HomeMy WebLinkAbout10 Castlewood Drive (7)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR
PERMIT#
Application is hereby: 7BUILDINGDEPARTMENT
APPRO 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230
a e Building Inspector
Application must be printed or typed
FEE SCHEDULE I 0 Location of Job:
r CL&-%A\f-,,AjQC)
0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No. I
APPLICANT
APPLICANT ADDRESS g V /
06-C\M
APPLICANT PHONE#
OWNER n X
C o N Stq OWNER ADDRESS S
L
COD OWNER PHONE
C ESTIMATED COST$ O Cl Cl a
IS THIS A CONTRACT COST? Yes No
FEE ENCLOSED /4 V U
TYPE OF JOB:
OR C i-New Installation
Alteration/Addition/Repair 1
i
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE O BUILDING:
HEATING RESIDENTIAL
A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
XJ HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT-BTUH) , NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY
GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
5o r.2---I,S s-- _,)
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE b 0 'L
I -H - A 'CALCULATION SHEET 1503 (Modern MEthod) COV,.+w 1977 air The Ny/.OAYC.1wMtltw1.
OWN[A= A cl ZApOAESSD[SI N TtM[AATt/AE O///[AE±NCt F. OAT[
C L.A COL.a COL.C C L.O vC L.E C L.F COAL.a
iS
ROOM
t C/i///f t C L QA
O M L w M L W Ft L W 14 L w M L M nhta T w•s.
AOOy 0"Aar 10Nf.FT.I-o0Ld /Z aTv«s+Foot t O 0LEtIGTI1!t OiN01MALLf.FT. t Aalaat/aa Basal
vmftOOM-AftD OUTS/01 00011 A A E A a. t7
STUN STUN aTVN STUN aTVa
WALL COMSTAUCTI N mooed LJPL PIT. PIT/Ms f.Laaa3 a N) 407 le..vOO SOD DO AX 0 U TOTALS AAOtATt N
s TYPE i LASS
Q S0Ut
PAD"Ll«i 1: sELscrto
Ntww a1&a1Ma~tN L in*S) Q U go j
7 CEILIN CONSTAUCTI N C d / 7 n
MOOS.L a W1 D ADD goo U!J 8 J-
FLOOR CONSTRUCTION 0
O AATiT10M Coen m JCT10N sae
2 O/
O Z oU
e: -•Ewt Mau
t rar Tw.assERENcE• 8'30 70 70 fQ
rITOTAL aTliOs'AT oEs/aawl TEMP.DIFFERENCE p p p K
COLA COL.a COL.N COL.1 COL./ COL.K COL.L A1L STYM TOTAL
1 AOOY 01F aWIL414gO AAOIATION
t AT S[LECTEO
0 N L N N L w N L w N L w FI L w 04MW"TlYR•
01 TtA[MCt2AOOYOIYaNf/ONf.FT.
V 41 / 1 Z 0
3 L6000 M EXPO"D WALLS.FT.
s 11011o0111r ARIDOUTSIDE OOpA AREA
Z At
ja
BTU" STUN STUN STUN STUN
i WALL C06=1LOCTI N UN CREASE SATNAOOM
ITsWe e.Lao=a N) O sDO tJ
if TOTAL 20%
6 TYPE Of GLASS
V
I800111tw00100111wd 1a.Lana a1
7 CEILIMOCONSTAVCTION NU_CL CTK/
tNCRETE FLOOR O---
I
sFORORGftO CcOo
OR FILL
O
tT@We!.L a W!GRADE LEVEL.USE LINEAR
a FLOOR CONSTRUCTI Nt
O 0 FEET OF EXPOSED EDGE
ITaMa a.L a w s,Lin s c)
C LO AATITI N CONSTRUCTION
1Taws S.L a MI
to e t waa tw.w O.w+...1 D/t Iis
2 was.twat O-«...y.l 91Ix
S Waft IwM 000"ObO)a/EAL Hall
J
t t T TAL STUN AT 7e<TEM1, DIF F E RE NCE' 34po d O12TOTALSTUNATDESIGNTEM/.OtFF IREMCI Q
f+»laFiw Is wara0ia fraw+Twa Nt+lrewbs Insntute.36 Aw"a Rasa,aaraMar Naywta•N J 07f22 FORS. 1503