HomeMy WebLinkAbout20170926112914 ZONING COMPLIANCE FOR SMALL STRUCTURES �('k
(Sheds and detached decks 200 sq. ft. and smaller)
Address of Proposed Structure: IQ ll, Zone: 11 ao os
Name of Owner: r in-e I S.� k-e i C� 1-42— GIS PIN: o 000 i j
Phone Number: L%LO)r Uq �r OQ.6 Application #:
ll--
1. Name of Applicant: VI -P—S l V\
Address: �aT
Phone Number: ( FS(.o ao q - 3C)0 6
2. Structure cannot exceed 200 square feet.
TYPE OF STRUCTURE: V SHED DECK not to exceed 30"from grade)
DIMENSIONS OF PROPOSED STRUCTURE: �I
3. A Class D survey must be submitted with the application showing the property lines, all other
buildings and the location of the proposed structure.
4. Is the property served by a septic system? Yes No If yes, the applicant must
complete and submit a B100a Application to the Health Department for review and approval.
The undersigned hereby permits Town staff to enter onto and inspect this property during
reasonable hours for the purpose of reviewing this application and to determine final compliance
once construction is completed.
I, the undersigned, acknowledge that the above information is true to the best of my knowledge
and that the above requirements re un erstood
Applicant Signature: 7�1/' Date:
'? 1(9j 43� 1_7
Owner Signature: Date:
*****************************************************************
Reviewed and approved by: Date:
Zoning Enforcement Officer
Reviewed and approved by: Date:
Environmental Health Officer
cc: Assessor
Building File
04/15/14
(ZX( (o
Dutch Colonial Storage Building
VARIES i, VARIES
30YEAK
- —_ - - ARCHITECTURAL
— — - _ ASPHALT SHINGLES
END VENT
- - r EACH SIDE
,
SINGLE HUNG
ALUMINUM
WINDOW
L� 51DING VARIES:
! 'DURATEMP°
TEXTURE 1-11
op,HORIZONTAL
OVER'/2"CDX If
FRONT SIDE
*shown with standard double doors and standard windows
30 YEAR ARCHITECTURAL
�— ASPHALTSHINGLE5
'/2"CDX PLYWOOD ROOF SHEATHING
'/2"PLYWOOD
GUSSETS BOTH
.2:,x4„ 51DES
RAFTERS
16"O.C.
2"x 6"RAFTERS
TAPERED TO 2"x 4"
16"O.C. ALUM.DRIP EDGE
Q (2)2"x4"TOP PLATE FIN15HEDSOFFIT
Z 51DING VARIES:
y 59'DURATEMPG
TEXTU RE 1-11
W 3/a"WEATHER&ROT RESISTANT op,HORIZONTAL
PRE55URETREATED OVER/z CDX
5-PLY PLYWOOD
2"x4"STUDS
2"x 4"PRESSURE TREATED 16"O.C.
FLOOR J015T516"O.C.
+= 12'WIDE and LARGER:12"O.C.
PRESSURETREATED
4"x4"BEAMS
_ 6 WIDE:2 BEAMS
��=((�IL�C—:((L�tt r;a I,�1ELLL'l (L61=11 t 6 C=—kL6(=._. Ltff-- 1('('7t2i'8'WIDE:3 BEAMS
SECTION 10'&12'WIDE:513EAM5
14'WIDE:7 5EAM5
KLOTER FARMS NOTES:
� Building Code-conforms to Designed to resist wind gust of
�■ I�fi — www.KioterFarms.com 2012 International Residential 120 MPH for 3 seconds
Code table R301.5 Design wind force-34psf
860-871-1048 800-289-3463 Fax 860-871-1117 Design snow load-40 psf
216 West Road (Rte 83), Ellington, CT 06029 Design floor load-100 psf
Reino E. Hyyppa & Associates
CIVII Engineers
Glastonbury, Connecticut
LE FBI--
4r
C1.
I W
L
0
(k 14
,NOTE: Lot lines from map on file in
Town Clerk's Office entitled., ,plot plan
S ec tion e� Pleasant Valley Homes
South Windsor, Conn."
Scale 111- 401 Date s A-20 'ZONE
Map No. 220-78-1 Rev.-?---&-6-�.by R e i n o E.
Hyyppa & Associates Glastonbury, CT.
PkDEPAP-F-0 FOR
I hereby certify thit this rnaD and survey were prepared i(i
-2 survey as defined
PLEASANT V4.LLF-Y WOMES
ecordance with the standards of a Class A
i the existing Code of,Pra-:Iice for Standards of Accuracy of 50 UTl4 \NI WDSOIZI r-ON I'j
urveys and Maps, adopted by the Connecticut Association of r:;oCALE- I"-c 40' IDA
and Surveyors, kw-
?s-b-e,-N 04-LocArIn o,3 C A A-4(440
&-4-ft �l,�,e,e CUAc,(-CD 43-,-19 115