HomeMy WebLinkAbout1675 MAIN ST (9) REQUIRES:. 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 INCH RETURN AIR GRILL FOR ONE 3-1/4 X 14 IN-WALL RETURN BED ROOM # 3, SOUTH & EAST HEAT COOL AREA LOSS GAIN 30 SQUARE FEET OF TYPE 2, NO SHADE 46 .7 42 . 0 30 1401 1260 CEILING UNDER VENTILATED ATTIC, R38 INS 2 .1 1 .1 192 397 211 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0 . 0 0 . 0 192 0 0 WALL 13 X 8 FT, FRAME OR VENEER, R19 INS 4 .8 1.7 74 357 126 WALL 15 X 8 FT, FRAME OR VENEER, R19 INS 4 . 8 1 .7 120 580 204 ALLOWANCE FOR INFILTRATION, AVERAGE CONST 12 . 9 2 .1 192 2473 403 ALLOWANCE FOR LATENT HEAT 0 . 0 0.3 2204 0 661 TOTAL REQUIRED CFM AND BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 97 5208 2865 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES:-1 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES: 1 #661 12 X 4 SIDEWALL REGISTER OR 1 #411 4 X 10 FLOOR DIFFUSER OR REQUIRES: 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES_: 1 #650 10 X 6 INCH RETURN AIR GRILL FOR ONE 3-1/4 X 14 IN-WALL RETURN BATH RM ## 1, NORTH HEAT COOL AREA LOSS GAIN 8 .5 SQUARE FEET OF TYPE 2, NO SHADE 46 . 7 27.0 9 397 230 CEILING UNDER VENTILATED ATTIC, R19 INS 4 .3 2 .3 38 160 86 FLOOR OVER. CONDITIONING, NO LOSS/GAIN 0. 0 0 . 0 38 0 0 WALL 7 X 8 FT, FRAME OR VENEER, R19 INS 4 .8 1. 7 48 232 82 ALLOWANCE FOR INFILTRATION, AVERAGE CONST 12 . 9 2 . 1 38 489 80 ALLOWANCE FOR LATENT HEAT 0 .0 0 .3 478 0 143 ALLOWANCE FOR BATHROOM COMFORT 0.2 0 . 0 1278 256 0 TOTAL REQUIRED CFM AND BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM "@ RECOMMENDED MAX VELOCITY OF 600 FPM 21 1534 621 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 1 #661 6 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X 10 FLOOR DIFFUSER OR REQUIRES: 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 ##24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 INCH RETURN AIR GRILL FOR ONE 3-1/4 X 14 IN-WALL RETURN BATH RM # 2, NORTH HEAT COOL AREA LOSS GAIN 8.5 SQUARE FEET OF TYPE 2, NO SHADE 46.7 27. 0 9 397 230 CEILING UNDER VENTILATED ATTIC, R38 INS 2.1 1.1 38 78 41 FLOOR OVER CONDITIONING, NO LOSS/GAIN 0. 0 0.0 38 0 0 WALL 7 X 8 FT, FRAME OR VENEER, R19 INS 4 .8 1.7 48 232 82 ALLOWANCE FOR INFILTRATION, AVERAGE CONST 12 . 9 2 .1 38 489 80 ALLOWANCE FOR LATENT HEAT 0. 0 0 .3 433 0 130 ALLOWANCE FOR BATHROOM COMFORT 0 .2 0 .0 1196 239 0 TOTAL REQUIRED CFM AND BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM @ .RECOMMENDED MAX VELOCITY OF 600 FPM 20 1435 563