HomeMy WebLinkAbout102 Bridlewood Road (4)DEPARTMENT DECISION PT
APPLICATION FOR HVAC PERMIT A
Application is hereby: TOWN of SOUTH WINDSOR
BUILDING DEPARTMENT Bldg Perm #
15-10 SULLIVAN AVENUEPER0O ?
644-2511 ext. 230
Date Building Inspector Application must be printed or typed
Location of job
I0 A t `J L WerAS 2 e
Street No. Street Lot No.
FEE SCHEDULE
Floor Apt. No.
0 - $1,000 - $12.00
Over $1,000
12.00 per$1,000 OWNER U G
or any fraction thereof
ADDRESS I,L 7 5'
OWNERS PHONE#4 4 -
APPLICANT S C H yG- t-
W S ADDRESSAt
ESTIMATED COST $ Oc Cam!
C IS THIS A CONTRACT COST?
YES NO
C FEE ENCLOSED $
OR-Co. .. .:: TYPE OF JOB:
Ci Original Installation
Alteration/Addition/Repair
x Revised 11/95
APPLICATION FOR HVAC PERMIT(Continued from reverse side)
TYPE OF SYSTEM TYPE OF BUILDING
HEATING RESIDENTIAL
A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONA RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE O F INSIDE F DIFFERENCE F
TOTAL HEAT LOSS(BTUH) 1—
HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.)
0 A2L
GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH)
TYPE OF FUEL
OIL-GPM GAS-INPUT ELECTRIC-KW
OIL TANK SIZE&LOCATION
INSIDE OUTSIDE CAPACITY)%'7,1 LPG TANK CAPACITY
AIR CONDITIONING
DESIGN TEMP. OUTSIDE C70 F INSIDE_71—F DIFFERENCE__Z4j F
TOTAL HEAT GAIN(BTUH) -5-4,J c,v
HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.)
L.P A."C I _r S6.I AFA L
TONNAGE Jr'COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK L 1ti/c- ` C./i9 AAI\ /._
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
STATE LICENSE-NO. NAME&TYPE SIGNATURE OF APPLICANT
PHONE NO. rj-,J-DATE IcLI,,
t
S
JOB NO....,.
a .. 7'Form No.IdD-611•ai12)5.18-162 LENNILY'r HEATING DATA SHEET 7s
DATE...P_.
OUTSIDE DESIGN TEMP.._-d__-
HEATING CONTItACTO Co. t'/'- "l.-Q`1< ADDRESS 2X ,',°y^`
INSIDE DESIGN TEMP....-... _.___
DESIGN TEMP. DIFF.. _d
NAME OF JOB -G=c.Y ADDRESS b 5= -- _-
9.
I. Room Use and Boor Level 1. j,2. F , 3. 4. ,`., S. v- 6• •i''(L 7' 11Y/` .,a8•
2. Room length and Width
3. Running Ft f Esrposed Wall 7911,
4. C fling Heigh if 3
Area Area Area Area
Area Area Area Area Area
CrackS. Exposure Table "l1" Multi- Crack stub Crack stub Crack stub Crack stub Crack stub Crack stub Crack stub Crack Stuh Awh
lio. Factor plier Cfm Loss Cfm Loss Cfm Loss L isTypeCfmLossCfmLouCfmLossCfmLossCfmLossCfm
Gr sf 7 tit•
t•
7 +1$ J •fKl Cr;!• it t r 'j`!
r 7 _.
1 t f i.. t;f • ` r
6. E:posad w 4,,: l-:•';/' iC:LI! et}`e y1'Y.], t1i.Wall rf' t:+C k'a k. +i, Da' .: a e!??'s rs
14 S oG S'Z o 8'c 7.-0 01 1
Wind ws
7. end
D rs 1••G lc>
Not 7cl L 141. o j- a 3 8'° a, 7 I Z
8. I=p sod
Wall
9. C Id
Partiti n
10. Cold 3 So Fs 40 l L 1 3 3
Coiling
11. Cold
FI r
0 4r SG a y11 ita 2
Infiltration,
12. (L akage)
or Q(j
Air Change
13. Room SubT tal Btuh S— 410
14. Btuh Adjustewnt
is. Room Total Bteh
I& Cfm(gl Tomp.Rise
17. Adjusted An
LENNOX Equip- BlowBlower Motor hp Construction Los
Stub (Input-Ovtpat), 'C — /L c¢ Cfm Driv Ventilati n L ss
Fuel S.P Rpm Total L ss
t
n,
R _
t;,,
a '
rA
s:•
9.'
n»-,
f
F „'
d
yi .,
I,
011
dL
SuO
WIV
77-
rat
v. ., •
w ;' , ,
fib: ; ':
aTr
1,`
ti +
1i$
t
f
if,
s ,
w
17
did`
t•',;
t
a.
fK'
S ,
7'
at •. ,
L,'•
iY
k
k
S
ArT '
a`
ySr
ITS<
i
j> ,
R
rR .
ct :
CA ;(,
y
S•
1t ,
e,.
r
r - ,•
d
i ':
a
Y`\
r
any'"+ ',
of }
tee`
r
k}X:
t ,
k`,
i
aj
J
1
r • ''{,
MIN.
g ,
fi'
i ^
S
yS' .
s`,
ktl5+l;?
b`
r
Ott{' (
tt >,
lit
x. •&..
h,
i
W.,
f
r{
d9v
F %. :
k
i
Apt .
phi .] ,`.
Tf
Y ,`
t,•
Y,
1Z
Iwv
v
e!g,' »+
fay,
K '+
7
Ai
Zr` "
7`.
I +
i't'
q .
t•d
y,
s .' €
f
ti }
i
LLi=•;' }
Q;
a
5+
err-
f ';
rv,,
fi. ,
a
i.
s -
AA.-
9,
1t
1, +..
wit, .+:
T
r'
F
fns:
S
t -
w^,
p.
s
t? ' , ' `•,!
w '
a
y.',
mot''
zt'• _
r .
T . - `
i4 .'
y^ . {,`"-,+
q` -•
n•
r'
a
i, '
y
Y
z
r +. ,
M•' /.>
kk +`
Yk
s,
n,`" .
r
a.
8a
4 .
9Y
I
i •
Ip' `
4` ,
d
4
yip
r•;
I•• `"`
S+
t
r3
i,
A•'
L+.
Sr
ow
S
xi,`.
was• .:
0
Y
Y
r
A4cr` .
N, * `
a . >; ', .
t
r. ' =
4
j" '
i
v }
r, :
z:*
IY.J:
14
rh ;
rP.,` _,
r .
may
y,."%_
S- '
ar •. .,
1'
f,'
ti.£` •+
A
VFn
s..
v (` .
e .) '
it
f ;.`- ` ,
r
3e
Y )
e; '';
j•
P,;
w".-
9•,
A;
w:+
T "•
i
i
a
titer. .' .
r+
Y
t
w;,;
tin {+ ?
ikr _
r
3:'
r `
2 #
d' > •
e
t ',-
n *
r
d ,
y
a ; `` ,,
R-'
L
r
P
f
N.
r
c=
ar*.
Mt,.
5 .
e;
i
L,.
0
exmY§
d •,„,..
a
z"
k
C..
li,
r ^
f"
r:'
y ^.
r3', , ,
m`„j,
3 >
vt.+
T
a
i}
yiX
3i +'
r
Nit.
t
14 -
if
i_
ae •
oA
C.
1
oY
rt4•
r
Js
a '
P
x,
a"
F•{
l
r•'("
E'i
4
e '•
t, '
b
e
1'
h
IL
s,''„-
p`-'
IR • -
i+
C -
ryk?
r,
y" ,
ur
t ".; :_
d ; '
p
r:.
r "
yn,
7
Y =
x.g
A''
t
a%' - + + '
7
i';.
a;
s`
J`°`:''
X" :
3y
t1
1, - .
iaH%,° .
dry,
6i"-'„`'
r''
spF
Oi`:
SL,
dorm N RCD 682-L11 S_16-12-69 Job No. Date L"
LENNI?XRESIDENTIAL COOLING DATA SHEET Outside Design Temp.DB G WB
Inside Design Temp.-2Z-Daiiy Range
C Design Temp.Diff. N Latitude
HEATING CONTRACTOR LD jL ADDRESS t Floor Area B
NAME OF JOB vvt' i _ ADDRESS
1 Room Use and Floor Level j r 1. 2 0 ,/L• 3 4 6 p,
rArea
8.
2.Room Length and Width 4 1, X S 3W lip,
Area Area Area Area Area Area Area
Type and Direction 6f TABLE Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh
Exposure NUMBER HTM or Gain °r Gain °r Gain °
r Gain °f Gain °
r
GainrGain °
r
Gain
No. No No No. No. No.No.
NORTH Exposed Wall Length n.E. 1•".=
OR SHADED) Ceiling Height s "• lr1.
3. Wall and Glass Gross E xposed Wall rev.
Solar& Sq Ft Glass Area LO
Conduction) Net Exposed Wall L
EAST Exposed Wall Length i. _%' Parr=: T
Ceiling Height 1 1, f
4. Wall and Glass Gross E xposed Wall !'s a +'' i' rl' Io4
ISolar& Sq Ft Glass Area 21or I d v 25,00 L +
Conduction) Net Exposed Wall I GO B''
SOUTH Exposed Wall Length t • y
Ceiling Height ti'i•••c% '' t,.. i•r;d, y`i+• v+4ti'.'. * 1;1=•u
5. Wall and Glass Gross Exposed Wall w• i'4:a 3? r•': t
lSolar& Sq Ft Glass Area
Conduction) Net Exposed Wall
WEST Exposed Wall Length . , !' wj; 1;: ® J:'rr r =;J'`
Ceiling Height p :! '+r w•f' V ,JI f' v• . yi
6 Wall and Glass Gross Exposed Wall Y# 4 %'f`•j ` *j %} y xi•i v'
Solar& Sg Ft Glass Area O l O O 7rlO
Conduction) Net Exposed Wall 2.• C i LO
7 W od Doors
8 Warm Partition i f
9.Warm Ceiling
10 Warm Floor
11. Appliances- Kitchen (Sensible)
12 People(Sensible) d 4:47 Z 0 3 vv
13 Outsiae Air or Infiltration (Sensible)1
14 Sub-Total-Sensible y f
15 Duct Allowance 310
16 Total Sensible
17 Total Latent 3 x Tot Sensible c, fy•
18.Total Sensible& Latent ti w -''r•
19 Theoretical cfm t 'r- • • 1z
2 . Delivered cfm s• x
i:.
s
CAP MULTIPLIER For °F Swing) ILENNOX Equip. Stuh Cap. V °F
MIN.EQUIP CAP.SARI Rating Cfm Rpm Alr Changes S/T Rail S.P.
Litho U.S.A.
INN M 1 inororor
Area Area Area
TABLE Btu Btu B U
A fit
MR