HomeMy WebLinkAboutPools Inspection Twin Circle Drive oµs� die outine Inspection 0 Indoor Pool
Town Of South Windsor Department
� 4'` �•` 0 Re-inspection door Pool
1540 Sullivan Avenue,S.Windsor,CT 06074 9 Complaint 0 Wading Pool
Phone: 860-644-2511 x248 Fax: 860-644-7280 0 Other: 0 Whirlpool/Spa
Public Swimming Pool Inspection Report ++
Name of Facility: . Inspection Date: SJI
Address: - Phone:
Items marked with an X indicate non-compliance with Cr Public Health Code(Section 19-13-833b). Violations must be corrected by the listed compliance date.
a-4 Life Saving Equipment b-12 ..Vacuuming
Ring buoy <15" inner diameter, attached to
Pool vacuumed to maintain cleanliness
50ft length of%" line
Life pole/shepard's crook with blunted ends,a b-13 Accessibility to Pool Area
minimum of 12ft in length � Outdoor pools surrounded by barrier(>4ft)
f Outdoor pool entry gates self-closing and self
b-1 Pool Construction
latching
Pool in good repair l/
Pool access restricted when pool is closed
b-2 Supervisory Personnel
Knowledgeable pool supervisor onsite b-14 Lifeguards
Warning signs if no lifeguard on duty(letters
r/ List of personnel provided to Health Dept. V' >W high)
b-4 Pool Water Clarity
/ Warning signs visible from all entry points in
6" secchi disk at pool bottom visible _
pool area
b-5 Pool Water Disinfection ✓
b-15 First Aid Kit
Automatic Feeder Used Kit filled, ready for use, materials current
>0.8 mg/liter Free Chlorine Amer. Red Cross 24-unit first aid kit or equiv.
b-5, b-6 Test Kits
b-16 Emergency Telephone
DPD Test Kit onsite(for disinfectant and pH) Telephone readily available in pool area
b-6 Pool Water pH b-17 Signs
Value between 7.2 and 7.8 "All persons shall bathe with water and soap
b-7 Records and Testing before entering pool"
Residual disinfectant&pH tested prior to daily "Anyone having a communicable disease shall
✓
opening V not use the pool"
Daily pool testing records kept / "Spitting,or blowing the nose in the pool is
b-8 Decks,Dressing,Toilet&Shower Rooms " prohibited"
V- Clean,good repair,well ventilated "Running, boisterous or rough play is
0.5%chlorine cleaning solution for floors prohibited"
Shower water 90—105 degrees F b-18 Emergency Communications
Adequate toilet facilities Directions to nearest telephone and first-aid kit
b-9 Equipment rooms/areas&Equipment posted at entrance
Maintained in good repair, clean/sanitary / Telephone numbers(print>.25")of police,fire,
✓ Skimmers,gutters,strainer baskets clean and in �/ hospital and EMS
good repair b-19 Registration
Drain grates compliant Name of owner or owner's agent,address and
16-10 Deck Equipment ✓ location on file -
Handrails provided on steps, stepholes,and Depth Markers
ladders Markers rim in and max depth and
Equipment properly secured points of s ope change
b-11 Pool Chemical Storage Markers visible from p and from within
i/ Stored in a cool,dry, clean,well-ventilated area pool
Containers stored tightly closed /�
Public Swimming Pool Inspection Report
z
c-2 Lifeguard stands Comments:
Lifeguard stand raised at least 4ft {�o ✓ Alt,{
Lifeguard stand located pool side adjacent to
deep end 0 y` pfl
c-4 Sign
"No diving is permitted off the deck into a �.IIJS
shallow areas of the pool" tt ��
Additional Requirements for Public Spas:*A
V-PdA
e-1 Pool Water Disinfection
Free available chlorine residual >1.0 mg/liter [when spa in use Y}p S4 rl A✓P
_- a-2 Pool Water Temperature
Water temperature shall not exceed 104
degrees F
e-3 Depth Markers
Minimum 2 markers located on rim or L Opt /5
adjacent to pool
e-4 Precaution Signs .� ��
"Elderly persons and those suffering from
Heart Disease,Diabetes, High or Low Blood
Pressure,shall not enter the spa"
"Unsupervised use by children is prohibited"
"Do not use while under the influence of
alcohol/drugs"
"Do not use alone"
"Observe a reasonable time limit(preferably
less than 15 min.): long exposures may result
in nausea;dizziness, or fainting"
e-5 Oils, Body Lotions,and Soaps
Oils, body lotions&soaps must be removed
prior to spa use
Pool Supervisor: r Date: C
(Print Name)
A U
(Signature)
Health Inspector: Title: hu_ s v,po cl((J�-
(Signature)
DATE OF COMPLIANCE: s- z 3 1 u-- Re-inspection Required: OYES ONO _
S.Windsor—April 2011