HomeMy WebLinkAbout1 Amaryllis Lane (6)FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: NO. TOWN OF SOUTH WINDSOR EST.COST: BLDG. PERMIT NO. p y 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $1,000 - $10.00 P 9P,v S 1-AIV 1000 or fraction LOCATION OF BUILDING(, C) S thereof - $10.00 OWNER ADDRESS TOWN PHONE NO. RVAC CONTRACTOR I ADDRESS ITOWN PHONE NO. TYPE OF SYSTEM: HEATING 3z TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC ,-'WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GP# J _ GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITYc 75 LPG TANK - CAPACITY EXISTING RADIATION4ZaiaC, ADDITIONAL RADIATION TOTAL PADIATION IvZ DESIGN TEMP. OUTSIDE "7 OF INSIDEf°F DIFFERENCE (ca$ OF TOTAL HEAT LOSS (BTUH) 796 HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPME (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) ) p ( ) NET RATING (0 TPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 3-aa-9- fi. STATh LICENSE - NAME & TYPE #DATE SIGNATUtt OF APPLIC T j0-3bY 3 APPROVED DATE BD 4A 11/88 I - B - R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronks Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE C L.A COLS COL.C COL.D COL.E COL.F COL.G 1 ROOM O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.U BTUH per Pool of 3 LENGTH EXPOSED WALLS, FT. 4 Radiation Selected C WINDOW AND OUTSIDE DOOR AREA to BTUH BTUH BTUH STUN STUN 5 WALL CONSTRUCTION Table 9, Line 3 x H) ROOM LIN.FT.OF TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used for Line 5) 7 CEILING CONSTRUCTION C IT able 9, L x W) B FLOOR CONSTRUCTIONt ITable 9, L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H G 10 _c 1 all(With Openings)C 2 Wells(With Openings) X 3 Wells(With Openings) or Ent.Hall p. 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL.A _COL.B COL.H COL. 1 COL_J COL. K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION1ROOMATSELECTED O H L W H L W H L W H L W H I L W DESIGN TEMP.- 2 ROOM DIMENSIONS, FT DIFFERENCE U 3 LENGTH EXPOSED WALLS. FT. Q 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9,Llne 3 x HI TOTAL 20% 6 TYPE OF GLASS Bottom of table used for Line 5) IFOR CONCRETE FLOOR ON7CEILINGCONSTRUCTIONGROUNDORFILL IT able 9 L x W)GRADE LEVEL,USE LINEAR g FLOOR CONSTRUCTION[ FEET OF EXPOSED EDGE Table 9, L x W or Lin Ft I 9 COLD PARTITION CONSTRUCTION Table 9. L x H) 10 c I Wall(With Openings) O 2 Walls(With Openings) G X 3 Walls(With Openings) or Ent Hell r- 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form Is wadable from The Hydronlcs Institute, 36 Russo Piece,Berkeley Heights,N J 07922 1= B= R CALCULATION SHEET 1603 (Modern Method) Copyright 2977 by The HydronM$Intl OWNER wom gtA r1 Dc t5 ADDRESS Ldl' F5AC,Fr .AWO Aw DESIGN TEMPERATURE DIFF[RtNC[aF, DATE L COL A COL.B COL C COL D COL E PI COL.F COL.O 1 ROOM a L v1n1 Alf #,Z Mi'v KJTCNE 80 D O H L w N L w H I L I W H L W H L IN Demon Water Temp' I2ROOMDIMENSIONS,FT. 7d0 Z BTU"per feet of j V 3 LENGTH EXPOSED WALLS,FT.Radiation Soleepd I WINDOW AND OUTSIDE DOOR AREA a BTU" BTUH TUN BTUH BTU" 6 WALL CONSTRUCTION no Y LIN.FT.OFTableB,Lira 3:H) 05 j yD 0 goo 0 00 TOTALS RADIATION 6 TYPE OF GLASS 4 FROM LINE 12 SELECTED Bottom of table used for Line 5)3 ! 0 ze 00 2 f 7 CEILING CONSTRUCTION Z C NOD b Table B,L:W) D J I t B FLOOR CONSTRUCTIONf OvTTableB,L x W or Lin.Ft) 0 T! J^0 Q O E J coo B COLD PARTITION CONST74UCTION Table B,L:H) NA G 10 _o t wall(With OPenirqs) 2 Wells(whh Openings)j 019 2700 P O p Z Z 0 0 - 3 Walls IWM Openings)or Ent Hall h Z p 0ofl 78 D O J11TOTALBTUHAT70FTEMP.DIFFERENCE' 00 OD zK 12 TOTAL BTUH AT DESIGN TEMP.-DIFFERENCE 4 Q f7 L 9 39 ,600COLACOL.B Z COL.H COL I COL.J COL.K Z COL.L TOTAL TU TOTAL 1 ROOM 14A IV OlOt WAtKIWCL05 FQ 13&V OF BUILDING RADIATION a AT SELECTED O H L W M L W N L W H L W H L W DESIGN TEMI.• 2 ROOM DIMENSIONS,FT. V g Z DIFFERENCEE DOMes ne H W1 3 LENGTH EXPOSED WALLS,FT.Z 0 Z 1 31 led, a WINDOW AND OUTSIDE DOOR AREA LLto i 7'oT t, BTU" BTU" BTUH TUN TUH J / v e 5 WALL CONSTRUCTION INCREASE BATHROOM Table B,Lin•3 x H) os b O0 6 D TOTAL 20% 6 TYPE F GLASS 6 n0BottomoftableusedforLine5) 7 CEILING CONSTRUCTION FOR CONCRETE FLOOR ON Table B,L:W) DL 300 I O O D 0 GROUN OR FILL AT GRADE DLEVEL.USE LINEAR 8 FLOOR CONSTRUCTIONf FEET OF EXPOSED EDGE Table B,L:W or Lin.Ft) O 00 B COLD PARTITION CONSTRUCTION Table B,L a H) 10 =0 1 Well(Whh Openings) Q 7 O a 2 Walls(Whh Openings) E0 00 3 Wells(With OpanlnpQ or Ent Hdl HJ Qzrj 11 TOTAL BTUH AT 70F TEMP,DIFFERENCE* D D Z 0 0 y Z0 12 TOTAL BTUH AT DESIGN TEMP,DIFFERENCE n O Z D a This form Is evallable from The Hydronics Insttw%%35 Russo PlaciL Berkley Height;N.J.07E22 FORM 3503