Loading...
HomeMy WebLinkAbout176 Windsorville Road (2) 40,MN stq C �- ` iovu O-P Saa� V&U&at C ' v� 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 SOR co�� TELEPHONE(860)644-2511 CERTIFIED MAIL#7011 1570 0000 6337 1952 March 24,2016 David Fresk 200 Sullivan Avenue South Windsor, CT 06074 Dear Mr. Fresk: Re: Appl. 16-10P,J.E. Shepard Company Home Farm Apartments Temporary & Conditional Permit Renewal Please be advised that the Planning and Zoning Commission at its March 22, 2016 meeting approved the above-referenced request for renewal of a 2 year temporary and conditional permit (Section 2.13.a) to allow two apartments, known as Home Farm Apartments, on property located at 176 Windsorville Road, RR zone. This approval is subject to the following terms and conditions: 1. The applicant must test the water annually and provide the results to the town's Environmental Health Officer. 2. The permit is for a two year renewal and will expire on April 8, 2018. If this use is to continue beyond that date, a renewal will be required. Sincerely, Gary Bazzano, Chairman Planning and Zoning Commission GB/llz Cc: Zoning Enforcement Officer Chief Building Official Assessor RECE�VEp DEC 0 8 2017 S0t17'H MNpSOR HEgLTH pEPT PHOE1VIX t 7op- � Environmental Laboratories, Inc, Tuesday, November 14, 2017 Mr James King 176 Windsorville Road South Windsor CT 06074 Project ID: 176 WINDSORVILLE RD Sample ID#s: BZ38700 This laboratory is in compliance with the NELAC requirements of procedures used except where indicated. This report contains results for the parameters tested, under the sampling conditions described on the Chain Of Custody, as received by the laboratory. This report is incomplete unless all pages indicated in the pagination at the bottom of the page are included. A scanned version of the COC form accompanies the analytical report and is an exact duplicate of the original. If you have any questions concerning this testing, please do not hesitate to contact Phoenix Client Services at ext. 200. Sincerely yours, AU& Phyllis hiller Laboratory Director NELAC -#NY11301 NJ Lab Registration #CT-003 CT Lab Registration #PH-0618 NY Lab Registration #11301 MA Lab Registration #M-CT007 PA Lab Registration #68-03530 ME Lab Registration#CT-007 RI Lab Registration #63 NH Lab Registration#213693-A,B VT Lab Registration #VT11301 587 East Middle Turnpike,P.O.Box 370,Manchester,CT 06040 Telephone(860)645-1102 Fax(860)645-0823 Page 1 of 7 1 -IC—Cpq�8 U PHOUVIX0, U -4 Environmental Laboratories, Inc. NY#113o1 - 587 East Middle Turnpike, P.O.Box 370,Manchester,CT 06045 Tel.(860)645-1102 Fax(860)645-0823 SDG Comments November 14, 2017 SDG I.D.: GBZ38700 The regulatory hold time for Chlorine is immediately.This Chlorine was performed in the laboratory and may be considered outside of hold-time. Page 2 of 7 PHOM*,�--, Environmental Laboratories, Inc. 587 East Middle Turnpike,P.O.Box 370, Manchester,CT 06045 Analysis Report FOR: Mr James King 176 Windsorville Road November 14, 2017 South Windsor CT 06074 Sample Information Custody Information Date Time Matrix: DRINKING WATER Collected by: JK 11/09/17 14:00 Location Code: SPECIAL Received by: SW 11/09/17 14:22 Rush Request: Standard Analyzed by: see"By" below P.O.#: Laboratory Data SDG ID: GBZ38700 Phoenix ID: BZ38700 Project ID: 176 WINDSORVILLE RD Client ID: BATHROOM RU Parameter Result PQL DIL Units AL MCL MCLG Date/Time By Reference Escherichia Coli Absent 0 1 /100 mis 0 11/09/17 17:55 CB/CB SM922313-97 Total Coliforms Absent 0 1 /100 mis 0 11/09/17 17:55 CB/CB SM922313-04 Chloride 4.4 3.0 1 mg/L 250 11/10/17 B/E/G E300.0 Chlorine Residual <0.02 0.02 1 mg/L 4 11/09/17 18:26 O SM4500CI-G-00 Color,Apparent <1 1 1 Color Units 15 11/09/17 19:20 O SM2120B-01,-11 Nitrite as Nitrogen <0.004 0.004 1 mg/L 1 11/10/17 03:54 B/E/G E300.0 Nitrate as Nitrogen 2.86 0.01 1 mg/L 10 11/10/17 03:54 B/E/G E300.0 Odor at Room Temperature <1 1 1 T.O.N. 3 11/09/17 19:21 O SM215OB-97 pH 7.75 1.00 1 pH Units 6.5-8.5 11/10/17 05:28 RR/EG SM4500-H B-00 Sulfate 30.8 3.0 1 mg/L 250 11/10/17 B/E/G E300.0-2.1 Turbidity <0.20 0.20 1 NTU 5 11/09/1719:41 X SM213OB-01 Calcium 30.0 0.01 1 mg/L 11/11/17 MA E200.7 Iron <0.010 0.010 1 mg/L 03 11/11/17 MA E200.7 Hardness(CaCO3) 83.7 0.1 1 mg/L 11/13/17 E200.7 Magnesium 2.14 0.01 1 mg/L 11/11/17 MA E200.7 Manganese <0.001 0.001 1 mg/L 0.05 11/11/17 MA E200.7 Sodium 7.19 0.10 1 mg/L 28 11/11/17 MA E200.7 RUPQL=Minimum Reportable Level DW MCL=Maximum Potability Limit Sec Goal=Recommended Potability Limit NA=Not Applicable O/ For further interpretation or recommendations on treatment, please contact your local or Phyllis Shiller,Lab Director state health department. Please see last page for additional information. November 14,2017 Vert Page 3 of 7 Project ID: 176 WINDSORVILLE RD Phoenix I.D.: BZ38700 Client ID: BATHROOM Standard Water Testsdor Private Wells MCLG Secondary Parameter MCL Goal Information Arsenic 0.01 mg/L Arsenic occurs naturally in the environment and is a by-product of some agricultrual and industrial activities. It can enter the drinking water through the ground or as runoff into surface water sources. Calcium No Limit see Hardness Chloride 250 mg/L 250 mg/L Drinking water with chloride levels above 250mg/L may exhibit a salty taste. Elevated (in NY/CT) sodium and chloride levels usually occur due to road salt,water softeners, natural underground salt deposits, pollution from septic systems,or they are the result of a well's close distance the ocean or salt ponds. Chlorine No Limit Chlorine is used to disinfect drinking water. Residual Coliform 0 Coliforms are bacteria that are naturally present in the environment and used as an Bacteria indicator that other, potentially harmful, bacteria may be present. Fecal coliform and E. coli are bacteria whose presence indicates that water may be contaminated by human or animal wastes.Anytime the presence of Coliform is detected,the source must be determined. Color 15 CU 15 CU Color can be used to determine the presence of dissolved organic material or inorganic (in NY) contaminants such as metals. Copper 1.3 mg/L Copper enters drinking water primarily through plumbing materials. Exposure to copper (action level) may cause health problems. Fluoride 4.0 mg/L 2.0 mg/L Water supplies may contain some naturally occurring fluoride. Fluoride also enters 2.2 mg/L drinking water in discharge from fertilizer or aluminum factories.Also, many (in NY) communities add fluoride to their drinking water to promote dental health. Consult your dental professional for recommended levels. Hardness No Limit Hardness is a measure of the amount of calcium and magnesium in the water. In general, hardness values of less than 75 mg/L as calcium carbonate(CaCO3) represent soft water,and values above 150 mg/L CaCO3 represent hard water. Iron 0.3 mg/L 0.3 mg/L Iron is a naturally occurring element in groundwater and wells.While not considered a (in NY) health hazard, iron can cause staining of laundry and fixtures, and affect the taste and appearance of the water. Lead 0.015 mg/L The major sources of lead in drinking water are corrosion of household plumbing (action level) systems; and erosion of natural deposits. Lead enters the water through contact with the plumbing. Lead leaches into water through corrosion(a dissolving or wearing away of metal caused by a chemical reaction between water and your plumbing). Lead can leach into water from pipes, solder,fixtures and faucets(brass), and fittings.The amount of lead in your water also depends on the types and amounts of minerals in the water, how long the water stays in the pipes,the amount of wear in the pipes,the water's acidity(pH)and its temperature. Magnesium No Limit see Hardness Manganese 0.3 mg/L 0.05 mg/L Manganese is a trace element that occurs naturally in soil,water, and plants. (in NY) Manganese can produce dark brown or black staining on laundry and fixtures. Nitrate 10 mg/L Infants below six months who drink water containing nitrate in excess of the maximum contaminant level (MCL)could become seriously ill The major sources of nitrates in drinking water are runoff from fertilizer use; leaking from septic tanks, sewage; and erosion of natural deposits. Nitrite 1 mg/L Infants below six months who drink water containing nitrite in excess of the maximum contaminant level(MCL)could become seriously ill.The major sources of nitrite in drinking water are runoff from fertilizer use; leaching from septic tanks, sewage; and erosion of natural deposits. Vert Page 4 of 7 Project ID: 176 WINDSORVILLE RD Phoenix I.D.: BZ38700 Client ID: BATHROOM Standard Water Testso,for Private Wells Odor 3 TON 3 TON The presence of odor may indicate possible contaminants (in NY pH 6.5-8.5 pH is an indicator of the acid or alkaline condition of water.The range is 0-14,with 7 considered neutral. Below 7 is considered acidic, and above 7 is alkaline.The pH of drinking water is not a health concern, however,acidic water(low pH)can leach metals from plumbing systems. Sodium 250 mg/L 28/100 mg/L Elevated sodium and chloride levels usually happen because of road salt,water (in CT) (city I private softeners, natural underground salt deposits, pollution from septic systems, or they are advisory level the result of a well's close distance to the ocean or salt ponds. Contact your health in Cl) professional for recommended levels if you are on a low sodium diet. Sulfate 250 mg/L 250 mg/L Sulfate can be found in almost all natural water.The origin of most sulfate compounds (in NY) is the oxidation of sulfite ores,the presence of shales, or the industrial wastes. Sulfate has a mild laxative affect. Turbidity 5.0 NTU Turbidity has no health effects, but can interfere with disinfection and provide a medium for microbial growth.Turbidity is a measure of the cloudiness of water. It is used to indicate water quality and filtration effectiveness. MCL Maximum Contaminant Level (MCL) (Lower of):40 CFR Part 141; 40 CFR Part 143; CT Public Health Code 19-13-B102. The highest level of a contaminant that is allowed in drinking water. MCLs are enforceable standards. SEC GOAU Secondary DW Maximum Contaminant Level Goal (MCLG): (Lower of): 40 CFR Part 141; 40 CFR Part MCLGs 143; CT Public Health Code 19-13-B102. The level of a contaminant in drinking water below which there is no known or expected risk to health. MCLGs are non-enforceable public health goals. This guidance document is based on information provided by EPA National Primary and Secondary Drinking Water Regulations, and is provided as a tool to help interpret your drinking water test results. Contact your local health department for additional guidance and information. Additionally, you may call the Safe Drinking Water Hotline at 1-800-426-4791 Additional For public water systems, chloride has a maximum contaminant level (MCL) of 250 mg/L. Comments The regulatory hold time for Chlorine is immediately. This Chlorine was performed in the laboratory and may be considered outside of hold-time. The regulatory hold time for pH is immediately. This pH was performed in the laboratory and may be considered outside of hold-time. This report must not be reproduced except in full as defined by the attached chain of custody Ver 1 Page 5 of 7 - Cooler Yes No Coolant: IPK ICE N CHAIN OF CUSTODY RECORD Temp "C Pg or Pl l O 587 East Middle Turnpike,P.O.Box 370.Manchester,CT 08040 l 3 Email:info@phoenWabs.com Fax(860)64"823 Environmental Laboratories, Inc. Client Services (860) 645-8726 Residential Drinking Water Test Customer. 1`7 Address where sample was collected: Address: S L p�„o-� [ S Phone#: ZU~S C OAA Fax#: Client Sample-Information-IdentliicaUon samplers 1 Analysis Signature o`Ctyyyu Date: Request 4 J Matrix Code: DW=Drinking Water GW=Ground WaterSW=Surface Water WW=Waste Water SE--Sediment SL=Sludge S=So1/Solld W=Wipe Other `ti' ti PA_ PHOENIXCustomer Sample Sample Date Time SAMPLE* Identification Matrx Sampled Sam 2 i Relinquished c ted b : Dat : Time: Ice down or keep samples Q 2-5•C(35-41'F) Samples should be delivered to the lab within 12 hours(24 hours max)from time of sampling Corn Is Special Requirements or Regulations: Turnaround: Drinking Water Analysis List ��SS ❑ t Day* The report will include the following analysis: ❑ 2 Days. 0 3 Days* pH Color Sulfate ❑Standard Hardness Odor Iron&Manganese Other Chloride Turbidity Coliiforrn Bacteria M Sodium Nitrite&Nitrate Chlorine rn •SURCHARGE APPLIES 4 Tuesday, November 14,2017 Sample Criteria Exceedances Report Criteria: CT:DW GBZ38700-SPECIAL State: CT RL Analysis SampNo Acode Phoenix Analyte Criteria Result RL Criteria Criteria Units ***No Data to Display*** Phoenix Laboratories does not assume responsibility for the data contained in this report. It is provided as an additional tool to identify requested criteria exceedences. All efforts are made to ensure the accuracy of the data(obtained from appropriate agencies). A lack of exceedence information does not necessarily suggest conformance to the criteria. It is ultimately the site professional's responsibility to determine appropriate compliance. Page 7 of 7