HomeMy WebLinkAboutPools Inspection 001 Misty Meadow Lane Routine Inspection 6 Indoor Pool
Town of South Windsor-Health Department kw
0 Re-inspection Outdoor Pool
w .
1540 Sullivan Avenue,S.Windsor,CT 06074 A Complaint 6 Wading Poo{
Phone: 860-644-2512 x248 Fax: 860-644-7280
030R•Co 0 Other: 6 Whirlpool/Spa
IL
Public Swimming Pool Inspection Report
Name of Facility: / e Olc) Inspection Date:
/,=;44 Zaalz
Address:^ / STD/ y' r�J G�r� Phone:
Items marked with an X indicate non-compliance with CT Public Health Code(Section 19-13-633b). Violations must be corrected by the listed compliance date.
a-4 Life Saving Equipment b-12 Vacuuming
Ring buoy <15" inner diameter,attached to
Pool vacuumed to maintain cleanliness
$Oft length of%" line
Life pole/shepard's crook with blunted ends, a b-13 . Accessibility to Pool Area
minimum of 12ft in length Outdoor pools surrounded by barrier(>4ft)
� Outdoor pool entry gates self-closing and self
b-1 Pool Construction
latching
Pool in good repair
Pool access restricted when pool is closed
b-2 Supervisory Personnel
Knowledgeable pool supervisor onsite b-14 Lifeguards
1,,-"' List of personnel provided to Health Dept. / Warning signs if no lifeguard on duty(letters
b-4 Pool Water Clarity V >4" high)
'I/ 6"secchi disk at pool bottom visible Warning signs visible from all entry points in
pool area
b-5 Pool Water Disinfection b-15 First Aid Kit
Automatic Feeder Used Kit filled, ready for use, materials current
>0.8 mg/liter Free Chlorine Amer. Red Cross 24-unit first aid kit or equiv.
b-5, b-fi Test Kits b-16 Emergency Telephone
�./ DPD Test Kit onsite (for disinfectant and pH) Telephone readily available in pool area
b-6 Pool Water pH b-17 Signs
Value between 7.2 and 7.8 "All persons shall bathe with water and soap
b-7 Records and Testing Lee"" before entering pool"
Residual disinfectant&pH tested prior to daily "Anyone having a communicable disease shall
opening v not use the pool"
Daily pool testing records kept "Spitting, or blowing the nose in the pool is
b-8 Decks,Dressing,Toilet&Shower Rooms V/1" prohibited"
jCkan good repair, well tlat-ed— _"Running, boisterous or rough play is
OSTo cb dff�e cleaning solution for floors! prohibited"
Shower water 90-105 degrees -- / b-18 Emergency Communications
Adequate toilet facilities Directions to nearest telephone and first-aid kit
b-9 Equipment rooms/areas&Equipment posted at entrance
Maintained in good repair,clean/sanitary Telephone numbers (print>.25")of police, fire,
Skimmers,gutters,strainer baskets clean and in hospital and EMS
good repair b-19 Registration
",, , Drain grates compliant Name of owner or owner's agent, address and
b-10 Deck Equipment location on file
Handrails provided on steps, stepholes, and c-1 Depth Markers
LX ladders Markers on rim at min and max depth and
Equipment properly secured points of slope change
b-11 Pool Chemical Storage Markers visible from pool deck and from within
Stored in a cool,dry, clean,well-ventilated area pool
Containers stored tightly closed
Public Swimming Pool Inspection Report
2
c-2 Lifeguard stands Comments:
Lifeguard stand ed at least 4ft � � ��.( (G / —•Atd/�r
Lifeguard 5add located pool side adjacent to
deep end
c-4 Sign
✓ "No diving is permitted off the deck into � �, yQ ✓, �, _
shallow areas of the pool"
Additional Requirements for Public Spas: f
e-1 Pool Water Disinfection
Free available chlorine residual>1.0 mg/lit
when spa in use G
e-2 Pool Water Temperature v��c.k.�r�
Water temperature shall not exce d 104 l /
degrees F
e-3 Depth Markers
Minimum 2 markers locat on rim or
adjacent to pool
e-4 Precaution Signs -~
"Elderly persons an hose suffering from
Heart Disease,Diab es, High or Low Blood
Pressure,shall tenter the spa" f
"Unsupervise use by children is prohibited"
"Do not us hile under the influence of
alcohol/d gs" ICA
"Do no use alone"
G
It
Os e a reasonable time limit(preferably
les han 15 min.): long exposures may result <�7
in ausea,dizziness,or fainting"
e-5 ils, Body Lotions,and Soaps
Oils, body lotions&soaps must be removed
prior to spa use -
Pool Supervisor: C Dater
(Print Nam
77
ignature)
Health Inspecto : � Title:
/ ignature)
DATE OF COMPLIANCE: �� � /(� Re-inspection Required: 8 YES A NO
S.Windsor—April 2011