Loading...
HomeMy WebLinkAbout120 Bridlewood Road (7)r DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APP 1540 SULLIVAN AVENUE Bldg.Permit# L4a644- 2511 ext. 230 Building Inspector Application must be printed or typed Location of/Job: FEE SCHED I I a o 06(-id e kzad D Le I 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Z&," 4 e-- APPLICANT ADDRESS ?O rq z APPLICANT PHONE# W N S OWNER Alf'ft-- /J r O F 4 OWNER ADDRESS O act rFN yam; t# e OWNER PHONE ESTIMATED COST$ IS THIS A CONTRACT COST? &.Yes O No ICJ FEE ENCLOSED$ TYPE OF JOB: OR-Co x6ew Installation 0 Alteration/Addition/Repair Revised 8/99 a APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: All-HEATING ALRESIDENTIAL c/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC C WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE 652 °F INSIDE 7 5- °F DIFFERENCE 7 5 ' OF TOTAL HEAT LOSS(BTUH)?,tt F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) ro&P NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION :INSIDE OUTSIDE CAPACITY Ld GAS—INPUT/ LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE°F INSIDE 75°F DIFFERENCE Z °F TOTAL HEAT GAIN(BTUH)#7,711-- (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE C COOLING CAPACITY(BTUH) ` et VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK ',/u c THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. E STATE SIGNATURE OF APPLICANT DATE 6 ler Z BRIDLEWOOD RD, SO. WINDSOR HVAC LOAD ANALYSIS for Ltitejo%vare RHVACft° nxm°uw C HVAC LOADS Prepared By: Stephen P.Smith Advanced Heating&AC Inc. 701 Nutmeg Rd.North So.Windsor,Ct.00074 860)282-0205 06-26-02 Flamm Project: Bridlewood Rd, So. Windsor Company: Advanced Heating&AC Inc. Client: MrA Mrs. Harold Thomas Representative: Stephen P. Smith Address: Address: 701 Nutmeg Rd. North City. City: So. Windsor, Ct. 06074 Phone: 568-7760 Phone:860)282-0205 Fax: 568-7760 Fax: 860)528-2949 Comment: Project Name: Bridlewood Rd, So. Windsor Reference City: Hartford, Connecticut Daily Temperature Range: Medium Latitude: 41 Degrees El vation: 19 Feet Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter. 7 N/A N/A 72 N/A Summ r: 88 73 50% 75 33 Total Building Supply CFM: 1497 CFM per square foot: 0.641 Square feet of room area: 2,337 Square feet per ton: 656.13 Total heating required with outside air: 92,621 Btuh 92,621 MBH Total sensible gain: 32,911 Btuh 90 % Total latent gain: 3,761 Btuh 10 % Total cooling required with outside air: 36,672 Btuh 3.056 Tons(based on sensible+ latent) 3.562 Tons(based on 77%sensible capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Tuesday,June 25,2002 Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 445 20,971 0 17,633 17,633 11A Door Metal Fiberglass Core 20 767 0 196 196 12H Wall R-19+ 1/2"Gypsum Board(R-0.5)2,629 12,334 0 3,148 3,148 16D C iling R-19 Insulation 1,823 6,280 0 3,574 3,574 19A Floor Over Basement/Encl Crawl Hardwood No Insulation 598 6,064 0 0 0 201 Floor Over Open Crawl Carpet+ R-19 1,315 4,103 0 506 506 Subtotals for structure: 6,830 50,519 0 25,057 25,057 eve People: 0 0 0 0 0 Inacive People: 0 0 0 0 0 Appliances:0 0 0 0 0 Lighting: 0 0 0 Ductwork: 0 15,437 0 5,485 5,485 Infiltration: Winter CFM: 373.2, Summer CFM: 165.9 465 26,665 3,761 2,369 6,130 V ntilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 32,911 Temperature Swing Multiplier:X1 00 Building Load Totals: 92,621 3,761 32,911 36,672 Total Building Supply CFM: 1497 CFM per square foot: 0.641 Square feet of room area: 2,337 Square feet per ton: 656.13 Total heating required with outside air: 92,621 Btuh 92.621 MBH Total sensible gain: 32,911 Btuh 90 % Total latent gain: 3,761 Btuh 10 % Total cooling required with outside air: 36,672 Btuh 3.056 Tons(based on sensible+latent) 3.562 Tons(based on 77%sensible capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Tuesday,June 25,2002 Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM Zone 1- 1 Study 192 5,719 74 1-4 684 1,312 267 60 1.00 60 60 2 Foyer 64 1,392 18 1-4 210 403 24 18 1.00 18 18 3 Dining 144 10,349 134 2-4 691 2,650 534 121 1.00 121 121 4 Kitchen 144 3,313 43 1-5 549 1,645 97 75 1.25 94 75 5 Breakfast 132 11,784 153 3-5 644 5,788 655 263 1.35 355 263 6 Great 306 16,679 217 3-6 461 5,975 728 272 1.18 320 272 7 Master Suite 598 20,608 268 3-5 600 5,394 599 245 1.19 293 245 Zone 1 Subtotal 1580 69,844 908 23,167 2,904 1,054 1,261 1,054 Zone 2- 8 Bed 3 168 5,152 67 2-5 494 2,960 202 135 1.00 135 135 9 2nd FI. Lav 102 1,316 17 1-4 270 518 24 24 1.00 24 24 10 Bed 4 154 6,319 82 1-5 583 1,747 324 79 1.00 79 79 Zone I Subtotal 424 12,787 166 5,225 550 238 238 23$ Zone 3- It Bonus 333 9,990 130 2-6 523 4,519 307 206 1.00 206 2Wf Zone 3 Subtotal 333 9,990 130 4,519 307 206 206 20tr System 1 Totals 2337 92,621 1,204 32,911 3,761 1,497 1,704 1,497 Main Trunk Size: 16x16 in. Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 3.056 900/0/10% 32,911 3,761 366,672 Recommended: 3.562 770/o/23% 32,911 9,831 42,742 Tuesday,June 25,2002