HomeMy WebLinkAboutPools Inspection 001 Saint Marc Circle dye Routine Inspection ❑Indoor Pool
l�o ,a,E'�� Town of South Windsor—Health Department
P ❑ Re-inspection ❑Outdoor Pool
1540 Sullivan Avenue,S.Windsor,CT 06074 ❑Complaint ❑Wading Pool
Phone: 860-644-2511 x248 Fax: 860-644-7280 ❑Other: ❑Whirlpool/Spa
Public Swimming Pool Inspection Report ++ 44
Name of Facility: �\ Inspection Date:� I
Address: C k(Cl(-A- Phone: 331Z-
items marked with an X indicate non-compliance with CT Public Health Code(Section 14-13-833b). Violations must be corrected by the listed compliance date. __ V
a-4 Life Saving Equipment b-12 Vacuuming
Ring buoy <15" inner diameter,attached to Pool vacuumed to maintain cleanliness
50ft length of%" line
Life poEe/shepard's crook with blunted ends,a b-13 Accessibility to Pool Area
minimum of 12ft in length Outdoor pools surrounded by barrier(>4ft)
'Outdoor pool entry gates self-closing and self
b-1 Pool Construction
li/ latching
Pool in good repair Pool access restricted when pool is closed
b-2 Supervisory Personnel
Knowledgeable pool supervisor onsite b-14 Lifeguards
List of personnel provided to Health Dept. / Warning signs if no lifeguard on duty(letters
b-4 Pool Water Clarity >4" high)
6"secchi disk at pool bottom visible / Warning signs visible from all entry points in
b-5 Pool Water Disinfection S/ pool area
b-15 First Aid Kit
Automatic Feeder Used Kit filled, ready for use,materials current
>0.8 mg/liter Free Chlorine Amer. Red Cross 24-unit first aid kit or equiv.
b-5, b-6, Test Kits b-16 Emergency Telephone
DPD Test Kit onsite (for disinfectant and pH) Telephone readily available in pool area
b-6 Pool Water pH b-17 Signs
Value between 7.2 and 7.8 "All persons shall bathe with water and soap
b-7 Records and Testing "
before entering pooE
Residual disinfectant& pH tested prior to daily "Anyone having a communicable disease shall
opening not use the pool"
Daily pool testing records kept "Spitting, or blowing the nose in the pool is
b-8 Decks, Dressing,Toilet&Shower Rooms V prohibited"
Clean,good repair,well ventilated "Running, boisterous or rough play is
0.5%chlorine cleaning solution for floors �/
prohibited"
Shower water 90—105 degrees F b-18 Emergency Communications
Adequate toilet facilities Directions to nearest telephone and first-aid kit
b-9 Equipment rooms/areas&Equipment posted at entrance
Maintained in good repair,clean/sanitary Telephone numbers(print>.25") of police,fire,
Skimmers,gutters,strainer baskets clean and in ✓ hospital and EMS
good repair b-19 Registration
Drain grates compliant Name of owner or owner's agent, address and
b-10 Deck Equipment `✓ location on file
Handrails provided on steps,stepholes,and c-1 Depth Markers
ladders Markers on rim at min and max depth and
Equipment properly secured V points of slope change
b-11 Pool Chemical Storage Markers visible from po ffyand from within
Stored in a cool, dry,clean,well-ventilated area
pool
f/ Containers stored tightly closed
Public Swimming Pool Inspection Report
2
c-2 Lifeguard stands Comments:
Lifeguard stand raised at least 4ft 9 � uom�n
Lifeguard stand located pool side adjacent to "'—
deep end
c-4 Sign
"No diving is permitted off the deck into n ou,-Q lm��L �X U+�,(1 r�Q
shallow areas of the pool"
Additional Requirements for Public Spas: AA A
�WO�6
e-1 Pool Water Disinfection 1A�
Free available chlorine residual>1.0 mg/liter
when spa in use r iL)l
e-2 Pool Water Temperature
Water temperature shall not exceed 104
degrees F
e-3 Depth Markers
Minimum 2 markers located on rim or
adjacent to pool
e-4 Precaution Signs
"Elderly persons and those suffering from
Heart Disease,Diabetes, High or Low Blood
Pressure,shall not enter the spa"
"Unsupervised use by children is prohibited"
"Do not use while under the influence of
alcohol/drugs"
"Do not use alone"
"Observe a reasonable time limit(preferably
less than 15 min.): long exposures may result
in nausea, dizziness,or fainting"
e-5 Oils, Body Lotions,and Soaps
Oils, body lotions&soaps must be removed
prior to spa use
XPool Supervisor:
(Print Name)
(Sig lkur
Health Inspector: AJITitle: 'rJ ,• C.-Q
( ignature)
DATE OF COMPLIANCE: Re-inspection Required: ❑YES UP 0
01,
S.Windsor—April 2011