HomeMy WebLinkAbout110 Brook Street (9)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT#
16 n14
Application is hereby: TOWN of SOUTH WINDSOR
BUILDING DEPARTMENT Bld Permit#
APPROVED 1540 SULLIVAN AVENUE YY
644-2511 ext. 230
Date Building Inspector
Application must be printed or typed
Location of job
0 3 00K ST -—
Street No. Street Lot No.
FEE SCHEDULE
0 - $1,000 - $12.00
Floor Apt.No.
Over $1,000
12.00 per$1,000 OWNER &vw&v4V/Soranyfractionthereof
ADDRESS /10 EAOOK SS7.- 6F-T
SAr4 #,)DSd CT' 06,,-67
OWNERS PHONE# q
APPLICANTgASd6JV 6±A**VY
EMI N SF ADDRESS 3T0 TL-C,1}NQ
E s ep CT" o
COD ESTIMATED COST
C IS THIS A CONTRACT COST?
YES NO
C.FEE ENCLOSED $ TOa
0 TYPE OF JOB:OR C
Original Installation
Alteration/Addition/Repair
Revised 11/95
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM TYPE OF BUILDING
HEATING RESIDENTIAL
ABC COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE F INSIDE F DIFFERENCE F
TOTAL HEAT LOSS(BTUH)
HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH)
TYPE OF FUEL
OIL-GPM GAS-INPUT ELECTRIC-KW
OIL TANK SIZE&LOCATION
INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY
AIR CONDITIONING
DESIGN TEMP. OUTSIDE 15' F INSIDE 75"'F DIFFERENCE F
TOTAL HEAT GAIN(BTUH)
HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.)
Aw aic4A cotiO. I5de, 7Arga,3DA- 0V A
c 4A fhb-t{1^iDl NC 0 30 G•1 t9-
TONNAGE 01- COOLING CAPACITY(BTUH) 30,1W
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK DNS L c 5 wcTw 2r e Lbn D l' 4
am
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
30
STATE LICENSE-NO. NAME&TYPE SIGNA E OF APPLICANT
PHONE NO. 3 DATE aJ
01-01-80
60601903. 15
DETAILED REPORT FOR ENTIRE HOUSE
Prepared For: Prepared By:
RAYMOND JARVIS HJC
110 BROOK ST KASDEN FUEL CO
SOUTH WINDSOR , CT 06074 Job Name: JARVIS
EXPOSURE
GLASS NORTH SOUTH EAST WEST NE/NW SE/SW HORZ. TOTAL
AREA 36 | 48 | 36 | 36 | 0 | 011 156 |
COOLING | 842 | 1 ,507 | 2,030 ( 2,030 | 0 | 0 | 0 | 6,410 |
HEATING | 1 , 129 | 115051 11129 | 11129 | 0 | 0 | 0 | 4,891 |
BELOW
WALLS NORTH SOUTH EAST WEST NE/NW SE/SW GRADE TOTAL
AREA 279 | 267 | 252 | 252 | 0 | 0 | 0 | 1 ,050 |
COOLING | 448 | 429 | 4051, 405 ( 0 | 01 0 | 1 ,686 |
HEATING | 1 ,423 | 1 ,362 | 1 ,286 | 1 ,286 | 0 | 0 | 0 | 5,357 |
DOORS NORTH SOUTH EAST WEST NE/NW SE/SW TOTAL
AREA 21 | 21 | 0 | 0 | 0 | 0 |42 |
COOLING | 292 | 292 | 0 | 0 | 0 | 0 |585 |
HEATING | 929 | 929 | 0 | 0 | 0 | 0 |1 ,858 |
FLOOR AREA COOLING HEATING
1250 0 | 1 ,290
CEILING AREA COOLING HEATING
1250 19476 | 7,382
MISCELLANEOUS COOLING LOADS
People Sensible Load 900 Latent Load 3, 135
Lights & Appl . Load 0 Latent Safety Btuh 941
Ventilation Load 0
Duct Heat Gain 0
Infiltration Load 556
Sensible Safety Btuh 34484
TOTAL SENSIBLE LOAD 15,097 TOTAL LATENT LOAD 4,076
Summer ACH 0. 15 Temp. Swing Mult. 1 . 00
Total Cooling Load 19, 173 BTUH Or 1 . 60 Tons ***
MISCELLANEOUS HEATING LOADS
Infiltration Load 44167 Ventilation Load 0
Duct Heat Loss 0 Safety Btuh 7,483
Winter ACH 0. 30
Total Heating Load 32,428 BTUH ***
01-01-80
60601903. 15
SUMMARY REPORT
Prepared For: Prepared By:
RAYMOND JARVIS HJC
110 BROOK ST KASDEN FUEL CO
SOUTH WINDSOR , CT 06074 Job Name: JARVIS
DESIGN CONDITIONS for SOUTH WINDSOR
OUTDOOR INDOOR
SUMMER WINTER SUMMER WINTER
Dry Bulb 95 5 75 70
Wet Bulb 75 62
Daily Range 21 Daily Swing 3. 0
Latitude 40 Elevation 300
Safety Factor (%) 30
Latent Factor (%) 27
Sensible
Room Heating Heating Cooling Cooling
Name BTUH CFM BTUH CFM
WHOLE HOUSE 329428 454 15,097 762
32,428 454 151097 762
HEATING DELTA T 65. 0 COOLING DELTA T 18. 0
NOTE: *** Calculated Airflow is based upon load requirements.
Verify that airflow calculated is compatible with
selected equipment requirements. ***