Loading...
HomeMy WebLinkAboutSeptic Repair 2579 Ellington Road 0', seq<. Town of South Windsor — Health Department 'd 1640 Sullivan Avenue, South Windsor, CT 06074 Phone: 860-644-2511 ext. 248 Fax: 860-644-7280 So�saa PERMIT TO DISCHARGE Approval is hereby given to Brian and Carin Faraci, in accordance with Public Health Code Section 19- 13-B103e(h)to discharge to a subsurface sewage disposal system located at 2579 Ellington Rd. in the town of South Windsor, CT that will receive domestic sewage from a: Residential building containing 4 bedrooms. Single family(Y/N):Y. Restaurant containing seats. Commercial/Office building providing square feet. Other structure as described: Design Flow= 600 gallons per day. Permitted Flow=600 gallons per day. The design flow shall equal the permitted flow,except for non-compliant repairs(See Section IV D). In order to provide a sufficient factor of safety it is recommended that the average daily discharge not exceed 2/3 of the permitted flow or 400 gallons per day. Operation and Maintenance: Septic tank shall be inspected regularly and pumped as needed but not less frequently than every five years. The septic tank has an effluent filter(Y/N)Y. Effluent filters require periodic cleaning. Failure to clean filters can result in sewage backup into the building or effluent breakout. Restaurants serviced by external grease interceptor tank(s)require quarterly inspections and cleaning as necessary. Tank pump-outs tracked by local health department(Y/N)N. If yes, stipulate pump-out requirements: Special Requirements and Restrictions: 1.In the future, if there is a septic system malfunction or failure it must be addressed. Exceptions(Repairs Only): File Information:Construction Permit No.201501176. Approved as-built on file(Y/N) Y. Date of Final Inspection: 8/31/15 Inspected By: Heather Oatis,Environmental Health Specialist Permit Issuance: Issued by: G .¢G . o�fcJ.9�zF2 xir Title: ,f•p, (Director o h or Registered Sanit ian) Signature: Date: / James Throwe 8602822684 p.1 c li ( J�+ I)K 1� G4v S' 4- � �j /,ix) Mo 17 � G2 fo �^ /Co B 13 4, Z 19 `/1 RECEIVE® se Q40 S4�G SEP 012015 �v 7�•1 �d 1i SOUTH WINDSOR r / Form#3 Technical Standards for Subsurface Sewage Disposal Systems Application/Permit#: Zfj`S, `l I 9 3 Final Inspection Report Local Health Department: Property Owner: COLA VN d(�G_h rnAA CA Property Address: Tq (�• -4sr1 . Town: t j i y-\ L cJ✓ Licensed Installer: 1 M !IhAwc License#: (� Approved Plan Information Check one: New System Repair/Replacement System �✓ Residential Building: bedrooms Lar e Tub: YES O Garbage Disposal: YES Non residential Buildin esidential Institution: GPD Plan Prepared by: Title: Plan Approved by: Date: Approval to Construct Date Permit Issued: f l i 1 t ie Permit Issued by: tZ Registered Sanitarian or Director of Health Inspection Information Licensed Installer Type II Date Present? Yes/No Comments Field Stake Inspection(house, 12�� S SLAS�tVVN k" �>t well,property lines,system etc.) S Strip/Scarification Sieve requi {Yet o) Select Fill Placement � Other: Final Inspection ✓� , .� Was 24 Hour(min)Installer Notice Given(Y/N): Date Final Inspection Requested: rr ll Date of As-Built (� Final Inspection Completed by: V S A roval: Permit to Discharge Issued by: Date: Registered Sanitarian or Director of Health FORM 93(Cont'd) Technical Standards for Subsurface Sewage Disposal Systems l/l/11 Final Inspection Report Housee`Sewer Information Pipe Type and ASTM Specification: t 1 Pipe Size: in. Pipe Invert Elevations at: Pipe Length: ft. ti. Foundation Wall: I g Pitch Required: L� Septic Tank: Pitch Provided: 1 f Tank Information S tic Tank Size: 1 Z Gallons Tank Inlet Elevation: Tank Manufacturer: (�A(I S Tank Outlet Elevation: �- Date Manufactured: 1 1` Riser Needed(YIN): Outlet FilterType/Manufacturer: Pump Chamber Size: Gallons Pump Alarm Chec d Pump Chamber Manufacturer: Float Control Elevation Verified Grease Interceptor Grease Interceptor Tank Tank Size: Gallons Manufacturer: Leaching System Information �( Approved Aggregate: Free of silt dirt and debris(Y/N): Sieve Required(Y/N): l Filter Fabric Present(Y/N) Type: fkf44 Aggregate Meets PHC Specifications(Y/N): Y Select Fill(Y/N): Meets PHC Specifications(Y/N) Sieve Information on File(Y/N): Leaching System Description(product,size,length,number of rows,level or serial etc.); Effective Leaching Area Required: q U0 sq. ft. Reserve Area Provided(N/A,Y/N) Effective Leaching Area Provided: ()0 sq.ft. Center to Center Spacing: ft System Installed Per Approved Plan Elevations(YN): Elevations Field Verified(YN): Elevation notes: I aD Iv, w4a 4� iLk -' Separation Distances Separation Distances Conform with Approved Plan(Y/N):�� Separation Distances Field Verified(Y/N): 1l PUG-27-2015 14:47 From:DESIATO SAND 8609295436 To:8602918979 P.1/1 �•uIIull0 ,IMUR ATI-Willlrlaatic 860-423-4438, p.02 r MATERJALSTESTING, INC. 55 LAURA STREET.-NEW MAVEN,CONNBCTICUT 06312*(2t)3)458-5216 42 BOSTON POST ROAD•WILLIMANTIC,CONNECTICUT 06216• (660)42.3-1972 DATE: 06.23-15 REPORT: M 11L8 ; CLIENT: De4pic,Sand&Gravel 999 Stafford Road Storrs,CT 06260 PROJECT: Client's Information SVBJECT: WASHED NAL -114 STM C•93 • �, i Material: Concrete Sand Source: 8 De isto a+,s d and C►'avel;8brrs, CT •���,:r�'"� •�4`•r--�.. I SMpled: by dient and delivered to MTI on 6/10115 � f I Gleve'Sibe percent Passing ASTM"3 100 100 ` #4(4.75mm) 99 95-100 riS(2,36mm) 81 80-100 ' #1 t'i {t,18mm) 58 5U•$$ #30(600pm) 37 25.60 #64(3001tm) 16 10-30 #100(150Nm) 4 2-10 0200(75umy 1,i 0-3 fineness Modulus 3.0 2.3-3.1 This mak ial as samplad And delivered meets the Bated speciilcatlon, j Materlals Testing,Inc. Richard C. Kearns i William J. Sovoy Ice: Cllgnl eaw T�stMonr#rw,M'"np Vow ma,p."0* wwwmtrdrmmq.Fa RECEIVED i AUG 2 6 2015 SOUTH WINDSOR HEALTH DEPT, i l ,�rC,c7 i tKf Ja r � l �r �n U/0 IT avil ofl.'')�t n° °*p��- — Health Department Town of South Windsor 'O c 1540 Sullivan Avenue, South Windsor, CT 06074 Phone: 860-644-2511 ext. 250 Fax: 860-644-7280 APPLICATION FOR APPROVAL TO CONSTRUCT A SUBSURFACE SEWAGE DISPOSAL SYSTEM Application/Permit#: To the Director of Health,Town of: Date: Lac" IS Application is hereby made for an approval to construct a subsurface sewage disposal system for a: rlpz 0 IJI&4 1 (Residential Building,Restaurant,Retail Building,etc.) r located at: ' 7 1 ^ f,1,te r' I�j (Street Address,Lot Number, Subdivision Name,Map,Block,Lot,etc.) New System Addition Repair Other Owner t V �'t ' Address Tel.No.� c) f Installer Val s"-!U 4 Address _I + :: Te1.No.74e 211e,)0 Installer License No.�?} � In accordance with detailed information stated below: Application fee paid Ito Signedl$ L, 7ZI Owner or.duly authorized representative) ----------------------------------------------------------------------------V------------------------------------------------------- ll GENERAL INFORMATION Soil Tests Conducted(Date): !� 1 Lot size hut Area of Special Concern(YIN): f yes,Reason(s): Basis of Design(#of Bedrooms,Restaurant Seats,Building Size,etc.): 4 Engineered Plan Required(Y/N): If yes,Name of Engineer: Address of Engineer: Design Plan Approved(Y/N):_\ Date of Approved Plan:_JJL31 Revision Date: Type of Water Supply � 1 t - If well,has location been approved(Y/N): Well Driller's Name: !y l Address: OFFICE USE ONLY Approval to Construct issued by: Date: (Director of Health or Registered Sanitarian) Signature: Title: Print Lookup Details Page I of 1 State of Connecticut Lookup Detail View Name Name JAMES E THROWE License Information lookup License Type License Expiration Granted License License Licensure Actions or Number Date Date Name Status Pending Charges Sub-Surface Sewage 3656 06/31/2016 12/03/1990 JAMES E. ACTIVE None Installer THROWE Generated on: 8/25/2015 9:22:23 AM https://www.elicense.ct.gov/Lookup/PrintLicenseDetails.aspx?cred=794145&contact=298... 8/25/2015 Town of South Windsor — Health Departmen '. 1540 Sullivan Avenue, South Windsor, CT 06074-2786 x��:yoSOR�o��wv Phone: 860-644-2511 ext. 248 Fax: 860-644-7280 APPROVAL TO CONSTRUCT OR REPAIR SEWAGE DISPOSAL SYSTEM Approval is hereby granted for the construction/repair of a subsurface sewage disposal system at the property described below: PROPERTY OWNER(S): Brian&Carin Farad STREET ADDRESS: 2579 Ellington Rd. TOWN:South Windsor INSTALLER: James Throwe CT. LIC# 3856 EXPIRES: 05/31/2016 RESIDENTIAL: #of Bedrooms-4 INSTRUCTIONS FOR INSTALLER 1. Construction plot plan submitted and approved by this office must be adhered to. 2. This office must be contacted for approval if any change is going to be made in the system location,size or design,or any changes in house,well or property line locations. 3. Any NEW sewage disposal system must conform to ALL requirements of Section 19-13-BI03 of the CT Public Health Code. 4. ALL new construction to be under DIRECT supervision of a CT licensed installer under Section 20-341 of the CT General Statutes. 5. The installer is RESPONSIBLE for VERIFYING LOCATIONS of PROPERTYLINES, WELLS, and BURIED UTILITYLEVES prior to construction. 6. Installer to notify South Windsor Health Dept.24 hours prior to the start of construction. 7. Installer to have septic tank covers removed at the time of inspection. SPECIFIC INSTRUCTIONS: 1, Install per approved plan, (dames Throwe, Dated: 8/13115). 2. Licensed Installer to field stake house, well (if applicable), permanent benchmark, and septic system. Offset stakes to include bottom of trench or flow line elevations. Health Dept. staff to conduct stake inspection prior to construction of system. 3. Permanent benchmark to be set within 50 feet horizontally and 12 feet vertically of septic system. 4. Install a 1,250 gallon two-compartment septic tank, with an approved outlet filter, Risers are to be installed if there is to be more than 12" cover over septic tank cleanouts. 5, Install 900 square feet of effective leaching area, consisting of one row 45 feet long and one row of 40 feet long of Mantis 536-8 units, bedded on the bottom and sides with sand fill meeting both the manufacturer's and select fill specifications. System to be installed per manufacturer's specifications. Systems with total cover that exceeds eighteen (18) inches as measured from the top of the units to finished grade shall be vented at the distal (far) end of the system. 6. Current Sieve analysis(within 30 days)for sand fill must be submitted o the South Heealfl1- epa men . -- 7. Max depth into original grade is not to exceed twenty four(24) inches. 8. Installer to schedule, and be present for final inspection with Health Dept. staff. Level to be set up for verification of elevations OR an engineer's/surveyor's as built will be required. 9. Installer to complete and submit septic system as built plan and drawing with ties to the house. 10. Existing septic system to be properl abandoned. SIGNATURE: �� DATE ISSUED: 8125115 RENEWAL: I I APPROVED BY: Dr.Gerald Schwartz, Director of Health EXPIRES: 8/25/16 EXPIRES:II THIS PERMIT IS VALID FOR A PERIOD OF ONE YEAR FROM DATE OF ISSUE, IN ACCORDANCE WITH THE CT PUBLIC HEALTH CODE SECTION 19-13-BI03e(F)(1). ONE RENEWAL IS POSSIBLE PROVIDED SOUTH WINDSOR HEALTH DEPARTMENT IS NOTIFIED PRIOR TO THE EXPIRATION DATE NOTED ABOVE. IF PERMIT EXPIRES, INSTALLERS ARE CHANGED, OR ANY OTHER DEVIATION FROM THE ORIGINAL PERMIT,A NEW APPLICATION MUST BE COMPLETED AND ALL APPLICABLE FEES MUST BE PAID. FEE PAID:10.00 CASH CHECK NIA DATE PAID:8125115