Loading...
HomeMy WebLinkAboutWell Correspondence 107 Troy Road 5Aquatek Labs 3 Research Drive-Woodbridge, CT 06525 Water Analysis Report TEST ID: E061016015 DATE SAMPLED: 6/9/2016 TO: INTELLISPECT LLC. 728 SAMPLE POINT: BATHROOM NO TREATMENT SAMPLED BY: JOHN NOLAN PROPERTY LOCATION: 107 TROY ROAD - SOUTH WINDSOR , CT BACTERIA ABSENT PRESENT LIMITS REF METHOD Coliform(Total) G ❑ ABSENT P SM 9223 E.Coli(Fecal) G ❑ ABSENT P SM 9223 Chlorine(Total) G ❑ ABSENT SM 4500-CI G PHYSICAL PARAMETERS RESULT UNITS LIMITS MRL REF METHOD pH 7.1 SU 6.4-10 S 0 SM 4500-H B * Turbidity 12.00 NTU 5 0.10 SM 2130 B Color 20 CU 15 S 5 SM 2120 B Odor 1 TON 2 S 0 SM 2150 CHEMICALS RESULT UNITS LIMITS MRL REF METHOD Flouride ND mg/L 4 P 0.3 EPA 300.0 Chloride 4 mg/L 250 P 3 EPA 300.0 Nitrite Nitrogen ND mg/L 1 P 0.1 EPA 300.0 Nitrate Nitrogen ND mg/L 10 P 1 EPA 300.0 Sulfate 353 mg/L 250 S 4 EPA 300.0 Calcium 96 mg/L NONE 0.5 SM 3111 B Magnesium 18 mg/L NONE 0.5 SM 3111 B * Hardness 312 mg/L 200 S 4 SM 2340 B Sodium 13.8 mg/L 100 S 0.5 SM 3111 B Copper ND mg/L 1.3 S 0.04 SM 3111 B " Iron 2.02 mg/L 0.3 S 0.04 SM 3111 B " Manganese 0.16 mg/L 0.05 S 0.04 SM 3111 B Lead ND mg/L 0.015 P 0.005 SM 3113 B RADON WATER SINGLE RESULT UNITS LIMITS MRL REF METHOD Radon Water Single 132 pCi/L 5000 S 51 SM 7500-RN CONCLUSION: Based on the above results, this water was safe for drinking purposes at the time of collection. COMMENTS:Filtration and/or conditioning are recommended. P=Primary limit,used to judge potability S=Secondary limit,recommended but not required / MRL=Minimum Reportable Level Reportable Level *Limit exceeded Michael F. Berman, Ph.D. ND=None Detected Laboratory Director CT License#PH-0466,Aquatek Labs R=Reference Lab Work Page 1 of 1 for test# E061016015