HomeMy WebLinkAboutPools Inspection Sandstone Drive 11
elkutine Inspection 0 Indoor Pool
Town of South Windsor—Health Department __
0 Re-inspection @,6utdoor Pool
W5 1540 Sullivan Avenue,S.Windsor,CT 06074 0 Complaint 0 Wading Pool
phone: 860-644-2511 x248 Fax: 860-644-7280 0 Other: 0 Whirlpool/Spa
Public Swimming Pool Inspection Report f
Name of Facility: vo A.0, Inspection Date:
Address: S G r2 3�rb Phone: U - �1b Sr 3 300
Items marked with an x indicate non-compliance with C7 Public Health Code(Section 19-13-633b). Violations must be corrected by the listed compliance date.
a-4 Life Saving Equipment b-12 Vacuuming
Ring buoy <15" inner diameter,attached to Pool vacuumed to maintain cleanliness
50ft length of%" line b-13 Accessibility to Pool Area
Life pole/shepard's crook with blunted ends,a Outdoor pools surrounded by barrier(>4ft)
1/ minimum of 12ft in length
b-1 Pool Construction Outdoor pool entry gates self-closing and self
latching
Pool in good repair
f Pool access restricted when pool is closed
16-2 Supervisory Personnel
b-14 Lifeguards
Knowledgeable pool supervisor onsite
List of personnel provided to Health Dept. Warning signs if no lifeguard on duty(letters
cr >4" high)
b-4 Pool Water Clarity Warning signs visible from all entry points in
6"secchi disk at pool bottom visible pool area
b-5 Pool Water Disinfection b-15 First Aid Kit
Automatic Feeder Used
,i Kit filled,ready for use,materials current ,
>0.8 mg/liter Free Chlorine v Amer.Red Cross 24-unit first aid kit or equiv.
b-5, b-6 Test Kits b- 6 Emergency Telephone j
DPD Test Kit onsite (for disinfectant and pH) Telephone readily available in pool area
b-6 Pool Water pH b-17 Signs
Value between 7.2 and 7.8 "Ali persons shall bathe with water and soap
b-7 Records and Testing I/ before entering pool"
Residual disinfectant&pH tested prior to daily "Anyone having a communicable disease shall
opening V not use the pool"
Daily pool testing records kept "Spitting,or blowing the nose in the pool is
b-8 Decks,Dressing,Toilet&Shower Rooms prohibited"
Clean, good repair, well ventilated "Running, boisterous or rough play is
0.5%chlorine cleaning solution for floors prohibited"
Shower water 90--105 degrees F b-18 Emergency Communications
Adequate toilet facilities Directions to nearest telephone and first-aid kit
b-9 Equipment rooms/areas&Equipment posted at entrance
Maintained in good repair,clean/sanitary Telephone numbers(print>.25") of police,fire,
/ Skimmers,gutters,strainer baskets clean and in v1 hospital and EMS
�/ good repair b-19 Registration
t/ Drain grates compliant Name of owner or owner's agent,address and
b-10 Deck Equipment `� location on file -
J Handrails provided on steps, stepholes,and c-1 Depth Markers
ladders Markers on rim at min and max depth and
Equipment properly secured points of slope change
b-11 Pool Chemical Storage Markers visible fro poo nd from within
Stored in a cool, dry,clean,well-ventilated area pool
Containers stored tightly closed
Public Swimming Pool Inspection Report
2
c-2 Lifeguard stands Comments:
Lifeguard stand raised at least 4ft
Lifeguard stand located pool side adjacent to f
deep end -
c-4 Sign
- ✓ "No diving is permitted off the deck into
shallow areas of the poop'
Additional Requirements for Public Spas:
e-1 Pool Water Disinfection
Free available chlorine residual>1.0 mg/liter
when spa in use y'f'VA
e-2 Pool Water Temperature
Water temperature shall not exceed 104
degrees F
e-3 Depth Markers
Minimum 2 markers located on rim or
adjacent to pool -
e-4 Precaution Signs -
"Elderly persons and those suffering from
Heart Disease,Diabetes, High or Low Blood
Pressure,shall not enter the spa"
"Unsupervised use by children is prohibited"
"Do not use while under the influence of
alcohol/drugs"
"Do not use alone"
"Observe a reasonable time limit(preferably
less than 15 min.): long exposures may result _
in nausea, dizziness,or fainting"
e-5 Oils, Body Lotions,and Soaps
Oils, body lotions&soaps must be removed
prior to spa use
Pool Supervisor: c- Date:
(Print Name)
(Si atu 1
Health Inspector: ALA 6
Title:
(Signature)
DATE OF COMPLIANCES _ Re-inspection Required: AYES ONO
S.Windsor—April 2011