HomeMy WebLinkAbout101 Kebalo Laneee.tric# d APPLICATION FOR BUILDING PERi4r
Plumbing# RD)Ck 101 Kebalo Lane
HVAC # 1 l 1 iNt : 174Aay-01
Sprinkler# No. 2 7 8 7 7
FI M A"ROV Estimated Cost $ 77,500•00
Building 3 as COMPLETE RED BOXED AREAS Permit Fee vEngineeringT _u TYPE OR PRNT ONLY Occupancypanty Fee $
Appr.for CO. 11SIGN ON REVERSE S®E
Total Fee s /0/ 2 -TO BUMING WARTM",TOWN OF SOUTH WI DSOR,CT 1Additional Cost) $
The undersigned hereby applies to do work according to the following specifications:
Job Location i ei Kin I s SRO) gtlPlo. A_Side of Street 1=Zone SRD
Applicant_ K_F_ ftpgdes I I C VVMW Kebab Menaoer Tel# 860-648-4446
Addr ss 175 YMOSW Road South WNW Zip 06074 Lit# 3065
Owner_ KF, Prooertaes LLC Address 175 Wheeler Road, South Windsor(FNA 176 Smith ShW)
Architect_Gmwv Louis Montana Aseo.Address_35 Alpine Drive, South Windsor
Sq.Ft.New Area: 1st Fl. 718 2nd Fl. 682 3rd Fl. 0 Total New Area 1400
Rooms 5 Lavatories 1 Bathrooms 2 Garages 1
Purpose of this permit: Build Condominium unit per plans and specifications Unit type E
Looted on the comer of Smith Street and Wheeler Road
City WaterjX Well Septic System Sewer tX
Ins. H.O._ S.P. Cart._ Area 14VJ Basement -7[k* GarageApprovedbysr- Dat lc 6 Group Construction Type
Reeked 1/97
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in whic b ilding and's all
Signed
I hereby apply for a Certificate of Occu y or thedescribed in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
Location of Job:AFFIDAVIT Additional Fee S — 0
State of Connecticut
ss.South Windsor
County of Hartford
Owner
1 of Agent for the building erected
Contractor
under Permit No. 27877 issued by the Building Department of the Town of South Windsor being
duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not
exceed the submitted estimated cost
n
Signed
CSubscribedandsworntobeforemethisdayof /I t_- A.D.206 d-
Estimated Cost S 92r150.
Difference: S (9 , 0 6 6)
Nola Public
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
27877-B 77,500
B01 FOOTING 05/29/01 JFF A WITH CONTRACTOR KEBALO BROS 3000PD
P03 ROUGH 08/22/01 CJD A W/PLUMBER
P03 ROUGH 09/07/01 CJD A DWV AND H2O AIR TESTED OK
B03 FRAMING (ROUGH) 09/24/01 CJD A W/KEBALO
E03 ROUGH 09/24/01 CJD A W/KEBALO
B04 INSULATION 10/01/01 GRM A W/CONTRACTOR
B04 INSULATION 10/01/01 GRM A W/CONTRACTOR
i PO4 GAS TEST 10/24/01 CJD A LEFT TICKET
B10 FINAL 03/13/02 CJD A W/ANDY
B10 FINAL 03/13/02 CJD A CLOSED OUT.
11172-H 5,650
10805-P 5,500
17431-E 3,500
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
27877-B 77,500
BO1 FOOTING 05/29/01 JFF A WITH CONTRACTOR KEBALO BROS 3000PD
P03 ROUGH 08/22/01 CJD A W/PLUMBER
P03 ROUGH 09/07/01 CJD A DWV AND H2O AIR TESTED OK
B03 FRAMING (ROUGH) 09/24/01 CJD A W/KEBALO
E03 ROUGH 09/24/01 CJD A W/KEBALO
B04 INSULATION 10/01/01 GRM A W/CONTRACTOR
B04 INSULATION 10/01/01 GRM A W/CONTRACTOR
PO4 GAS TEST 10/24/01 CJD A LEFT TICKET
B10 FINAL 03/13/02 CJD A W/ANDY
B10 FINAL 03/13/02 CJD A CLOSED OUT.
11172-H 5,650
10805-P 5,500
17431-E 3,500
Total Est Value 92,150
Dwelling 1,400 67,592.00
Basement 718 10,195.60
Garage 336 4,771.20
Smoke Det 7 525.00
BOCA Value 83,083.80
Difference 9,066.20)
r
v -
DEPARTMENT DECISION PLICATION FOR ELECTRICAL PERMIT
PERMIT#
AP
Application is hereby:TOWN of SOUTH WINDSOR
BUILDING DEPARTMENT Bldg Permit#
PR 1540 SULLIVAN AVENUE c2,7 97LJ
644-2511 ext 230 .
Date lding Inspector Application must be printed or typed
Location of job
101 Kebalo Laae "Wheeler Estates-
Street No. Street Lot No.
FEE SCHEDULE
Floor Apt.No.
O - $1,000 - $12.00
Over $1,000
12.00 per$1,000 O KF Properties LLC
or any fraction thereof
ADDRESS 175 Wheeler Road
South Windsor, CT 06074
OWNERS PHONE# 644-5124 648-4446
APPLICANT Kebalo Electric Co. Inc. Walter Kebalo
OW ADDRESS- 175 Wheeler goad
q
South Windsor, CT 06074
ESTIMATED COST s -500
C IS THIS A CONTRACT COST?r,.
YES NO
ICI FEE ENCLOSED $
sOR 0 TYPE OF JOB:
Original Installation
Alteration/Addition/Repair
Revised IIM
APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side)
TYPE OF BUILDING
IS THIS APPLICATION ASSOCIATED WITH A
X RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO
BUSINESS
ASSEMBLY CURRENT USE AND OCCUPANCY
MERCANTILE
EDUCATIONAL FUTURE USE AND OCCUPANCY
INSTITUTIONAL
FACTORY
STORAGE ENGINEER'S NAME PHONE
GARAGE
MIXED USE ADDRESS
CITY STATE ZIP
Other please specify)
TYPE OF INSTALLATION/WIRING METHOD Type NMB
SIZE OF MAIN FEEDERS AND RATING OF.WIRE USED #3 copper 10 0 amp
NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS 1 100amp
NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED?VM/NO
NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 11
NUMBER OF SWITCHES 2 4 NUMBER OF OUTLETS 30
NUMBER OF LIGHT FIXTURES 2 6
7
NUMBER OF HEAT CIRCUITS 0 NUMBER OF A/C CIRCUITS 1
SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
Wire new condo units Approx 1400 sq. ft. or less
Including new 100 amp underground service
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS
TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CT 104943 E1 xd&q A//,"AJO S
NAME STATE LICENSE NO. TYPE SIGNA OF APPLICANT
PHONE NO. 644—512 4 DATE 1171011
it ey Wilhelm-CRS Approval on irmation: Request No. 19 572 Page 1
Fr m: clpsvc@nu.com>
To: WILHEL@SOUTHWINDSOR.ORG>
Dat 3/11/02 3:33PM
Subject: CRS Approval Confirmation: Request No. 191572
Your approval of the following CRS Request has been successfully processed.
CRS Work Request M 191572
House No: 101
Lot No:
Street Name: KEBALO LN
Town Name:SOUTH WINDSOR, CT
Inspector:JOHN COLLINS
Approval Date: Mar 11,2002
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT#
Applica'reby:TOWN OF SOUTH WINDSOR
BUILDING DEPARTMENT
APPRO 1540 SULLIVAN AVENUE Bldg.Permit#
z 644-2511 ext. 230
Date di Inspector
Application must be printed or typed
Location of Job(
FEE SCHEDULE
0-$1,000=$13.00 S eet 14o. Street Lot No.
Over$1,000=
13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT JQJW1V6el
APPLICANT ADDRESS !7 1 7
Irt'_7ujliy 07Z/Aj a
APPLICANT PHONE# 4
0001,111,111111111111111111111
00, VI N S OWNER f C_S
OWNER ADDRESS S W
s OWNER PHONE
C ESTIMATED COST$
IS THIS A CONTRACT COST? XYes 0 No
FEE ENCLOSED-$ 7C6
dS Cps TYPE OF JOB:
OR,New Installation
0 Alteration/Addition/Repair Revised 8/99
APPLICATION FOR PLUMBING PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? DYES El NO
RESIDENTIAL
BUSINESS CURRENT USE AND OCCUPANCY
ASSEMBLY
MERCANTILE FUTURE USE AND OCCUPANCY
EDUCATIONAL
INSTITUTIONAL ENGINEER'S NAME PHONE
FACTORY
STORAGE ADDRESS
GARAGE
MIXED USE CITY STATE ZIP
TYPE OF INSTALLATION SIZE OF MAIN DRAIN 14 f
NO.OF TOILETS . STYLE ZZ NO.URINALS STYLE
NO.OF BATHTUBS l NO.OF SHOWERS NO. OF LAVATORIES
NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE
AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS
NO.OF OTHER FIXTURES KIND /' G
ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES NO
SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR
SIZE OF DUCTS SEWER OR SEPTIC TANK
SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER (2 Q
WATER HEATER: TYPE MANUFACTURER
DESCRIPTION OF WORK
171
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS I ICENSE NO T E STATE
SIGNATURE OF APPLICAN DATE 6/
r
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT#
Application is hereby:TOWN OF SOUTH WINDSOR I Q-BUILDING DEPARTMENT
APPRO 1540 SULLIVAN AVENUE Bldg.Permit#
tb 6 644-2511 ext. 230 F 7-7
ate Building Inspector
Application must be printed or typed
FEE SCHEDULE b kAcdo (n Location of Job:
1
0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT f2F Al EZ-r M F_C,& Se2V i'L F S Zit/C..
APPLICANT ADDRESS p.0 . 6 O ye 10 $Y
INIFzrL-0 0- 0620[3
APPLICANT PHONE# 86 0- 76.3 —577 7.50'
ow H s OWNER k.F. p 2 e& es L,G..
q OWNER ADDRESS 174 94n ,.Td S 7X t eT
OWNER PHONE f?60 - (o q,- y y y
C ESTIMATED COST$ t9
1 V
IS THIS A CONTRACT COST? Yes 13 No
r CJ FEE ENCLOSED$ 7S ,..--
1
All.
s O
TYPE OF JOB:
OR C W ew Installation
13 Alteration/Addition/Repair Revised 8/99
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF STEM: TYPE OAXSIDENTIALLDING:
0zzATING
COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESjj AR LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TN S1'14 L 4i-6A Q kl CC M C.46 r-,-tZ c O P.iI. , M ec r Ve hi Fvkiv.
w o'rl c c T/1 a L r/C,F'v 2 v 9c CIA l ev -- &AX 197.2
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
OIL—GPM OIL TANK LOCATION :INSIDE OUTSIDE CAPACITY
GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
CeATg tl L vp) M/!/ -Zr4 k13 C 3
TONNAGE 3-cd 1d o5 COOLING CAPACITY(BTUH)
N-0ovs 4.
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
DT! e
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO.
j
TYPE STATE
SIGNATURE OF APPLICANT DATE CS 2 LOL
RIGHT-J SHORT FORM
Entire House
Fahrenh it Mechanical Servic J b: 09-17-2001
7 Moody Road,Enfield,CTPhone:1-860-763-5775 Fax:14X*-763--%"
Project •
For: Wheeler Estates Sr. F%mL-7 k'Unit
Kebalo Lane, South Windsor, CT
Design Information
Htg Clg Infiltration
Outside db(OF) 5 97 Method Simplified
Inside db(OF) 70 75 Construction quality Average
Design TD(OF)75 22 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 37
HEATING EQUIPMENT COOLING EQUIPMENT
Mak RHEEM AIR CON Make RHEEM MANUFAC
Trade Rheem Trade Rheem RAKA Series
RGRA-04(E,N)MAES RAKA-024JA
RCBA-2457
Efficiency 93.5 AFUE Efficiency 10.0 SEER
Heating input 45000 Btuh Sensible cooling 15960 Btuh
Heating output 42000 Btuh Latent cooling 6840 Btuh
Heating temperature rise 47 OF Total cooling 22800 Btuh
Actual h ating fan 815 cfm Actual cooling fan 815 cfm
Heating air flow factor 0.027 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh
Space thermostat Load sensible heat ratio 85 %
ROOM NAME Area Htg load Cig load Htg AVF Clg AVF
ft2) Btuh) Btuh) cfm) cfm)
Foyer 46 2868 624 79 33
Kitchen 171 4911 2491 135 133
Dining Room 142 912 312 25 17
Living Room 231 10196 6132 280 328
Master Bedreoom 230 4222 1335 116 71
Master Bath 53 1022 524 28 28
Bath 72 1206 606 33 32
Spare Bedroom 185 3824 1825 105 98
Laundry/Hallwy 120 531 1382 15 74
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wnghtsoft Rlght-Suite Resldentisl^'5.0.28 RSR25708 2001-Sep-17 17P:24:36
1
A',K C:%Fdeo-Wheeler Sr.Res.A-Unitxn
Entire Hous p 1250 29692 15232 815 815
Ventilation air 0 0
Equip. @ 1.02 RSM 15537
Latent cooling 2648
TOTALS 1250 29692 18185 815 815
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wnghtsoft Right-Suite Residential"'5.0.28 RSR25708 2001-Sepr1717:24:38
Ztx C:%Fahme WheeW Sr.Res.A-Untt.rsr Page 2