Loading...
HomeMy WebLinkAbout12 Kelly Road (8)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WIl TDSOR rPERMIT#Application is hereby: 1 7 ,3oZBUILDINGDEPARTMENT PROVED 1540 SULLIVAN AVENUE Bldg.Permit#644-2511 ext. 230 ate Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS APPLICANT PHONi# OWN S OWNER S q< OWNER ADDRESS S C*1 - * OWNER PHONE Z Z- 3 I C ESTIMATED COST$ g O a Vol IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ TYPE OF JOB: OIt•C 0 New 1Instalation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING RESIDENTIAL wwC COMMERCIAL EN'')_L OI_U INDU`'RIAL, HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE r OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUIT) NET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF N INSIDE OF DIFFERENCE F TOTAL HEAT GAIN(BTUH)/L (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 0 /Z TONNAGE COOLING CAPACITY(BTUH) VZ-0 d VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. f CONTRAC OR LICENSE TYPE STATE SIGNATURE OF APPLICAN DATE R E C E I V I N G C a SIN 6025 RIGHT-J SHORT FORM File name: Job t: Ht9 C19 For: Outside db 4 Be Inside db 70 15 Design TD 66 13 Daily Range - M Inside Humid. - 50 By: HERITAGE OIL Grains Water - 29 Method Simplified Const. glty Average Fireplaces I HEATING EQUIPMENT COOLING EQUIPMENT Make Make Model Model Type Type Efficiency / HSPF 0.0 COP/EER/SEER 0.0 Heating Input 0 Btuh Sensible Cooling 0 Btuh Heating Output 0 Btuh latent Cooling 0 Btuh Heating Temp Rise 0 Deg F Total Cooling 0 Btuh Actual Heating Fan 1400 CFN Actual Cooling Fan 1400 CFM Htg Air Flow Factor 0.019 CFM/Btuh Clg Air Flow Factor 0.042 CFM/Btuh Space Thermostat load Sensible Heat Ratio 85 ROOM NAME I AREA I HTG I CLG I HTG I CLG SQ.FT. { BTUH I BTUH { CFN CFM DEN I 160 I 5908 I 2146 i 110 1 89 FAMILY ROOM 272 ( 9821 { 4591 ( 183 {191 BREAKFAST I 96 i 8376 I 4179 I 156 I 174 KITCHEN I 120 I 1907 I 2632 I 35 { 110 DINING ROOM 210 I 6646 I 1707 ( 124 71 FOYER I 192 I 9735 I 1852 i 181 I 11 LIVING ROOM 224 { 6860 { 2348 { 128 {98 MASTER BATH I 192 I 5967 I 4193 I 111 I 175 BEDROOM 3 192 ( 3814 { 1606 { 71 { 61 BEDROOM 4 I 100 I 3973 I 1518 I 14 {66 tAUNDRY/ BATH 100 ( 736 ( 2760 { 14 {115 BEDROOM 2 I 140 I 4267 I 1201 I 19 I 5o MASTER BEDROOM 260 { 7182 { 2708 { 134 ( 116 Entire House d{ 2258 { 75198 { 33581 { 1400 { 1400 Ventilation Air I 1 0 1 0 1 1 Equip. 0 0.95 RSM ( 31902 I Latent Cooling I I i 5939 I TOTALS 2258 I 75198 ( 37841 I 1400 I 1400 MANUAL J: 1th Ed. RIGHT-J: V2.11