Loading...
HomeMy WebLinkAbout110 Brook Street (9)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# 16 n14 Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bld Permit# APPROVED 1540 SULLIVAN AVENUE YY 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location of job 0 3 00K ST -— Street No. Street Lot No. FEE SCHEDULE 0 - $1,000 - $12.00 Floor Apt.No. Over $1,000 12.00 per$1,000 OWNER &vw&v4V/Soranyfractionthereof ADDRESS /10 EAOOK SS7.- 6F-T SAr4 #,)DSd CT' 06,,-67 OWNERS PHONE# q APPLICANTgASd6JV 6±A**VY EMI N SF ADDRESS 3T0 TL-C,1}NQ E s ep CT" o COD ESTIMATED COST C IS THIS A CONTRACT COST? YES NO C.FEE ENCLOSED $ TOa 0 TYPE OF JOB:OR C Original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL ABC COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE F INSIDE F DIFFERENCE F TOTAL HEAT LOSS(BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) TYPE OF FUEL OIL-GPM GAS-INPUT ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE 15' F INSIDE 75"'F DIFFERENCE F TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) Aw aic4A cotiO. I5de, 7Arga,3DA- 0V A c 4A fhb-t{1^iDl NC 0 30 G•1 t9- TONNAGE 01- COOLING CAPACITY(BTUH) 30,1W VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK DNS L c 5 wcTw 2r e Lbn D l' 4 am THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 30 STATE LICENSE-NO. NAME&TYPE SIGNA E OF APPLICANT PHONE NO. 3 DATE aJ 01-01-80 60601903. 15 DETAILED REPORT FOR ENTIRE HOUSE Prepared For: Prepared By: RAYMOND JARVIS HJC 110 BROOK ST KASDEN FUEL CO SOUTH WINDSOR , CT 06074 Job Name: JARVIS EXPOSURE GLASS NORTH SOUTH EAST WEST NE/NW SE/SW HORZ. TOTAL AREA 36 | 48 | 36 | 36 | 0 | 011 156 | COOLING | 842 | 1 ,507 | 2,030 ( 2,030 | 0 | 0 | 0 | 6,410 | HEATING | 1 , 129 | 115051 11129 | 11129 | 0 | 0 | 0 | 4,891 | BELOW WALLS NORTH SOUTH EAST WEST NE/NW SE/SW GRADE TOTAL AREA 279 | 267 | 252 | 252 | 0 | 0 | 0 | 1 ,050 | COOLING | 448 | 429 | 4051, 405 ( 0 | 01 0 | 1 ,686 | HEATING | 1 ,423 | 1 ,362 | 1 ,286 | 1 ,286 | 0 | 0 | 0 | 5,357 | DOORS NORTH SOUTH EAST WEST NE/NW SE/SW TOTAL AREA 21 | 21 | 0 | 0 | 0 | 0 |42 | COOLING | 292 | 292 | 0 | 0 | 0 | 0 |585 | HEATING | 929 | 929 | 0 | 0 | 0 | 0 |1 ,858 | FLOOR AREA COOLING HEATING 1250 0 | 1 ,290 CEILING AREA COOLING HEATING 1250 19476 | 7,382 MISCELLANEOUS COOLING LOADS People Sensible Load 900 Latent Load 3, 135 Lights & Appl . Load 0 Latent Safety Btuh 941 Ventilation Load 0 Duct Heat Gain 0 Infiltration Load 556 Sensible Safety Btuh 34484 TOTAL SENSIBLE LOAD 15,097 TOTAL LATENT LOAD 4,076 Summer ACH 0. 15 Temp. Swing Mult. 1 . 00 Total Cooling Load 19, 173 BTUH Or 1 . 60 Tons *** MISCELLANEOUS HEATING LOADS Infiltration Load 44167 Ventilation Load 0 Duct Heat Loss 0 Safety Btuh 7,483 Winter ACH 0. 30 Total Heating Load 32,428 BTUH *** 01-01-80 60601903. 15 SUMMARY REPORT Prepared For: Prepared By: RAYMOND JARVIS HJC 110 BROOK ST KASDEN FUEL CO SOUTH WINDSOR , CT 06074 Job Name: JARVIS DESIGN CONDITIONS for SOUTH WINDSOR OUTDOOR INDOOR SUMMER WINTER SUMMER WINTER Dry Bulb 95 5 75 70 Wet Bulb 75 62 Daily Range 21 Daily Swing 3. 0 Latitude 40 Elevation 300 Safety Factor (%) 30 Latent Factor (%) 27 Sensible Room Heating Heating Cooling Cooling Name BTUH CFM BTUH CFM WHOLE HOUSE 329428 454 15,097 762 32,428 454 151097 762 HEATING DELTA T 65. 0 COOLING DELTA T 18. 0 NOTE: *** Calculated Airflow is based upon load requirements. Verify that airflow calculated is compatible with selected equipment requirements. ***