Loading...
HomeMy WebLinkAbout11 Aroda Drive (5)PE MIT # Application For 3044 2 2 DEPARTMENT DECISIONcdHeatingPermit 3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS N +'APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR o cd 6-22-64 .: 00 a) DATE CW INSPECTOR- APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O c 1. LOCATION OF JOB 7 11, 0 I~4, cd >.., NO. STREET 4 0 cd a) ma) LOT NO. FLOOR APT. NO. O N a) a> 0 2. OWNER 4071 S O00 s. ADDRESSbo4G ` /s r. Na)a:/ 1'C Slj 4.PHONE m D dr//lTiri/ /U2 S. APPLICANTS, vi ca O w e. ADDRESS rO 1-4u`di x" J/1 7.PHONE 6v4I/ 3/— 0 '0 S. LICENSE N0. y0 wO 9. EXPIRATION DATE OF LICENSE v a 10. ESTIMATED COST s 4J o IS THIS A CONTRACT COST?L<J'YES NO y 12. FEE ENCLOSED S Permit #4797 a> 0U aa) 13. TYP OF ILDING: rA RESIDENTIAL COMMERCIAL 14. TYPE OF JOB: INDUSTRIAL cd 3 O IIGI ALTERATION STALLALLATION ADDITION REPAIR 1 1 APPLICATION FOR HEATING PERMIT (c ntinued from Reverse Side) 11. LOCATION OF JOB Z TO- _Nt 3 zy"/ , 12. TYPE OF INSTALLATION: NO OIL BURNER STR T HEATING SYSTEM VENTILATIONFLOOR SPRINKLER 1 GAS BURNER STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIR NG RATE BOILER OR FURNACE MAKE AND NO. S B.T.U. OR SQ. FT. NET a B.T.U. OR SQ. FT. GROSSRING RATE % FLOORS TO BE HEATED NEW OR l tTY BUILDING &f uJ INSULATED - YES OR Ner- 4 TYPE OF WALL LJBod 4rd mr INSULATION /W_& 1 ROOF OR CEILING J'S INSULATION lAVG. SYSTEM WATER TEMP. 20 B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE a- SU FAHRENHEIT MAKE OF RADIATION: BASEBOARD, COPPER CONVECTORS,ORR.C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U.— fp `g. ' O C) 1 u .- `(- / DESCRIPTION OF WORK 15715. TO BE DONE: 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS). Ow E.T.U• e.T.U.DISTRIBUTION INSTALLEDC ROOM SIZE ,.,wINDND DOOsRS AREA - SQUARE FEET VOLUME t)< TOTAL TOTALTOTAL in ROOM NO.GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT A•F CORRECTED J j LL 4 RAD. REGISTER L Tw -AND S: TEMP. n TO?' F f TYPE AND SIZE OR LEADER SIZE < WALL f'GtG INFILT.) DIFF. F O m N SQ. FT. FREE AREA h1 3 alc) G. // p 911)J 0c> 0 0 tiD 1 7Gv (r a y yv 3 L /r4 o vr ort> erv-J b-m oc /QZ is f rr• ' l o -D v syo 4 erD % C 2 TOTALS A. HEAT LOSS FROM BUILDING S B.T.U./HR. B. DOMESTIC HOT WATER DEMAND Z B.T.U./HR. C. PIPING, OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND 16. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. DATE y SIGNATURE OF APPLICANT