HomeMy WebLinkAbout1 Amaryllis Lane (6)FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE:
NO. TOWN OF SOUTH WINDSOR EST.COST:
BLDG. PERMIT NO. p y 1540 SULLIVAN AVENUE FEE
SOUTH WINDSOR, CT 06074 FEES:
644-2511 - Ext. 230 0 - $1,000 - $10.00
P 9P,v S 1-AIV 1000 or fraction
LOCATION OF BUILDING(, C) S thereof - $10.00
OWNER ADDRESS TOWN PHONE NO.
RVAC CONTRACTOR I ADDRESS ITOWN PHONE NO.
TYPE OF SYSTEM: HEATING 3z TYPE OF BUILDING: RESIDENTIAL
A/C COMMERCIAL
VENTILATION BUSINESS
INDUSTRIAL
IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC ,-'WARM AIR
UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE)
TYPE OF FUEL: OIL-GP# J _ GAS IN-PUT ELECTRIC KW
WOOD COAL
OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITYc 75
LPG TANK - CAPACITY
EXISTING RADIATION4ZaiaC, ADDITIONAL RADIATION TOTAL PADIATION IvZ
DESIGN TEMP. OUTSIDE "7 OF INSIDEf°F DIFFERENCE (ca$ OF
TOTAL HEAT LOSS (BTUH) 796 HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPME (INCLUDING MAKE & MODEL NO.):
GROSS HEATING CAPACITY (INPUT-BTUH) ) p ( ) NET RATING (0 TPUT-BTUH)
IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN (BTUH)
HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
TONNAGE COOLING CAPACITY (BTUH)
IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) :
TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM)
PLAN MUST ACCOMPANY APPLICATION)
The undersigned hereby applies for a permit to perform the following work and is to comply
with all local ordinances and State of Conn. Building Codes in the performance of such work.
FURTHER DESCRIPTION OF WORK:
3-aa-9- fi.
STATh LICENSE - NAME & TYPE #DATE SIGNATUtt OF APPLIC T
j0-3bY 3
APPROVED DATE
BD 4A 11/88
I - B - R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronks Institute
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
C L.A COLS COL.C COL.D COL.E COL.F COL.G
1 ROOM
O H L W H L W H L W H L W H L W Design Water Temp.
2 ROOM DIMENSIONS, FT.U BTUH per Pool of
3 LENGTH EXPOSED WALLS, FT. 4 Radiation Selected
C WINDOW AND OUTSIDE DOOR AREA to
BTUH BTUH BTUH STUN STUN
5 WALL CONSTRUCTION
Table 9, Line 3 x H)
ROOM LIN.FT.OF
TOTALS RADIATION
6 TYPE OF GLASS FROM LINE 12 SELECTED
Bottom of table used for Line 5)
7 CEILING CONSTRUCTION C
IT able 9, L x W)
B FLOOR CONSTRUCTIONt
ITable 9, L x W or Lin. F t) E
9 COLD PARTITION CONSTRUCTION F
Table 9, L x H
G
10 _c 1 all(With Openings)C
2 Wells(With Openings) X
3 Wells(With Openings) or Ent.Hall p.
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K
COL.A _COL.B COL.H COL. 1 COL_J COL. K COL.L TOTAL BTUH TOTAL
OF BUILDING RADIATION1ROOMATSELECTED
O H L W H L W H L W H L W H I L W DESIGN TEMP.-
2 ROOM DIMENSIONS, FT
DIFFERENCE
U
3 LENGTH EXPOSED WALLS. FT. Q
4 WINDOW AND OUTSIDE DOOR AREA LL
BTUH BTUH BTUH BTUH BTUH
5 WALL CONSTRUCTION INCREASE BATHROOM
Table 9,Llne 3 x HI TOTAL 20%
6 TYPE OF GLASS
Bottom of table used for Line 5)
IFOR CONCRETE FLOOR ON7CEILINGCONSTRUCTIONGROUNDORFILL
IT able 9 L x W)GRADE LEVEL,USE LINEAR
g FLOOR CONSTRUCTION[ FEET OF EXPOSED EDGE
Table 9, L x W or Lin Ft I
9 COLD PARTITION CONSTRUCTION
Table 9. L x H)
10 c I Wall(With Openings)
O
2 Walls(With Openings) G X
3 Walls(With Openings) or Ent Hell r-
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE
FORM 1503
This form Is wadable from The Hydronlcs Institute, 36 Russo Piece,Berkeley Heights,N J 07922
1= B= R CALCULATION SHEET 1603 (Modern Method) Copyright 2977 by The HydronM$Intl
OWNER wom gtA r1 Dc t5 ADDRESS Ldl' F5AC,Fr .AWO Aw
DESIGN TEMPERATURE DIFF[RtNC[aF, DATE L
COL A COL.B COL C COL D COL E PI COL.F COL.O
1 ROOM a L v1n1 Alf #,Z Mi'v KJTCNE 80 D
O H L w N L w H I L I W H L W H L IN Demon Water Temp'
I2ROOMDIMENSIONS,FT. 7d0 Z BTU"per feet of j V
3 LENGTH EXPOSED WALLS,FT.Radiation Soleepd
I WINDOW AND OUTSIDE DOOR AREA a
BTU" BTUH TUN BTUH BTU"
6 WALL CONSTRUCTION no Y LIN.FT.OFTableB,Lira 3:H) 05 j yD 0 goo 0 00 TOTALS RADIATION
6 TYPE OF GLASS 4
FROM LINE 12 SELECTED
Bottom of table used for Line 5)3 ! 0 ze 00 2
f 7 CEILING CONSTRUCTION
Z C NOD b
Table B,L:W) D J
I
t B FLOOR CONSTRUCTIONf
OvTTableB,L x W or Lin.Ft) 0 T! J^0 Q O E J coo
B COLD PARTITION CONST74UCTION
Table B,L:H) NA G
10 _o t wall(With OPenirqs)
2 Wells(whh Openings)j 019 2700 P O p Z Z 0 0 -
3 Walls IWM Openings)or Ent Hall h Z
p
0ofl
78 D O J11TOTALBTUHAT70FTEMP.DIFFERENCE' 00 OD zK 12 TOTAL BTUH AT DESIGN TEMP.-DIFFERENCE 4 Q f7
L
9
39 ,600COLACOL.B Z COL.H COL I COL.J COL.K Z COL.L TOTAL TU TOTAL
1 ROOM 14A IV OlOt WAtKIWCL05 FQ 13&V OF BUILDING RADIATION
a AT SELECTED
O H L W M L W N L W H L W H L W DESIGN TEMI.•
2 ROOM DIMENSIONS,FT. V g Z
DIFFERENCEE DOMes ne H W1
3 LENGTH EXPOSED WALLS,FT.Z 0 Z 1 31 led,
a WINDOW AND OUTSIDE DOOR AREA LLto i 7'oT t,
BTU" BTU" BTUH TUN TUH J / v
e 5 WALL CONSTRUCTION INCREASE BATHROOM
Table B,Lin•3 x H) os b O0 6 D TOTAL 20%
6 TYPE F GLASS 6 n0BottomoftableusedforLine5)
7 CEILING CONSTRUCTION FOR CONCRETE FLOOR ON
Table B,L:W) DL 300 I O O D 0 GROUN OR FILL AT
GRADE DLEVEL.USE LINEAR
8 FLOOR CONSTRUCTIONf FEET OF EXPOSED EDGE
Table B,L:W or Lin.Ft) O 00
B COLD PARTITION CONSTRUCTION
Table B,L a H)
10 =0 1 Well(Whh Openings) Q 7 O a
2 Walls(Whh Openings) E0 00
3 Wells(With OpanlnpQ or Ent Hdl HJ Qzrj
11 TOTAL BTUH AT 70F TEMP,DIFFERENCE* D D Z 0 0 y Z0
12 TOTAL BTUH AT DESIGN TEMP,DIFFERENCE n O Z D a
This form Is evallable from The Hydronics Insttw%%35 Russo PlaciL Berkley Height;N.J.07E22 FORM 3503