Loading...
HomeMy WebLinkAbout1060 Avery Street (3)PUBLIC HEARING - Legal Notice Attached 1 . Application of Robert C . Hatch , for a one lot resubdivision at g1 the southwest corner of property located on the east side of O Avery Street , south of Country View Drive , as shown on a plan 1 prepared by Page Engineering , Inc . , dated 3-29-85 , Project 85-021 , RR zone . Mr . Hatch was present and explained that he owns 16 acres and is proposing to break off one acre for a lot . No zoning variances are being requested , and Mr . Hatch said he has followed all the regulations . Assistant Town Planner Michele Rowley reported as follows : This one lot subdivision is located on the east side of Avery Street near Country View Drive in an RR zone . The lot will be hooked up to the sewer and water is available . There will be a turn-around driveway , and no wetlands are on the property . A conservation plan is not needed for disturbance of less than 1/2 acre . If approved the plan will need the following modifications : Arrows indicating sewers and drainage , and the acreage of the property should be shown on the key map ; the foliage line should be indicated if the site is wooded (or it should be noted if it is not wooded) ; the building line for lot 2 should be shown coincident with the right-of-way . A notation should be added that there are no regulated wetlands on the site . Town Engineer Martel .reported that his only comment is that iron pins should be placed on all the corners of lot #2 . se,` e a 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 R.Co a AREA CODE 203 644-2511hpso March 10 , 1987 Mr. Robert C. Hatch 1080 Avery Street South Windsor, CT 06074 RE: App. #1229 - 1 Lot Subdivision Dear Mr. Hatch: Please be advised that the Planning & Zoning Commission voted on March 3, 1987 , to approve the above application for a 1-Lot resubdivision for the southwest corner of your property at 1080 Avery Street, as shown on a plan prepared by Page Engineering, Inc. dated 3/29/85 , subject to the following: 1. The plan shall be modified as follows: a. The key map shall indicate the direction of sanitary sewer and storm drainage flow, and the total acreage of the property. b. A foliage line should be shown; if the site is not wooded this should be noted on the plan. c. The building line for Lot 2 should be shown coin- cident with the utility right-of-way. d. A note that there are no regulated wetlands should be added. e. Iron pins must be placed at all property corners on Lot 2. f. The data table should reflect actual lot measurements in the "provided" column. 2. Water shall be supplied to Lot 2 by the Connecticut Water Company. 3. Lot 2 must be connected to the sanitary sewer system and is subject to the approval of the Water Pollution Control Authority. 4. A drainage assessment fee of $50 .00 shall be submitted to this Commission. Mr. Robert C. Hatch Page 2 . RE: App. #1229 - 1-Lot Subdivision 5. Footing drains will be required. Prior to the building of any structure on the lot, a topographic map drawn to a scale of 1" = 401 , shall be submitted showing proposed contours, elevations and the location of the footing drains. No build- ing permit will be issued until the proposed contours, floor elevations and location of footing drains have been approved by the Town Engineer. 6. No building permits will be issued until all the conditions of approval have been complied with and the final plans have been filed in the office of the Town Clerk. A black and white transparent mylar, together with two blueprint copies of the plan, must be submitted to this Commission to be stamped and signed. This letter of approval must be reproduced on the plan. After the mylars are signed, they will be returned to you and must be filed in the Town Clerk' s office within 90 days. Very truly yours , PLANNING & ZONING COMMISSION By: Louise C. Evans, Chairman CC: Richard P. Martel, Town Engineer Marcia A. Banach, Director of Planning Thomas D'Auria, Buildinq Official E. Belleville, Assessor WPCA 1cw M a t r 074es d&"41at w 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 OgOR,Cpe AREA CODE 203/644-2511 April 12 , 1988 Mr . & Mrs . Mario Burgio 133 Cromwell Street Hartford, Connecticut 06114 Dear Mr . & Mrs . Burgio : u ':4fl At a regular meeting of the Water Pollution Control Authority held on April 5 , 1988, the Authority voted to ap_prove__th'e sewering of the two lot subdivision on Avery Street - +C 1 ,? as shown on a map dated 3/29/85 - revised 3/19/87 - Project 85021 - Page Engineering - subject to the following conditions : 1 . The technical approval of the Town Staff is given . 2 . This approval letter is affixed to the final set of mylars and filed with the Town of South Windsor. Very truly yours , Michael Lanza, Chai/marn TOWN OF SOUTH WINDSOR Water Pollution Control Authority ML: pm CC : A. Bowen Davies , Deputy Town Engineer Thomas P . D 'Auria , Chief Building Inspector Raymond Hallowell , Chairman , Planning & Zoning Marcia Banach , Director of Planning