HomeMy WebLinkAboutPump Info 178 Chapel Road PUMP SYSTEM PLAN REVIEW AND INSPECTION CHECKLIST
ADDRESS: A
DATE: L �G
PUMP CHAMpER SPECS:
CAPACITY: / 7 0 0 gallons,TYPE: :To
if WATERTIGHT CERTIFIED(in high groundwater conditions)—TESTED FOR LEAKAGE?
MANHOLE TO GRADE—GRADED TO AVOID SURFACE WATER INFILTRATION?
WATERTIGHT RISERS
T; RISER(S)24"DIA.OVER ACCESS MANHOLE IF CNA MBER>24 TNT T-MS DEEP
^' CHAMBER,RISER AND COVER ASSEMBLY-H-20 LOAD RATED FOR VEHICLE TRAVEL AREAS
EFFLUENT PUMP SPECS:
PROPER PUMP:MAKE AND MODEL: HP:
! EFFLUENT PUMP APPROVED FOR SEWAGE DISPOSAL SYSTEM USE(BY MANUFACTURER)
SINGLE PUMP WITH EMERGENCY STORAGE(MINIMUM 24.HOUR FLOW)OR
DU. ALA.1,FI'sR3+lATINO PUWS-
YSTEM TOTAL DYNAMIC HEAD: _ (CALCULATE)
PUMP RATED FOR DESIGN FLOW AT TOTAL DYNAMIC HEAD FOR SYSTEM DESIGN?
PUMP ASSEMBLY:
PROPER PUMP INSTALLATION-IN CHAMBER:(location,elevation,plumbing)
i J ACCESSIBLE PUMP DISCONNECT-UNION COUPLING OR OTHER--
ACCESSIBLE PUMP LIFT CHAIN/ROPE
CHECK VALVE PROVIDED ON PUMP DISCHARGE LINE (unless not required by pump manufacturer)
PUMP ON/OFF SWITCH TYPE:FLOAT SWITCHES: 7ANSDUCERS:
VOLUME DOSING OR TIME DOSING r'a� {
PUMP CYCLE VOLUME: GALLONS�OSING SPECS:
pump on elevation/height:
pump off elevation/height: (CALCULATE)
PUMP CYCLE VOLUME APPROPRIATE FOR TEACHING SYSTEM STORAGE CAPACITY?(CALCULATE)
V ALARM S` TCIi TYISE:FLOAT SWITCHES: TRANSDUCERS:
EMERGENCY STORAGE VOLUME: (.� � �' gallons(MINIMUM 24 HOUR FLOW REQUIRED)
alarm on elevation/height: (CALCULATE)
AUDIBLE ALARM LOCATION AND SPECIFICATIgNS(TYPE)�,
CONTROL PANEL: NA_ or SPECS: �Uf A i�i
TIME DOSING-TINIER SETINGS(IF APPLICABLE)
FORCE MAIN SPECS:
FORCEMAIN PIPE TYPE: `1 _ ,DIAMETER: inches,LENGTH feet
FORCEMAIN OUTLET AT LEACHING SYSTEM NOT SUBMERGED
FREEZE PROTECTION PROVIDED BY DEEP BURIAL(BELOW FROST LINE)OR
FORCEMAIN WEEPHOLE/DRAIN HOLE WITHIN CHAMBER
VOLUME OF FORCEMAIN DRAINING BACK TO PUMP CHAMBER DOES NOT CAUSE EXCESSIVE
PUMP CYCLING? (CALCULATE)
i d PUMP ON/OFF SWITCH SETTINGS VERIFIED
PUMP TEST
ALARM TEST
ALARM ON SEPARATE CIRCUIT FROM PUMP
Contact the local building official to discuss the electrical permit and inspection requirements.
All electrical work associated with the power source and installation of the pump,alarm,control
panels,switches,wires,conduits,etc.should be performed by a qualified electrician and must be
inspected by a building inspector or electrical inspector.
ELECTRICITY,WATER AND SEWER GASSES CAN BE A VERY DANGEROUS COMBINATION—
MAKE SURE THE JOB IS DONE RIGHT AND DONE SAFELY!!!
3/2009