HomeMy WebLinkAboutPools Inspection 575 Pleasant Valley Oar, 9kRoutine Inspection
Town Of South Windsor—Health Department 0 Re-inspection WDutdoor Pool
1540 Sullivan Avenue,S.Windsor,CT 06074
0 Complaint �Mading Pool
Phone: 860-6 4-2511 x248 Fax: 860-644-7280
SOR.�� 0 Other: 0 Whirlpool/Spa
Public Swimming Pool Inspection Report
Name of Facility: "/.6p Inspection Date:
Address: Phone:
Items marked with an x indicate non-compliance with Cr Public Health ode(Section 19-13-B33b). violations must be corrected by the listed compliance date.
a-4 Life Saving Equipment v b-12 T Vacuuming
I / Ring buoy <15"inner diameter,attached to pool vacuumed to maintain cleanliness
V 50ft length of%" line
b-13 Accessibility to Pool Area
Life pole/shepard's crook with blunted ends,a
minimum of 12ft in length Outdoor pools surrounded by barrier(>4ft)
b-1 Pool Construction Outdoor pool entry gates self-closing and self latching
✓ Pool in good repair �
Pool access restricted when pool is closed
b-2 Supervisory Personnel
r/ Knowledgeable pool supervisor onsite b-14 Lifeguards
I/ List of personnel provided to Health Dept. Warning signs if no lifeguard on duty(letters
b-4 Pool Water Clarity >4" high)
6" secchi disk at pool bottom visible Warning signs visible from all entry points in
b-5 Pool Water Disinfection pool area
b-15 First Aid Kit
Automatic Feeder Used Kit filled, ready for use,materials current
>0.8 mg/liter Free Chlorine
AT r. Red Cross 24-unit first aid kit or equiv.
b-5, b-6 Test Kits b-16 ,emergency Telephone
DPD Test Kit onsite (for disinfectant and pH) Telephone readily available in pool area
b-6 Pool Water pH b-17 Signs
Value between 7.2 and 7.8 "All persons shall bathe with water and soap
b-7 Records and Testing efore entering pool"
Residual disinfectant& pH tested prior to daily 'Anyone having a communicable disease shall
Qll opening not use the pool"
Daily pool testing records kept / "Spitting,or blowing the nose in the pool is
b-8 Decks,Dressing,Toilet&Shower Rooms ✓ prohibited"
Clean,good repair,well ventilated / "Running, boisterous or rough play is
0.5%chlorine cleaning solution for floors r/ prohibited"
Shower water 90—105 degrees F b-18 Emergency Communications
Adequate toilet facilities Directions to nearest telephone and first-aid kit
b-9 Equipment rooms/areas&Equipment posted at entrance
Maintained in good repair, clean/sanitary Telephone numbers (print>.25")of police,fire,
Skimmers, gutters, strainer baskets clean and in hospital and EMS
good repair b-19 Registration
Drain grates compliant Name of owner or owner's agent, address and
b-10 Deck Equipment location on file
Handrails provided on steps, stepholes, and c-1 Depth Markers
ladders Markers on rim at min and max depth and
Equipment properly secured l� points of slope change
b-11 Pool Chemical Storage Markers visible from pool deck and from within
Stored in a cool,dry,clean,well-ventilated area pool
Containers stored tightly closed
I
Public Swimming Pool Inspection Report
2
c-2 Lifeguard stands Comments:
Lifeguard stand raised at least 4ft .
Lifeguard stand located pool side adjacent to
L � G
deep end
c-4 Sign
"No diving is permitted off the deck into
shallow areas of the pool"
Additional Requirements for Public Spas:
q
e-1 Pool Water Disinfection
Free available chlorine residual >1.0 mg/liter
when spa in use L
e-2 Pool Water Temperature
Water temperature shall not ex ed 104 Y ce �
degrees F
e-3 Depth Markers
Minimum 2 markers loc ed on rim or
adjacent to pool
e-4 Precaution Signs
"Elderly persons d those suffering from
Heart Disease, - betes, High or Low Blood
Pressure, sha not enter the spa"
"Unsupervi d use by children is prohibited" V
"Do not 94 while under the influence of r-
alcohol rugs"
"Do t use alone" r
"O erve a reasonable time limit (preferably
I s than 15 min.): long exposures may result
nausea,dizziness,or fainting"
e-5 Oils,Body Lotions,and Soaps
Oils, body lotions&soaps must be removed �1
prior to spa use
Pool Supervisor: Date:
(Print Name)
(Signature)
1YHealth Inspector: Title:
gnature)
DATE OF COMPLIANCE: Al I?L Re-inspection Required fE5 8 NO
S.Windsor—April 2011