HomeMy WebLinkAbout10 Castlewood Drive (6)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WIlVDSOR PERMIT# Application is hereby: I Li sx—BUILDING DEPARTMENT APPRO 1540 SULLIVAN AVENUE Bldg.Permit# j(/2, 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE 0-$1,000=$13.00 Street No. Street Lot No. 16-o o Over$1,000= 443-00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS yf_,1 L ' led avl l APPLICANT PHONE# 000 N 3 OWNER O L f 4 OWNER ADDRESS Z 3 O OWNER PHONE C ESTIMATED COST$ IS THIS A CONTRACT COST? Mrfe"s 0 No FEE ENCLOSED$ 9 D.5 TYPE OF JOB: SORB CO CSNew Installation D Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF B DING: H,EATING UME SIDENTIAL ffA/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EX TLNG RADIATION ADDITIONAL RADIATION TOTAL RADIATI DESIGN OUTSIDE OF INSIDE OF DIFFERE F TOTAL HEA SS(BTUH) OF(HEAT LOSS SHEET MUST ACCO APPLICATIO DESCRIBE ALL HEAT EQUIPMENT(INCLUDING MODEL NO.) GROSS HEATING CAPACITY(INPUT- ET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTS CAPACITY GAS- T LPG TANK CAPACITY ELEC -KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE 7O OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) Ile r r I k O TONNAGE COOLING CAPACITY(BTUH) e VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK S".®/y r ,v THE UNDERSIGNED HEREBY APPLIES FOR A PERM T TO PERFORM THE WORK 16ESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 7 CONTRACTORS LICEN E STATE SIGNATURE OF APPLICAN DATE y- 2- RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House R & E H ating & Cooling Inc. Job:243-047 10 Castelwood Road 5-24-02 310 Nutmeg Rd.South,South Windsor,CT OW74 Phor e:NO-282-7782 Fax:860-282-7701 Project • For: Clark Realty,lnc 658 Ellington RD,South Windsor, CT 06074 Notes: 243-047 10 Castlewood Road Design Information Weather: Hartford, Brainard Field, CT, US Winter Design Conditions Summer Design Conditions Outside db 6 OF Outside db 88 OF Inside db 70 OF Inside db 70 OF Design TD 64 OF Design TD 18 OF Daily ran M Relative fiumidity 50 % Moisture difference 38 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 60636 Btuh Structure 38892 Btuh Ventilation air 0 cfm Ventilation 0 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 OF Design heat load 60636 Btuh Use mfg.data n Rate/smng multiplier 0.93 Infiltration Total lens.equip. load 36170 Btuh Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage Fireplaces 1 Internal gains 5060 Btuh Ventilation 0 Btuh Heatingg Cooling Infiltration 4818 Btuh Area(fry)2879 2879 Total latent equip. load 9878 Btuh Volume(ft3) 28079 28079 Air changes/hour 0.9 0.4 Total equipment load 46048 Btuh Equiv.AVF(cfm) 422 188 Heating Equipment Summary Cooling Equipment Summary Make n/a Make Heil Trade n/a Trade Heil n/a HAC060 EPDO60 Efficiency n/a Efficiency 10.0 EER Heating input 0 Btuh Sensible cooling 42000 Btuh Heating output. 0 Btuh Latent cooling 18000 Btuh Heating temp rise 0 OF Total cooling 60000 Btuh Actual heating fan 2000 cfm Actual cooling fan 20W cfm Heating air flow factor 0.033 dm/Btuh Cooling air flow factor 0.051 cfm/Btuh Space thermostat Load sensible heat ratio 80 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. Wh "t50ft Right-Suite ResidentialTM 5.0.28 RSR27412 2002-May-2409:31:15 C:1My Dcuments\Wrightsoft HVACU43-047 10 Castelwood Road.mr Page 1