HomeMy WebLinkAbout135 Sullivan Avenue - Life Safety System FIRE ALARM SYSTEM RECORD OF COMPLETION To be competed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY INFORMATION Name of property: Mobis Address: 135 Sullivan Ave. South Windsor, CT 06074 Description of property: Warehouse Occupancy type: Name of property representative: John Fontana Address: Scannell Properties Phone: Fax: E-mail: Authority having jurisdiction over this property: Phone: Fax: E-mail: 2. FIRE ALARM SYSTEM INSTALLATION, SERVICE, AND TESTING INFORMATION Installation contractor for this equipment: Daniel's Electric Inc Address: 6 Sandra Dr. South Windsor, CT 06074 Phone: 860-289-8512 Fax: E-mail: Service organization for this equipment: TEC Control Systems, Inc. Address: 67 Britton Ave Torrington, CT 06790 Phone: 860-489-1456 Fax: E-mail: Location of as-built drawings: On Premise Location of historical test reports: N/A Location of system operation and maintenance manuals: On Premise A contract for test and inspection in accordance with NFPA standards is in effect as of Contracted testing company: Address: Phone: Fax: E-mail: Contract expires: Contract number: Frequency of routine inspections: 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter Reference of System Type: Protected Premise Name of organization receiving alarm signals with phone numbers(if applicable): Monitor Controls Alarm: Phone: 1-877-859-9636 Supervisory: Phone: Trouble: Phone: Entity to which alarms are retransmitted: phone: N/A Method of retransmission of alarms to that organization or location: N/A Reprinted with permission from NFPA 720-2007,National Fire Alarrn Code,Copyright©2007,National Fire Protection Association,Quincy,MA Nalionul Fire Alarnr Code@ and NFPA 720 are registered trademarks of the National lire Protection Association,Inc.,Quincy,MA 02169 (1 of 5) 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE (continued) If Chapter 8,note the means of transmission from the protected premises to the central station: ©Digital alarm communicator ❑MCCLtlloh ❑Multiplex ❑2-way radio Ell-way radio ❑N/A If Chapter 9, note the type of connection: ❑Local energy ❑Shunt ❑NIA 3.1 System Software Operating System;(executive) software revision level: Verlfire TOOTS Site-specific software revision date: Revision completed by: 4. SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to this sYstens (see NFPA 72, Table 6.6.1): Quantity: Style: 4 Class: B 5. ALARM-INITIATING DEVICES AND CIRCUITS Characteristics of initiating device circuits connected to this s}jstent(see NFPA 72, Table 65): Quantity: Style: Class: 5.1 Manual Initiating Devices 5J.1 Manual Pull Stations Number of manual pull stations: 23 Type of devices: ©Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors ❑Number of smoke detectors: 2 Type of coverage: ❑Complete area ©Partial area ❑Nonrequired partial area ❑N/A Type of devices: ©Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A Type of smoke detector sensing technology: ❑Ionization ©Photoelectric 5.2.2 Duct Smoke Detectors Dumber of duct smoke detectors: 3 TI pe of coverage: Type of devices: ©Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A Type of smoke detector sensing,technology: ❑Ionization ©Photoelectric 5.2.3 Heat Detectors Number of heat detectors: NA Type of coverage: ❑Complete area ❑Partial area ❑Nonrequired partial area Z N/A Type of devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter ©N/A 5.2.4 Sprinkler Watertlow Detectors Number of waterflow detectors: 8 Type of devices: Z Addressable ❑Conventional ❑Coded ❑Transmitter ❑NIA 5.2.5 Alarm Verification Number of devices subject to alarm verification: NA Alarm verification on this system is: ❑Enabled ❑Disabled ❑Set for seconds Reprinted with permission from NFPA 720-2007,Nutional fire Atarnt Code,Copyright 0 2007,National Fire Protection Association,Quincy,IMA National Fire Alarm Code OO and NFPA 729.u-e registered trademarks of the National Fire Protection Association,Inc..Quincy,MA 02169 (2 of 5) C. SUPERVISORY SIGNAL - INITIATING DEVICES AND CIRCUITS 6.1 Sprinkler System Number of valve supervisory switches: 8 Type of devices: ©Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A 6.2 Fire Pump Type of fire pump: ❑Electric ❑Diesel. Type of fire pump supervisory devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter N/A Fire Pump Functions Supervised ❑Fire pump power ❑Fire pump running ❑Fire pump phase reversal ❑ Selector switch not in auto ❑Engine or control panel trouble ❑Low fuel Other: 6.3 Engine-Driven Generator Type of generator supervisory devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter ©N/A ❑Engine or control panel trouble ❑Generator running ❑Selector switch not in auto ❑ Low fuel Other: 7. ANNUNCIATORS 7.1 Annunciator 1 ❑Local Remote Type: ❑Addressable ❑Directory Z Graphic ❑N/A Location: Front Lobby 7.2 Annunciator 2 ❑Local ❑Remote Type: ❑Addressable ❑Directory ❑Graphic © N/A Location: NA 7.3 Annunciator 3 ❑Local ❑Remote Type: ❑Addressable ❑Directory []Graphic ©N/A Location: NA 8. ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1 Emergency Voice Alarm Service Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker zones: 8.2 Telephone Jacks Number of telephone jacks installed: Number of telephone handsets stored on site: 'lope of telephone system installed: ❑Electrically powered ❑Sound powered m N/A 8.3 Nonvoice Audible System Characteristics nf'710ti frcation device circuits connected to this system (see Nf FA 72, Table 6.5): Quantity: 10 Style: Y Class: B Reprinted with permission fioiu NFPA 720-2007,Nalloourl Fier Alarm Gwk,Copyright 02007,National Fire Protection Association,Quincy,MA Natiojud Fire:Alarm C ode©and n'FPA 72@ are registered tradenuarks of the National Fire Protection Association,Inc.,Quincy,MA 02169 (3 of 5) S. ALARM NOTIFICATION DEVICES AND CIRCUITS (continued) 8.4 Types and Quantities of Nonvoice Notification Appliances Installer! Bells:__ With visual device. Horns: 50 With visual device: 50 Chimes: With visual device: Bells: With visual device: Vistial devices without audible devices: 4 Other(describe): 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED ❑Hold-open door releasing devices ❑Smoke mana`7ement or smoke control ❑Door unlocking ❑Elevator recall ❑Other 10.SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage 120 Amps Overcurrent protection: Type Breaker Amps 20 Location(of primary supply panelboard): North End Electrical Panel Disconnecting means location: Panel L2 Circuit 16 10.2 Secondary/ Power Location: FACP ape: Battery Nominal voltage, 24 Current rating: Number of standby batteries: 2 Amp hour rating: 18 Location of emergency generator: Location of fuel storage: Calculated capacity of secondary power to drive the system In standby mode: 24 Hours In alarm mode: 5 Min 11.RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked•for opens, shorts, ground faults, and improper branching, but before conehicting operational acceptance tests. The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.) ©NFPA 72 [Z NFPA 70, National Electrical Code, Article 760 © Manufacturer's published instructions []Other(please specify): System deviations from referenced NFPA standards: Signed: Printed name: Eric J. Guerin Date: 12/10/15 Organization: TEC Control Systems Title: Technician Phone: 860-489-1456 12.RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or in the presence of the signer shown below, on the date shown below,and were found to be operating properly in accordance with the requirements of: ©NFPA 72 ©NFPA 70,National Electrical Code, Article 760 ©Manufacturer's published instructions ❑Other(please specify): ©Documentation in accordanc_e with Inspection and Testing Form(Figure 10.6.2.3)is attached Signed: bltc Printed name: Eric J. Guerin Date: 12/10/15 Organization: T C Control Systems Title: Technician phone: 860-489-1456 Reprinted with permission froin NFPA 720-2007,National Fite Alarm Code,Copyright©2007,National Fire Protection Association,Quincy,MA National Fire Alarm Cade®and NFPA 72 s are registered trademarks of the National Fire,Protection Association,Inc.,Quincy,MA 02169 (4 of i) 13. CERTIFICATIONS AND APPROVALS 13.1 System Installation Contractor This sys em 11 ecifiedn1rein has been installed and tested according to till NFPA standards cited herein. Si ,necl: Pr-inted name: Chris Davis Date: 12/10/15 Organization: _ D niel's Electric Title: Project Manager Phone;860-289-8512 13.2 System Service Contractor This systern as specified her in has been installed and tested according to all NFPA standards cited herein, Signed: a,--., Printed name: Eric J. Guerin Date: 12/10/15 Organization: TEC C ntrol Systems Title: Technician Phone:860-489-1546` 13.3 Central Station This system as specified herein will be monitored according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.4 Property Representative I accept this system as ving bee installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: John Fontana Date: 12/10/15 Organization: Scannell Properties Title: General Contractor Phone: 13.5 Authority Having Jurisdiction I have witnessed a satisfactory acceptance test of this system and find it to he installed and operating properly in accordance with its approved plans and specifications, its approved sequence of operations, and with all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: __ Phone: Changed RTU-1, RTU-2, and RTU-3 from Alarm to supervisory Changed all descriptions of doors to corresponding door numbers Reprinted with permission from NFPA 72@-2007,Na ional Fire Alarm Code,Copyright CD 2007,National Fire Protection Association,Quincy.MA Nationcil Fire Alarm Code@ and NFPA 72©are registered trademarks of the National Fire Protection Association,Inc.,Quincy,MA 02169 (5 of 5)