HomeMy WebLinkAbout1675 MAIN ST (11) L 79.6 SQUARE FEET OF TYPE 2, NO SHADE 46. 7 27. 0 80 3717 2149 CEILING UNDER VENTILATED ATTIC, NO INS 48.2 19 . 0 308 14827 5846 HARDWOOD FLOOR, NO INS OVER ENCLOSED SPACE 12 . 5 0 . 0 308 3861 0 WALL 21 X 8 FT, FRAME OR VENEER, R19 INS 4 .8 1 . 7 88 425 150 ALLOWANCE FOR INFILTRATION, AVERAGE CONST 12 .9 2 . 1 308 3967 6-47 ALLOWANCE FOR LATENT HEAT 0. 0 0 .3 8792 0 2638 TOTAL- REQUIRED CFM AND BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 388 26797 11430 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 3 BRANCH DUCT - (7 IN ROUND) OR (3-1/4 X 12 WALL STACK) REQUIRES: 3 #661 10 X 6 SIDEWALL REGISTER OR 3 #411 6 X 10 FLOOR DIFFUSER OR REQUIRES; 3 #16 8 IN ROUND CEILING DIFFUSER OR 3 #24 8 X 8 INCH SQUARE DIFFUSER REQUIRES: 3 #650 10 X 6 INCH RETURN AIR GRILL FOR (3) 3-1/4 X 14 IN-WALL RETURN KITCHEN, , NORTH HEAT COOL AREA LOSS GAIN 29 SQUARE FEET OF TYPE 2, NO SHADE 46 . 7 27.0 29 1354 783 CEILING UNDER- VENTILATED ATTIC, R19 INS 4 .3 2 .3 284 1208 653 HARDWOOD. FLOOR, NO INS OVER ENCLOSED SPACE 12.5 0 .0 284 3560 0 WALL 1.3 X 8 FT, FRAME OR VENEER, R19 INS 4 . 8 1. 7 75 362 128 ALLOWANCE FOR INFILTRATION, AVERAGE CONST 12 . 9 2 .1 284 3658 596 ALLOWANCE FOR LATENT HEAT 0 . 0 0 .3 2160 0 648 ALLOWANCE FOR APPLIANCES AND MOTORS 0 . 0 2 .0 600 0 1200 TOTAL f(SQUIRED CFM AND BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 141 10142 4008 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES: 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 INCH RETURN AIR GRILL FOR ONE 3-1/4 X 14 IN-WALL RETURN DINING ROOM, SOUTH & EAST HEAT COOL AREA LOSS GAIN 30 SQUARE FEET OF TYPE 2, NO SHADE 46 . 7 42 . 0 30 1401 1260 CEILING UNDER VENTILATED ATTIC, NO INS 48 .2 19 .0 155 7459 2941 HARDWOOD FLOOR, NO INS OVER ENCLOSED SPACE 12 .5 0 . 0 155 1943 0 WALL 13 X 8 FT, FRAME OR VENEER, R19 INS 4 .8 1.7 74 357 126 WALL 8 X 8 FT, FRAME OR VENEER, R19 INS 4.8 1.7 64 309 109 ALLOWANCE FOR INFILTRATION, AVERAGE CONST 12 . 9 2 .1 155 1996 326 ALLOWANCE FOR LATENT HEAT 0 .0 0.3 4762 0 1429 TOTAL REQUIRED CFI AND BTU HEAT LOSS/GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 210 13465 6191 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT -- (6 IN ROUND) OR (7 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES: 2 #661 14 X 4 SIDEWALL REGISTER OR 2 ##411. 4 X 12 FLOOR DIFFUSER OR REQUIRES: 2 ##16 8 IN ROUND CEILING DIFFUSER OR 2 ##24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 2 #650 10 X 6 INCH RETURN AIR GRILL FOR TWO 3-1/4 X 14 IN-WALL RETURN