Loading...
HomeMy WebLinkAbout121 Maskel Road (2)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 7 3 3 APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# U 644-2511 ext. 230 Datt Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: I Z l Wle-s,C_( 0-$1)000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. D/t APPLICANT Gi rr APPLICANT ADDRESS Ca Z APPLICANT PHONE# 0%o O* N S F OWNER 4 OWNER ADDRESS Z( s y # OWNER PHONE C ESTIMATED COST$leoV.Uo IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ 30 TYPE OF JOB: OR.CO New Installation Alteration/Addition/Repair Revised 4/01H2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: IEATING RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. T9piYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION f O4ADDITIONAL RADIATION fPOTAL RADIATION W 1/0D DESIGN TEMP. OUTSIDEI 0 OF INSIDE 70 OF DIFFERENCE -26 OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) tq DEES/CRIBE ALL HEATING QUIPMENT CLUDING MA &MODEL NO.) GROSS HEATING CAPACITY(INPUT BTUH) 130 NET RATING(OUTPUT-BTUH)4.JU-w TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY Z GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 70 kcp CONTRACTORS LICENSE NO. T E STATE SIGNATURE OF APPLICANT `` 2 DATE AZO RIGHT-J SHORT FORM Entire House0GirouardPlumbing LLC Maskel g ange r s. 121 03 662 Graham Rd,S Windsor,CT 06074 Phone-860-644-1979 Project Information For: David A. Patria Co. 635 Nevers Rd, S. Windsor„ CT 06074 Phone: 644-1796 Design Information Htg Cig Infiltration Outside db (°F) 5 97 Method Simplified Inside db (°FF)70 75 Construction quality Average Design TD (°F) 75 22 Fireplaces 0 Daily range M Inside humidity (%) 50 Moisture difference (gr/lb) - 37 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a n/a n/a n/a Efficiency n/a Efficiency n/a Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 560 Btuh/ft Total cooling 0 Btuh Total low baseboard 41 ft Actual cooling fan 0 cfm High output baseboard 750 Btuh/ft Cooling air flow factor 0.000 cfm/Btuh Total high baseboard 30 ft Space thermostat Load sensible heat ratio 0 % ROOM NAME Area Htg load Clg load Baseboard (ft) Clg AVF ft2) Btuh) Btuh) Low High (cfm) Mudroom 48 3099 0 6 4 0 Laundry room 64 1619 0 3 2 0 Great room I 504 11901 I 0 + 21 16 I 0 Master bedroom 180 5308 0 9 7 0 Master bathroom 80 324 0 1 0 0 W.I.Closet 64 562 0 1 1 0 Entire House 940 22813 0 41 30 0 Ventilation air 0 0 Equip. @ 1.02 RSM 0 Latent cooling 0 TOTALS 940 22813 0 41 30 0 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. Awrightsoft Right-Suite ResidentialTm 5 0.28 RSR20089 2003-May-19 20 55:16 ck C.\My Documents\Right J calculationslangtange res 121 Maskel Rd rsr Page 1 3`, 1 d.r