HomeMy WebLinkAbout12 Farnham RoadDEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 0 7 (0 6 APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE FTenant LJoc/a/tion of Job: Fa-e d- 0-$1,000=$15.00 o. Street Lot No. Over$1,000$ 15.00 per$1,000 or any fraction thereof esignation Apt.No. I HIPOINT HEATING&COOUNG,MAPPLICANT71EDw*;,w!nn SOUTHAPPLICANTADDRESS VIfINDSOR,CT o®074 i t1 0 t APPLICANT PHONE# 02 l —D W N S OWNER O q< ONER ADDRESS elk ar..wW I`t a• O M 300 OWNER PHONE a Ip C ESTIMATED COST$ /Q, Ll $ d o IS THIS A CONTRACT COST? x Yes No r FEE ENCLOSED$ (&. • O Co TYPE OF JOB: soR,Co New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING RESIDENTIAL q-AlC COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING f DESIGN TEMP.OUTSIDE ell10 OF DIFFERENCE OF TOTAL HEAT GAIN(BTUHVEUIPMENTHEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESC E ALL COOLING INC ING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH)62 GVC VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3 o3 CONTRACTORS LICENS N TYPE STATE ISSIGNATUREOFAPPLICAN DATE_ b C y RHVAC-Reald ntlal&Light C mmercial HVAC Loads Program Elute Software Development,Inc.Connair 6 Orange,CT 06477-3601 3-13-02 Page 2 Proj ct Summary Project:Company: Hipoint Heating&CoolingClient: Representative: Steven Clark Address: Address: 71 Edwin Road City: City: South Windsor, CT 06074 Phone: Phone:860)291-0181 Fax: Fax: 860)291-0020 Comment: E-Mail hipointcooling@aol.com Design Data Project Name: Reference City: Hartford, Connecticut Daily Temp rature Range: Medium Latitude: 41 Degrees El vation: 19 Feet Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 7 N/A N/A 72 N/A Summer: 88 73 50% 75 33 Ch ck Figures Total Building Supply CFM: 740 CFM per square foot:0.82 Square feet of room area: 902 Square feet per ton: 512.639 Building Loads Total heating required with outside air: 33,304 Btuh 33.304 MBH Total sensible gain:16,258 Btuh 81 % Total latent gain: 3,850 Btuh 19 % Total cooling required with outside air: 20,108 Btuh 1.676 Tons(based on sensible+latent) 1.760 Tons(based on 77%sensible capacity) Not s Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Saturday,May 31,2003