HomeMy WebLinkAboutSeptic Repair 5615 Ellington Road Town of South Windsor -- Health Department 1540 Sullivan Avenue, South Windsor, CT 06074-2786 �yLSQR,Cn�, Phone: 860-644-2511 ext. 248 Fax: 860-644-7280 DESIGN RECOMMENDATIONS FOR REPAIR OF SEWAGE DISPOSAL SYSTEM PROPERTY OWNER(S): Luthfa Jilu STREET ADDRESS: 2615 Ellington Road, South Windsor RESIDENTIAL (#of Bedrooms): 4 SEPTIC TANK: Install 1,000 gallon two-compartment septic tank with approved outlet filter. (Tank sizing requirement increases if house has a garbage grinder or a large tub) LEACHING SYSTEM: 660 square feet of effective leaching area required. System is to be designed with a maximum depth into original grade of twenty five (25) inches. Minimum Leaching System Spread must be addressed. SPECIFIC INSTRUCTIONS: I. Permit application to be completed and permit fees to be paid in full at time of application submission. 2. Installer's construction plot plan(drawn to scale)to be submitted and approved by this office prior to issuance of permit to construct. 3. Plot plan must indicate location of proposed structure, water supply, septic system, embankments, watercourses, property lines, and existing and proposed finished grades. Benchmark to be set and indicated on plan. Note on plan that existing septic system is to be properly abandoned. Wells on adjacent properties must be located and verified to meet minimum separating distances with proposed septic system (in accordance with Table 1 of Connecticut Technical Standards for Subsurface Sewage Disposal Systems). If adjacent properties are served by public water it must be noted on plan. SIGNATURE: DATE: 3a 1 sow■■rt ..� Town of South Windsor — Health Department 1540 Sullivan Avenue, South Windsor, CT 06074 as�e•C Phone: 860-644-2511 ext.248 Fax: 860-644-7280 SITE INVESTIGATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM Application/Permit#: Property Owner Lu x*- �� Location 1_ DEEP TEST PIT DATA/SOIL DESCRIPTIO S DATE: 4 0 30 \l (Record all Test Pits) TEST PIT: i TEST PIT: TEST PIT: TEST PIT: 0 1 1 '—roJ so,i hurt ji\�� 'Z2-tl-�NC�rr,v�l�,.11 fk��Cir. 11 Mottles: tv I u Mottles: Mottles: Mottles: GW: GW: GW: GW: Ledge: N 10 Ledge: Ledge: Ledge: Roots: `' Roots: Roots: Roots: Restrictive: 3" Restrictive: Restrictive: Restrictive: COMMENTS: ` w r, GROUNDWATER TABLE(Near max.,below max.,etc.): SOIL MOISTURE(High,medium,low,etc.): PERCOLATION TEST DATA DATE: I 30 (Record all Pero Tests) PERC: PERC: PERC: PERC: DEPTH: Hoi, DEPTH: DEPTH: DEPTH: PRESOAK: PRESOAK: PRESOAK: PRESOAK: TIME READING TIME READING TIME READING TIME READING 1 � � 11 11•� ` ILi.�'' :0 PERC PERC PERC PERC RATE: I RATE: I RATE: J RATE: COMMENTS: SITE INVESTIGATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM LOCATION DRAWING INCLUDING ALL TEST PITS AND PERCOLATION HOLES EB S SPECIAL CONDITIONS CONCLUSIONS Design Flow>2000 GPD Suitable for Sewage Disposal, Public Water Supply Watershed Unsuitable for Sewage Disposal Probable High Groundwater Additional Investigation Req'd Slo e>25 ercent Wet Season Monitoring.R '.d Pere Rate<1 min/inch Retest-During Wet Season Perc Rate>50 mWinch Licensed Engineer Plan Req'd: Ledge<5 feet below grade Other: Limited Suitable Area Open Watercourse or Wetlands Flood Plain/Seasonal Flooding Max.G.W.<36 inches below ode DESIGN RECOMMENDATIONS/COMMENTS Form completed by: v� (Certified Local Health Agent or P.E.) Accuracy assured by(If P.E.completed form): (Certified Local Health Agent) Others present for site investigation(Engineer,developer,installer etc.):