Loading...
HomeMy WebLinkAbout102 Kebalo LaneBectric#7 4/3,1, APPLICATION FOR BUILDING PERMIT Plumbing# (OSO to 102 Keba to Lane HVAC #11173 27878 Date: 17-May-01 Sprinkler# NO' 4Aff' A ALS Estimated Cost 74,500.00 r 46( COMPLETE RED BOXED AREAS Permit Fee ing TYPE OR PRWT ONLY Occupancy Fee SIGN ON REVERSE SIDE APpr.for CO.Total Fee TO BULDWK'DEPARTMENT,TOWN OF SOUTH WNDSOR,CT Additional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location i n2 Kahan i sine Eta1Lot No. A Side of Street left Zone SRD Applicant K F Paniff es LLC Walter Kebab. Manager Tel# 860-648-4446 Addr ss 175 Wheeler Road, South Windsor Zip 06074 Lic.# 3065 Own r KF_ P LLC Address175 Wheeler Road, South Windsor(FNA 176 Smith Street) Architect GregM Louis Montana Asso.Address 35 Alpine Drive, South Windsor Sq.Ft.New Area: 1st FL 1057 2nd Fl 343 3rd FL 0 Total New Area 1400 Rooms 5 Lavatories 1 Bathrooms Z Garages 1 Purpose of this permit: Build condominium unit per puns and specifications Unit type D Located on the comer of Smith Street and Wheeler Road City Watet t Well Septic System SewerXXX Ins. H.O. S.P. Cert. Area NUO Basement /C-S 7 Garage 3.2Y Approved by Date 5 3-( Use Group F'3 Construction Type 5 B Rw'sed 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in Pthis building and4ts Use is allowed Signed9.&Ct/ 4"-V-4—vAWZ I hereby apply for a Certificate of Occ p ncy for the wok a ribed in this application for the permit Signed Ja//R DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS T. cation of Job:AFFIDAVIT Additional Fee$ — 0 — State of Connecticut ss.South Windsor County o Hartford Q Q Owner I of 754Z Agent for the building erected Contractor under Permit No. 27878 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorizer jtqdersaid permi d' n exceed the submitted estimated cost Signed j" Subscribed and sworn to before me this day of A.D.20 Estimated Cost S 89440 Difference: $ (1 ,6 9 8) Notary Public r Inspection / Approval Date By Appl Code Description Due Whom Code Comment 27878-B 74,500 BO1 FOOTING 05/29/01 JFF A WITH CONTRACTOR KEBALO BROS 3000 CONTRACT P03 ROUGH 08/22/01 CJD A W/PLUMBER-H20 AND DWV B03 FRAMING (ROUGH) 09/24/01 CJD A W/KEBALO- E03 ROUGH 09/24/01 CJD A W/KEBALO-PROTECT WIRE AT SCUTTLE HOLE, LIGHT AND ACTIVATION FOR ATTIC SPACE B04 INSULATION 10/01/01 GRM A W/CONTRACTOR E01 SERVICE 12/11/01 CJD A W/WALTER B10 FINAL 12/12/01 JFF A WITH CONTRACTOR B10 FINAL 12/13/01 JFF A CLOSED OUT. 11173-H 5,940 10806-P 5,500 17432-E 3;500 1 Inspection / Approval Date By Appl Code Description Due Whom Code Comment 27878-B 74,500 BO1 FOOTING 05/29/01 JFF A WITH CONTRACTOR KEBALO BROS 3000 CONTRACT P03 ROUGH 08/22/01 CJD A W/PLUMBER-H20 AND DWV B03 FRAMING (ROUGH) 09/24/01 CJD A W/KEBALO- E03 ROUGH 09/24/01 CJD A W/KEBALO-PROTECT WIRE AT SCUTTLE HOLE, LIGHT AND ACTIVATION FOR ATTIC SPACE B04 INSULATION 10/01/01 GRM A W/CONTRACTOR PO4 GAS TEST 10/24/01 CJD A W/PLUMB. E01 SERVICE 12/11/01 CJD A W/WALTER 11173-H 5,940 10806-P 5,500 17432-E 3,500 Total Est Value 89,440 Dwelling 1,400 67,592.00 Basement 1,057 15,009.40 Garage 325 4,615.00 Smoke Det 7 525.00 BOCA Value 87,741.40 Difference 1,698.60) J SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNEC TIICUT 102 KEBALO LANE LOT_# Reviewed By ring) K.F. PROPERTIES Date Reviewed Z/iz,/U1 Approv enied 175 WHEELER ROAD,SOUTH WINDSOR,CT Reviewed By Planning) BP_#_27878_ Ph #_648-4446 Date Reviewed Approved/Denied Date Submitted 00/00/00 FOR C of O ***** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan J 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain c. electrical & telephone J d. water ae. other Z 5. Sewer connection charge paid 6. Appropriate certification 7. Bonding Z- 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. 72 1 Pavement Excavation No. COMMENTS: Rjee !® DEC 12 200, SOUTH WINDSOR PLANNfNG DEPT, DEPARTMENT DECISION APPLICATION FOR ELECTRICALPERMIT#PERMIT Application is hereby:TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPRO 1540 SULLIVAN AVENUE rQ7 7 644-2511 ext.230 Dauftg r Application must be printed orppP Location ofjob 102 Kebalo Lane "Wheelers'Estatee' Street No.. Street Lot No.' FEE SC EDUIE '-e • f Floor No. 0 - $19000 - $12.00 Over s1,000 12.00 per$1,000 OAR KF Properties LLC or any fraction thereof ADDRESS 175 Wheeler Road South Windsor, CT 06074 OWNERS PHONE# 644-5124 648-4446 APPLICANT Kebalo Electric Co. Inc. Walter Kebalo S ADDRESS 175 'Wheeler Road i 1 c Fq South Windsor, CT. 06074 x jFt !: -- '_•- iyif a_ _ - _ •'j.f G 4 i _ f 3,ESTMATED COST 500 f, is THIS A orrrRA T COST YES Na s C FEE ENCLOSED, OR CO TYPE OF JOB: - Original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILD_ IS THIS APPLICATION ASSOCIATED WITH A X RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP Other please specify) mwmw TYPE OF INSTALLATION/WIRING METHOD Type NMB SIZE OF MAIN FEEDERS AND RATING OF.WIRE USED #3 copper 100 amp NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS 1 100amp NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED?1%/NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 11 NUMBER OF SWITCHES 2 4 NUMBER OF OUTLETS 3 0 NUMBER OF LIGHT FLX7URES 2 6 7 NUMBER OF HEAT CIRCUITS 0 NUMBER OF A/C CIRCUITS 1 SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Wire new condo units Approx 1400 sq, ft. , or less Including new 100 amp underground service THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CT 104943 E1 t 1tSw NAME STATE LICENSE NO. TYPE SIGNATORE OF APPLICANT PHONE NO. 644—512 4 DATE DPAITMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# lication is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Bu' in Inspector Application must be printed or typed Loca' n of Job: `' FEE SCHEDULE 102,C:../0, P 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT C' c APPLICANT ADDRESS 42- A,Amo A,// APPLICANT PHONE# W N S OWNER001Oeq< OWNER ADDRESS e IS 444f-,F, OWNER PHONE C ESTIMATED COST$ r IS THIS A CONTRACT CQST? n 0Yes 0 No J FEE ENCLOSED$ TYPE OF JOB: soR,co New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL I BUILDING PERMIT APPLICATION? YES NO BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE ZC NO.URINALS G STYLE NO.OF BATHTUBS It NO.OF SHOWERS NO.OF LAVATORIES f NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK 6-711 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOILMANC,E OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE lo K if 6Q(U L a lt e Location of Job: 6 urld<,.1 cv4de) 6 0-$1,000=$13.00 Street No. Stree Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT G&"EVj,,LEJ= /1A&,b414A1 i C P4 L Qt U i'c-6 1''U C-, APPLICANT ADDRESS 1p,Q . A 02e-, 10&V EAZ ICi<e L_0 3 APPLICANT PHONE# 86(. - 76 3 OWN S OWNER 14, r—, Pie 0 T L C..(Pc0. .•-e S L q OWNER ADDRESS N 'T( .'7 2e c,T— OWNER PHONE C ESTIMATED COST$ IS THIS A CONTRACT COST? Ves 0 No ICJ FEE ENCLOSED$ S TYPE;? ew SCR CD Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF S STEM: TYPE OF B DING: ATING LrRESIDENTIAL q A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESS LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC QX RM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 1K sTA-Ly4Tiuf4 aC= AW.e ems, [r49s r.2eJ P-O-L A/L s' Ve4-1 W i'T'4- rev4T-Ai4 L Al s-1uAAJaCe m W -fi-&9,0 -6 7 GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) y l tT a L *f vim - IJ-,C-.&41 AA/iv YZA 0,36 TONNAGE 3 COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) c L S TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3 tg 3 2 Y,L, 9- 1 cr. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT Q, DATE Z O RIGHT-J SHORT FORM Entire House Fahrenheit M chanical S rvices Job: 09-17-2001 7 Moody Road,Enfield,CT Phone:1-860-763-5775 Fax:1-880-763-5844 Project • For: Wheeler Estates Sr. ON&Y Lk*, Kebalo Lane, South Windsor, CT Design Information Htg Clg Infiltration Outside db(OF)5 97 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD(OF)75 22 Fireplaces 0 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 37 HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM AIR CON Make RHEEM MANUFAC Trade Rheem Trade Rheem RAKA Series RGRA-04(E,N)MAES RAKA-037JA RCBA-3765 Efficiency 93.5 AFUE Efficiency 10.0 SEER Heating input 45000 Btuh Sensible cooling 24780 Btuh Heating output 42000 Btuh Latent cooling 10620 Btuh Heating temperature rise 34 OF Total cooling 35400 Btuh Actual heating fan 1138 cfm Actual cooling fan 1138 cfm Heating air flow factor 0.035 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space th rmostat Load sensible heat ratio 88 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2) Btuh) Btuh) cfm) cfm) Foyer 108 3292 841 114 45 Kitch n 210 5185 4420 179 236 Brfst/Dining 149 5484 3765 190 201 Master Bath 66 969 479 34 26 Master Bedroom 233 5661 3631 196 194 Master W. I. C. 39 173 59 6 3 Spare B droom 226 5609 3599 194 192 Bath 88 1327 639 46 34 Living Room 192 5188 3855 180 206 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrightsoft Right-Suite ResidentialTM 5.0.28 RSR25708 2001-Sep-1717:25:15 CAFahmeo-Wheeler Sr.Res.B-UnR.rsr Page 1 Entire House p 1310 32888 21288 1138 1138 Ventilation air 0 0 Equip. @ 1.02 RSM 21714 Latent cooling 2773 TOTALS 1310 32888 24487 1138 1138 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. A. writghtsoft Right-Suite R sidential^"5.0.28 RSR25708 2001-Sep-17 17:25:15 CAFahmec-Wheeler Sr.Res.B-Unit.rsr Page 2