HomeMy WebLinkAbout11 Aroda DriveDEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
Application is hereby:TOWN OF SOUTH WINDSOR PERMIT#
rBUILDINGDEPARTMENT 7 G
APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#644-2511 ext. 23041-Aha Building Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
r Aradn,ve-
0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT HIPOINT HEATING do COOLING,MM
APPLICANT ADDRESS SOUIIi VIfINDSOR, 06074
p
APPLICANT PHONE# o /I ' 0/8/
OW N 3 OWNER Etnie_
rimq< OWNER ADDRESS Aj^p d A,
0) OWNER PHONE (0q-lu - Iq
C ESTIMATED COST 00
U
IS THIS A CONTRACT COST? X Yes No
FEE ENCLOSED$
TYPE OF JOB:
SOR•CD New Installation
Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
Ll HEATING RESIDENTIAL
C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUTBTUH) NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
OIL--GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY
GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE el OF INSIDE 75"°F DIFFERENCE 26 OF
TOTAL HEAT GAIN(BTUH)2,5 HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQ PMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. TYPE TATE
SIGNATURE OF APPLICANT DATE
5 `J y
HVAC LOAD ANALYSIS
for
Ernie Hintz
11 ArodaDr
South Windsor CT 06074
RESIDENTIAL AND LIGHT
COMMERCIAL HYAC LOADS
Prepared By:
Steven Clark
Hipoint Heating&Cooling
71 Edwin Road
South Windsor,CT 06074
860)291-0181
3-13-02
RHVAC-Residential&Light C mmercial HVAC Loads Program Elko Software Devel pment,Inc.
CR nair
c)fhnge,CT 06477-3601 3-13-02 Page 2
Project Summary
Project:Company: Hipoint Heating&Cooling
Client: Ernie Hintz Representative: Steven Clark
Address: 11 ArodaDr Address: 71 Edwin Road
City: South Windsor CT 06074 City: South Windsor, CT 06074
Phone: Phone:860)291-0181
Fax: Fax: 860)291-0020
Comment: E-Mail hipointcooling@aol.com
Design Data
Project Name:
Reference City: Hartford, Connecticut
Daily Temperature Range: Medium
Latitude: 41 Degrees
Elevation: 19 Feet
Elevation Sensible Adj. Factor:1.000
Elevation Total Adj. Factor: 1.000
El vation H ating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference
Winter: 7 N/A N/A 72 N/A
Summer: 88 73 50% 75 33
Check Figures
Total Building Supply CFM: 933 CFM per square foot: 0.733
Square feet of room area: 1,274 Square feet per ton: 573.728
Building Loads
Total h ating required with outside air: 49,357 Btuh 49.357 MBH
Total sensible gain:20,518 Btuh 80 %
Total latent gain: 5,222 Btuh 20 %
Total cooling required with outside air: 25,740 Btuh 2.145 Tons(based on sensible+ latent)
2.221 Tons(based on 77%sensible capacity)
N tes
Calculations are based on 7th edition of ACCA Manual J.
All comput d results are estimates as building use and weather may vary.
Be sure to s lect a unit that meets both sensible and latent loads.
Thursday,May 29,2003
RHVAC-Residential&Light C mmercial HVAC Loads Program
Connair Elite Software DeveDevelopmentDevelopmentInc.
Orange,CT 06477-3601 3-13-02 Page 3
Miscellaneous Project Data
Project File Name: UNTITLED
Syst m Input Data
Outdoor Outdoor Indoor Indoor Grains
System 1-- Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference
Winter: 7 N/A N/A 72 N/A
Summer: 88 73 50% 75 33
Ext real Overhangs
No. Projection Offset No. Projection Offset
1 3 1 6 0 0
2 5 0 7 0 0
3 4 0.5 8 0 0
4 0 0 9 0 0
5 0 0 10 0 0
Duct Sizing Inputs
Runouts Main TrunkDuctMaterial:Galvanized Steel Galvanized SteelRoughnssFactor: 0.000300 0.000300PressureDrop: 0.1000 In.wg/100 Ft. 0.1000 In.wg/100 Ft.Minimum Velocity:450.0 Ft./Minute 650.0 Ft./MinuteMaximumVelocity: 750.0 Ft./Minute 900.0 Ft./MinuteMinimumHeight: 0 Inches 0 Inches
Maximum H ight: 0 Inches 0 Inches
Outside Air Data
Winter Summer
Infiltration: 0.900 AC/Hr 0.400 AC/Hr
Volume of Conditioned Space: X 10192 Cu.Ft.X 10192 Cu.Ft.
9,173 Cu.Ft./Hr 4,077 Cu.Ft./Hr
X 0.0167 X 0.0167
Total Building Infiltration:152.88 CFM 67.94667 CFM
Total Building Ventilation: 0 CFM 0 CFM
System I—
Infiltration&Ventilation Sensible Gain Multiplier: 14.29 = (1.10 X 1.00 X 13.00 Summer Temp. Difference)Infiltration&Ventilation Latent Gain Multiplier: 22.68 = (0.68 X 1.00 X 33.38 Grains Difference)
Infiltration&Ventilation Sensible Loss Multiplier: 71.45 = (1.10 X 1.00 X 65.00 Winter Temp. Difference)
Thursday,May 29,2003
Residential&Light C mmercial HVAC Loads Program
onnairElite Software Development,Inc.
range,CT 06477-3601 3-13-02
Page 4
R:
OHVACtalBuilding Summary Loads
Compon nt
Description Area Sen. Lat. Sen. TotalQuanLossGainGainGain1AWindowClearGlassWoodFrame744,762 0 2,634 2,634ICWindowClearGlassMetalFrame564,206 0 3,412 3,41210DDoorWoodSolidCore361,076 0 274 27412CWallR-11 + 1/2"Gypsum(R-0.5) 1154 6,750 0 1,723 1,72316DCeilingR-19 Insulation 1,274 4,387 0 2,498 2,49819FFloorOverBasement/Encl Crawl Carpet No Insulation 1,274 9,026 0 0 0Subtotalsforstructure:3,868 30,207 0 10,541 10,541ActivePeople: 16 0 3,680 4,800 8,480InactivePeople: 0 0 0 0 0Appliancs: 0 0Lighting: 0 1,200 1,200
Ductwork: 0 0 0 0 008,227 0 3,006 3,006Infiltration: Winter CFM: 152.9, Summer CFM: 67.9 166 10,923 1,542 971 2,513Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0SrisibleGainTotal:
Temperature Swing Multiplier: 20,518
X1 00BuildingLoadTotals.49,357 5,222 20,518 259740
Check Figures
Total Building Supply CFM: 933 CFM per square foot: 0.733Squarefeetofroomarea: 1,274 Square feet per ton: 573.728
Building Loads
Total h ating required with outside air: 49,357 Btuh 49.357 MBHTotalsensiblegain: 20,518 Btuh 80Totallatentgain: 5,222 Btuh 20Totalcoolingrequiredwithoutsideair. 25,740 Btuh 2.145 Tons(based on sensible+latent)
2.221 Tons(based on 77%sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.Be sure to s lect a unit that meets both sensible and latent loads.
Thursday,May 29,2003
RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software DevelpConnair prr eM,Inc.
Orange,CT 06477-3601 3-13-02 Pag 5
System#1 Summary Load
Component Area Sen. Lat. Sen. TotalDescriptionQuanLossGainGainGain1AWindowClearGlassWoodFrame744,762 0 2,634 2,634ICWindowClearGlassMetalFrame564,206 0 3,412 3,41210DDoorWoodSolidCore361,076 0 274 27412CWallR-11 + 1/2"Gypsum(R-0.5) 1,154 6,750 0 1,723 1,72316DCeilingR-19 Insulation 1,274 4,387 0 2,498 2,49819FFloorOverBasement/Encl Crawl Carpet No Insulation 1,274 9,026 0 0 0Subtotalsforstructure:3,868 30,207 0 10,541 10,541ActivePeople: 16 0 3,680 4,800 8,480InactivePeople: 0 0 0 0 0Appliances: 0 0 0 1,200 1,200Lighting: 0 0 0 0 0Ductwork: 0 8,227 0 3,006 3,006Infiltration: Winter CFM: 152.9, Summer CFM: 67.9 166 10,923 1,542 971 2,513Vntilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0SnsibleGainTotal:
20,518TmperatureSwingMultiplier: X1 00SystmLoadTotals:49,357 5,222 20,518 25,740
Ch ck Figures
Supply CFM: 933 CFM per square foot: 0.733Squarefeetofroomarea: 1,274 Square feet per ton: 573.728
System Loads
Total heating required with outside air: 49,357 Btuh 49.357 MBHTotalsnsiblegain: 20,518 Btuh 80 %Total latent gain: 5,222 Btuh 20Totalcoolingrequiredwithoutsideair: 25,740 Btuh 2.145 Tons(based on sensible+latent)
2.221 Tons(based on 77%sensible capacity)
Not
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.B sure to select a unit that meets both sensible and latent loads.
Thursday,May 29,2003
RHVAC-Resid ntlal&Light C mmercial HVAC Loads Program Elite Software Development,Inc.
Connair q
Orghge,CT 06477-3601 3-13-02 Page 6
Syst m#1 Zon #1 Summary Loads
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
1A Window Clear Glass Wood Frame 74 4,762 0 2,634 2,634
1 C Window Clear Glass Metal Frame 56 4,206 0 3,412 3,412
10D Door Wood Solid Core 36 1,076 0 274 274
12C Wall R-11 + 1/2"Gypsum(R-0.5) 1,154 6,750 0 1,723 1,723
16D Ceiling R-19 Insulation 1,274 4,387 0 2,498 2,498
19F Floor Over Basement/Encl Crawl Carpet No Insulation 1,274 9,026 0 0 0
Subtotals for structure:3,868 30,207 0 10,541 10,541
Activ Peopl : 16 0 3,680 4,800 8,480
Inactive People: 0 0 0 0 0
Applianc s: 0 0 0 1,200 1,200
Lighting: 0 0 0 0 0
Ductwork: 0 8,227 0 3,006 3,006
Infiltration: Winter CFM: 152.9, Summer CFM: 67.9 166 10,923 1,542 971 2,513
V ntilation: Winter CFM: 0.0, Summer CFM: 0.0 0 n/a n/a n/a n/a
S risible Gain Total: 20,518
Temperature Swing Multiplier: X1.00
Zone Load Totals: 49,357 5,222 20,518 25,740
Check Figures
Supply CFM: 933 CFM per square foot: 0.733
Square feet of room area: 1,274 Square feet per ton: 573.728
Zon Loads
Total heating required with outside air: 49,357 Btuh 49.357 MBH
Totals nsible gain: 20,518 Btuh 80 %
Total latent gain: 5,222 Btuh 20 %
Total cooling required with outside air: 25,740 Btuh 2.145 Tons(based on sensible+latent)
2.221 Tons(based on 77%sensible capacity)
Thursday,May 29,2003