HomeMy WebLinkAbout100 Arnold Wayr kAEST.F 3XS 1SSCCAMM ARCHI t E C t S Mr. Howard E. Fitts Timothy Edwards School TO Public Bldg. Committee Chairman South Windsor, CT 239 Oak Street South Windsor, CT 06074 April 14, 1992 Attannon of: Oats We are sending you the following: Three (3) prints: Site Plan revised April 14, 1992 to show overhead electric service, transformer relocation, and oil tank. APPROVED APPROVED ASCORRECIEfl_ FOR YOUR ReIIEIN ReIISEIRESUSMIT NOTAPPROVED-SEERBAM KS FOR YCUR USE REMARKS: VERY tMJLY YOUAS. 1; Mark J. Weisman 1 LTnumis" ':qll '_^o if,l r . :m i Jim a r 7-0 0-)e dznec 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 R.Cat, AREA CODE 203/644-2511 April 21, 1992 Ms. Marcia A. Banack, Director of Planning RECEIVED Town Hall APR 21 1gg2 1540 Sullivan Ave. South Windsor, CT 06074 10. WINDSOR PLANNING DEFT; Dear Marcia: 1 Enclosed are three prints of the April 14, 1992 revised site plan for the activities planned at Timothy Edwards Middle School for the installation of relocatable classrooms. These plans are being provid d to initiate review activity with you and other areas in the Town that may have a concern or interest in this project. I believe we need Planning and Zoning Commission approval for the adjustment of the site, but probably do not have a project of a magnitude or nature which gets us involved in any other Board or Commission. However, we leave that ultimate conclusion to you and look forward to your advice on what next steps we might have to tak in order to get all the necessary approvals. We are on a fast track for this project as the clear desire of the Board of Education is to have these buildings usable in August for the opening of school at the end of that month. The three units will b located at the westerly end of the building and there will be additional parking areas constructed along the edge of the island in front of the school and along the access drive at the easterly end of the school. The parking areas at the easterly end of the school approach the property line, so maybe there is a r quirement for us to make an appearance before some agency due to the closeness of that arrangement. Obviously we will be approaching the Building Inspector, Fire Marshall, and others likely to be concerned about the classrooms themselves, but we look to you for advice on the next steps we must take to secure all appropriate approvals so the project moves ahead without complication. Very trul yours, Howard E. Fitts, Chairman Public Building Commission April 22, 1992 M E M O R A N D U M TO: Marcia A. Banach, Director of Planning FROM: Jerry C. Iazzetta, Town EngineeNRloRE: Timothy Edwards Middle School - 4tle Classrooms We have reviewed the drawing dated October 3, 1991 forwarded with your April 21, 1992 memorandum and have the following comments: 1 . Storm Water Drainage is not addressed. What is existing only one C.B. shown on plans) , or proposed? Roof drainage and additional pavement drainage need to be addressed. Drainage calculations should be provided. 2. There are no elevations or topography for existing or proposed conditions shown. 3 . The proposed overhead electric service from the C L & P pole 21707 should be underground. 4. It appears that some bituminous concrete removal is necessary in area where classrooms are to be located. This should be indicated and limits of removal identified. 5 . The 4" processed aggregate shown in pavement detail should be 6" 6 . The Fire Marshal should also review this drawing. JCl/jsv cc: Michael J. Gantick, Director of Public Works t LETTER OF TRANSMITTAL a k hOSOR•Co PLANNING DEPARTMENT TOWN OF SOUTH WINDSOR 1540 SULLIVAN AVENUE SOUTH WINDSOR CT 06074 203) 644-2511 DATE TO: Rr vr WE ARE SENDING YOU: P & Z initial plans Drainage comps P & Z final plans Bond estimate requests Inland Wetlands plans Bond reduction requests Final plans for filing Change order form Other Correspondence Copies Appl . No. Project f THESE ARE TRANSMITTED as checked below: For review and comment For your file For your use Returned with revisions As requested Other PLEASE RETURN/COMMENT BY: COMMENTS: 7to Svc J: From: 4"-C,ey 04AICCIIq jeGARO%F "(zE(rWrfA fr AM 71b GrEwsR41 'rL1D GE'r 1W r-'E EL Ra -nw e),sTsv r cTR Tarts- Pat o3 Ecr . 2 F Ovt(z o M E-tt4.F &" d F '1T3 7-Ua 6ANC6- 15 C)Ke t't'reo - A C00JSeW 6147 JjWV f 4.*VV wa J 4.0 W*V f '1v (dr #PC'(U 40 &r -1 CC . 2) TttelW ZS A oEKmC-0 CHAaNFc SoJWfZLY 0j: waRk- 1F w oxvc w9A 6e wrrw av go' o F- ?Hrs Sw9+c Rw1 F?o 2. CrrvG+'iJ'W I0CT;rV t 7'y m 4Y Bc- r. 401101 de,< C r SOMM ?40&U&Ote 4 W T10 0-1 m 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074117?4$ 7, AREA CODE 203/644-2511Cp April 30, 1992 Mr. Howard E. Fitts, Chairman Public Building Commission 239 Oak Street South Windsor, CT 06074 Dear Hap: Re: Timothy Edwards Middle School Portable Classrooms I received your letter dated April 21 with the site plans for the portable classrooms at Timothy Edwards School . The plan was reviewed by the Planning and Zoning Commission at their meeting on April 28 for a determination of whether PZC requires a full application with plans that conform with PZC's zoning regulations . The PZC determined that it does require a full application, which includes a Special Exception and Site Plan of Development. As you may recall, the PZC officially receives applications once a month at their regular meeting on the fourth Tuesday. The next regular meeting is May 26 . We can set the public hearing for early June, with PZC action the same evening, provided that the site plan submitted is in conformance with the zoning regulations and site engineering is satisfactorily completed. This is an extremely tight time frame for the site engineers; we will be happy to work with the site engineers to help meet the deadlines . I would note that the preliminary review plan which you submitted will need a substantial amount of revision in order to conform with our zoning regulations . I have enclosed a copy of the site plan section of our regulations for your use. Also, the Town Engineer has done a preliminary review of the submitted plan, and his comments are enclosed. (However, as the plan is so preliminary, the Town Engineer will not be able to do a detailed review until site engineering is completed. ) Our most optimistic PZC schedule would be: 1 . Submission of application and fully-engineered plans to Town Hall no later than Friday, May 22, for official receipt by PZC on Tuesday, May 23 . (If application is not at Town Hall the day before the regular meeting, PZC is prohibited from accepting it until their next regular meeting, by State statute. Monday, May 25, is a holiday and Town Hall is closed. ) Howard E. Fitts Page Two April 30, 1992 Timothy Edwards Middle School 2 . Public hearing/action on Tuesday, June 9 . PZC action will generally occur only if there are very few/very minor outstanding engineering issues/items . If at the time of public hearing there are many unresolved engineering items, PZC generally will not act until the items are resolved. If possible, I would recommend submitting the application and plans sooner than May 22, to provide more time for our staff to review plans, submit comments to your engineer, make any necessary revisions to the plans, and have them re-reviewed by our staff . Two weeks is an extremely tight time frame for this to occur. I also provided a copy of the preliminary plan to John McCahill for determination of whether wetlands permit or conservation plan approval are required. He has indicated that he cannot determine from the plan submitted whether there is disturbance of 20,000 square feet or more. If there is, a conservation plan must be approved by IWA/CC. Also, there is a defined channel southerly of proposed work; if site work will occur with 80 feet of this swale, a wetlands permit for regulated activity may be necessary. If IWA/CC action is required, submission of application and plans must be made no later than Friday, May 15, to be heard at the IWA/CC meeting on June 8 . If IWA/CC does not take action on June 8, they do meet again on June 15 . (IWA/CC does not make any exceptions to the application submission deadline. ) The good news is that pavement is allowed in required yard setbacks, so there is no ZBA action required for the parking area at the easterly end of the school . One last note: Please stress to the architect/engineers that the 30" x 40" drawings are oversized, do not meet our regulations ( 24" x 36" maximum size) , and cannot be filed in our Town Clerk's office. It is also unacceptable to reduce final plans down to 24" x 36" from the larger sheets, because then the scale is also reduced and no longer meets our regulations (40 scale required) . We had a lot of difficulty with this issue with the high school plans . Hap, please call me with any questions, and let me know when we can be of further assistance. I will expedite your project through the in-house staff reviews and will be glad to meet with or otherwise work with your consultants to get the fastest possible Agency/Commission action. Howard E. Fitts Page Three April 30, 1992 Timothy Edwards Middle School Very truly yours, Marcia A. Banach Director of Planning MAB/pmm cc: John McCahill, Zoning/Wetlands Enforcement Officer Jerry Iazzetta, Town Engineer CONSULTING ENGINEERS June 3, 1992 a W1NDSOR eLAN s Prix Mr. Dennis Evans Evans & Chisholm Landscape Architects 4 B ech Street Farmington, CT 06032 REF: Timothy Edwards School South Windsor, CT Drainage Review Dear Dennis: I have reviewed the drainage system for the referenced projecttodeterminetheinputofadditionalflowfromtheincreased parking area. I used information contained in the drainage study prepared by James P. Purcell Associates, Inc. as well as field observation to perform the analysis. In summary, there will be a slight increase in flow attributable to the increased impervious area for the additional parking.The effect of this increase diminishes quickly as the system is analyzed further downstream. Based on the information contained in the Purcell report, there will be no section of pipe that will be undersized as a result of this action that does not currently lack adequate capacity. If the recommendations contained in that report are implemented, the system will be adequate for the increased flow also. I hope that this answers the concerns of the Town in regards to drainage impacts of the proposed improvements. If you have any questions or require additional information, please feel free to contact me. Very truly yours, A-N CONSULTING ENGINEERS, INC. Alan L. Nafis, P.E. Vice President Manager Civil/Transportation Engineering ALN:pas 1295382 505 Willard Avenue - Newington, Connecticut 06111 • (203) 666-3366 - Fax: (203) 666-5163 SUBJECT-7 4 H t/ &j4n D S 4COL Sheet No. of 3 a'"G -Computed By Date 7 CONSULTING ENGINEERSk JOB NO. iZ-c7 Checked By )2p#Nj Date 3 •'- iOiP-ZGC.c ?a ttG c ck v 2 C LPL L R&PO r_' .Sf u S 727-,74-t dh _ 0,, Y TG= ZS A-4 ..i C,5 o of f 14, 114eq-0 CeY&O 0, 3 c) Ac- Q.4ss (sue--p) - 4c> .2-7 .4-s . SU•til,- Ta 'L / i i /, 3o Xo. _ ,Z Cam,Z7 x D. SZ OF J 7-2 A 720 Aku OOM i 0 77G 7 x tic - • (o/ - . / _ 8 r' SUBJECT %1 k G n-ky 61J,Y2.tis TC40CA-2SheerNo. o/71,r, 4"'Lr Computed By Date 3 5 Z CONSULTING ENGINEERSY JOB NO. Checked By Date li -3 9L 147 Ron Z7 Qlo — .q 3 I = S92 rE".v — 8 % SUBJECT 4bw,44 .S --S--F--nC.A. Sheet No. 3 of7113r, Pr ti CONSULTING Computed By L Date ENGINEERSY JOB NO. Checked By Date a.13222 r y'iLJ z:)Qsaw aA-,v„, /S !}oc S /JQr h-l,4- T 44 US T D% 7?fW Tv Ce 17-"O8 AC M 4-C-L y 6 cJ 4.4--_r, 7 tLr rri4-i 0 /jU T /-t-r (2/o.J7-A /f6f 5,7 0-4J D.,r %i-c."' ht,.0. 7177d rJ-1- A A14eC-r L1 Lr /,,n,LL' A-A4(.)11 Aj—,, 4- 4,:)iD l-/7 d-,3 , Ate -77:n2 =-t Lzr . G v S VK U A A101-91-J4,es i7—j Tl' AX.-"3G Co IS VCs 2.s T L-rZ /rJ 77-*L- 2,1P4 et : Tf i t l L 7h4*--r- C--S 9:-' Tit4l iti CZ LzX+Sc- /ti GC]d U c-0 U AjL.y L>L-- /"/t, D I/L-2 LtJH Yi S Ca,t1r)4 j0j L--3,3 /UJ 7?tL-r 7-'0/2.L L-rZC kar6e,7". 4) C.oN G La-WS!6,,0 TffZr- /`'Lf 1-7 4-c-T oQ r i7 d rJ t-c P,9-2 AcI olj Gt o--') ?'tt-c.- &ef-C 7-7 fj G, S L-J"Lt C( C. /3 C.L-' lvV L-D lV /r/ C.J•-rr./-r-t /1L 4::f A-0 LrG vl.I L L 00 Se, LETTER OF TRANSMITTAL C U S V PLANNING DEPARTMENT 4~ osOR'C TOWN OF SOUTH WINDSOR 1540 SULLIVAN AVENUE I SOUTH WINDSOR CT 06074 t0 203 ) 644-2511 DATE TO: O 9 r0w°f f 199, WE ARE SENDING YOU:Or q;&::Z initial plan Drainage comps P Bond estimate requests Inland Wetlands plans Bond reduction requests Final plans for filing Change order form Other Correspondence Co ies Appl . No. Pro ect 14 THESE ARE TRANSMITTED as checked below: For review and comment For your file For your use Returned with revisions As requested Other PLEASE RETURN/COMMENT BY: COMMENTS: Copy to: From: 8 9`z RECEIVED JUN ® 199? KAESTLE BOOS JI,WINDSOR PLANNING DEPL ASSOCIATES,INC. ARCHITEC TS t. John A.Kaestle Charles W.Boos David W.King Mark J.Weisman Bryan P.Berthold Brian W.Humes W.Albert Jacunski Brian A.Solywoda Lynette M.Sroka Am'r Rusty Malik June 8, 1992 Ms. Marcia A. Banach Director of Planning Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 Re: Relocatable Classroom Additions tc Timothy Edwards School South Windsor, CT KB # 91016 Dear Ms. Banach: Attached please find two (2) sets of drawings and drainage calculations related to the proposed creation of additional parking at the above referenced school . Should you require drawing G1 to be sealed and- signed, A/N Consulting Engineers, Inc. will be pleased to _do so in your office. Please call me with this or any other requests you may have. Very truly yours, Mark isman KAES LE OS ASSOCIATES, INC. MJW:acn Enclosure cc: Howard Fitts 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 (203)229-0361 Fax: 229-5303 s 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 4 AREA CODE 203/644-2511 ti SOR•C l July 17, 1992 Mr. Howard E. Fitts Public Building Commission 239, Oak Street South Windsor, CT 06074 Dear Hap: Re: Appl. #92-26PX - Timothy Edwards Middle School Please be advised that the Planning and Zonaing Commission orovedtheinstall the at its meeting on saatlTimothy,Edwards Middle School . portable classroom Also, at the July 14, 1992 meeting,the Commission approved the construction of additional parking spaces . The portable dlassrooms and parking spaces are as shown on plans preparctobed by 1991 . Kaestle Boos Assoc . , Inc . , Drawing No. L-1 and dated 31 ae Construction of the parking spaces is subject to the following condition: A re-construction meeting must be held with Town Staff 1 . P prior to the start of construction. A black and white transparent mylar and three blueprint copies of thlva plan must be submitted to this Commission and this letter exceed of to xp o must be reproduced on the mylar. The mylar can notsizeasthatisthelargestsizetheTown' s map filing system can in accommodate. ter the m lar has been signed by the Commission, tClerk,bewill AfY returned to you for filing in the office of the To Very truly yours, Louise C. Evans , Chairman LCE/pmm cc: Planning Director Chief Building Official Town Engineer Fire Marshal 1 Ce 01- Sou ?d&U&Ote a v 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 OR.co AREA CODE 203/644-2511 August 3, 1992 Mr. Howard E. Fitts Public Building Commission 239 Oak Street South Windsor, CT 06074 Dear Mr. Fitts: Re: Preconstruction Meeting - Application #92-26PX Timothy Edwards Middle School IN ATTENDANCE NAME COMPANY/ADDRESS TELEPHONE John E. McCahill Town of South Windsor 644-2511 Pat Hankard South Windsor Schools 291-1220 1737 Main Street Brian Hobbs Arthur Building Systems, Inc. 582-6552 South Main Street Terryville, CT Ron King Arthur Building Systems, Inc. 582-6552 Thomas Konopaske Arthur Building Systems, Inc. 582-6552 Laura G. Piersall Kaestle Boos Assoc. 229-0361 416 Slater Road New Britain, Ct Hal Clisby CL&P 627-1334 P.O. Box 1232 Enfield, CT 06083 A.B. Davies Town of South Windsor 644-2511 Marcia A. Banach Town of South Windsor 644-2511 The following is a brief summary of points discussed during the meeting. Erosion and Sedimentation Control 1 . All topsoil stockpile areas to be protected (ringed with haybales or equal) . 2 . During construction of the driveway a crushed stone tracking pad is to be installed and maintained if needed to minimize tracking of dirt/gravel. Calcium chloride or water is to be used for dust control as required. Public Works 1 . Four complete sets of approved/revised plan to be provided to Town prior to start of construction. They will be stamped by Planning Department along with plans developer needs . Only approved plans are to be used on jobsite. r y Mr. Howard E. Fitts Page Two August 3, 1992 Application #92-26PX 2 . The Public Works Department is to be notified forty-eight (48) hours prior to the start of major construction work with inspections and testing per Developers Checklist requested for the following: a) After site is staked out b) All drainage work c) Preparation of subgrade, compaction tests as requested by the Town d) Preparation of subbase, six (6) inch lifts e) Placement of bituminous concrete, 2 inch layers 3 . Certification of gravel used as subbase will be required by an approved testing company. 4 . No subgrade formation/base in frozen ground/snow. Same for pipe/structure installation. 5 . As built plans are to include horizontal and vertical location of all underdrains, footing drains, and sanitary sewers located as per revised as-built checklist. 6 . All pipe and structures to be backfilled with free draining material, compacted in maximum one foot lifts with approved compaction equipment or approved equal if deep trench is encountered. Any pipe or structure work requires inspection prior to backfilling. 7 . Any problems and/or questions regarding construction of this project will be directed to Mark Wiseman, Kaestle Boos or Ron King, Arthur Building Systems in the field. 8 . All filling to be done in accordance with Department of Transportation specifications . To be compacted in maximum lifts and tested as necessary. 9 . Job meetings will be held as needed, and can be called by the developer or Town. 10:Forty-eight (48) hours notice needed for certificate of occupancy inspection. Two week review period (10 working days) needed for all individual site (lot) plans prior to issuance of building permit (may be longer if application is incomplete) . See general guidelines for certificate of occupancy and building permit procedures. r Mr. Howard E. Fitts Page Three August 3, 1992 Application #92-26PX 11 .Any proposed changes are to be presented to the Engineering or Planning Department prior to implementation on change order form in triplicate. Town will attempt to turn around within 24 hours . 12.No paving after October 15 or before April 15 without written approval from Director of Public Works . 13 .Normal hours of operation 7 :00 A.M. - 5:00 P.M. , no work on Sunday. 14 .Joint between existing and new pavement to be saw-cut and sealed per Town Specifications . SNET/NU 1 . Contact utilities for coordination of utilities connection. Police Department 1 . Emergency phone numbers for the duration of the construction must be provided to the Police Department on a company letterhead. If the developer occupies or owns the building(s) after construction emergency numbers must be provided to the Police Department. Building Department 1 . Plan review with Building Official/Fire Marshal required prior to application for building permit. Coordinate with Chief Building Official. Very truly yours, Marcia A. Banach Director of Planning MAB/pmm cc:Jerry C. Iazzetta, Town Engineer Gerald Lewis, SWPS Karl Reichle, Public Works Mel Stead, Public Works Minh V. Le, SNET John R. Collins, Chief Building Official Fred Shaw, Superintendent of Pollution Control I EX LETTER OF TRANSMITTAL CEF&IftIR- We are ndina you:ENGINEERING L TO. X The attached hems. p.0.Box IS CokfwW.CT W415 Under separate cover via: 203-537-SW February 3, 1993 TO: Of Letter Marcia Banach COPY X Prints Change Order Town Planner House Plans Mvbr 1540 Sullivan Avenue Specificadons South Windsor, CTO_6074 K*01NO WIN; _w 3" 1/29/93 93-009 As'-built drawing of Timothy Edwards School THESE ARE TRANSNMW AS INDICATED BELOW: x FOR A"NOVAL AS REQUMM FOR RDMV a M00U08 FRIN" Combow REMARKS Enclosed is the asbuilt for the TE School. Before we prepare a certified mylar for filiniz, it would be appreciated if you would- review the print and give us any comments , Thank you for your attention to matter. Jess J. McMinn, L.S. President COPY TO: SIGNED: V DXIMUM AU Nor AS Nor®,vwKy Flan"W ATMcz