Lot No. Building Permit_T Temporary Service Permanent Service`" Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. tAOwnerElectrician Zt, Street r e 1 Building Inspector PERMIT NO. DEPARTMENT DECISION APPL I CAT I O N FOR APPLICA ION IS HEREBY: PLUMBING PERMIT APPROVED DISAPPROVED TOWM OF SOUTH WINDSOR BUILDING INSPECTION DEPT. 2 644-2511 Ext. 2306-a. -af DATE PL ING INSPECTOR Application must be printed or typed. 1. LOCATION OF JOB: 9 3 .2frV4e AeveP V'e t07- 2. OWNER: 3. ADDRESS: J FEE SCHEDULE 0 - $1,000 - $10.00 4. APPLICANT: Over $1,000 - $10.00 5. ADDRESS: per $1,000 or Fraction Thereof f 6. EST. COST: $ /OBdo 7. IS THIS A CONTRACT COST? J,,;ffS NO 8. FEE ENCLOSED: $ 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) n311. LOCATION OF JOB: C! p oyS %.3 lJ c'1'iGyn U, GENERAL PLUMBING 12. KIND OF INSTALLATION: rl 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE a,2 15. NO. OF URINALS p STYLE 16. NO. OF BATHTUBS /16A. NO. OF SHOWERS _ 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL_ 19A. DISWASHER 20. NO. OF CONDUCTORS --- SIZE 21. NO. OF STACKS l SIZE.?" 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES_ KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK?ter 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS z ' 32. REMARKS AND FURTHER DETAILS yi fog WATER HEATER 33. TYPE p 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY To 39. RELIEF VALVE V 36. TEST PRESSURE LBS. 40. MANUFACTURER (yc, 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER LICENSE NO. DATY SIGNATU OF APPLICANT PHONE NO. i FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: /t.' frf N0.TOWN OF SOUTH WINDSOR EST.COS Ce Q BLDG. PERMIT NO. 7 1540 SULLIVAN AVENUE FEE A-P SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING r.4&f ev uo Lev• thereof - $10.00 OWNER ADDRESS TOWN PHONE NO. v l a A7+'r L (j C,(a HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING 1/ TYPE OF BUILDING: RESIDENTIAL J.,Z A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS./ HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE_0_°F INSIDE_/OF DIFFERENCES OF TOTAL HEAT LOSS (BTUH) jo G HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPM NT (INCLUDING MAKE & MODEL N0.) : £,,L, O ,,l.• (A— GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) .Srd d IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE ,r"°F DIFFERENCE_/r:_°F TOTAL HEAT GAIN (BTUH) S".%C)o o HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.) : • " A v, Gl4 v C o 2 Goa efi--(, TONNAGE COOLING CAPACITY (BTUH) g7i 00 IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 0 .1 /0 L_ 741JI, 41. STATE fICENSE - NAME & TYPE #DA E SIGNATURE OF APPLICANT Qhre_ 1Aq/vzv APPROVED DA E BD 4A 11/88 B= R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM Q O H L W N L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT O BTUH per F of f 3 LENGTH EXPOSED WALLS, FT. Q Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION Table 9, Line 3 x H) ROOM LIN.FT.OF TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used for Line 5) 7 CEILING CONSTRUCTION C Table 9, L x W) B FLOOR CONSTRUCTIONt D— Table 9, L x W or Lin F it E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H) lU c 1 Well(With Openings) 0 -- 2 Walls(With Openings) z X 3 Walls(With Openings) or Ent Hell H I r11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL A COL B COL.H COL 1 COL J COL K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION1ROOMa:AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.' 2 ROOM DIMENSIONS, FT DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT 4 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, Line 3 x H)TOTAL 20% 6 TYPE OF GLASS Bottom of table used for Line 5) 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON Table 9, L x W) GROUND OR FILL AT GRADE LEVEL,USE LINEAR g FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9, L x W or Lin Ft 1 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 c 1 Well(With Openings)G 0 e; c a 2 Walls(With Openings) x 3 Walls(With Openings)or Ent Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form is available from The Hydronics Institute,35 Russo Place,Berkeley Heights,N J 07922 FORM 1503 HEATING I rA SH Efi r r OUTSIDE DESIGN TEMP C? --__ HEATING CONTRACTOR ADDRESS INSIDE DESIGN TEMP........Fes_........._....... t l_1— Il.,_ a/•••1.NAME OF JOB._._ .-____._ 'Sr iC _"` ! _ _...__ ADDRESS DESIGN TEMP.DIFF..-_.._.....Fd_...... I. Room Use and Floor Lev I I. 1 ,, 2- ` v , ( 3. F. , A- 4. ' S. 6. 7. 8. 9. 2. R om Length and Width Fj x 13 X rIG x 16 -7-g X / G X I z X G 3. Running Ft of Exposed Wall 3 10 S, e 6 4. Ceiling Height 13 g f< S. Exposure Table "W- Multi. Area Area Area Area Area Area Area Area Area No. Factor plier Crack stub Crack stub Crack stub Crack stub Crack Btuh Crack stub Crack Btuh Crack BtOh Crack Btuh Type Cfm Loss Cfm Loss Cfm Loss Cfm Loss Cfm Loss Cfm Loss Cfm Loss Cfm Loss Cfm Loss Gr y l R;av iy..j.r r 't•`.:a ifi/.-• r`S: .t Se r ,T t n. i t' 1.c jf• lriw t:.Zs: ti+'' r '}.R 4 C;r •rA1''l fA 6. Wall a O k tC..•sx OQ `•r;t''l ar Z ,`'L;^: 1.? 'I` !•tia iF 2`` b •''•"' l?•i7ri ..t F l ' ..i 1 -T.•• r.v - • vIb A• tir so o 3 s'o o o o G 316c,o 0 Wind ws 7. and Doors Jr Net 8 S o Duo D 62 S' 8. Exposed Wall cold Ceiling oo: 1 — — r 0 QCz U G r,ir Crerga 13. Room Sub-T tal Btuh 7 p 1 4 2_ o g 3 G 5r 14. Btuh Adjustment 15. R m Total Btuh g 16. Cfm 0 T mp.Rise 17. Adjusted fm 1 LENNOX Equip Blower_Motor hp Construction Loose__ Btuh (Input-output) Cfm..—...Drivas...._.-_...._ Ventilation Loss._ Fuel S.P_ Total Loss._ Ob Rpm___ m fj„-,vi,4' 16 HEATING DATA SHEET DATE.._.__.__........ _:_.__._BY- __._ OUTSIDE DESIGN TEMP.___. HEATING CONTRACTOR___-_- ADDRESS -_.._..___ __.... r- INSIDE DESIGN TEMP_._......_._.._...._._._..____ NAM__ OF JOB.—.. ADDRESS ._._...._...._._ —._.,._. DESIGN TEMP.DIFF. ........... ............... I. R om Use and Fl r Level I. -? 2. {S` 3. 4. Z S. 3 6. p 7. 8. v^ 9. 2. Room Length and Width g X (¢ x / Z 2- Running Ft f Exposed Wall tom 7 4. Ceiling Height 91 Y S. Exposure Table ..U.. Multi- Area stubArea stubArea Area Area PullArea stubArea Area Area No. Factor plier Crack Loss Crack Loss Crack Louuh Crack Stub Crack Loss Crack Loss Crack 8fuh Crack 8fuh Crack Stub TYp Cfm LOSS Cfm Loss Cfm L Cfm to:: Cfm Loss Cfm Loss Cfm Loss Cfm toss Cfm loss Gross r',. jj,r i':`t r%' '-.y. :`t+ ,..:.+. Wall s r '';C -1. Y, y r,,: 1,..,, ••a CIM, v 4 3ro q 1 Sa •k 1400 z-g 14,00 1 Z- 1GoCP' GS 3 S Windows 7. and Doors Net J S I IO Dg S40 O C 3 ZO 'I S. Exposed Wall F_T_ i I Li q' '3 G 1,ZY2 a o g '13 S'- o 1-o 60 71-c SO i o A 3 sag' - 153 Z__S' .g'_f, 3L _LoB'_13 Paz - - --- --- _`f" $3fo •---'--- ---- 13. Room Sub-Total Btuh S-?4 3 2-T 14. Btuh Adjustm nt . 15. Room T tal Btuh 16. Cfm @ Temp.Ris• 17. Adjusted cfm LENNOX Equip.__.Blower Motor hp Construction Loss__ Btuh (Input-Output) Cfm.. Drivas__._.._. Ventilation Loss... Fuel.. _ __.— S.P.—Rpm_Total Form No RCD 682-L11 S_16-12-69 Job No. Date LENNOX RESIDENTIAL COOLING DATA SHEET Outside Design Temp.DB WB Inside Design Temp. Daily Range Design Temp.Diff.Latitude HEATING CONTRACTOR ADDRESS Floor Area By NAME OF JOB ADDRESS I. Room Use and Floor Level i. 1• Jv 2 3 e 4 6. 7. 8 2.Room Length and Width aY>t'• X X O O h G Area Area Area Area Area Area Area Area Type and Direction 61 TABLE Stuh Btuh or Btuh Btuh Btuh Btuh Stuh Btuh Exposure NUMBER HTM or Gain or Gain o Gain or Gain or Gain o Gain or Gain or Gain No. No No. No. No. No. N No yNORTHExposedWallLength <<• t-';n-'•:, •::' +},ti<:< ram.. Y. y ar`;T Li, tix_'' _ 'i^ : .IN OR SHADED) Ceii vlei ht Z. lt`: ''+3,,1•iz" - :•7'is;` tP A t w Solar& q -. Glass Area i- _ ! r=JT _ _:p= "+ .Vail ": _ r'- _%.<'4.': ,•y "•'','.Tom."•, -:?-'-- -i:.X • l ;;r.., •` r~-' 1 _ - :.-- Fit v Y N. ::•_ : .'+%.•^'': a— a+ ^•,y '--___rz r``-`- ,fi'..` $' r%M'i.••. '-;r'•- _^:'r;t""e`__ - •• ') 41_.Wa•i 31-lc 0.oSS cao5c'd:"Ja!I +'ti Z •,!' y '+•^i 44 i„i,t ''/ +a••': tir: i F..: '. :r:_ti y • i.- ` i-- 1 Solar& Sq F t Glass Area I- O Conduction) Net Exposed Wall 61 Ielf,i L OUTH Fx:;i.;edWall Length t,'si'%/• r,r"tiL i..'t.a=: 7 J y:: +% I `r:~ L•+: all. Ng14h[ v• •.:'.-•r j` 9v` i p •737ts-`=M,-N•'"-,' ;r1 f. LT. ..Ia:!'-'L' s•r ~.•-!J'J3Ji • _• 'i"•_ O ./- Y +t'! •.sue I 1•= V. 4'.1 t.•' r __ -- _ j Naii a^d C1 j-s .3ross x ocS2(1'I'.' I I --- -I:`, r. 1!.p. :3 r f+': rc••'.t+: i - 1 ;i•.}'w Solar& Sq Ft Glass Area 7e ),p Conduction) Net Exposed Wall 04I Z I WEST Exposed Wall Length fi r. S i• 13`: f•t t4`:r %i r iJ Ceiling Height r..fir Y }Jjis ter'•`a r. 1 J !• i 1 •.: C r w 6. Wall and Glass Gross E x osed W II ` t,L.•.;p a mot':fit• •1 14 22 Solar& Sq F t Glass Area 3/0 C Conduction) Net Exposed Wall Z• i Zo L 574 7.Wood Doors Z L 2SAry 8.Warm Partition 9.Warm Ceiling 160 3 3-0 10 Warm Floor 11. Appliances-Kitchen(Sensible) o •;'• y,J, 12.People!Sensible) 11001 ;- (,onCIO O w 3 0 1 o O 13.Outside Air or Infiltration (Sensible)f. 2$$ 0 L 14.Sub-Total-Sensible N ->?d ss. j* ±:S t s • 15. Duct Allowance 96 16. Total Sensible le,;. 5_0 r".1C(I F v '-'•' Sf l 17 Total Latent .3 x Tot Sensible c,• .• ;! ' - t; f1?• x•: s=':• 18. Total Sensible&Latent x : i .S •'%- O w' 19.Theoretical0m r''"- , . :,; i1 20. Delivered cfm s_-r :' _i;, t1A:• CAP.MULTIPLIER Fo PF Swing) ILENNOX Equip, etuh Cap. 0 OF MIN.EQUIP.CAP.OARI Rating Cfm Rpm Air Changes S/T Rail S.P. Litho u.sA. A t Form No RCD 682-L11 S-16-12-69 Job No. Date LENNOX RESIDENTIAL COOLING DATA SHEET Outside Design Temp. DB WB Inside Design Temp. Daily Range Design Temp.Diff.Latitude HEATING CONTRACTOR ADDRESS Floor Area By NAME OF JOB ADDRESS 1. Room Use and Floor Level I-b 2 3 Q 4 ( Z 6 A I 7. 8. 2. Room Length and Width cdK I¢ x1scx Type and Direction 61 TABLE Area Stuh Area Btuh Area Btuh Area gtuh Area Btuh Area Btuh Area Btuh Area Btuh HTM or or or or No. or or or orExposureNUMBERIGain No No Gain `yo u3in No. Gain No Gain No Gain i Gain I T.1773=--- _a.o c.. .., -- r-r- - ram,L••'r: y tip?-sic-:— -- nr ISOIar& Jy =t Gass Area - i—O _ -_ _- _' — _.,__ - --•,`--- Conduction) Net cxpose(l,.Vail f l e" -- D iV•.:r 'i:..;.,,p ate/.c-. --"-""'' _ c: LSS - - - - - - r - :1` 4.¢ .rc. •^Y-,! rat-..- "•". r:_, _ '•_ } d- Solar& JQ r :ioss,.r2 1 L Conduction) Net Exposed Wall t L O ,Zf I i i L I SOUTH E xoosed'.'Vail 'en th G` r fY-r( + I• 1. A/• y•f• •_• Imo` ,l 7 1 I%t•... J ••9 t. '!• g r :7 7 .. ry T. 3"'.fElChi i,iti•!•r1 - p• ••'! .... /. '• `:- i•' j1•t' .L•. / ! •'1- tea.••..sv'( i..•'^at' I• s D •r•• i/• L•! : / '•,y:i%•.. fv.'11- r-.ti.. ross ExoosedVVall -..: ;1 4.t•,J?' i" ' f•T'. t 'e't 4'^,= i t e,:' _ }... .. _ Jr_' ar 3. Sq Ft Glass Area Cor,duction) Net Exposed Wall 1 7 0 OIr1 EST Exposed Wall Length - vW9 - ' .1. ,r til:Ff '• .1:.•:'t• {'f .;J:',ial.r-'=: i ," -.., Ceiling Height r''•. f 4s ;::*1 i• ;= _ "'4 .. 6. Wall and Glass Gross Exposed Wall to •• s _ v'• Solar& S Ft Glass Area I4Z Conduction) Net Exposed Wall 7.Wood Doors 8.Warm Partition 9.Warm Ceiling 3 L o i-o S C a 10.Warm Floor 11. Appliances-Kitchen(Sensible) t t t12.People(S nsible) 300 iP'- 13.Outside Air r Infiltration(Sensible)Sz- le O 14.Sub-Total-Sensible t " -i1`•,• y { r1S.1 1rf ice. y15. Duct Allowance 96 16. Total Sensible 4-a '''=•'l ,Z 3 Z S 17.Total Latent .3 x Tot Sensible c+•:. =`!';N :• F rat;y• 18.Total Sensible&Latent O 4 1- 19.Theoretical cfm t=•'•. "+;••,: f f4I:n 20. D Iiveredcfm y;lNr CAP• MULTIPLIER Fo PF Swing) LENNOX Equip. Btuh Cap.@, QF MJN.EQUIP.CAP. ARI Rating Cfm Rpm Air Chang s S/T Rati S.P. Loth U.S.A. 0J 7Q