HomeMy WebLinkAbout425 Sullivan Avenue archit MEETING REPORT TENANT FIT-OUT FOR C&P MACHINE 425 SULLIVAN AVENUE SOUTH%INDSOR,CT November 5,2010 A meeting was held on Friday, October 29, 2010 to review,code requirements for the proposed tenant fit- out of the existing building for C&P Machine located at 425 Sullivan Avenue, South Windsor,CT. Meeting Report prepared by Traci Hillebrecht, Architx,LLC. Present: Michael Rose Building Official Walter Summers Fire Marshal Stephen Farrow R&R Construction(Contractor) Traci Hillebrecht Architx,LLC(Architect) Discussion: The following items were discussed,not necessarily in the order presented. • Preliminary building area calculations were presented by Ms. Hillebrecht, with the proposed use of Factory F-2 and Business B as non-separated mixed use. o Note: Review Part IV of the CT State Fire Safety Code for requirements related to existing industrial occupancies. o Note: All new work will comply with the CT State Building Code and Part III of the CT State Fire Safety Code and all referenced standards. • It is acceptable to all that the Architect will prepare floor plans and the code information, but the remainder of drawings/shop drawings including mechanical, electrical, plumbing, and fire protection systems will be prepared by the Contractor's subcontractors and/or engineers. • There are 2 existing exterior door exits that are currently non-compliant and will need to be fixed. One door leads to non-compliant steps (no landing), and the rear door does not connect to a public way with a walk and the route is blocked by a railing. o Mr. Farrow will apply for a permit as necessary to perform the concrete work prior to cold weather. o Mr.Farrow will confirm slope of existing ramp at existing rear exit door. • Provide a minimum of two manual pull stations(ref. Part IV, Section 40.3.4.2.) • Maximum travel distance for the F-2 occupancy maybe 400 feet to comply with IBC and Special Purpose Industrial Occupancy(ref. Part IV,Table 40.2.6.) Maximum travel distance for Business is 300 feet. ARCHITX,LLC • 64 HARTFORD TURNPIKE • TOLLAND,Cr 06084-2842 • P860.872.9627 • F860.896,5207 RESIDENTIAL • COMMERCIAL • ARCHITECTURAL SPECIFICATIONS archit MEETING REPORT TENANT FIT-OUT FOR C&P MACHINE 425 SULLIVAN AVENUE SOUTH WINDSOR,Cr November 5,2010 • The temporary use of the adjacent space during construction, for set-up and use of 4 to 5 machines and a total of 2 employees, is acceptable to Mr. Summers. The Building Owner will need to review egress requirements on-site with the building officials and Mr. Summers prior to temporary occupancy. • The adjacent space to the proposed tenant fit-out will remain vacant following completion of the tenant fitout. o Note: Comply with requirements in NFPA I Uniform Fire Code and the 2010 CT supplement thereto. • Following the meeting, Mr. Rose confirmed that the new tenant fit-out will not be considered a change of occupancy. o Note: Means of egress are not required to be handicapped accessible in existing buildings. Copies: Christopher Dougan,Chief Building Official Michael Rose, Building Official Walter Summers,Fire Marshal Stephen Farrow, R&.R Construction ARCHITX,LLC • 64 HARTFORD TURNPIKE • TOLLAND,CI 06084-2842 • P860.872.9627 • F8W.8965267 RESIDENTIAL • COMMERCIAL • ARCHITECTURAL SPECIFICATIONS